How to dismantle air condition outdoor unit without gauge.

  Рет қаралды 409,471

Chip Channel

Chip Channel

Күн бұрын

Пікірлер: 316
@redpost2380
@redpost2380 3 жыл бұрын
This gentleman is to be thanked for the effort of making a video. The technique has many flaws. Use a proper spanner set not an adjustable wrench as the caps can be very tight. Also, with the other hand hold the valve stem with an adjustable wrench when you remove the caps. Pipe stems can bend and even brake, something that this gentleman is ignoring.The air con unit must be placed on COOL setting not heating setting BEFORE you decommission the external unit. Run for at least 5 -10 minutes. If possible place an air heater in front of the internal unit to warm up the evaporator coil. With the hex key break the seal (as the valve will be fully back seated) of the liquid line (HP) valve (1/4" pipe). NOTE at 2:22 in this video when he closes the liquid line, the copper pipe ices up. This tells you that the liguid refrigerant in the pipe is now evaporated. You need to allow all the liquid to evaporate. Run for a few minutes. He runs it for under 2 minutes. may not be enough. You will hear the compressor noise changing as it sucks all the vapour in the compressor circuit. You need to give the liguid refrigerant time to evaporate(in the evaporator that is why the heater will help). Close the gas vapour valve (front seating it) (LP)(5/8" pipe). Ensure both valves are tightly closed. Don't overdo it. Remove the copper pipes and IMMEDIATELY place masking tape to fully cover the valves and the pipes!!! Do not use bubble wrap like this gentleman did. NOTHING must contaminate the pipes or valves. Place the caps back on. Also useful to bring a spray bottle of soapy water to spray on the valve once it is closed to check for leaks. The professionals will use a manifold to decommission the external unit. It allows you to monitor the gas flow and to understand if there is more liquid gas in the evaporator. If the unit is very old it is possible that the valves leak. when you break the seal at the beginning, place soapy water all over the valve and see if it bubbles. If it does. Place the caps back on and call an HVAC pro. Allowing air to enter the condenser when pumping down means that the gas must be removed and disposed of and new gas introduced.
@chipchannel174
@chipchannel174 3 жыл бұрын
Thanks sir for the great explanation.
@kaveritare..
@kaveritare.. 2 жыл бұрын
Is it necessary to release the gas for shifting the outlet
@IsmadiAhmad
@IsmadiAhmad 2 жыл бұрын
@@chipchannel174 i have no gas in the unit. Can i just plug everything off?
@chipchannel174
@chipchannel174 2 жыл бұрын
@@IsmadiAhmad close the valve before dismantle. The best way is to get the gauge and measure before dismantle.
@michaelkrakowski2804
@michaelkrakowski2804 2 жыл бұрын
Hi Excellent comment! Does this procedure apply for Inverter AC as well thanks BTW, I think pipe size is 3/8 not 5/8. (line 10)
@aneshchopra
@aneshchopra 3 жыл бұрын
Tnx bhai aapki help se aaj maine apne 1000 ₹ bacha liye without mechanic 😀😀😀......tnx
@mikekeating
@mikekeating 3 жыл бұрын
.......Putting new siding up........... You just saved me some $$$$.. 👍thank you👍
@DiscoFang
@DiscoFang 3 жыл бұрын
Alternate title: "Man takes 5 mins to realize a Hex wrench works on both ends"
@RatWorks001
@RatWorks001 2 жыл бұрын
Oh come on, it was only 4 minutes. 3:58 seconds in fact... OMG, it was such a relief when it happened. Thanks for the video Chip, it was very interesting.
@bobboscarato1313
@bobboscarato1313 2 жыл бұрын
Yes I was thinking "where did they get this turkey?" lol
@I_am_007
@I_am_007 2 жыл бұрын
Allen key
@chadrayl9648
@chadrayl9648 Жыл бұрын
Horrible
@ANTONYBROWN-jl8fx
@ANTONYBROWN-jl8fx 8 ай бұрын
​@@bobboscarato1313p00
@ivispimienta9243
@ivispimienta9243 2 жыл бұрын
Congratulations sir. Very useful this video. Thanks a lot for taking your time to share this valuable information. Thanks
@bobboscarato1313
@bobboscarato1313 2 жыл бұрын
It was a terrible video; very unprofessional..!
@VernonGovender-db4tg
@VernonGovender-db4tg 7 ай бұрын
Thank u I learnt something from you I did try to remove the unit in a different way and did not work now will use ur video ...
