I bought one way back, those days the PUMP & bypass valve was all, you had to go purchase hoses, NEW ones NOW INCLUDE THOSE HOSES, THEN GRUNDFOSS SENT ME SOME PROMO & another bypass valve , so upstairs , the lines & bypass valve ore under the sink,so I get hot water quickly @ sink,bathtub& a shower , the other is under the sink on 1st floor & KITCHEN SINK. It’s set off 2 am,on 6 am, works just fine , 🇳🇴🇳🇴🇺🇸🇺🇸
@brianbaker52926 жыл бұрын
Recommend revised 2nd video on how to install complete package meaning by pass and more
@chefbambu9382 Жыл бұрын
How can you tell is the bypass valve is working? The pump sounds like it's running but water not circulating???? Thanks for your help.
@pjmazar45334 жыл бұрын
A pump is not necessary if you can access the pipe lines to the furthest fixture. Installing a t-fitting in the hot line and returning it to the drain pipe of the tank with a check valve will give you nearly instant hot water at all the fixtures in the system. No pump needed because gravity does all the work. This works great in single story homes but will also work in a 2 story by plumbing to the furthest point accessible. It is not perfect, but it does help.
@jeanies8495 Жыл бұрын
I deactivated the pump and you are right. I want to take the recirculating valve out. Is that easy to do myself?
@johnnyllooddte341511 ай бұрын
gravity???? that makes no sense either and sounds like it violates code
@chetmyers704110 ай бұрын
@@johnnyllooddte3415 Cold water sinks.
@TruongLe-eo8kh9 ай бұрын
Do you have a flow diagram ?
@pjmazar45338 ай бұрын
It's actually convection, but some didn't understand that.
@charleslepere89247 күн бұрын
What happens to the pump id the bypass valves are hot and don’t allow for recirculation? Does that blow out the pump?
@richardfuess45213 жыл бұрын
can u use this on a tankless waterheater too
@allover56224 жыл бұрын
If I understand the mechanics correctly, when the water recirculates back through the cold line, we are then drinking water that has been run through the hot water tank? I have always understood that due the use of decaying aluminum anode rods, water from the hot water tank should not be used for drinking or cooking. Is this safe?
@digi32183 жыл бұрын
Good question. I am guessing a water filter on the fridge may take care of this.
@arealmaintenanceandrepairl11033 жыл бұрын
Say timer is set for 630-640 I’m not using the faucet what happens to the pressure when the line water reaches temp build pressure bust a line or what happens that seems better to manually turn pump on prier to use once u open the hot tap turn pump off but how does this way work with the pump on a timer
@PD-yd3fr2 жыл бұрын
Was thinking that myself, why not just have the valve dump water into the drain?
@doughill54872 жыл бұрын
@@PD-yd3fr Because dumping in it the drain is exactly what you're trying to avoid. The idea of this is to save time AND water.
@Hawka-Loogy Жыл бұрын
Can you hear the water running through the pipes like when a faucet is in use? That would suck
@rss6082 жыл бұрын
had one of these units for 16 years. Pump works correctly but the valve at the end of the line is another matter. I'm on a well so have high alkaline water. Once per year I must pull the valve and replace it. It gets fouled with alkaline. I take the removed unit, soak it in white vinegar for about 24 hours and force compressed air through it to make sure it is open. I store the unit for the next year. I have a water softener, 5 micro water filter and use a RO filter for drinking water.
@philindeblanc2 жыл бұрын
I have not had mine installed long, and already I think the thermo valve is not working. I thought it might have an adjustable temp to set, but nope. Its a dummy unit with internal function. So I have to take this thing out and descale it? Geez...Is this gonna happen easily all the time? I too use a RO for drinking, but not for the rest of the water line. I do want it for shower so I can remove the fluoride in that as well. Most important thing to remove. But, this valve is now the issue...At least I think. Any way to test it?
@stephen22209 ай бұрын
Can the recirculating pump be used with the heat trap or does it need to be removed before installation?
@5thGenNativeTexan4 жыл бұрын
The one thing I continue to not quite understand is how hot water will be immediately available at all my faucets/showers, etc by putting the one check valve on the sink at the furthermost run from the water heater. It would seem that there would still be some branches/legs of pipe to the other faucets/showers that still would have some cool water in them, and that really only the sink with the check valve is the "immediately available" sink. I have a two-story house, 4 bathrooms, kitchen, etc, spread out over 4600 sq ft. Will I really get hot water immediately at every faucet/shower in the house?
