How to control the VFD via RS485 interface

  Рет қаралды 64,005

ATO Automation

ATO Automation

Күн бұрын

Пікірлер: 35
@victorsi1992
@victorsi1992 4 жыл бұрын
Мужик, я не знаю що ти там робиш, але ти мені дуже допоміг з пошуком потрібної програми. Велике тобі ДЯКУЮ. Чесно, від душі дякую.
@paulz8750
@paulz8750 4 жыл бұрын
Never understand why such annoying music has to played on videos like these, where perhaps you are trying to think through technical details in your mind. Thank goodness for the mute button. Or is it just me?
@ATOcom
@ATOcom 4 жыл бұрын
Sorry my friend......
@hpevans9041
@hpevans9041 9 ай бұрын
I’m loving the music
@YetiRUS
@YetiRUS 3 жыл бұрын
Мужик, спасибо! Выручил!))
@mlab47robotica
@mlab47robotica Жыл бұрын
Can you this usung xinje servo drive ? Please help me
@bartplackle3200
@bartplackle3200 2 жыл бұрын
Quick question where did you find the modbus register definition, have a 9100 but cannot find it anywhere, much much thnx !
@ATOcom
@ATOcom 2 жыл бұрын
The special registers defined by each manufacturer have different meanings, so you need to find your manufacturer.
@makhgalsurenmyagmarsuren4451
@makhgalsurenmyagmarsuren4451 5 жыл бұрын
How to know detail info about debugging software
@mitchimal
@mitchimal 3 жыл бұрын
Where can I find the manual with the 485 protocol for this VFD? It looks similar to the VFD I have not it's written horribly so I'm just a bit stuck. Cheers
@ATOcom
@ATOcom 3 жыл бұрын
If you buy a VFD from the ATO, then you can obtain the manual from us.If it's another brand, our manual doesn't seem to be of any use to you.
@mitchimal
@mitchimal 3 жыл бұрын
@@ATOcom well the codes look pretty similar but fair enough. This looks like a Chinese made unit?
@chickenz4604
@chickenz4604 3 жыл бұрын
what is the difference between using analog input output vs RS485 for communicating between PLC and VFD?? thx
@ATOcom
@ATOcom 3 жыл бұрын
When you know what an analog quantity is and what a digital quantity is, you will know it.
@chickenz4604
@chickenz4604 3 жыл бұрын
@@ATOcom it is not about digital , so you prefer to use RS485 for this type of application?
@ATOcom
@ATOcom 3 жыл бұрын
@@chickenz4604 Each has various advantages. RS485 (Modbus RTU protocol) is more suitable for centralized control or remote control. Many automated control systems use this control method.
@hassanabualrub4538
@hassanabualrub4538 Жыл бұрын
how 0F A0 = 40 which converter you used?? if dec to hex 40 = 28
@ATOcom
@ATOcom Жыл бұрын
0FA0 Hex=4000, you can regard it as 40.00Hz
@ATOcom
@ATOcom Жыл бұрын
0FA0 Hex=4000 decimal
@tramtran5562
@tramtran5562 4 жыл бұрын
I'm newbie in Modbus. I don't know at 5:17s, you receive response data frame is 00 14, why is it 2.0 ( not 20) ?
@ATOcom
@ATOcom 4 жыл бұрын
The hexadecimal system is used here, 0014 (hexadecimal)=20 (decimal).
@tramtran5562
@tramtran5562 4 жыл бұрын
@@ATOcom Thank for your reply. But I read manual reference then I see the value must be 2.0 (not 20). I don't know that stuff.
@ATOcom
@ATOcom 4 жыл бұрын
@@tramtran5562 Under normal circumstances, the returned data can only be used after conversion, whether it is hexadecimal conversion or magnification conversion, as long as they are related, we can use it. Assuming that 0.1A is used as a unit (or accuracy), then 2.0A is equivalent to 20 units, which is 0014 Hex.
@saimakhan3588
@saimakhan3588 Ай бұрын
how can we do this esp32?
@МетодиПетков-щ1ф
@МетодиПетков-щ1ф 2 жыл бұрын
Hello. Thank you for this video. Can you explain me how convert P3.09 to hex number?
