hi i want to ask you, in 4:35 the 10 milliseconds means the transmission speed of importing data from server ? if yes, do you know the speed of respberry card ?
@BratPit3 жыл бұрын
It only means that PLC recalls cyclic interrupt every 10ms and executes instances (function blocks, functions) which are contained in this instance. Speed of data transmission is another concern here. Data after cyclic interrupt execution are being held in buffer and transmitted when communication processor is free to transmission. So, it's matter of amount of data which are being exchanged with other devices on the net. You can try to check using WireShark or other programs to analyze web traffic. Normally it's quite fast -> milliseconds.
@MiguelGomez-rc7ou2 жыл бұрын
HI, Great Video!!! Is possible to try this SQL Connection with PLC SIM? Thanks!!!
@sql4automation5842 жыл бұрын
Hi Miguel, thanks! Yes, as far as I know, it should be possible with PLC SIM Advanced. You can write as at info@inasoft.ch if you run into problems.
@JazlyHadhi Жыл бұрын
Hi, Connector IP should be my laptop IP right? but its not showing my IP on the drop down list. i can see only the localhost
@sql4automation584 Жыл бұрын
Hi, yes if you want to connect a PLC to the connector you would need the IP of the interface which is in the same network as the PLC. Maybe you could check your network adapter settings. Please write us at info@inasoft.ch if you need more help. :)
@yassinexm-n9r3 ай бұрын
I wonder if it possible to autoconnect everytime the software is opened
@sql4automation5842 ай бұрын
Hi! You mean that the config tool automatically connects to the last known connector service? The service runs on its own automatically, so you only need the config tool to initially set up the connections or change settings.
@yassinexm-n9r2 ай бұрын
@@sql4automation584 Yes i Discovered that lately thanks for the answer it works good
@michelepaiardi59833 жыл бұрын
Hello, to make S71200 and the SQL Database communicate, do you need the S4A Query Tool software?
@sql4automation5843 жыл бұрын
Hi, when using our software, the S4A Connector and S4A Config Tool are enough. The S4A Query Tool and S4A Debugger are just usefool tools when developing the application.
@michelepaiardi59833 жыл бұрын
@@sql4automation584 Ok thanks for restoring me.
@mathankumard378 Жыл бұрын
hi, this video is very useful to us. is it possible to connect SQL database using S7300 like this way??
@sql4automation584 Жыл бұрын
Hi, that's nice to hear! :) Yes that should be possible. You can download all the required files from our website and test it out: www.sql4automation.com/en/compatibility/supported-controllers/detail/sql-database-connector-plc-siemens-s7.php
@minhhieunguyen34842 жыл бұрын
Excuse me! Can i use this program to connect phpmysql?
@praveenajai95882 ай бұрын
Hi Can I get for abb plc also like this method?
@sql4automation5842 ай бұрын
Hi, we have libraries for AC500 PLCs. Please write us at info@inasoft.ch if you need more information or do have a different PLC.
@waqaryousaf320710 ай бұрын
Can i any trigger any value from sql database to plc Kindky help me
@sql4automation58410 ай бұрын
Yes you need to write a program in the PLC which continuously reads out / "SELECT"s values from the database. So when the value in the database changes, the PLC will read that new value. If you're using Siemens you'll find examples on how to do that in our example project. It comes included with the SQL4automation download on our website.
@MightyAutomation3 жыл бұрын
Great video please share link for Rockwell sample project
@leakersshakh9317 Жыл бұрын
Can you send the example project with tia V16? I want it very very important
@sql4automation584 Жыл бұрын
Can you send us an email to info@inasoft.ch? It should be possible to upgrade the version you downloaded to V16, when you open it. But we can send it to you.
@kunalparihar86652 жыл бұрын
The video is very interesting I have a question how do you connect a physical plc to an SQL database
@sql4automation5842 жыл бұрын
Hi Kunal, thank you! In the following video you can see an example setup: kzbin.info/www/bejne/fIbMZZynr5iDpJo You can also find more information about it on our website: www.sql4automation.com/en/functionality/index.php
@DungLe-wy5xk3 жыл бұрын
Hello, I want to connect TwinCAT 3 to a SQL server database. Can you help me, please?
@sql4automation5843 жыл бұрын
Hi, can you please send an email to 'info@inasoft.ch'? Thank you
@tranvandao19984 жыл бұрын
how to add sql4siment into TIA
@lexobsm4 жыл бұрын
Hi, Really Nice video ! I'm asking if plc program can also update his variables from this SQL database ?
@sql4automation5844 жыл бұрын
Hi, thank you! Yes that's definitely possible. You can see how it works in the "Select"-Example also shown in this video around 7:00
@storyofdivine99703 жыл бұрын
How to connect mysql to scada
@jorgematassanz51694 жыл бұрын
Hi I have downloaded the example project, however when I try to open it up from TIA Portal V11 it doesn´t show up (SQL4S7-1200-TIA.ap13) Is it because there are different versions? What can I do?
@sql4automation5844 жыл бұрын
Hi Jorge Yes the project is written for the TIA Portal Version 13. So you would need at least that version or something more recent. I would recommend you upgrade your TIA-Portal to a newer version. I'm afraid we don't support older versions than 13.
@DP01903 жыл бұрын
Hello, your S4A Config, SQL Server Management studio and TIA Portal are all inside Virtual Machine???. Can you provide an Email, I have some questions. Thanks
@sql4automation5843 жыл бұрын
Hi Dino, yes in this example I had them running in a VM. But you could easily install the programs on different devices in the same network. You can write us at info@inasoft.ch
@guruchordiya34164 жыл бұрын
Do i need physical plc for checking example???
@sql4automation5844 жыл бұрын
Hi GURU, if you want to test with Siemens you'll need a physical PLC or a SoftPLC from Siemens, as far as I know. But we also support many other PLCs if the type doesn't matter to you. You could for example use Codesys.
@frankchristiansen25854 жыл бұрын
Does this work with TIA simulator?
@sql4automation5844 жыл бұрын
Hi Frank, you would need the PLCSIM Advanced. But I think you can download a trial version of it and test it for 21 days.
@MightyAutomation3 жыл бұрын
Upload video for Rockwell plc
@anomanderrake3778 Жыл бұрын
The company is still working?
@sql4automation584 Жыл бұрын
Yes, just not creating new videos at the moment. If you have questions you can also write as at info@inasoft.ch.
@storyofdivine99703 жыл бұрын
Can you help me
@vuduyphuong23273 жыл бұрын
Hello, I try to setup wHardwareID but when I open obCyclicInterrupt DB it don't have wHardwareID, so I see Example Project different video project. Can you send project that You used in this video to me? Thank you very much!