How to detailed step by step proper way to install HVAC duct training

  Рет қаралды 195,202

SaveGreenHere

SaveGreenHere

Күн бұрын

Пікірлер: 120
@c.paulsen2708
@c.paulsen2708 10 ай бұрын
I know this is two years old but after watching a bunch of videos, this was the only one that was actually helpful. Thank you!
@SaveGreenHere
@SaveGreenHere 10 ай бұрын
Great to hear!
@sendeth
@sendeth Жыл бұрын
Probably the best video on how to do this that I have seen yet
@SaveGreenHere
@SaveGreenHere Жыл бұрын
Thanks!
@VileWhiteMeat
@VileWhiteMeat Жыл бұрын
Appreciate the detailed video. Saved me some cash of paying to have this done. My kids thank you as well now their room won’t be hotter than the rest of the house.
@SaveGreenHere
@SaveGreenHere Жыл бұрын
Glad it helped!
@kevintoledo4445
@kevintoledo4445 Жыл бұрын
Such a great video, very well explained. I’m new into HVAC and haven’t learned much about ducts, and this was very informing
@SaveGreenHere
@SaveGreenHere Жыл бұрын
Glad it was helpful!
@melissabarragan2367
@melissabarragan2367 Ай бұрын
Thanks for making such a detailed video. We just converted our garage into living space, and this video is exactly what we needed to add ducts and boots to the new space
@SaveGreenHere
@SaveGreenHere Ай бұрын
Glad it was helpful!
@ashbucharon8263
@ashbucharon8263 Жыл бұрын
Wow! Congratulations, everything taught in great detail in the most efficient manner. Thank you Maestro and God Bless
@SaveGreenHere
@SaveGreenHere Жыл бұрын
So nice of you!
@chcou3125
@chcou3125 Ай бұрын
What an amazingly detailed video with top notch advice! Thanks for taking the time to share!!
@nancyulloa4807
@nancyulloa4807 9 ай бұрын
You are a Great instructor (step-by-step) teaching all the steps to do the task. Thank You
@SaveGreenHere
@SaveGreenHere 9 ай бұрын
Glad it was helpful! Thanks for subscribing!
@driesnijenkamp6399
@driesnijenkamp6399 8 ай бұрын
This is the greatest video of all time! Great filming, fantastic execution, cool dude.
@SaveGreenHere
@SaveGreenHere 8 ай бұрын
Wow, thanks! Please support and SUBSCRIBE!
@stpvideos92203
@stpvideos92203 7 ай бұрын
Wish I could’ve seen you tape down the outer layer. Love the video. Thank you so much.
@SaveGreenHere
@SaveGreenHere 7 ай бұрын
Next time! Thanks for the support!
@ericbaker2514
@ericbaker2514 4 ай бұрын
One more quick tip if you use duct sealer on the inside of the takeoff you will seal in all of that fiberglass ps I do systems with 3% air loss I only tape the flex to the takeoff and put a zip tie putting the sealer on the inside first is going to be extremely messy especially for somebody that is not skilled in this trade just food for thought by aluminum tape works fine I've done hundreds of homes and pass with 3% air loss which is what they want in an energy star home
@SaveGreenHere
@SaveGreenHere 4 ай бұрын
Great! Thanks!
@petesingh292
@petesingh292 Жыл бұрын
This type of work should be taught in trade schools amazing video
@SaveGreenHere
@SaveGreenHere Жыл бұрын
Appreciate the love! Feel free to share!
@vikingrobot4179
@vikingrobot4179 Жыл бұрын
Excellent how to. Thanks helped a lot.
@SaveGreenHere
@SaveGreenHere Жыл бұрын
Much appreciated!
@potentialhvac6074
@potentialhvac6074 Жыл бұрын
Ph1s/Ph2s and adjustable elbows with blocking or snipping tabs out of Boot tend to be make for much better air flow and distribution out of register and make securing the register better too. However those B-box do make it a whole lot quicker and easier 👍🏽
@SaveGreenHere
@SaveGreenHere Жыл бұрын
Thanks!
@eliviv3949
@eliviv3949 Жыл бұрын
This might vary by state, but when, mounting this way on the ceiling from the attic, are you required by code to use metal boot rails to fasten it to the studs?