@tomkrupica3 жыл бұрын
If it’s in a loop now then it would. It would be very quick to the other sinks even if they are not in a loop
@5thGenNativeTexan3 жыл бұрын
@@tomkrupica No loop. Just a typical install as in the vast majority of homes. I do get it that I would get hot water faster out on the branches/legs, as the main line would have hot water. But there would still be some lag on the branches.
@merlinious013 ай бұрын
@5thGenNativeTexan Plumber here, you would be correct there will be lag, specifically the amount of water contained in the individual branch from the trunk line. This system keeps the trunk line warm, but not all the branches. You can install multiple of these sensors though. If you (properly) installed one at every fixture you could have essentially instant everywhere.
@jeremiahjohnson7316 жыл бұрын
Do you have a video on the bypass valve on how to hook that up
@ryancolebourn3060 Жыл бұрын
When the valve closes, isn't the pump then pumping against a closed system? Is that not bad for the pump?
@mrjsutphenEDU5 ай бұрын
Before the Valve closes, it is easier to pump horizontally back into the cold system rather than push water up into a faucet. When the valve closes, the pump still has a path out of the faucet and the hot water is pushed out.
@RodWood3 ай бұрын
Can you use this on a tankless hot water heater?
@MrTrevorg18 Жыл бұрын
Will this system work if i only had the sensor valve at furthest fixture, without a recirc pump installed?.
@davidhutchinson8808 Жыл бұрын
Could you make it with a flow switch instead of a timer? We are retired and don't have set times that we need hot water in the kitchen.
@bobg84442 жыл бұрын
Can this be used on a tankless water heater?
@utube4greenfuture2 жыл бұрын
The pumps with higher flow rate work but, not with those black plastic bypass valves. Avoid using those comfort valves in high calcium area's or you'll be replacing them every two years. You'll know they've failed when you get scolded from the valve locking in open position.
@gadgetman694 Жыл бұрын
I have a couple of questions: #1 So the pump runs sending the hot water to the sensor valve under the sink. When the sensor determines the water coming to it is hot, it shuts off dumping the water down the cold water line. When that sensor valve activates, does the back pressure in the pump line cause the pump to shut off - or does the pump just continue to run until the timer shuts it off? #2 with the pump off and not running via the timer, will tank water flow through the pump with the pump not running?
@happycamper5900 Жыл бұрын
I have this exact pump in my 5 yr old house. It works great. I set the timer to run in the morning and evening. When not running, everything works as usual. I had to replace the pump and bypass valve after 4 yrs. The pump runs when the timer says it is supposed to run. This is a fractional pump so it is a tiny amount of water being recirculated back into the hot water heater. Not sure why so many negative comments here?? This guy is spot on everything he is saying. I have hot water literally in seconds during periods when the timer is set. Good video.
@divisorplot10 ай бұрын
thx live in a high-rise condo. Glad to have the plumber explain the problem with the recycle valve. Management abusing owners saying they need to change the shower controller. Did cross reference also with mainline cold water shut off same hot water problem 45 seconds to the bathtub, 2 minutes to sink. At least i know and others know of the issue. Can't explain why managers of large condos would not k-now or the plumbers themselves. Finally got to google the recycling valve. thanks. What can owners do to [prevent abuse and scams? They still not fixing the issue at their end, yet threaten us with changing bathroom controls. for Failure to maintain. Should be articulated through media the abuse and scams on condo owners, even the additional charges for large apartment rentals if and then.
@realtransport65574 жыл бұрын
You push down the cooled off water in cold line .that means you will have warm water in cold line .
@GravityRoller3 жыл бұрын
So then, warm drinking water, ummmh. Like robbing Peter to pay Paul.
@johnhegarty41012 жыл бұрын
Can I have 2 bi pass valves on 1 recirculating pump
@curtisjohnson488610 ай бұрын
my water is low through out my house my house is 2001 will this issue?
@avidskier733 жыл бұрын
Liked the video, thank you. Do you recommend a bypass valve at each hot water location? i.e. Kitchen, master bath, upstairs bath, and guest bath? The guest bath is nearest to HW Heater. Next would be the master bath and in close second the kitchen and then upstairs bath, is the furthest place hot water needs to travel. So, in theory, if I install the bypass valve in the upstairs bath sink, my hot water should arrive much quicker at each location?