@isumiterracetv506
@isumiterracetv506 3 жыл бұрын
Oh, for goodness sake, use the long end of the hex wrench until you have to tighten it. Jeez. Like watching paint dry!
@chipchannel174
@chipchannel174 3 жыл бұрын
The reason why I’m slowly turn the hex wrench because of to ensure all the gas flow into the compressor. It’s not just about to close the valve only.
@isumiterracetv506
@isumiterracetv506 3 жыл бұрын
Yeah, but you finally worked it out towards the end of closing the second valve ;) Anyway, thank you for the video. Most helpful and appreciated. :)
@flattblackjakus
@flattblackjakus 3 жыл бұрын
I found it quite soothing and satisfying lol
@isumiterracetv506
@isumiterracetv506 3 жыл бұрын
hahaha... Good on ya, fella. :)
@JosuRibeiro
@JosuRibeiro 3 жыл бұрын
@@isumiterracetv506 I was frustrated too... do we need to watch. Every. Single. Turn. Of. That. Wrench?! hahaha but great video tho
@SenthilKumar-gz1ll
@SenthilKumar-gz1ll 2 жыл бұрын
anna amazing explaination step by step instructions very thanking sir
@chipchannel174
@chipchannel174 2 жыл бұрын
Welcome
@johnjosephpuntual1264
@johnjosephpuntual1264 7 ай бұрын
thankyou, very simple, and very clear to understand
@garvinjohnson437
@garvinjohnson437 3 жыл бұрын
I see in the Bahamas where I live the close the big line first then turn the ac on let it run for about a minute or 2 then turn the unit off then close the small line
@punampandit1785
@punampandit1785 2 жыл бұрын
Thanks for helpful video Love from Nepal
@jordanoliveros3510
@jordanoliveros3510 2 жыл бұрын
Good job Sir kahit walang audio pero malinao
@chipchannel174
@chipchannel174 2 жыл бұрын
Thank you..
@RDBDallas
@RDBDallas 2 ай бұрын
Thank you for slowing down to show the L Snowflakes how its done.
@buhayjapanvantiw427
@buhayjapanvantiw427 2 ай бұрын
Thank you very much sir,how many times I'll do it myself to dismantle the aircon but i just only remove the cap and close the valve,and the freon gas is out very noisy
@chipchannel174
@chipchannel174 2 ай бұрын
@@buhayjapanvantiw427you are welcome
@kazielbonn
@kazielbonn Жыл бұрын
Waited for ages for the person to switch to the alan wrench's long end.
@krisztianbalazs7839
@krisztianbalazs7839 6 ай бұрын
It is a good video and a huge thank you for it but you can use the long side of the alan key too. :)
@akkioshin715
@akkioshin715 4 ай бұрын
Great video i wish i watched this one before losing all my gas thanks to the other video i watched where he says to wait 30seconds ..
@JleeRoger
@JleeRoger 4 ай бұрын
Me too 😢
@Gganp1
@Gganp1 Жыл бұрын
very good job, please add audio. Rated number 1. Best ever. Thank you you my $500 I would like to send you a gift certificate.
@chipchannel174
@chipchannel174 Жыл бұрын
Wow, thanks!
@praveenmannam3001
@praveenmannam3001 4 жыл бұрын
Its good if you do its continued part for indoor until outdoor & indoor units kept on floor.
@chipchannel174
@chipchannel174 4 жыл бұрын
Praveen Mannam yes I will if I have job to dismantle indoor unit. I will update in my channel. Thank you.
@ariansinanaj8668
@ariansinanaj8668 Жыл бұрын
You have done good job, thank you very much for detailed video.
@diysolaradventures7894
@diysolaradventures7894 Жыл бұрын
Mine's is in heating mode can I pump it down with the heat running ain't that still sending Freon through the lines
@ryel073
@ryel073 3 жыл бұрын
May i ask you sir i have plan to transfer my AC to other room with by my self. Can i just reconnect the two pipe and cup then reopen that 2 supply? Or can you tell me what to do for Reconnecting? !
@chipchannel174
@chipchannel174 3 жыл бұрын
Basically when you want to reinstall or install the AC, you need vacuum and gauge to clear the air inside the cooper pipe from outdoor to indoor. The reason is to ensure your gas is purely and not mixing with air trap inside the cooper pipe to maximise the cooling operation. But you still can do that.
@mdabdulmoiz
@mdabdulmoiz 3 жыл бұрын
i just want to change the direction of my outdoor unit can I do it myself, now you have shown how to unplug but how do I reconnect this back?