@ATOcom
@ATOcom 2 жыл бұрын
P3.09 is just "Communication configuration", why do you want to convert it to hexadecimal? Are you using ATO brand VFD?
@МетодиПетков-щ1ф
@МетодиПетков-щ1ф 2 жыл бұрын
Thanks for the reply. I see it's just for setup, but I had to give you an example to help you understand my question. The registers are described in this format in the user manual. I want to receive information about current, voltage, ask about the type of error, etc. How can I convert the registers set in this format ("P3.09" only for example) to hexadecimal numbers so that I can communicate with RS 485? Now I'm researching to choose which device to buy.
@ATOcom
@ATOcom 2 жыл бұрын
@@МетодиПетков-щ1ф 1. About communication. We don't need to convert P3.09 to hexadecimal. In the parameter expression of P3.09, it has units digit, tens digit, and hundreds digit. Each different decimal number represents a different meaning, such as P3. 09=163, its corresponding meaning is "Modbus RTU protocol, 1-8-1 without parity format, 9600bps". Different data have different meanings. We only need to correspond these communication data with the control terminal to communicate. These are common practices. 2. Information about reading or writing. Our user manual will show the special storage area inside the ATO VFD, we only need to read the data in the storage area or write the data to complete what you want. However, this part of data reading and writing are all in hexadecimal (machine language). 3. For more detailed instructions, please refer to our official manual, www.ato.com/Content/doc/GK3000-VFD-user-manual.pdf 4. Purchase link: 1-phase to 3-phase, www.ato.com/single-phase-to-three-phase-vfd 3-phase to 3-phase, www.ato.com/three-phase-vfd
@alfaelectricalsrajkot9901
@alfaelectricalsrajkot9901 4 ай бұрын
HOW CAN I INCREASE MY HZ TO 60 MAX WITH RS485
@abdelkarimkhelifi863
@abdelkarimkhelifi863 Жыл бұрын
Please i need this software
@z_review5247
@z_review5247 2 жыл бұрын
Why 00 14 hex is 2 not 20?
@yashjoshi
@yashjoshi 5 жыл бұрын
Can you please share the name of software used on PC?
@ATOcom
@ATOcom 5 жыл бұрын
Commix 1.4
@rafeekaita11
@rafeekaita11 3 жыл бұрын
can i please get the source code of the program?
@ttautomation7088
@ttautomation7088 3 жыл бұрын
Model of VFD? Thanks!
How to control VFD frequency with a speed potentiometer
5:10
ATO Automation
Рет қаралды 32 М.
VFD and PLC serial communication (RS485/Modbus-RTU)
8:17
ATO Automation
Рет қаралды 62 М.
Good teacher wows kids with practical examples #shorts
00:32
I migliori trucchetti di Fabiosa
Рет қаралды 13 МЛН
Хасанның өзі эфирге шықты! “Қылмыстық топқа қатысым жоқ” дейді. Талғарда не болды? Халық сене ме?
09:25
Демократиялы Қазақстан / Демократический Казахстан
Рет қаралды 347 М.
Flipping Robot vs Heavier And Heavier Objects
00:34
Mark Rober
Рет қаралды 59 МЛН
Não sabe esconder Comida
00:20
DUDU e CAROL
Рет қаралды 39 МЛН
PLC & HMI analog output programming-VFD frequency control
7:28
ATO Automation
Рет қаралды 80 М.
All You Need to Know About Modbus RTU
9:18
RealTimeAutomation
Рет қаралды 378 М.
How to Interface RS485 Module with STM32
12:38
ControllersTech
Рет қаралды 50 М.
VFD analog input (4-20mA) for frequency control
4:48
ATO Automation
Рет қаралды 40 М.
How To Program And Wire An HY VFD (Complete Breakdown)..
13:20
Corvetteguy50
Рет қаралды 30 М.
PLC control of a VFD via Modbus
4:28
BTCInstrumentation
Рет қаралды 100 М.
Good teacher wows kids with practical examples #shorts
00:32
I migliori trucchetti di Fabiosa
Рет қаралды 13 МЛН