Please you need to show us step by step where all wires a connected practically cause people may not be familiar with some circuit diagram
@fredastaire61562 жыл бұрын
Great video! Is there a such thing as using a wireless remote control for this set up?
@glennedward22015 жыл бұрын
I’m thinking about using a relay turned on by my 120v side of circuit. Switch on triggers relay for 240v. Would be nice not to have several switches.
@drakon13002 жыл бұрын
I just bought a model EM15-sp1s1-1d5 /1ph 120v ac input -1.5kw 1ph/3ph 0~220v ac 7a output vfd for my wood lathe. this video shows a vfd with different terminals then the one I got and not sure which terminals to use for forward - reverse .. none of the terminals are labeled for. rev. or X ...
@joaotuga71819 ай бұрын
Please what are the specifications of the contactor and relay?
@ATOcom9 ай бұрын
Thank you for your inquiry sir. The specs of the contactor: 32A, 4 Pole, NO. For the relay, check out here: www.ato.com/electromagnetic-relay-dpdt-12-24-110-220v-coils
@russgould70711 күн бұрын
Can an " ON - OFF -ON " toggle switch be used to control foward and reverse?
@rolandiansillano30682 жыл бұрын
Hi sir can you give me idea how to run motor with vfd 10 hz to 50hz repeatedly
@ATOcom2 жыл бұрын
You mean run at 10Hz for a while, then run at 50Hz for a while, and so on? 1. You can use VFD two-stage speed control mode + 2 time relays, and connect a group of multi-function terminals after each time. 2. You can use PLC to build control logic to activate a certain speed at regular intervals. VFD can choose multi-speed control or directly control VFD frequency by Modbus communication. ATO VFD multi-speed control mode link, kzbin.info/www/bejne/q4uupIOdmKdll5o
@bookquotes54 жыл бұрын
Thanks brother !!! Respect from Karachi , Pakistan.. Can you guide us briefly about VFD basics
@nagarasud14413 жыл бұрын
Thank you 👍
@jaykesapalaran7001 Жыл бұрын
good tutorial, PLEASE CREAT A VIDEO HOW TO PROGRAM COMMAND IN SOFT STARTER AND VFD,🇵🇭🇵🇭🇵🇭❤
@ele48535 жыл бұрын
is your "switch" (green button switch) momentarily on or it "toggles" between on and off at each press?
@ATOcom5 жыл бұрын
In the video, the green button at 2:07 is a self-locking button (it is always ON after being pressed), and the green button on the rear control box is an auto-reset button (ON when pressed, and OFF when not pressed).
@ele48535 жыл бұрын
@@ATOcom OK so the one on the 2:07min. is a ON/OFF normally open and the "Green and White" on the yellow box are Momentarily Normally Open. What is the rate of amperage and voltage for the switches on the yellow box? Thanks in advance.
@vfgrfbgrb4 жыл бұрын
@@ATOcom don't understand schmetic so t1 t3 from contacter connected to vfd
@ioannisgalanos79113 жыл бұрын
Hello, can i start any frequency inverter with single phase? My motor is three phase. My inverter is a RM5G. I supose must change some settings.
@ATOcom3 жыл бұрын
I did not know the model you are using; but this has a dedicated VFD, such as ATO 1-phase input to 3-phase output VFD, www.ato.com/single-phase-to-three-phase-vfd
@marloulariego96742 жыл бұрын
Is this also applicable for a 1.5 HP Single phase motor? Can i ask for the specifications for the items use in this video?
@markzalavari17805 жыл бұрын
Hi! How to wirelessly remote controll frequency?
@darbats4 жыл бұрын
I have an air compressor 10hp. Can the VFD run the motor without the Red, White, Green buttons?
@ATOcom4 жыл бұрын
Yes, you can choose the control method: panel control, terminal control, modbus-RTU control, analog control.