@chipchannel174
@chipchannel174 3 жыл бұрын
Usually for installation required vacuum pump to vacuum the air inside the cooper pipe before release the gas. This video just to show how to disconnect the outdoor unit. You may search for others video for installation guideline. Not much different between relocation and install the new AC.
@Dom75GR
@Dom75GR 2 жыл бұрын
Video helped a lot. Just have a question. Is the proccess the same to re install it ?? Or it needs to by done by a pro with special tools ?
@chipchannel174
@chipchannel174 2 жыл бұрын
Installation no need to turn on the compressor as pump down process. Hook up, release the gas and turn on the AC. Probably need to use gauge to check either has enough gas or not. For better results, please consults your local expert.
@jasonkolb1284
@jasonkolb1284 2 жыл бұрын
@@chipchannel174 don't you need to evacuate the evaporator and line set with a vacuum pump?
@chipchannel174
@chipchannel174 2 жыл бұрын
@@jasonkolb1284 Air conditioning vacuum pump is used to remove unwanted air and water vapor from the air conditioning system basically in cooper pipe. Pump down process to move and keep the gas to compressor. Similar to when you buy new AC, the gas already have inside.
@kylekey9619
@kylekey9619 2 жыл бұрын
Thanks for the video.
@chipchannel174
@chipchannel174 2 жыл бұрын
Welcome..
@LS-ki9nl
@LS-ki9nl 3 жыл бұрын
Just what I was looking for. Thanks.
@chipchannel174
@chipchannel174 2 жыл бұрын
You are welcome…
@watchtime9072
@watchtime9072 Жыл бұрын
Brilliant! Thanks for posting.
@joshuacummins2076
@joshuacummins2076 3 жыл бұрын
Do you just do the reverse order to hook it back up. Great video btw!
@chipchannel174
@chipchannel174 3 жыл бұрын
To hook it up with proper way is just need another step which is vacuum the cooper pipe before release the gas. You need to have vacuum and gauge to do this process.
@chipchannel174
@chipchannel174 Жыл бұрын
@Khanh Phan to install new AC I suggest to follow the actual procedure which is you need gauge and vacuum pump. This video just for special case to disconnect your AC without those equipment. Please refer to AC expert on your area.
@hlalthanpuia1494
@hlalthanpuia1494 Жыл бұрын
Good video Sir. Is it required to switch on the ac power before dismantling?
@chipchannel174
@chipchannel174 Жыл бұрын
After pump down completed and all valve are close, you need to turn off the power before dismantle the power cable.
@hlalthanpuia1494
@hlalthanpuia1494 Жыл бұрын
@@chipchannel174 Thank you sir🙏🙏
@boutserk5
@boutserk5 Жыл бұрын
I did it exactly like you said and everything is fine. Thanks
@chipchannel174
@chipchannel174 Жыл бұрын
Welcome
@michaelkrakowski2804
@michaelkrakowski2804 2 жыл бұрын
Hi thanks for the video Does this procedure apply for Inverter AC as well
@chipchannel174
@chipchannel174 2 жыл бұрын
Pump down process required the compressor to run. Should be apply for both system as long as compressor running. Inverter is just providing variable power and speed control to the compressor and fan. This is what Im understanding about the process and system. You may refer to others expert about the AC if you have any concerns.
@dgb5820
@dgb5820 Жыл бұрын
Great video
@chipchannel174
@chipchannel174 Жыл бұрын
Thanks!
@stvn2918
@stvn2918 3 жыл бұрын
Is it necessary to switch on before unmantle?
@chipchannel174
@chipchannel174 3 жыл бұрын
Yes sir. Pump down process need to run the compressor in order to flow the gas.
@R凱這輪上車料
@R凱這輪上車料 4 жыл бұрын
Good job
@chipchannel174
@chipchannel174 4 жыл бұрын
微微 thank you
@hansmaier3689
@hansmaier3689 9 ай бұрын
In case you are in heating mode close gas line and than liquid site?
@chipchannel174
@chipchannel174 9 ай бұрын
This process I just follow the instruction from the service manual for this model. You may refer to your AC model service manual for better view or clarifications.
@JustGeekstuff
@JustGeekstuff 7 ай бұрын
hey man no need to discharge the gas or liquid before you close the valve or remove the copper pipe? huh
@Marsell88
@Marsell88 2 жыл бұрын
Thanks a bunch dude! God bless... Mofos asking for 30-50 euros to dismantle my AC.
@MrBENTPIN
@MrBENTPIN 2 жыл бұрын
Costs.650 to instal one in Australia
@OfficialHowItRuns1.0
@OfficialHowItRuns1.0 5 ай бұрын
Sir how long to wait for gas valve after tightening the liquid valve?