@SaveGreenHere
@SaveGreenHere Жыл бұрын
Only in new construction. Retrofit application is different, as drywall is already laid out.
@ArmedTherapy017
@ArmedTherapy017 Ай бұрын
Can you show the whole system from the main Plenum?? question is…are you using the flex duct for the whole system? I was researching and I read that you’re not supposed to use flex duct longer than 5 to 7 feet. I’m in Florida and it looks like in the attic they use it on everything … just curious what’s correct. thank you.
@bmanmitch2005
@bmanmitch2005 Жыл бұрын
At 16:34 into the video, You didn't say what the white sealant is , is it Mastic or the regular sealant/caulk?
@SaveGreenHere
@SaveGreenHere Жыл бұрын
amzn.to/3rhTJ3l
@ShockinglySimple
@ShockinglySimple Жыл бұрын
@ 16:31 what is the weather stripping used for the register box?
@SaveGreenHere
@SaveGreenHere Жыл бұрын
Just an added layer to create an airtight seal.
@arturogonzalez9555
@arturogonzalez9555 7 ай бұрын
Just what I was looking for. Thanks, be blessed always
@SaveGreenHere
@SaveGreenHere 7 ай бұрын
You're welcome 😊
@diaperdood1
@diaperdood1 Жыл бұрын
The exposed fiberglass fibers won’t go airborne into the rooms?
@SaveGreenHere
@SaveGreenHere Жыл бұрын
If the duct is sealed properly, no fiberglass from the attic should enter the living area, When cutting fiberglass rigid duct board, you can simply use a shop fav near while another person cuts it, to avoid spreading the fibers.
@diaperdood1
@diaperdood1 Жыл бұрын
@@SaveGreenHere what about the fiberglass in that drop register
@SaveGreenHere
@SaveGreenHere Жыл бұрын
As mentioned, simply use a shop vac near while another person cuts it, to avoid spreading the fibers.
@markLikesSports
@markLikesSports 7 ай бұрын
To reduce resistance, it would be better to use a rigid tapered 90 degree or similar connector between the register and the flex duct (24:30). Also a tapered connection off the plenum. Otherwise, great video and camera work!
@SaveGreenHere
@SaveGreenHere 7 ай бұрын
Thanks for the comments! In the past, we actually used the collars, but find them to be extremely leaky and hard to insulate, thus causing condensation, and eventually mold with the extreme temperature differences between the conditioned air, and the extreme unconditioned space. But if the attic has spray foam, for example, we use the type that can be maneuvered, like this one..... amzn.to/49UIjZO
@markLikesSports
@markLikesSports 7 ай бұрын
@@SaveGreenHere Hi there. Actually I was referring to a non-adjustable collar which has much less leakage. You can also fabricate them out of semi-rigid flex duct pretty easily and they don't have to be long, just enough to have the bend be well supported and protect it from crimping. You can see what I mean in Manual D group 8 "elbows and offsets". Its the smooth rounded elbow and the equivalent length is very low. You can pull the flex duct over them to the register so insulation shouldn't be too much of a problem.
@jerrynonofbss2588
@jerrynonofbss2588 5 ай бұрын
Just use a strap to hang the flex duct on the truss.
@SaveGreenHere
@SaveGreenHere 5 ай бұрын
This is the one we use for flex systems........ amzn.to/4ciqOEA and for metal........ amzn.to/4eIKao0 use the holes to hang onto rafters or drill onto metal beams on steel buildings.
@VileWhiteMeat
@VileWhiteMeat Жыл бұрын
Thanks!
@SaveGreenHere
@SaveGreenHere Жыл бұрын
Thank you!
@scubajasona
@scubajasona Жыл бұрын
Great video, much thanks! However my register screws hit the sheet metal on the register. Did you drill pilot holes into the sheet metal? Or am I supposed to wooden frame the register so the register screws have somewhere to bite other then drywall? This is a ceiling register 10x10 and don't want it to fall.
@SaveGreenHere
@SaveGreenHere Жыл бұрын
The sheet metal has a "series" of tiny pilot holes to help securing the register to the ceiling, via securing the register to the metal of the boot assembly.
@TrueHearted78
@TrueHearted78 10 ай бұрын
Also. Couldn't you put seal around box lip where lip side meets ceiling floor as well? Before screwing box down.
