I will want to thank again for taking out your time to detailed everything about converting of a UPS to a mini Inverter , we were able to built one through your direction here and it has been working up till date. The first one we built heated up but we were about to discover that the UPS had some circuit issue prior to our using it , so we had to provide another one and it has been working effectively up till date. Thank you for the lecture, people hardly give enough you you did Sir
@CebtechEngineering7 ай бұрын
You are welcome
@CebtechEngineering Жыл бұрын
Kindly like, subscribe and turn On the notification bell to be notified whenever I upload my videos. Have it at the back of your mind that someone you know; your brother, your kids, wife, husband, siblings coworkers or anyone you know that may have great need of this firsthand great unfiltered information. Going through my videos is equivalent to training yourself without any payment. Please keep On following as I would be rolling out lots of videos. Thanks for watching.
@chidilamberto3353 Жыл бұрын
I will be glad to learn more. I am passionate about these ideas
@CebtechEngineering Жыл бұрын
Great to know that
@C-TRO123410 ай бұрын
Thank you so much for sharing this knowledge with us. I am definitely trying this
@CebtechEngineering10 ай бұрын
Sure! please proceed
@mrkokolisso10 ай бұрын
thanks for sharing your information.. Blessings from Mexico!!!
@CebtechEngineering10 ай бұрын
You are welcome
@distinguishedmrtitus Жыл бұрын
very simple and well defined
@CebtechEngineering Жыл бұрын
Thanks bros
@BernardEzeora Жыл бұрын
Thanks for the information so far , this is doable
@CebtechEngineering Жыл бұрын
You are welcome
@StephenOmisore7 ай бұрын
Well done my brother 👍
@lagswaggzz7 ай бұрын
How long can it run without charging?
@calsmith79023 ай бұрын
Great information 👍 ... HORRIBLE MUSIC 😢
@nnamdi.ohaegbuchi10 ай бұрын
How to switch off the alarm?
@k-sell40659 ай бұрын
If you are brave enough.go inside where the buzzer is located. It run off dc power of 12 volts. Desolder the buzzer and replace it with a 5 to 10 ohm risistor in place of the buzzer with no sound 😊
@k-sell40659 ай бұрын
Some models you have to hold down one of the buttons to disable the buzzer alarm 😊
@LHARYTECH25 күн бұрын
Sir, can I use Lithium batteries in place of lead acid?
@pantherat23238 ай бұрын
Hi, how did you overcome the over heating of the transformers? Thanks in anticipation of your response
@CebtechEngineering7 ай бұрын
Check to see if the UPS you used is in good other or you can actually upgrade to 1200watts or above : 1200w has two transformer of 24V connected in series
@teddymoore88957 ай бұрын
Link on how to upgrade 600w to 1200w using two ups pls
@CebtechEngineering7 ай бұрын
No ! Not using two , use one UPS of 1200W
@pantherat23237 ай бұрын
I have a 2200w UPS how many Watts do you reckon I can safely draw from it without causing overheating
@nelsoncruz72786 ай бұрын
@@pantherat2323 2200w for starting but 1200w - 1500 should be okay without any issues
@JosephBlessing-hk2ck3 ай бұрын
❤❤I appreciate you sir but how did you convert it from ups to inverter...n how can I use solar panels to power it???
@michealmarny3133 ай бұрын
Can you guide on how to bypass the auto shut down of the ups
@TheKingsCrownGlobalMissionsMPi Жыл бұрын
Thank you so much. I will do it
@CebtechEngineering Жыл бұрын
You are welcome brother
@omegagleam35283 ай бұрын
Nice one boss, it works but it doesn't last long why
@fidelischidebere-li1gp7 ай бұрын
How can you charge it
@CebtechEngineering7 ай бұрын
The UPS charges the battery once connected to source voltage and when not in use.
@k-sell40659 ай бұрын
A lot of the ups requires them being hooked up to a computer In order to set them without a manual button to shut them off.
