No video

How to Connect For,Rev and Stop Push Button With Parameter in Schneider ATV310!

  Рет қаралды 13,403

RV Electrical Guide

RV Electrical Guide

Күн бұрын

How to Connect For Rev and Stop Push Button With Parameter in Schneider ATV310‪@rvelectricalguide‬
About this video:-Friend is video me Forward Reverse and Stop Push Button ka connection or parameter setting kaise karna hai bilkul detail me samjhane ki kosis kiya gaya hai , agar video aap ko accha lage to ek like kar dijiyega.
Agar iske bassic parameter meter ka setting pe vedio dekhne hain to aap ko niche vedio ka link mil jaega waha se ja ke aap watch kar sakte hain, or bhi vedio dekhne ke liye niche diye gaye channel par ja ke dekh sakte hain.
KZbin‪@rvelectricalguide‬
Thanks for watching
Other videos link:-
• How to set ATV310 Basi...
• How to Forward Reverse...
• Star Delta Power & Con...
• Schneider ATV 310 VFD ...
• SchneiderEM6433H Energ...
• Schneider ATV 310 vfd ...

Пікірлер: 30
@MalikJi-om5js
@MalikJi-om5js 7 ай бұрын
what a nice way of teach so nice off you what a grate
@rvelectricalguide
@rvelectricalguide 7 ай бұрын
Thank you so much bro
@satishkumariyer6953
@satishkumariyer6953 Жыл бұрын
Nice vdo
@dhirajkaran4511
@dhirajkaran4511 6 ай бұрын
Sir mere ko speed Kam jyada push button se karna h or on off bhi push button se karna h please help
@rvelectricalguide
@rvelectricalguide 6 ай бұрын
Aap Hamen Samay de sakte hain main aapko video ke Madhyam se bata dunga , Vaise iska parameter ki jankari chahie to aap P506 , P506.0 ,P506.1 per jakar set kar sakte hain, isi parameter ko setting karne ke bad push button se speed ko Ghata aur Badha sakte hain
@jaharngialam3699
@jaharngialam3699 Ай бұрын
Terminal not working. How to solve this???
@MalikJi-om5js
@MalikJi-om5js 7 ай бұрын
bro i have question can i use thermostat and terminal of thermostat has three speed control options. can we use thermostat as jog dial for speed such as low,med. high please explain
@rvelectricalguide
@rvelectricalguide 7 ай бұрын
Thermostat is only used to control the temperature in the heating system, you cannot use it to control the speed. Because it works like NO NC Ok bro Thanks for comment
@MalikJi-om5js
@MalikJi-om5js 7 ай бұрын
Thanks for your earlier reply. You are really great. Bro in one project I saw a fresh Air handling unit (FAHU) that was operation with vfd and control by thermostat .temperature and speed both systems was working . Dig it out please.
@ronaktiwari4828
@ronaktiwari4828 7 ай бұрын
Why I cannot change motor current (305 parameter) from jog dial (Potentiometer in vfd)?
@rvelectricalguide
@rvelectricalguide 7 ай бұрын
Can you tell the kw/hp of the drive?
@madhusudansharma7368
@madhusudansharma7368 Ай бұрын
Mujhe drive ke display PE motor ke ampear set karna hai, kounsa parameters set karna hai
@rvelectricalguide
@rvelectricalguide Ай бұрын
kzbin.info/www/bejne/gKCZdXuZr7Ksja8si=PPS3Qwtrap9A9uTE
@rvelectricalguide
@rvelectricalguide Ай бұрын
Motor ka ampear parameter setting ke liye is video ke link par ja ke dekh shakte hai
@rvelectricalguide
@rvelectricalguide Ай бұрын
P 305 per set hoga
@animeshmukherjee6342
@animeshmukherjee6342 11 ай бұрын
How to Factory reset on ATV310? Any Code ?
@rvelectricalguide
@rvelectricalguide 11 ай бұрын
Go to Parameter number 102 and set here 64 ,then press ok
@animeshmukherjee6342
@animeshmukherjee6342 11 ай бұрын
@@rvelectricalguide Thank you ❤️
@animeshmukherjee6342
@animeshmukherjee6342 11 ай бұрын
​@@rvelectricalguide Default Jo tha Oo ajeyaga to?
@rvelectricalguide
@rvelectricalguide 11 ай бұрын
@animeshmukherjee6342 Default kya aaraha hai?
@serajasghar8703
@serajasghar8703 18 күн бұрын
06 ka errors show ho raha hai
@rvelectricalguide
@rvelectricalguide 17 күн бұрын
06 Freewheel stop control ka status dikha raha hain Drive par load kya connect hai? Or start stop kaise karte hai aap?
@serajasghar8703
@serajasghar8703 17 күн бұрын
@@rvelectricalguide bms se
@harpalsinhrathod8772
@harpalsinhrathod8772 11 ай бұрын
Plz rply do
@rvelectricalguide
@rvelectricalguide 11 ай бұрын
What is the fault F006 ?
@harpalsinhrathod8772
@harpalsinhrathod8772 11 ай бұрын
Send me ans
@rvelectricalguide
@rvelectricalguide 11 ай бұрын
If F006 fault coming on drive, then current measurement is not correct due to hardware circuit fault
@harpalsinhrathod8772
@harpalsinhrathod8772 11 ай бұрын
06 ka errors show ho raha hai
@rvelectricalguide
@rvelectricalguide 11 ай бұрын
If there is showing only 06 Error, then you have to check 2wire or 3wire controlling wiring and parameter setting
Schneider vfd ATV 310 complete wiring and programming |
17:00
PEARL ENGINEERING
Рет қаралды 26 М.
Pool Bed Prank By My Grandpa 😂 #funny
00:47
SKITS
Рет қаралды 20 МЛН
Zombie Boy Saved My Life 💚
00:29
Alan Chikin Chow
Рет қаралды 12 МЛН
Schneider Atv 310 programing and installation crane application esy programing
21:50
Mishra Electrical Pvt Ltd.
Рет қаралды 20 М.
Schneider ATV-320 basic parameter setting.Multi speed setting with Motor Run.Control 2 wire.
15:22
Schneider atv310 waring setting programming in hindi ||
21:58
Ruchi electrical
Рет қаралды 5 М.