@brasha783 жыл бұрын
If on the same run or loop yes. If you have separate branches of hot and cold than you would need one at the end of each branch / leg. I’m going to see if I can track down plans for our house, but I’m also certain I can go into the mechanical room and find the direction of the water and determine my number of runs. Hope that helps your question.
@Al_Z.Heimer11 ай бұрын
Sound like the materials aren't going to last but a few years. How often must you replace with hard water? soft water?
@fstellab12 жыл бұрын
with this work with a mixing (anti scold) by pass value?
@vicO13232 жыл бұрын
This is great but here in the summer in Arizona the cold water turns warm. I turn my water heater to vacation mode at 60 degrees and don't need 110 degree hot water. The dishwasher already heats for cleaning and a cool shower is more comfortable in the summer. I'm originally from Washington state so I really miss having cold water in the summer.
@jeanies8495 Жыл бұрын
I’ve been thinking about doing that, but I’ve been reading it can create bacteria in your hot water tank if it’s below 120°F. Any opinions on this
@jakethesnake95288 ай бұрын
Great video with even better explanation of how the bypass works.
@josesosa16283 жыл бұрын
Can i use this pump with pex pipe line?
@jeanies8495 Жыл бұрын
How do I remove that thing? I don’t want to use the recirculating pump anymore so I unplugged it but I am still getting hot water instantly at the sink that has bypass valve under it. I don’t want the hot water recirculating at all anymore. Can I just turn off the water that sink? It’s still coming out.
@valley21187 жыл бұрын
Question? Our 1931 home has 5 bathrooms!! Really as it was a boarding house and we have this system which is awesome 😉 BUT we still have a bathroom that I need hot water quicker so can I install another comfort valve or move the original valve until I find that sweet spot of hot water? Thanks and you're video clip was spot on compared to the 3 other videos that I watched prior.
@brasha783 жыл бұрын
This isn’t fact but I’m willing to guess that you’d need to install the bypass valve with the gel tab that he talked about that goes at the sink in the farthest location. You would already have flow to the hot water on whatever direction it ran from the tank.
@KazzArie5 жыл бұрын
What if you use the bypass valve without a pump, should cut back on water waste, right? I don’t mind waiting a bit but I’m metered
@scottlittlewood45273 жыл бұрын
That's the point of the bypass and pump. It recirculates, it does not pour away.
@tinman19552 жыл бұрын
I don't get it. What are you bypassing from where and to where and how is it faster??
@johnfischer28183 жыл бұрын
When you turn on the cold water faucet after the heating is done will the cold water now be warm/hot?
@peacefuldavid13 жыл бұрын
It depends on how cold the water in the hot water pipe is. If you haven't run the water all night long, then the entire hot water line from the water heater is cold. The check value will shut the water off once hot water reaches it. So depending on how warm the hot water line is, that is how warm your cold side will be.
@slapmesillytom2 жыл бұрын
can this be used on a tankless heater? my kitchen takes 3 min to get warm . waiting water. or do I need a circulating line on the kitchen going back to the tank? or just this pump will do it? thanks
@DudyOne10 ай бұрын
Will not work with tankless.
@hurley1229644 жыл бұрын
My water heater is basically in the center of my house. The hot water line tees off and one branch goes to master bath and then up to another bath. The other line goes to kitchen and another upstairs bath. Do I install a recirc valve in both upstairs bathrooms which are on opposite ends of the house?
@etyrnal3 жыл бұрын
So how long does it take to get Coldwater now?
@bobbygomez71412 жыл бұрын
Does this work with a water softener already installed?
@sikupnfed2 жыл бұрын
Seems my AO Smith water heater has a built in heat trap so this system won't work for me.
@brianveltri3107 Жыл бұрын
Is this part all I need????
@oceanmariner6 жыл бұрын
So if the cold pipe is full of hot, where do you get cold water? I use a 3 line system.
@gfriedman996 жыл бұрын
Ocean Mariner wait for it to cool off
@hyster25684 жыл бұрын
@Bob J so it pushes the cold water back to the water heater?
@MikeTrieu2 жыл бұрын
@@hyster2568 Yes. Your water heater will temporarily also get slightly colder. This isn't really an issue for tankless, obviously.