@chipchannel174
@chipchannel174 5 ай бұрын
Depend on AC HP. You can refer service manual for your type of AC.
@delberttips9177
@delberttips9177 2 жыл бұрын
Thank you bro.
@hamsterdogcat
@hamsterdogcat 11 ай бұрын
Thank you sir! But how to make it run again?
@chipchannel174
@chipchannel174 11 ай бұрын
You may refer to others video for installations. .
@elias.anjel8170
@elias.anjel8170 5 ай бұрын
Hi it have turns on on cooling yeah? I followed your steps but fan still not working, can this steps work if the fan not turning? Thanks
@elias.anjel8170
@elias.anjel8170 5 ай бұрын
Or have turned on heating??
@chipchannel174
@chipchannel174 5 ай бұрын
Outdoor compressor need to run for this process. Usually outdoor fan will running if outdoor unit turn on.
@Tamiltech360senthil
@Tamiltech360senthil 3 жыл бұрын
Nice bro
@chipchannel174
@chipchannel174 3 жыл бұрын
Thanks
@adamjones9600
@adamjones9600 Жыл бұрын
Well this work on a vehicle? I would like to remove the ac unit from the vehicle. AC works but car can’t move.
@chipchannel174
@chipchannel174 Жыл бұрын
Basically should be the same process. Could be better you refer to service manual.
@johnrogers1423
@johnrogers1423 3 жыл бұрын
Using the shifting spanner the other way around is less likely to damage the spanner.
@curtissharris8914
@curtissharris8914 Жыл бұрын
what's running and what does ....3 after 5 to 10 minutes mean?
@chipchannel174
@chipchannel174 Жыл бұрын
To let the compressor running and stop the gas flow from outdoor unit to indoor unit.
@xylenesavannah5076
@xylenesavannah5076 Жыл бұрын
what will happen if I just closed all valve without powering the AC for some minutes before do that
@chipchannel174
@chipchannel174 Жыл бұрын
You will lost the gas inside the pipe and indoor unit. This is not a good practice since you will release the gas to the environment. Also it will cost you during installation because need to top up the gas.
@nhojjohn4054
@nhojjohn4054 3 жыл бұрын
It's safe if the liquid is leaking? Thnx the AC is not operating
@chipchannel174
@chipchannel174 3 жыл бұрын
Do you mean leaking caused the AC not working or leaking during dismantle?
@nhojjohn4054
@nhojjohn4054 3 жыл бұрын
During dsmqmtle
@chipchannel174
@chipchannel174 3 жыл бұрын
@@nhojjohn4054 if compressor in running condition means during pump down process should be less possibility or in min qty for leaking but of compressor not running there is another process to release the gas. Main point is do not release the gas to the environment which will contribute to the air pollution. You can search about the process and procedure of release the gas without compressor in running condition.
@unnikrishna4133
@unnikrishna4133 3 жыл бұрын
Thank you is a small word
@chipchannel174
@chipchannel174 3 жыл бұрын
Please share this video if you think this information helpful. Thanks
@fredericsheridan1436
@fredericsheridan1436 5 ай бұрын
When you reinstall the unit is it the same procedure?
@chipchannel174
@chipchannel174 5 ай бұрын
For reinstall you need vacuum to clear the air trap inside the cooper for better results. Procedure should be reverse from dismantle process but you need to check all the connection are good to ensure no leakage.
@noodles806
@noodles806 3 жыл бұрын
Thanks for this! What did you do with the loose power cable after?
@chipchannel174
@chipchannel174 3 жыл бұрын
No longer used. The power cable is from the indoor units.
@noodles806
@noodles806 3 жыл бұрын
@@chipchannel174 I should have been more specific. What did you do to secure/stow it safely since it wasn’t being used after?
@chipchannel174
@chipchannel174 3 жыл бұрын
@@noodles806 power cable units usually connected and follow through the cooper pipe with insulation from indoor to outdoor units. If no longer used it then you can just pull or remove those pipe and cables.
@parisparknarzo
@parisparknarzo 7 ай бұрын
boss kung matagal nang tengga ang generator, kailangan pa ba e power on para maalis ang mga tubo?
@chipchannel174
@chipchannel174 7 ай бұрын
Translate to english please.
@dtb7872
@dtb7872 2 жыл бұрын
Upon reconnect, did you pump down the system yourself and recharge?