@storytell1 Жыл бұрын
How do I use solar panels
@CebtechEngineering Жыл бұрын
You will need to do that through a charge controller; I au have to do a video on that
@CebtechEngineering Жыл бұрын
Very soon
@dPatai71 Жыл бұрын
I use 500wc solar panel + 40A charge controller + 2x12v-200AH batteries + APC Back-ups. Working well 24h/7days
@CebtechEngineering Жыл бұрын
@@dPatai71 Nice one! More of sure report please, we can do more than the above
@jgbelmont10 ай бұрын
Sun
@udochukwujohn387510 ай бұрын
Good morning Sir, I have a UPS 2000va but the power is not coming on
@CebtechEngineering10 ай бұрын
Ok I suggest you fix the UPS first before using it
@elizabethezeoranu16848 ай бұрын
Secondly the Alarm was a problem initially but we had to use a sharp object and punch it to stop
@CebtechEngineering7 ай бұрын
Good job
@chidilamberto3353 Жыл бұрын
Let's say I don't want to store energy in the battery first. Is it possible to draw energy directly from solar panel and connect to the UPS during a sunny day? Will it give me a current while sunshine lasts?
@CebtechEngineering Жыл бұрын
Yes!
@chidilamberto3353 Жыл бұрын
@@CebtechEngineering I did it today but the UPS didn't start. I used a 12v solar panel. What could be the problem
@chidilamberto3353 Жыл бұрын
Can I send u a direct message with a picture of my set up
@YoungDadoffgridsolar Жыл бұрын
@@chidilamberto3353you still need a battery connected to the ups if you want to use the solar panel
@adeloyeayomide51714 ай бұрын
You should use Charging controller with it @@chidilamberto3353
@emperortv466910 ай бұрын
Can one introduce Solar panel to this setup, with and without battery?
@mahmudonimisi29999 ай бұрын
You can introduce solar panel to the system but not without a battery and a solar charge controller. The essence of solar panel is to use sunlight to charge the battery in order to replace the energy loss from the battery during the conversion from a DC to an AC current with the inverter or UPS.
@nnamdi.ohaegbuchi10 ай бұрын
How to switch off the alarm
@CebtechEngineering10 ай бұрын
Simply desolder the alarm if you have the time , if you don’t use a sharp object to punch the Alarm or force a masking tape inside the hole to cover it
@dannystrachan475 Жыл бұрын
The quickest and easiest way to silent the annoying alarm is to push prestix into the hole.
@CebtechEngineering Жыл бұрын
Yea!
@Ttechcraft9 ай бұрын
@@CebtechEngineeringbut car battery doesn't last
@ericdion297610 ай бұрын
How long can it last when you on it
@CebtechEngineering10 ай бұрын
Ok, note that the lasting of the power supply is directly depends on the capacity of the UPS ,the Battery and the load
@Ali-gt3tt5 күн бұрын
I did this method, but the UPS charging capacity is weak, which leads to the battery weakening and being damaged in the future.
@ogeonyia7558 Жыл бұрын
Weldon Engr
@CebtechEngineering Жыл бұрын
Thanks much
@nnennaanyadiegwu3895 Жыл бұрын
Wow didn't know you could that.
@CebtechEngineering Жыл бұрын
Thanks so much
@nelsoncruz72789 ай бұрын
My brother, please dont touch battery while the ups is ON, if you try it with 48v or 24v battery it will shock you
@AlindaGladys Жыл бұрын
What of, if I connect with 100Ah battery will it be stable or
@isaacking64239 ай бұрын
Yes, it'll increase ur battery capacity
@quickfixengineeringltd80352 ай бұрын
Please can it power a fridge
@CebtechEngineeringАй бұрын
Not with the current illustrated UPS Thanks
@jgbelmont10 ай бұрын
Efficiency 70%. Real inverter 85+%. Your choice.
@CebtechEngineering10 ай бұрын
Sure MOSFET differences and arrangement
@nonyezeran7247 Жыл бұрын
❤
@ShedrackOnwube8 ай бұрын
My ups inverter power off once the battery is 10.4v but my 500w sachet inverter work till 10.0v
@CebtechEngineering7 ай бұрын
It could possibly be the cut off time for the PIC component embedded in the UPS
@BizzyG4 ай бұрын
It's the way the UPS was programmed to operate. That's its cutoff voltage to prevent the battery from dieing due to excess drain.