@pablogaviria92659 ай бұрын
Use a DEDICATED Hot Water Return Line.
@oceanmariner9 ай бұрын
@@pablogaviria9265 That what a 3 line system is. Hot, cold and hot return.
@ItiscalledaMANDATE Жыл бұрын
Can this work with a Rinnai R75i on demand propane HW heater? Is there a different arrangement? The original HW design of my house is root and branch but the large addition we built are all home runs with Pex. If there is a system for on demand propane HW heaters I can see it being a plus for the root and branch system in my original house. I see this video was posted 11 years ago.
@arealmaintenanceandrepairl11033 жыл бұрын
But the pump is still running even if it’s on a timer for 30 mns when that tab closes because the line is hot and no one is using the faucet the pump is till pumping then what happens
@jamesrahn20652 жыл бұрын
Could this be used to create in floor heating? I live in cooler climate, Montana, and also worry about pipes in crawl space freezing
@Rolexenforcer Жыл бұрын
Yes!
@fortunatedad76954 жыл бұрын
What pressure is that pump running at? If I set my pump to have instant hot water say between 7 to 9am, how much higher will my water pressure be when using it while the pump is on? Thanks
@sr.gateau Жыл бұрын
A circulating pump will not change the overall pressure in a system.
@fortunatedad7695 Жыл бұрын
But how wouldn't it if it has to overcome the house pressure to get back to the hwt, until it shuts off.
@bradleywilson4663 жыл бұрын
What are your thoughts on a Chili Pepper device? I have used them for 8 years with no problems. Anyone can install them under the sink in the bathroom or kitchen. Press the button and in 30 seconds you have hot water.
@MD-cd7em3 жыл бұрын
WHAT DEVICE IS THAT?
@kenbowen3245 Жыл бұрын
Recently purchased an 8 yr. old custom home with the recirculation pump installed but no sensor at the other end of the house. I installed the sensor and then we had instant hot water. The previous owner had the pump set in the 'on' position, (but he had no sensor). I didn't change the setting when I installed the sensor. Our house has a propane tank for gas heating. Tank filled right after purchase. Within 6 weeks we had burned through over 200 gallons of propane, which is over $700. Have a gas furnace for heat, but are conservative on heat settings, not on at night at all. Gas water heater, and gas cook top. That's it. Propane Co. tested, had no leaks. They're only guesstimate is 50 gal water heater running 25/7 recirculating caused the excessive propane usage. Sound likely??
@jeanies8495 Жыл бұрын
I unplugged my recirculating plug, I’m in a two-story house with a bridge valve upstairs so I still get hot water even without the pump. But this means my water heater is running all the time and it’s trying to recirculate all the time. I want the bridge valve out but I want to figure out how I do that myself!
@WEYHARRY17 жыл бұрын
Hi What about the chance of legionnaire's disease
@dougmason98486 жыл бұрын
THAT WAS AS AN AC PROBLEM. PAY ATTENTION
@jessehernandez8281 Жыл бұрын
Installed circuit pump and bypassed
@mikrch39353 жыл бұрын
I installed a Watts recirculating pump on my water heater. I installed the Hot Water Recirculating System Sensor Valve Kit under the bathroom sink which I believe it's the furthest from the water heater. When the pump is on, the cold water at that sink is warm not cold. It's the only faucet that does that. I'm not sure what the problem is. Any help is appreciated. Thank you
@doodoodan20122 жыл бұрын
It's because that is where your sensor valve is. The valve opens when the water temperature is under 90° F allowing the hot water to flow throw into your cold water pipe. The valve closes again when the water flowing through it reaches 90° F again. This process happens all the time to keep the warm water at your faucet. When you turn the cold water on you are flushing out the warm water that was pushed into that pipe before the real cold water comes out.
@Modsnake984 жыл бұрын
Can I install this on my boiler that does not have a water heater?
@billkeys561510 ай бұрын
Where is bypass valve installed
@johnnyllooddte341511 ай бұрын
im an engineer and that makes NO SENSE.. are you saying somehow youre hooking the hot and cold water together somewhere downline.. and sending coldhot water back to the tank thru the cold water side
@Followwingyou3 күн бұрын
Exactly. Trust all of us who have these marvelous systems. They are a godsend
@kippywylie2 жыл бұрын
I have a question: Imagine that you live in an older home and you are unable to determine which hot water fixture is the furthest fixture away from the water heater. If I guess wrong will this device still provide benefits?