@ralistaduncan8092
@ralistaduncan8092 2 жыл бұрын
Thank you very much
@chipchannel174
@chipchannel174 2 жыл бұрын
You are welcome…
@ralistaduncan8092
@ralistaduncan8092 2 жыл бұрын
Please what's the size of the hexagon key ?
@chipchannel174
@chipchannel174 2 жыл бұрын
@@ralistaduncan8092 sorry, I forgot the hex size because I have a set of it. It may varies depend on model.
@ralistaduncan8092
@ralistaduncan8092 2 жыл бұрын
@@chipchannel174 I had a gas come out the small pipe though the hexagon nut was tight, I hope that's isn't a problem , I'd used it a night before dismantling
@ralistaduncan8092
@ralistaduncan8092 2 жыл бұрын
@@chipchannel174 please I have put it back on and won't get cold inside the gas pipe is frozen white is there something wrong with my unit
@RS9World
@RS9World 3 жыл бұрын
Can you do this in heating mode? Will the steps be the same?
@chipchannel174
@chipchannel174 3 жыл бұрын
As I know, during pump down need to run or activate the compressor and usually set to lowest temperature.
@ralistaduncan8092
@ralistaduncan8092 2 жыл бұрын
Please I need help I did the process successfully, I had little gas come out from the pipe from the indoor unit but now I need to put it back, the gas pipe get frozen white and it won't get cold inside is there something wrong with my unit ?
@chipchannel174
@chipchannel174 2 жыл бұрын
Probably not enough gas i think.
@hamzakhattak5365
@hamzakhattak5365 2 жыл бұрын
A question: you tighten up the gas valve first, after the air is changed from hot to normal you again tighten up the valve, is this process can be done 1 time or it should be done in 2 steps?
@chipchannel174
@chipchannel174 2 жыл бұрын
2 steps since the process is to pull all the gas and keep into outdoor unit. If one time you will lose the gas once you dismantle the cooper pipe.
@thebman8787
@thebman8787 2 жыл бұрын
Thank you!
@cramemichael2023
@cramemichael2023 3 жыл бұрын
How did you remove the refrigerant. Where it go.
@chipchannel174
@chipchannel174 3 жыл бұрын
Pump down process is to keep the gas into the compressor.
@imStrato
@imStrato 2 жыл бұрын
@@chipchannel174 Not in the compressor itself, it does not have capacity to hold average amount of refrigerant. Most of the refrigerant is stored in the condenser tubes.
@barrygaynor1025
@barrygaynor1025 Жыл бұрын
Thank you.
@chipchannel174
@chipchannel174 Жыл бұрын
You're welcome!
@snowythehusky5912
@snowythehusky5912 2 жыл бұрын
Bro kalau dalam kondisi ada freon seperti ini, apakah aman dibawa pakai mobil untuk dipindahkan? Thank you
@chipchannel174
@chipchannel174 2 жыл бұрын
Tiada masalah..tutup semua valve rapat elok. Sama seperti kita beli AC baru, dlm dia sudah ada freon dah. Untuk pemasangan semula kemungkinan hanya perlu tambah freon sedikit sahaja. Jimat wang.
@skkadir655
@skkadir655 3 жыл бұрын
Thanks brother
@chipchannel174
@chipchannel174 3 жыл бұрын
Welcome
@chipchannel174
@chipchannel174 3 жыл бұрын
Please share this video if you think this helpful. Im not an expert but I just share based on my experience and for my reference as well.
@elvischew1758
@elvischew1758 2 жыл бұрын
Can u still save the freon
@chipchannel174
@chipchannel174 2 жыл бұрын
Yes. It will keep inside your compressor at lease 80%.
@joselitoulanday3803
@joselitoulanday3803 2 жыл бұрын
@@chipchannel174 after dismantling and if i transfer it to another room can i just do or reverse ur step ? Without vacuum machine?
@chipchannel174
@chipchannel174 2 жыл бұрын
@@joselitoulanday3803 better have vacuum pump and also the gauge to optimise the system. Probably you need to top up the gas as well. To reconnect the cooper pipe you need to check either have leakage or not. Else all the gas will be gone and might damage your compressor as well. Please consult an expert near by you before you proceed.
@TheWuzyy
@TheWuzyy 6 ай бұрын
For god sake, please use the long end of the hex wrench!
@stvn2918
@stvn2918 3 жыл бұрын
Very useful 👍
@chipchannel174
@chipchannel174 3 жыл бұрын
Thanks a lot
@zaidhamid7269
@zaidhamid7269 3 жыл бұрын
Love the black ops 2 intro
@keerthirajendran5952
@keerthirajendran5952 3 жыл бұрын
What is the size of hexagon wrench??