@alikhalaf8054 жыл бұрын
Why not use rela 220v ac allowance rela 24 v dc I am waiting for your answer, please
@ATOcom4 жыл бұрын
24VDC is a safe voltage and 220VAC is a dangerous voltage. In the application of automation equipment, the safe voltage is usually used to control the dangerous voltage.
@alikhalaf8054 жыл бұрын
@@ATOcom Thanks a lot for clarification. I am very grateful
@ATOcom4 жыл бұрын
@@alikhalaf805 : )
@DemiFlower10103 жыл бұрын
Hi i just purchased a GK3000 single phase in and out for my 3hp lathe motor. Do you have a similar scamatic for me to use so I can make a enclosure to use. The only difference I need is I want to put a variable knob on the lathe and I want to use a joystick up for forward and down for reverse. Please if you can send me a scamatic.
@ATOcom3 жыл бұрын
Is this video what you want? kzbin.info/www/bejne/invWf2SdjJ2bjLM
@DemiFlower10103 жыл бұрын
@@ATOcom yes this helps but I have other questions not answered yet, this video is still for 3phase correct? I have single phase in and out. Am I gonna need the dc converter? And what about a scamatic for a joystick for forward and reverse control?
@ATOcom3 жыл бұрын
@@DemiFlower1010 1. Yes, the video is applicable to all GK3000-2S series (including single-phase output, three-phase output VFD), but it should be reminded that single-phase motors are not suitable for long-term operation below 80% of the rated speed because single The centrifugal switch of the phase motor will not be cut off at low speed, leading to the risk of burning the motor. 2. At present, the forward and reverse rotation of the motor can only be controlled by button, panel, and modbus communication. You can use the VFD in combination with the two videos you see. 3. What is your purpose of using DC converter? 4. If you encounter more troubles, please contact our after-sales team, www.ato.com/contactus
@DemiFlower10103 жыл бұрын
@@ATOcom I'm not interested in the dc converter I just keep seeing it in most the videos. I purchased this for my lathe as I said it's 3hp motor. So if I set this up like I see in those couple videos how long are you saying my motor Will last? And why would single phase input and output vfd control be made if its no good for your motor? Should I return it and purchase a single phase in and 3phase out and get a 3phase motor instead? I idid not know these were not good for single phase motors or I would not of purchased. Because On a lathe I'll probably be using the lathe speed less than 80 percent speed all the time so my motor will not last long your saying correct?
@ATOcom3 жыл бұрын
@@DemiFlower1010 1. The low-speed operation time of each brand of single-phase motor is different, which depends on its heat dissipation performance and the separation speed of the centrifugal switch. 2. Single-phase input & output VFD is suitable for single-phase motors that do not run at low speed for a long time, to adjust speed or reduce the impact of the motor on the power grid. 3. If your motor has a long-term use speed lower than 80% of the rated speed without matching the reducer, I suggest that you purchase a three-phase motor and use it with a single-phase input to three-phase output VFD (when running at low speeds, Note that the motor can dissipate heat in time)
@batsaikhanbaterkhes9 ай бұрын
can you give me full circuit diagram pls
@aymansaad74293 жыл бұрын
Good work I have a drive like this It doesn't work A message on screen p. Off No apply for programming how can I do
@sambamurthy8833 жыл бұрын
Saft stater control wireing diagram plz make video sir
@ATOcom3 жыл бұрын
This video, kzbin.info/www/bejne/fZy2oGR6hKd7oq8
@PTinvest3 жыл бұрын
What role of the relay
@ATOcom3 жыл бұрын
Low voltage control high voltage
@runbou34852 жыл бұрын
អរគុណបង🙏
@shreelaser46852 жыл бұрын
how can we control vfd using only limit switch
@judemanoharan18633 жыл бұрын
Please send the credit wiring details
@dilipdande1343 жыл бұрын
Good job.. Thanks allot..legends
@MichealJana Жыл бұрын
nice work
@camron26745 жыл бұрын
I know the objective of the video was to get remote push buttons to control VFD. So I assumed you entered the other parameters like voltage and hertz before this video was recorded...?