How to factory setting delta vfd / delta vfd ko factory reset kese kare / delta vfd - B

  Рет қаралды 19,167

TECHNICAL HABSHI

TECHNICAL HABSHI

Күн бұрын

Пікірлер: 14
@fredericfagot9231
@fredericfagot9231 6 ай бұрын
hello, thank you for all your help could you please help me? I try to have the motor starts as soon as the power is turned on for a VFD-B Regards Frederic
@hukamsingh3191
@hukamsingh3191 5 жыл бұрын
Apfc relay 3ct ya 1ct me konshi better h stone cutter load me konsi shi rhegi power factor control ki liye
@mohsinhabshi
@mohsinhabshi 5 жыл бұрын
3ct hogi to pf balance me rhega....
@chaudharykaif
@chaudharykaif 3 жыл бұрын
Sir ye derive me forward run jog reverse stop sab on hojaraha hai to kya problam hai
@mahmoodbhaijaan4062
@mahmoodbhaijaan4062 3 жыл бұрын
sir drlta vfd b series ka parameter change nhi ho rha he display par err show ho rha he please help me
@akshayror7061
@akshayror7061 Жыл бұрын
Sir Drive me Display show --88888 show Ho rha h ..Fault Reason.
@Mikeecanales1925
@Mikeecanales1925 3 жыл бұрын
How about "HO" alarm? How can we reset and address the alarm?Tnx
@mohsinhabshi
@mohsinhabshi 3 жыл бұрын
OH Overheating Heat sink temperature too high 1. Ensure that the ambient temperature falls within the specified temperature range. 2. Make sure that the ventilation holes are not obstructed. 3. Remove any foreign objects from the heatsinks and check for possible dirty heat sink fins. 4. Check the fan and clean it. 5. Provide enough spacing for adequate
@innovation8989
@innovation8989 4 жыл бұрын
Hi
@DGMarbleguy
@DGMarbleguy 2 жыл бұрын
I'm struggling with an "EF" fault code on a newly installed VFD-B. If I disconnect the EF Wire on the board and hit external momentary start start switch I get an "OC" fault code. Any help would be greatly appreciated.
@mohsinhabshi
@mohsinhabshi 2 жыл бұрын
External Fault 1. Input EF (N.O.) on external terminal is closed to GND. Output U, V, W will be turned off. 2. Give RESET command after fault has been cleared. Oc 1. Check if motor power corresponds with the AC motor drive output power. 2. Check the wiring connections to U, V, W for possible short circuits. 3. Check the wiring connections between the AC motor drive and motor for possible short circuits, also to ground. 4. Check for loose contacts between AC motor drive and motor. 5. Increase the Acceleration Time. 6. Check for possible excessive loading conditions at the motor. 7. If there are still any abnormal conditions when operating the AC motor drive after a shortcircuit is removed and the other points above are checked, it should be sent back to manufacturer.
@innovation8989
@innovation8989 4 жыл бұрын
Hi
VFD-B(VFD022B43B@AF95)settings
11:31
PLC Nepal volgs
Рет қаралды 2,4 М.
UFC 310 : Рахмонов VS Мачадо Гэрри
05:00
Setanta Sports UFC
Рет қаралды 1,2 МЛН
黑天使只对C罗有感觉#short #angel #clown
00:39
Super Beauty team
Рет қаралды 36 МЛН
Cheerleader Transformation That Left Everyone Speechless! #shorts
00:27
Fabiosa Best Lifehacks
Рет қаралды 16 МЛН
delta drive vfd075f43b parameters not sett problem fix
5:00
VFD REPAIRING LAB
Рет қаралды 1,7 М.
how to Run Delta VFD-B ,what is Sink source Mode and how to control the speed.
14:02
VFD+Electrical Electronics Repairing
Рет қаралды 5 М.
F series delta drive setting
3:07
Innsale Teknik
Рет қаралды 14 М.
Delta VFD- B  Inverter Parameter  Setting system
3:58
S.m. Electrical work
Рет қаралды 6 М.
UFC 310 : Рахмонов VS Мачадо Гэрри
05:00
Setanta Sports UFC
Рет қаралды 1,2 МЛН