@chipchannel174
@chipchannel174 3 жыл бұрын
Sorry about that. I forgot the size for the Allen keys. I have a set of combinations size so I just try which one is fix. If I have the opportunity to confirm on this I will share in my next videos.
@vishnukannan236
@vishnukannan236 4 жыл бұрын
I closed liquid line first and after 4 Minute i closed gas stop valve any problem pls tell
@chipchannel174
@chipchannel174 4 жыл бұрын
Depend on AC HP..if 1 HP with less than 10 feet cooper pipe should be ok.
@arseniong7940
@arseniong7940 3 жыл бұрын
When re installing, then is it same procedure? Ty
@chipchannel174
@chipchannel174 3 жыл бұрын
Can you translate in english please. Tq.
@chipchannel174
@chipchannel174 3 жыл бұрын
For installation you need to have vacuum and guage before release the gas.
@addiszemen1637
@addiszemen1637 3 жыл бұрын
thank you!
@chipchannel174
@chipchannel174 3 жыл бұрын
Welcome
@avetsuper6272
@avetsuper6272 2 жыл бұрын
what about freon from pies ,its gone to air ?
@chipchannel174
@chipchannel174 2 жыл бұрын
That’s the reason of pump down process before dismantle the unit.
@arcticathena9487
@arcticathena9487 Ай бұрын
if air-condition is not under power how we unistall it, due we cannot open air condition to work so to close the pumps
@chipchannel174
@chipchannel174 Ай бұрын
@@arcticathena9487 pump down process need to run the units. If no power, better refer to technical team for help.
@pajayalath9967
@pajayalath9967 3 жыл бұрын
Thank good video .
@unrulian
@unrulian 4 жыл бұрын
my problem is board is broken and I can't turn it on but need to remove unit. can you do this without turning unit on?
@chipchannel174
@chipchannel174 4 жыл бұрын
Just close the valve and slowly disconnect the cooper pipe. Please be careful cause it high pressure.
@matttzzz2
@matttzzz2 4 жыл бұрын
@@chipchannel174 STOP. NO. You're NOT allowed to just release the gas into the atmosphere. Stop repeating this nonsense to everyone! You have to capture the gas using a recovery unit into an emptg gas bottle that will be dosposed of.
@fartsmccracken1445
@fartsmccracken1445 3 жыл бұрын
@@matttzzz2 Screw the environment. I got work to do. Biden’s gonna kill us all anyway.
@GregoryJHill-ub6ow
@GregoryJHill-ub6ow 3 жыл бұрын
My copper lines were soldered directly to AC unit. Can I cut these lines?
@chipchannel174
@chipchannel174 3 жыл бұрын
You can cut after pump down and turn off the main supply.
@shahriljaszle4606
@shahriljaszle4606 4 жыл бұрын
Tahniah Bro
@chipchannel174
@chipchannel174 4 жыл бұрын
Untuk rujukan diri sendiri di masa hadapan sama tuan. :)
@ronmaxwell6972
@ronmaxwell6972 3 жыл бұрын
turn the crescent wrench over Dude.
@mike82y
@mike82y 2 жыл бұрын
What will happened if u just let u leak out?
@chipchannel174
@chipchannel174 2 жыл бұрын
First, you will contribute to air pollution. Second, you need to refill the gas during installation and cost you more $.
@mohanv9483
@mohanv9483 3 жыл бұрын
One doubt liquid line close time slow proses gas pipe line close slow proses but compress is running pressor high blastses chances. There
@chipchannel174
@chipchannel174 3 жыл бұрын
Basically, I just follow the service guide and show the step by step pump down process.
@sucider5406
@sucider5406 2 жыл бұрын
Very useful 🙏
@chipchannel174
@chipchannel174 2 жыл бұрын
Thank you..
@akadbakadbombayaboo
@akadbakadbombayaboo 3 жыл бұрын
How do you know which valve is gas valve and which is liquid valve. The size of both the valve on brivis honbr50 outside unit is nearly same Thanks
@chipchannel174
@chipchannel174 3 жыл бұрын
Please refer product manual for confirmation.
@chipchannel174
@chipchannel174 3 жыл бұрын
The cooper pipe size should be different.
@azaanusman8039
@azaanusman8039 4 жыл бұрын
Brother mene ghalti se AC on kiye bagair outdoor seprate krdiya is se jo condenser me gas thi wo waist ho gai brother kitne percent gas meri zaya ho gai ap bta sakte hai
@chipchannel174
@chipchannel174 4 жыл бұрын
Im sorry brother...Im not understand your question. Can you translate it to english?