@donbaker9430 Жыл бұрын
yes, install the manifold at the fixture you want the hot water to quicker
@StevenChristenson Жыл бұрын
Let's say you have a kitchen and two bathrooms. Get two people to help you. On cue you and your helpers turn on full hot water at all three locations at once and the have each shout when they feel hot water. The first to notice is the closest location to the water heater, the last to notice is the farthest location. But the closest and farthest locations may not be on the same path. For example in my remodeled house, the water heater used to be in the middle of the house 12 feet from the kitchen faucet. During remodel, the tanked heater was replaced with a tankless heater in the garage but the hot water now had to flow to what was the middle of the house before it could flow anywhere else. That effectively moved every faucet about 30 feet further away from the heater. It also means that the path from the heater to the kitchen is common between all faucets, but the path from the heater to the master bath is quite different from the path to the guest bathroom. Also, I would also add that I think FasterHotWater.com has a genius solution. They add a "flow monitor" to their system which turns the pump on WHEN it sees water flowing. That means you can e.g. turn on your hot water at any faucet for a second, turn it off and then wait. Meanwhile the pump stays on for 3 minutes to circulate the hot water back to the cold line allowing the heater to push hot water into the line. In this use, you waste very little hot water and do NOT run the risk of continuously running your heater to keep the water in the pipes hot. Note: My plumber had a Watts (Grundfos based) kit that he installed for me, but it didn't work. The reason it didn't work is not clear, but tankless heaters require sufficient flow for them to turn on and apparently either the pump (or the bypass valve) didn't produce enough flow. I just noticed a "genius" idea... which is to install TWO (or more) bypass valves to increase the flow. Gonna try that and if it works, I'll probably add the flow monitor.
@borntwice47243 жыл бұрын
What state are you in?
@goodDeedsLeadTogmailcom8 жыл бұрын
Based on the timer setting, does the pump on the hot water heater discharge line keep running during the chosen time frame of its operation, or it kicks off the moment we open the hot water faucet any where inside home?
@donaldbaker34376 жыл бұрын
They have other products ( booster pumps) for tankless water heaters. Where you push a button in the bathroom to turn the pump on and off. this product is controled by the timer only.
@mrsupert35624 жыл бұрын
so would I need a bypass valve for each fixture that uses hot water ?
@wanaraz4 жыл бұрын
No. If the fixture is between the water heater and the valve the way I read it is you are good to go.
@duubtuub30713 жыл бұрын
...and this because by mixing/pushing the hot water into the cold line (thus keeping it in the supply line, and not wasting it) at the farthest fixture when it gets "too cool" appears to the water heater as "using hot water", lowering the reserve of hot water in the tank and causing it to kick on. The result then is that there is always "hot" hot water at the furthest fixture, and if the hot water line contains hot water all the way to the furthest point, there will be hot water for every fixture closer to the heater too.
@ChrisMorrisW6 жыл бұрын
Is this basically a recirculating pump?
@donaldbaker34376 жыл бұрын
No a booster pump. with a bypass valve.
@larrycurrier2906 жыл бұрын
Donald Baker what's it boosting? it's recirculating
@paulmaxwell88516 жыл бұрын
It's a circ pump. Not a booster pump. It circulates cooled water until that terminal device senses the hot.
@jahnkaplank86265 жыл бұрын
so where do you install that valve?
@dailodai95864 жыл бұрын
under the furthest sink
@b0neme6 жыл бұрын
OK, it will take seconds to get hot water to the furthest faucet. How long does it take to get cold water to that same faucet?
@donaldbaker34376 жыл бұрын
where you install the manifold water will be luke warm. My opinion well work it.
@JR-HeavenonEarth6 жыл бұрын
How do you get more water pressure when your tank is in the basement and you have a 2 story house? Upstairs water pressure is low.
@reubengarcia95545 жыл бұрын
Janeen Reavis booster pump
@jessehernandez8281 Жыл бұрын
I have hot water coming from the cold side after installing the bypass I'll get hot water from the cold side hot water from outside
@PhillipLBoykin7 жыл бұрын
I have this pump and by-pass valve and now I have NO cold water in my Kitchen nor in the farthest bathroom where I wanted the hot water faster. What should I do to get my cold water to be cold and the hot to stay hot?