@SaveGreenHere
@SaveGreenHere 10 ай бұрын
Yes u can
@Anonsbdofjrnwodb
@Anonsbdofjrnwodb Ай бұрын
None of the box stores sell vent duct boxes like that with the screwing flange. All of the ones they sale are just the box itself with new mounting brackets (the pieces on the end with the screw holes)
@SaveGreenHere
@SaveGreenHere Ай бұрын
Get it here..... amzn.to/4e4d6oV
@salemadnan8884
@salemadnan8884 2 ай бұрын
Great video! Thank you
@SaveGreenHere
@SaveGreenHere 2 ай бұрын
Glad you liked it!
@Jumpoutdre
@Jumpoutdre 5 ай бұрын
Bros a unit grabbing that fiber glass bare handed!
@SaveGreenHere
@SaveGreenHere 5 ай бұрын
Just don't touch your face after ha ha.
@masontroglen3413
@masontroglen3413 Жыл бұрын
I would say dont slide.duct.on too far. Just maybe finger width also spray glue for the tape.
@SaveGreenHere
@SaveGreenHere Жыл бұрын
👍
@marcelosantana9311
@marcelosantana9311 Жыл бұрын
Great video, not in the trade but love learn new stuff. I am still waiting to find out when do you need to use spray the foam. 😂 Also, I have the “M” around one vent in the closet. Any tip how to insulate to prevent moisture? I got in the attic in the past but could find any roof leak so pretty sure it is condensation despite everything looks sealed.
@SaveGreenHere
@SaveGreenHere 9 ай бұрын
You can apply small amounts of spray foam to cover the metal boot in unconditioned space to prevent moisture and mold that can occur in extreme temperatures. Use the type that expands minimally. I love using this one...... amzn.to/3wD5gCB
@vadymbabaiev5644
@vadymbabaiev5644 2 жыл бұрын
Fantastic video!👍
@SaveGreenHere
@SaveGreenHere 2 жыл бұрын
Thank you very much! Please subscribe and share!
@envieddesigns
@envieddesigns 8 ай бұрын
Can you use duct work aluminum tape to seal around the edges of the sheet rock where the registers meet the sheet rock to keep any attic air from leaking into the conditioned space?
@SaveGreenHere
@SaveGreenHere 7 ай бұрын
Tape does not provide an airtight seal, so the answer is NO. The adhesive on the tape also comes loose in extreme heat, extreme cold, which is what you see in unconditioned spaces. Best you use this............ amzn.to/3TCgW1r
@envieddesigns
@envieddesigns 7 ай бұрын
Thanks, I used mastic and tape in the unconditioned space on duct work connections something the installers failed to do. I meant in the living space the register vent that goes on the wall or ceiling I’ve seen installers applying the foil tape there were the vent meets the sheet rock before installing the vent faceplate.
@deetimeless5836
@deetimeless5836 7 ай бұрын
expanding spray foam would be a far better idea.
@betancourtjrz
@betancourtjrz 9 ай бұрын
What is the ideal duct size? I need to replace it in my home and are going to use the flex duct but dont know if 6 or 8 inch give enough air flow.
@SaveGreenHere
@SaveGreenHere 9 ай бұрын
Check out these videos, as there are many variables when sizing........ kzbin.info/www/bejne/qWfUoailbqqqjtE and studio.kzbin.info1r3zUzhnqk0/edit
@ashbucharon8263
@ashbucharon8263 Жыл бұрын
Excellent, just what I needed, thank you and God Bless
@SaveGreenHere
@SaveGreenHere Жыл бұрын
Glad it was helpful!
@SaveGreenHere
@SaveGreenHere Жыл бұрын
New 470a refrigerant that replaces 410a refrigerant, with Do-It-Yourself kit included..... ebay.us/tVSqEv
@jackprick9797
@jackprick9797 2 жыл бұрын
Great video. Thank you.
@SaveGreenHere
@SaveGreenHere 2 жыл бұрын
Thank you!