@chipchannel174
@chipchannel174 3 жыл бұрын
@@RideAdventureMoto do not release the gas to the atmosphere as this will impact the environment...need to have gauge and transfer to empty gas bottle or please consult your local competent person for help.
@senthilkumars9288
@senthilkumars9288 3 жыл бұрын
Super
@normanlatu3498
@normanlatu3498 3 жыл бұрын
What about if there gas still in the lines?
@chipchannel174
@chipchannel174 3 жыл бұрын
Pump down process actually to pull all the gas inside the pipe and keep inside the the compressor. So, please complete the process to avoid release the gas to environment which will cause the pollution. Second things is you no need to top up the gas or just minimal when you reinstall the AC to others location and will save your money as well.
@xauyala
@xauyala 4 ай бұрын
Thanks
@chipchannel174
@chipchannel174 4 ай бұрын
@@xauyala welcome
@sonchan3621
@sonchan3621 Жыл бұрын
how to put it back again?
@ashishsankrit1290
@ashishsankrit1290 4 жыл бұрын
After removing the outdoor unit how to remove the pipe safely from indoor unit is their any connector or any joint ??
@chipchannel174
@chipchannel174 4 жыл бұрын
Yes. There is another joint at indoor unit need to remove. Disconnect the incoming power cable as well. After that you can lift up the indoor unit out from the bracket. Then remove the bracket at wall. That it.
@maxgrind438
@maxgrind438 2 жыл бұрын
What if the compressor is damaged.?
@chipchannel174
@chipchannel174 2 жыл бұрын
Basically, you need gauge and release the gas into empty container in order to dismantle the outdoor unit. Do not release the gas direct to environment. This video just show the pump down process before dismantle the outdoor units that still function or working well.
@Swenser
@Swenser 4 жыл бұрын
I closed liquid line and after a few minutes decided to not pump down but re open liquid line. I expected the system to revert to normal operation, but the compressor cuts of after a few seconds, like there is a problem sensed. I left over 24 hrs to rebalance gas but the compressor still stops after a few seconds and cycles about every minute. What could be the problem after this closing of liquid valve temporarily for a few minutes? Why does the compressor stay on. It was fine before attempted cut short pump down.
@chipchannel174
@chipchannel174 4 жыл бұрын
How long you turn on the AC after re open the valve? What is the temp setting at your AC controller? You can try to set at min temp and run the AC. Usually the compressor will turn off if the indoor sensor detect the temperature tally with the controller setting. Hope this help.
@Swenser
@Swenser 4 жыл бұрын
@@chipchannel174 temp was set at minimum. After 24 hrs rest just in case of pressure imbalance or frosting I tried ac on for 15 minutes but always cycled on for a few seconds off about 1 min. Pumping compressor down for a few minutes maybe damaged compressor in my case??
@chipchannel174
@chipchannel174 4 жыл бұрын
@@Swenser please check your liquid line valve again. Could be the valve not fully open or maybe stuck. How’s the room temperature? It’s cool?
@Swenser
@Swenser 4 жыл бұрын
@@chipchannel174 warm day in melbourne. gas definitely at schraeder valve. A quick depression of valve confirmed that. No gauge to check pressures. Evap not showing any signs of icing at all.
@chipchannel174
@chipchannel174 4 жыл бұрын
@@Swenser Im facing 1 issue before this outdoor unit not running or intermittence due to not enough gas..need to top up the gas according to outdoor specs then the AC back to normal. You need have gauge to confirm on this.
@carlyncorley9187
@carlyncorley9187 2 жыл бұрын
bang apa mksud pump down sblm tutup valve tu and knpa nak psg ac?
@chipchannel174
@chipchannel174 2 жыл бұрын
Nak sedut dan simpan gas masuk ke dlm compressor sebelum buka paip..kena turn on untuk bg compressor jalan.
@jaewalker1527
@jaewalker1527 4 жыл бұрын
Can i do it by turning off the the ac, I’m worried of being electricuted
@chipchannel174
@chipchannel174 4 жыл бұрын
To pump down the gas and keep inside the compressor, you need to follow this steps with running condition. Once done then you can switch off the supply and dismantle the cooper pipe.
@jaewalker1527
@jaewalker1527 4 жыл бұрын
@@chipchannel174 thanks i did the same procedure...
@ddaanniijjeell
@ddaanniijjeell 3 жыл бұрын
Tnx for this 👍💪
@flattblackjakus
@flattblackjakus 3 жыл бұрын
I have a 7000btu unit with only a 10ft pair of lines hooked up to my school bus conversion. What’s the length of time I should wait till closing the second valve?