@b5a5m57 жыл бұрын
Probably need to adjust the pump timing so that it isn't on for as long. OR your bypass valve is bad and isn't closing thus pumping large amounts of hot water into your cold line.
@toddstractorworks7 жыл бұрын
Remove the bypass system and return to the standard system, then install an inexpensive but good quality 120volt under sink water heater to the HOT side of your water, they are about $200, it will just act as a booster and use very little power.
@gogadgo6 жыл бұрын
toddstractorworks hmmm, I've been wanting to install a point of use but the 3 foot power cords are all to short and do not reach the outlet.
@donaldbaker34376 жыл бұрын
where ever you install the bypass valve the water temp at that fixture will be warm. that is the nature of the product, if you have a two story house and the master bath is above the kitchen you could install the bypass valve there. Usually having luke warm water in the bathroom sink is not as bad an issue.
@shirleymartin36059 ай бұрын
Sounds wonderful
@leeritdecha9637 Жыл бұрын
So, where the hell does the bypass valve go???
@Mwfrizzellandsons4 жыл бұрын
But now no cold water?
@Mwfrizzellandsons4 жыл бұрын
You just have to run it until the cold gets there. The opposite problem.
@vtelematicsvtelematics69027 жыл бұрын
My question is actually based on pressure. Houses here are normally installed with an auto pressure pump for the main supply line. The pumps produces a pressure rating of around 10 bar equivalent to 145 psi (Pump on the pent house). Does this mean that the booster or pressure pump on the supply line will contradict the pressure and thus the flow with this recirculation pump? I am not sure how this pump works but in the other video they say as soon as the water temperature at the valve drops to 98 degrees, it will allow water to be recirculated. By this, I believe the Watts small pump works on pressure stutus. When the valve shrinks due to heat change, water is allowed and therefore the pump detects the loss of pressure and starts to function. Does this means if the pressure on the cold supply line is greater or higher to some extent then the Watts pump won't start? In other words, what is the maximum pressure allowed on the cold line or the main supply line for this system to work properly? I am asking this just because we are going to boost the supply line with a 10 bar/145 psi automatic pump for two reasons. 1. It's because we want pressure on all showers below as water supply is free fall from a tank above. 2. A 200 liter central heater is at the same level as on one of the showers. Pressure will be so less at this point. Any help is much appreciated in advance.
@b5a5m57 жыл бұрын
Pumps work on relative pressure. Since there is 145 psi on both sides of the pump (once the lines are pressurized by turning your shutoff valve to the open position) there is a net pressure of 0 between the input and the output. Once the pump is on there is only a slight increase in pressure between the input and output. Think about it this way. Air compressors pump air through them but both input and output sides are pressurized with atmospheric pressure, and thus the atmospheric pressure cancels out and you only have left the pressure that your compressor is set to. There is no pressure difference between hot and cold lines when the pump is off and there is no water running. (By my deduction) The way this system works is there is a pump that has a built in bypass of some sort so when the output pressure of the pump is greater than a certain point the bypass is activated and allows the pump to pump a low resistance route. This is a built in property of some types of "fan" pumps and seeing as the pump is circular I would hazard a guess that they're using this type of pump. So when the temperature sensitive valve at the other end of the pipe opens the pump pumps hot water until the valve closes. When the valve closes the pump "free-wheels" in the bypass so the pressure doesn't get to high. Hope that helps even though your question is 8 months old.
@dougmason98486 жыл бұрын
WHERE ARE YOU AT? NO NORMAL HOMES EVER HAVE A PUMP IN THE ENTIRE USA. UNLESS CUSTOM. MANY USA HOME HAVE A PRESSURE REGULATOR SET ABOUT 75 PSI TO PREVENT SURGES AND WILL BREAK SUPPLY LINE AND FIXTURES . STANDARD FIXTURES ARE RATED AT 100 PSI. BAR IS FOR AIR PRESSURE NOT WATER. ALL OF USA USES FLEX LINES. ITS NOT GHETTO BOZO. WATER HEATERS ARE NOT INSTALLED OUTSIDE EITHER. THERE IS A METAL PHONE BOOTH TO COVER IT. SO MUCH BS ON THIS WEBSITE. THE PLUMBER IS TYPICAL OF THE TRADE TO LEAVE HALF OF IT OUT...... LIVED IN HB FOR 30 YRS --- LOTSA FLAKES.