@idanny76
@idanny76 2 жыл бұрын
I have high static pressure on a new 3.5 ton heat pump. I know for sure the flex duct is the issue. I have two 12" coming out of the supply in opposite directions. I know I need an 18" for a 3.5 ton heat pump. I did a diagram layout of the duct in the attic. What would happen if I just replace the two 12" to 18"? Ignoring the downstairs, because everything is between the walls. The problem was even worse with an undersized return. The original and only return was a 24x18. The total static pressure on the unit was .9 W.C. I was able to drop the TESP to .66 by making the return 30x24. Since there is so much static pressure and the unit TESP is a .2 and I need an 18" for a 3.5 ton for 1400 CFM. How big does the supply plenum should be and what shape? Should the supply plenum split to 3 18" going out to each of the 3 distribution boxes? Do the other three distribution boxes also need to be larger? Looking at the triangle shaped supply plenum I have very little room up for a rectangle plenum. I think a 3 feet ductboard supply plenum should work. There is a foot from the Air handler to the ceiling and I think 2 feet from the attic floor to the roof. Now I am looking at two types of designs. Design #1 keeps the 18" ducts straight by having a single 18" coming out of the supply and then a distribution box splitting it to three 18". The sides would be coming out straight to the to side boxes and one going to the third box with a slight curve. Design #2 splits to three right at the supply plenum and goes to each box individually, but all three will have a slight curve. I will not be using any metal plenums..... it will be all flex duct and ductboard boxes, because of budget. I am not trying to make a perfect system, but trying to remove the restriction from the 12" undersized ducts installed and replacing the flex duct that was patched with mastic with new ones. Another question about the installation..... I have the flex duct running up and strapped to the roof for support. Since the supply plenum is low to the floor due to the roof..... Can the flex duct be run on the attic floor? Can you tell me which layout makes more sense and less restrictive? Thank you. Layouts: Current i.ibb.co/Ld9kmPM/Flex-Duct-Layout-and-Size.jpg Option #1 i.ibb.co/GHyS00g/2022-07-05-0002.jpg Option #2 i.ibb.co/PNN8mSB/2022-07-05-0001.jpg Air Handler Specs ibb.co/17VvF4B Video of attic kzbin.info/www/bejne/n3rReoFubtZrfbc
@SaveGreenHere
@SaveGreenHere 2 жыл бұрын
Almost seems like two 18" flexes will affect static, but the other way around, as they will be waaaay too big. Return seems fine after your increase. However, make sure the actual return chase is wide enough, not just the grill or wall opening. You may want to check the condition of the coil. A dirty, or obstructed coil, WILL affect your static. Pertaining to the question on changing the boxes, and other ducts, yes, if those are not changed, your static will still be off. So the boxes, and the ducts coming off the boxes need to be upsized, accordingly, to accommodate the increased CFM coming into them as well. I did a simple video for customers, years ago, and that may help...... kzbin.info/www/bejne/raqncoJqa5abbJo
@idanny76
@idanny76 2 жыл бұрын
@@SaveGreenHere what do you mean by two 18" flexes will affect static? In a positive or negative way? Right now is undersized. I have a 3.5 air handler with 1,400 CFM and it's going out the supply to two 12" flexes. For a 3.5 ton heat pump it requires 18", which would reduce static pressure. The return is completely open inside. I can go in it and clean the coils from underneath. It's not the grill or wall widen, but the whole area underneath. The units is not a year old and coils are clean. The static pressure at the return is just 1.5 WC with the filter. Its also a 3" depth filter which is less restrictive. The static pressure at the supply is .50. originally with the old undersized return the TESP was .9 WC.... It was almost 1. I was hoping to try keeping the other extension the same size and just put in a bigger supply trunk plenum, replace the 12" to 18" and send 3 18" to each distribution box. I didn't know which of the layouts is best or if you had other suggestions. I am not trying to get a perfect balance system. I was hoping to just reduce the static pressure drastically like I did with the return. Remove the pressure from the blower motor.
@SaveGreenHere
@SaveGreenHere 2 жыл бұрын
I would personally use a ductulator like the ones shown on the video I referenced....... amzn.to/3yiBK2d Or an online one like this one.... www.oceanhvac.com/ductulator/ But from my experience, two 18" round flex ducts will easily both be topping over 2300 CFM. Too big for a 3.5 ton air handler. Check the speed of your blower as well.
