How to fix CH41 Error Code in Split Air-conditioned.

  Рет қаралды 22,994

Quincy Caitlyn TV

Quincy Caitlyn TV

Күн бұрын

Пікірлер: 21
@justinf6506
@justinf6506 Жыл бұрын
So the sensor is attached to the indoor unit ?
@allinonetelugu467
@allinonetelugu467 3 жыл бұрын
Tq bro..
@quincycaitlyntv3166
@quincycaitlyntv3166 3 жыл бұрын
Thanks for watching my video. I hope its help you. Don't forgot to like, share and Plz subscribe.☺️
@cheikhtidianeniang9870
@cheikhtidianeniang9870 2 жыл бұрын
Merci beaucoup
@edxgomez3051
@edxgomez3051 3 жыл бұрын
OBRIGADO AMIGO
@marcelinoerese2938
@marcelinoerese2938 2 жыл бұрын
sir tanong ko lng po sa window type lg dual inverter nagplit n po ako ng discharge pipe sensor pero ch 41 p rin po posible po b n sa main board n po b ang problema
@quincycaitlyntv3166
@quincycaitlyntv3166 2 жыл бұрын
Hi sir, 1. Pede nyo po I check ung connection ng terminal ng D. Sensor at terminal ng control box if ok po Ang connection. 2. Ung terminal from cbox pede nyo poh I check ung pin connection if ayos po b ung soldering. Salamat po.
@shanehasan2674
@shanehasan2674 2 жыл бұрын
Discharge sensor what will be the value I mean D sensor
@quincycaitlyntv3166
@quincycaitlyntv3166 2 жыл бұрын
Hello Shane Hasan, Using tester 5kohm at 25 room temp. Hope this will help you.
@shanehasan2674
@shanehasan2674 2 жыл бұрын
Can you share me your whatapp number
@joseporras7067
@joseporras7067 3 жыл бұрын
De cuantos k es el sensor
@kingsleyobinna9332
@kingsleyobinna9332 2 жыл бұрын
Nice one
@mengfu8834
@mengfu8834 2 жыл бұрын
After changing the sensor ch41 error gone split unit working properly
@quincycaitlyntv3166
@quincycaitlyntv3166 2 жыл бұрын
Good to hear that. That's for watching the video. Like and subscribe ☺️
@justinf6506
@justinf6506 Жыл бұрын
Is the sensor in the indoor unit or outdoor unit? Thanks in advance!
@srisrinivasacablenetwork-pali
@srisrinivasacablenetwork-pali 2 жыл бұрын
Where can i buy new sensor
@quincycaitlyntv3166
@quincycaitlyntv3166 2 жыл бұрын
Hi. What is the brand of you AC.? And where is your country?
@tunedprashant3732
@tunedprashant3732 2 жыл бұрын
@@quincycaitlyntv3166 hello please reply mine is LG brand and I am from India Please let me know where to buy.
@quincycaitlyntv3166
@quincycaitlyntv3166 2 жыл бұрын
Hello. From India please contact service center. You can buy there sensor. LG Service Centre-Agra. I'm not sure in contact no. I just saw in Google. But you can try. +918433329248. Thanks
@darbarshaik1662
@darbarshaik1662 3 жыл бұрын
Ch 45 error code
@quincycaitlyntv3166
@quincycaitlyntv3166 3 жыл бұрын
Hello Shaik. For CH45 error code ''outdoor unit temp sensor open/short". Error reason: sensor or PCB defect. Poor housing connection to PCB or sensor terminal pin defect. How to check? Check the sensor housing is properly insert to PCB housing. Also check the resistance value of pipe sensor using tester. 5kohm at 25 room temp. Hope this will help you.
COMO SOLUCIONAR E RESOLVER - CÓDIGO DE ERRO CH 41 AR CONDICIONADO LG INVERTER
11:29
How to fix CH26 Error Code in Split Air-conditioned.
3:45
Quincy Caitlyn TV
Рет қаралды 10 М.
99.9% IMPOSSIBLE
00:24
STORROR
Рет қаралды 31 МЛН
LG error ch41
12:08
AG&AC HATING & COOLING VENTILATION 🥶🥵
Рет қаралды 11 М.
How to fix CH44 Error Code in Split Air-conditioned.
3:11
Quincy Caitlyn TV
Рет қаралды 4,8 М.
How to fix ac water leakage problem in tamil
5:47
Velaikaran
Рет қаралды 172 М.
Finally! A Tumbler That Destroys the Stanley!
19:13
Project Farm
Рет қаралды 529 М.
COMO TESTAR MOTOR VENTILADOR CONDESADORA SPLIT CONVENCIONAL
6:59
REFRIGERAÇÃO TROPICAL
Рет қаралды 21 М.
CH 05 LG saiba como resolver esse código de erro Lg    #rac #climalg #esquadrao2022 #lg
11:54
CH 05 Error LG Dual Inverter Air-condition #ac  #error  #codes
5:31
DIY & Fix it
Рет қаралды 55 М.
Solución error ch41 Aire LG inverter V...
5:27
Totti Mejia A/A
Рет қаралды 10 М.