@philindeblanc2 жыл бұрын
@@b5a5m5 Exactly why you cant have thrust in a vacuum of space.
@pituq1296 жыл бұрын
Make sense. All house should be build like that and Gov should promote or cover the cost for all this installation in order to save water for the whole city.
@eagle18hls5 жыл бұрын
Great Knee Jerk idea that should be given more thought. Can you drink water heater water? The Claim: Never Drink Hot Water From the Tap Environmental scientists say it is real. The reason is that hot water dissolves contaminants more quickly than cold water, and many pipes in homes contain lead that can leach into water. And lead can damage the brain and nervous system, especially in young children.
@duubtuub30713 жыл бұрын
@@eagle18hls Agree: Great Knee Jerk idea... The question is: "To waste water, or energy?" Since "sav[ing] water for the whole city" is proposed, where almost all domestic water is recycled (as a result of past investment in water-treatment plants), the question becomes, "Since water is not really being saved, is it worth the resulting higher usage of energy for 'all house should be build like that' for mere convenience?"
@duubtuub30713 жыл бұрын
As the current pandemia has show, the "obvious" answer is probably not the best one.
@ssalinash5 жыл бұрын
Is this possible to install to shower faucet... Or how it works when showering? It's clear for handwashes
@MikeTrieu2 жыл бұрын
You're warming the entire hot water trunk. All upstream taps will benefit from quicker hot water start times. That's why you're supposed to install the bypass valve at the furthest hot water tap.
@pslowazo2 жыл бұрын
Doesn't this system mean that you will have Temped water in the cold water line when you want an Cold drink of water? If you don't want Temped cold water you would need to run a return line back to the tank. I'm I incorrect in my understanding?
@MikeTrieu2 жыл бұрын
Just run the pump only when you desire hot water. Tepid water from the cold line is a small, temporary price to pay for nearly instant hot water. Just give it a few minutes and the cold line will equalize to room temperature, just like before you installed the pump.
6 жыл бұрын
Where can we get one of these pumps and how much does it run?
@donaldbaker34376 жыл бұрын
comfort system pump. Groundfous mfg. Any plumbing supply house. Or call your local plumber.
@MrCoach19574 жыл бұрын
If you live in Calif. the State will provide you one and install for free. Go to www.orderebateprogram.com
@fishlanding2 жыл бұрын
yes, you explained this clearly..... gonna buy one asap
@san3796 жыл бұрын
wonder if this is allowed in CANADA
@paulmaxwell88516 жыл бұрын
Of course it is. I installed one in my home. Excellent product!
@kenmanx12986 жыл бұрын
100% correct... I got it.
@josereveles42147 жыл бұрын
What would happen if you do not put the pump you just put the valve sensor
@acman09266 жыл бұрын
Jose Reveles they are at very similar pressures and the water wouldnt move in the pipes.
@donaldbaker34376 жыл бұрын
wouldnt work, hot pressure needs to over power the cold.
@p4csl.s.l.4515 жыл бұрын
I got into this chat by chance, looking for the same answer. Would it be possible to just install the sensor? then as soon as I open the faucet, water would start circulating through the circuit but will not come out until it has reached the right temp. I still haven´t found the right answer.
@MikeTrieu2 жыл бұрын
@@p4csl.s.l.451 That's a rather vague question. Exactly which faucet would you open? If it's the hot tap, it'd be no different than if you had not installed the bypass valve at all. If it's the cold tap, you'd get increasingly warmer water until the thermostatic valve closed.
@ThreePhaseHigh2 жыл бұрын
This system works if you have a pre-existing home or if you can’t get to the plumbing lines anymore. However if you can there is a much much better much higher efficiency system. With the better system the pump only runs when you enter either your bathroom or your laundry room or wherever you are going to use hot water. If you use a timer it seems like it’s never on when you need it. So again use the system he’s explaining if you have no other way otherwise use the better system there is just no comparison. With his system if you’re gone for a couple of weeks and forget to shut the pump off it runs every day even though you’re not home with the better system the pump runs only just before you start to draw hot water.
@santiagoreynoso6012 Жыл бұрын
What’s other system do you have a mind?😊
@diamondpainter16 Жыл бұрын
And the much much better system is…..what??
@sr.gateau Жыл бұрын
Mystery system
@omarhernandez289oh7 жыл бұрын
now does the bypass valve go underneath the farthest fixture?