@chipchannel174
@chipchannel174 3 жыл бұрын
Thanks for your comment. The proper way is using the gauge or you can refer to installation guide ( pump down ) according to your AC model and brand. Some manual said the duration is 5 minutes or more referring to your lines length. You can feel the hot air blowing turn to normal temperature and you can close the valve. For my case line length also about 10ft. Anyway, Im not an expert but I’m sharing this video based on my experiences.
@johnpaulcalubay6120
@johnpaulcalubay6120 3 жыл бұрын
Hello is this need to set to highcool to close all the valve to pump down?
@chipchannel174
@chipchannel174 3 жыл бұрын
As long as outdoor unit running.
@garyfiel2514
@garyfiel2514 3 жыл бұрын
Boss pwede napo ba hinde na gamitan ng guage please thanks
@chipchannel174
@chipchannel174 3 жыл бұрын
Sorry..can you translate to english please..
@kevin13sepidar
@kevin13sepidar 2 жыл бұрын
Do you do this when the unit is off ?
@chipchannel174
@chipchannel174 2 жыл бұрын
Pump down process need to run the unit. Once complete, turn off the supply and remove the power cable.
@hlalthanpuia1494
@hlalthanpuia1494 Жыл бұрын
​@@chipchannel174 How many minutes to turn on the unit before tightening the valves?
@chipchannel174
@chipchannel174 Жыл бұрын
Depend on the AC model n saiz..1hp around 10-15 minutes. You may refer to AC manual for correct timing.
@chipchannel174
@chipchannel174 Жыл бұрын
@@hlalthanpuia1494 you can follow the instruction as per video
@jesterrio6251
@jesterrio6251 3 жыл бұрын
inverter or non inverter the same procedure?
@chipchannel174
@chipchannel174 3 жыл бұрын
Procedure should be the same. The different between this AC type just to control the power. For the duration you may refer to service manual or expert on your area. I just show the step by step process only. Hope this help.
@franciskimocop6018
@franciskimocop6018 3 жыл бұрын
What if there is no power ? How can i remove the outdoor unit ?
@chipchannel174
@chipchannel174 3 жыл бұрын
You must have pressure gauge and empty gas bottle to transfer the gas before dismantle the cooper pipe. Do not release the gas to the atmosphere. Please consult your local competent person for help if required.
@atuldaware3679
@atuldaware3679 4 жыл бұрын
Thank u..
@chipchannel174
@chipchannel174 4 жыл бұрын
atul daware welcome
@viktorponkratov3213
@viktorponkratov3213 3 жыл бұрын
👍👍👍
@hubertdsouza5610
@hubertdsouza5610 3 жыл бұрын
When have to make power (AC) off
@chipchannel174
@chipchannel174 3 жыл бұрын
After you complete tighten the gas valve.
@hubertdsouza5610
@hubertdsouza5610 3 жыл бұрын
@@chipchannel174 Thank you
@chipchannel174
@chipchannel174 3 жыл бұрын
@@hubertdsouza5610 you are welcome..please share if you like this video ...
Refrigerant Pump Down: Step-by-Step Guide
6:47
Taddy Digest
Рет қаралды 51 М.
Don’t Choose The Wrong Box 😱
00:41
Topper Guild
Рет қаралды 18 МЛН
Thank you Santa
00:13
Nadir Show
Рет қаралды 48 МЛН
How Many Balloons To Make A Store Fly?
00:22
MrBeast
Рет қаралды 163 МЛН
90% of Toilets Are Installed Wrong (Here’s the Right Way)
16:04
Home RenoVision DIY
Рет қаралды 1,8 МЛН
How to backup and uninstall a Mini Split to move it and Life Update.
10:48
Steps to Vacuum and Charge Refrigerant on a Mini Split Unit!
15:08
AC Service Tech LLC
Рет қаралды 1,3 МЛН
How to Clean Your Mini Split AC Condenser - Make it Cold Again
7:06
Silver Cymbal
Рет қаралды 802 М.
How does the air conditioner work?
7:26
Mscope
Рет қаралды 3 МЛН
BEST AC Drain Line Cleaning Tool | 92 % DON'T Know This
5:51
Deanin' It Yourself
Рет қаралды 871 М.
Paano Magkalas ng Split Type Aircon?
8:08
MaThalent
Рет қаралды 26 М.
Don’t Choose The Wrong Box 😱
00:41
Topper Guild
Рет қаралды 18 МЛН