Good work sir , i too was designing 5kw with cs and finding the same issue, but now its all clear all thanks to you.
@solarfacts42422 жыл бұрын
Thanks 🙏
@sourabhsharma99852 жыл бұрын
Love to see that how basic KCL can solve the bigger problem,very nice vedio sir.
@solarfacts42422 жыл бұрын
Thanks Sourabh
@harikrishnankr91502 жыл бұрын
😍😍
@solarfacts42422 жыл бұрын
Thanks 🙏
@siddharthsrinet90222 жыл бұрын
👍👍👍👍
@solarfacts42422 жыл бұрын
Thanks
@sathyaprasad14118 ай бұрын
,,👌👌👌👏👏👏👍👍👍👍
@siddharthsrinet90222 жыл бұрын
Bhai kabhi transformer less aur transformer wale inverter me diffrence wala vedio banao
@solarfacts42422 жыл бұрын
Sure
@pgmakwana Жыл бұрын
Sir jo baord pe write karke rakhte ho vo value Barbara dikhti nahi he so write big so we under stand better
@solarfacts4242 Жыл бұрын
Please rotate your phone I am sure it will be visible
@hb16053 ай бұрын
Sir please suggest me good on grid 1 phase inverter for adani TOPCcon 570wh (I am confused in Havells or Polycab)
@EmranKhan-l4l Жыл бұрын
Hello sir. Good Explanation. But if MC4 burn or damage of any positive or negative end will cause a dangerous situation for the inverter at peak load. Isn't it? Please explain
@solarfacts4242 Жыл бұрын
Actually in this case both the MPPT Are working parallel it’s not working individually
@saifsyedmohammad3769 Жыл бұрын
I have 15 panels of 335 W panels in series with a total voltage of 520V. My inverter supports 1000V Voc. I have a 550 W panel with a slightly higher current rating lying around. Can I connect this single panel in series will all other 15 panels ?
@solarfacts4242 Жыл бұрын
You can but due to miss match your 550 watt panel will also work as a 335 watt panel
@mohanmachinerymart45512 жыл бұрын
hello sir yeh parallel mode har invertor mai hota hai
@solarfacts42422 жыл бұрын
No but this is in Havells
@saifsyedmohammad3769 Жыл бұрын
Help Please !I have 15 panels of 335 W panels in series with a total voltage of 520V. My inverter supports 1000V Voc. I have a 550 W panel with a slightly higher current rating lying around. Can I connect this single panel in series will all other 15 panels ?
@solarfacts4242 Жыл бұрын
You can but due to miss match your 550 watt panel will also work as a 335 watt panel
@pramodshah183011 ай бұрын
Mere question hai ki. Mppt agar ak hai inverter me 100kw le delta me. Or usme 8 string de rahe hai smb me each having 16 amp. How will mppt work than. Multiple string but only 1 mppt in imverter?
@MR_SOLAR_BABA2 жыл бұрын
It is dangerous practice, suppose one mppt stops working connector may burn or damaged to the inverter.
@solarfacts4242 Жыл бұрын
Sir actually both tha MPPT is working in parallel mode if there is any problem with one MPPT both will not work
@solarfacts4242 Жыл бұрын
So there is no problem
@utkarsh329 Жыл бұрын
but in Y-connector case only one string making then this will not make use of 2 MPPT (if shadow on 1 panel then whole system down)
@solarfacts4242 Жыл бұрын
Yes this will be problem
@poorvadityainfrasolutions51862 жыл бұрын
How to connect if inverter have only single mppt
@solarfacts42422 жыл бұрын
then not possible
@ptkgupta2 жыл бұрын
Problem: 540Wp/IMP: 12.9A Using Y connectors, we We are unable to overload the inverter as only 1 string can be connected per MPPT. Any suggestions. Can you suggest some good inverters with 30A+ MPPTs in 50 to 100KW range.
@solarfacts42422 жыл бұрын
for 50 and 100 Kw you can get high rating of MPPT
@karkar5360 Жыл бұрын
The 17 amp will not divide into as you said.8.5 +8.5 by Y connectors You are wrong make it correct .
@solarfacts4242 Жыл бұрын
Sorry but in this case both the mppt will work in parallel mode and equal amount of current will flow
@yasirkazi97032 жыл бұрын
Can you please confirm that the current through the y connector gets divided equally? Also, does the inverter manufacturer allow us to use this? Technically it looks feasible. But the manufacturer should also approve it so that it helps in case of claiming warranty.
@solarfacts42422 жыл бұрын
Yes this is approved by Havells
@gnaneshwarsamal71762 жыл бұрын
if you are using 2 MMPT means than you can select parallel operation mode
@solarfacts42422 жыл бұрын
Yes
@CoolDude-vc2fl4 ай бұрын
MPPT can not share a string.
@solarfacts42424 ай бұрын
It can and I have done at multiple sites
@sachinwadje39482 жыл бұрын
Not agreed with last point explain by you at evening or in morning voltage not get affected only current generation is lower So in case of renewsys 400wp module we can used two separate string Benefit of using two separate string is in case of failure of other string at least half generation is continue other thing nicely explain by you