@edgardlebrun8441
@edgardlebrun8441 Жыл бұрын
Best video ever ..great job
@SaveGreenHere
@SaveGreenHere Жыл бұрын
Thank you so much 😀
@VictorGonzalez-je4ob
@VictorGonzalez-je4ob Жыл бұрын
Would I be able to do that same process on a ceiling tile?
@SaveGreenHere
@SaveGreenHere 11 ай бұрын
Depends how strong your grid is installed.
@jeffdarnstaedt8397
@jeffdarnstaedt8397 Жыл бұрын
Nicely done- hey I like that double stick tape idea and you mentioned that you would post a link to brand and where to buy but I don't see that here...Can you provide info?
@SaveGreenHere
@SaveGreenHere Жыл бұрын
Yes...... amzn.to/3H72rwH
@erickapanayi5630
@erickapanayi5630 Жыл бұрын
I have this in my home (the fabric stuff) and there is white stuff on it, almost like spray paint... is paint something y'all use on the inside or is it the "M" word??
@SaveGreenHere
@SaveGreenHere Жыл бұрын
Spray paint is usually not used in Duct applications.
@FroppyWoppy
@FroppyWoppy Жыл бұрын
Could be mastic. It helps to seal
@roba2722
@roba2722 9 ай бұрын
The duct adhesive in the amazon link is acrylic yet you said you prefer water based.
@SaveGreenHere
@SaveGreenHere 9 ай бұрын
I checked again and it's water based, red devil.
@domeniclarosa6156
@domeniclarosa6156 Жыл бұрын
Stupid question, what does the grill screw into?
@SaveGreenHere
@SaveGreenHere Жыл бұрын
The metal can unit in the attic, through the drywall.
@markLikesSports
@markLikesSports 7 ай бұрын
Not sure why but my response has been deleted multiple times so I will try to post it as a new comment: Hi there. Actually I was referring to a non-adjustable collar which has much less leakage. You can even fabricate them out of semi-rigid flex duct pretty easily and they don't have to be long, just enough to have the bend be well supported and protect it from crimping. You can see what I mean in Manual D group 8 "elbows and offsets". Its the smooth rounded elbow and the equivalent length is very low. You can pull the flex duct over them to the register so insulation shouldn't be too much of a problem.
@SaveGreenHere
@SaveGreenHere 7 ай бұрын
Thank you.
@markLikesSports
@markLikesSports 7 ай бұрын
@@SaveGreenHere Looks like my comment reappeared below after a couple of days. Maybe a youtube glitch. Anyway, thanks for the videos!
@masontroglen3413
@masontroglen3413 Жыл бұрын
Good stuff
@SaveGreenHere
@SaveGreenHere Жыл бұрын
Appreciate it
@playinghookywithdavidchapa387
@playinghookywithdavidchapa387 5 ай бұрын
I know this is going to sound crazy but i want to do this for my garage. I live in south texas and air flow sucks in my 2 car garage and i would love to do some work in it. Do you think its worth adding a duct to my garage and if so, what size?
@SaveGreenHere
@SaveGreenHere 5 ай бұрын
Well, if you supply air to any room, you also need a return. Not having a return is like running your unit with a window open. The air will simply not return to the unit to be re-conditioned. That being said, doing this in a garage is actually a DANGER because of possible carbon manoxide, and fumes such as paints, gasoline, and others. Your best solution is to install one of these for under $400..... amzn.to/3KSguY1 Search my youtube, as we have various videos on them.
@patrickcarnahan2758
@patrickcarnahan2758 4 ай бұрын
I hope you are talking about a system dedicated to the garage. that is a major violation to install ductwork into a garage from the system feeding the house. Very dangerous because of carbon monoxide from vehicles.
@michaelh.mcginnis1568
@michaelh.mcginnis1568 Ай бұрын
Is it possible to put in a window a/c unit? If so, that is probably your best bet.
@SaveGreenHere
@SaveGreenHere Ай бұрын
Actually, a mini split is better. amzn.to/4fKp34D
@IVfun
@IVfun 5 ай бұрын
I am buying my stuff from your referral link. Good stuff
@SaveGreenHere
@SaveGreenHere 5 ай бұрын
I appreciate that. Thanks again!
@octaviomunoztello7695
@octaviomunoztello7695 6 ай бұрын
Really helpful. Thank you
@SaveGreenHere
@SaveGreenHere 6 ай бұрын
Glad it was helpful!
@burningbrain2977
@burningbrain2977 4 ай бұрын
Did I miss where the spray foam went??
@jorgenorman8715
@jorgenorman8715 4 ай бұрын
I know he said it would be utilized but I’m thinking that was a mistake he left a note text on the video to correct it instead of refilming. It said “it’s optional if coming in from the floor to seal gaps. Not practical for ceilings though”.
@kirkstaggs9773
@kirkstaggs9773 5 ай бұрын
2" ! When it counts!
@dineshbhoibhoi583
@dineshbhoibhoi583 Жыл бұрын
Sir you have vacancy I am hvac air conditioner duct fitter 15 years experience Gulf country in Kuwait
@Erilolen
@Erilolen 8 ай бұрын
Hi, how can we contact you for business inquiry?
@SaveGreenHere
@SaveGreenHere 7 ай бұрын
We don't do business online, sorry.
@SaveGreenHere
@SaveGreenHere 7 ай бұрын
We do not conduct business online. Sorry.
@Erilolen
@Erilolen 7 ай бұрын
Thanks for your reply. You're so nice!
@philipgauthier3570
@philipgauthier3570 Жыл бұрын
I cringed while watching this. I had an entire new system installed in my home and I know they didn't do 1/2 the things you did. I get all sorts of smells from the attic in the home. Excessive dust...It's a nightmare....
@SaveGreenHere
@SaveGreenHere Жыл бұрын
Unfortunately most "new construction" duct installs are done wrong, including wrong smaller sizes, as they are cheaper. The results is an undersized duct system. So you may have a 4 ton HVAC system with 3 tons of ducts, as far as sizes go. This video goes over duct sizing....... kzbin.info/www/bejne/raqncoJqa5abbJo
@philipgauthier3570
@philipgauthier3570 Жыл бұрын
Much appreciated. I'm going to have the system all taken out and completely re-done. I just need to find the right contractor. @@SaveGreenHere
@mississippiqueen2164
@mississippiqueen2164 9 ай бұрын
Here's a valuable tip: The new metal duct is so thin that dropping an 8" elbow to the floor will destroy it, don't ask me how I found out. Today's duct is NOT your father's. Maybe two is better.
@SaveGreenHere
@SaveGreenHere 9 ай бұрын
There are thicker mil out there, but of course, cost more.
@jerrynonofbss2588
@jerrynonofbss2588 5 ай бұрын
SaveGreenHere, do you know a good site to learn to calculate the sizes of the flexduct?
@SaveGreenHere
@SaveGreenHere 5 ай бұрын
Here's a video on duct calculating duct sizes. kzbin.info/www/bejne/Z6OWq4iwndOkoZI You will need to purchase this kit.... amzn.to/4eMja71
HVAC Contractors Hate Me For Showing You This
22:34
Ambition Strikes
Рет қаралды 510 М.
Performance Duct Design & Installation: Advanced DIY
46:23
Home Performance
Рет қаралды 310 М.
黑天使只对C罗有感觉#short #angel #clown
00:39
Super Beauty team
Рет қаралды 33 МЛН
Deadpool family by Tsuriki Show
00:12
Tsuriki Show
Рет қаралды 7 МЛН
How To Install Ductwork In A Basement | DIY Finished Basement Renovation
32:16
HVAC Ductwork Basics! Trunk Duct Fittings, Elbows, Names, Sizes!
13:17
AC Service Tech LLC
Рет қаралды 200 М.
DIY How To Install A Heat Duct Going To The Floor in Your Basement
10:47
Home RenoVision DIY
Рет қаралды 710 М.
Repair Or Replace Your HVAC Flexible Duct System And Save a Fortune
21:02
HVAC Talkshow and Review For Homeowners & DIY
Рет қаралды 5 М.
3 HVAC Ductwork ISSUES Homeowners NEED To Know!
8:06
HVAC Guide for Homeowners
Рет қаралды 436 М.
How to Run Permanent Temporary Power to a Shed
48:30
Home RenoVision DIY
Рет қаралды 1,1 МЛН
DIY Central Air Install for $3300 (Including Tools!)
40:43
LRN2DIY
Рет қаралды 401 М.
黑天使只对C罗有感觉#short #angel #clown
00:39
Super Beauty team
Рет қаралды 33 МЛН