@acman09266 жыл бұрын
Omar Hernandez yes
@donaldbaker34376 жыл бұрын
yes sir. you can also use more than one manifold. $75.00 to purchase extra
@Omar-ge3fw6 жыл бұрын
Awesome...great explanation!!!
@NickelNationCoinsMore7 жыл бұрын
You failed to mention the high cost, why are they so expensive?
@donaldbaker34376 жыл бұрын
$400.00 pretty affordable.
@MD-cd7em3 жыл бұрын
KOLERFLO ON AMAZON HAS PUMP FOR 64 DOLLARS
@angelog.5808 жыл бұрын
The ONLY downfall is that you might have in certain cases luke warm water on the cold water side.....but the hot side will be perfect... That's why in NY if you building a new home you need a third pipe to anything that's 15' or more away from the water heater or heat source...which Is a complete different system than what the video shows but it's the best way with out connecting on the cold water side like it shows here...but a stainless steel recirculating pump costs around $450 plus labor and materials
@utube4greenfuture7 жыл бұрын
"might have in certain cases luke warm water on the cold water side." Name one time you Would Not have to wait twice as long for cold water with this system installed..
@xephael34852 жыл бұрын
@@utube4greenfuture well the time where the lukewarm water in the pipes had cooled to cold water... But yeah it's not ideal
@jackt61123 жыл бұрын
So by using the cold water line as the return, instead of waiting for hot water, you wait for cold, while using electricity for the pump, and heat your house in both winter and summer, using the least efficient system, the hot water heater, through a gel valve that needs to be replaced approximately every 5 years. I would have never thought of such a system. Interesting!
@yamaguy3 жыл бұрын
The valve closes once the water gets hot stopping the flow. That way the cold line stays cold. You may have to replace them every 5 years or so, but they cost about $50. $10/year is not a bad price to pay to not waste water.
@jackt61123 жыл бұрын
@@yamaguy If you have continually hot water in the hot line, it requires that you have continually warm water in the cold line.
@aayotechnology2 жыл бұрын
@@jackt6112 and more potential for bacteria
@hrcnick112 жыл бұрын
The small valve he held up in the video opens and closes to keep the cold line cold and the hot line hot. Once the hot water reaches the valve it closes. It does not run continuously.
@MikeTrieu2 жыл бұрын
Nobody said you had to keep the hot water line at temperature all the time. If you're smart about it, you'll have the pump running on a schedule or, smarter, triggered by a motion sensor in each room with a hot water tap.
@paulbisceglia68246 жыл бұрын
Only with a hot water tank??? What about an indirect hot water heater?
@trencher73 жыл бұрын
So I installed one of these in my kitchen sink, but realized there is another one underneath a bathroom sink. I also noticed I get hot water all the time in the kitchen regardless of if I select cold. Not sure what to do.
@allymacky40393 жыл бұрын
Maybe your pump is running constanly (too often). Therefore it is pumping hot water into the cold water line all the time. So you get hot watee from the cold water lines when you turn the tap
@geo8rge3 жыл бұрын
Are you saying you have 2 by pass valves? one in the kitchen and one in the bathroom.
@trencher73 жыл бұрын
@@geo8rge Yes I installed one under kitchen sink and realized later there is also one underneath my master bath sink. The kitchen is farthest location. Sometimes (not always) we get hot water from the cold side in kitchen sink as well as the fridge water dispenser. Kids say upstairs sometimes it's hot from cold side as well.
@newsshooter26 жыл бұрын
Will this product work on ANY hot water heater? I ask because my existing recirculating pump worked like a chanp on my water heater but as soon as I had my water heater replaced my existing recirculating pump does not work on the new hot water heater. So if I buy the product you show in this video, will it work on my new hot water heater that my old recirculating pump wouldn't?
@JoaquinChea7 жыл бұрын
I installed one of these several years ago now it no longer works, I know the pum is functional because I can hear and feel it running, what’s going on?
@b5a5m57 жыл бұрын
Your bypass valve may be stuck closed? Or perhaps you don't hear it "running" but you hear it "humming" like a ceased motor? Like the first couple seconds of this video kzbin.info/www/bejne/fH7ImJ1vlLSMm6c In that case your pump is bad and needs servicing / replacing.
@donaldbaker34376 жыл бұрын
are you just not getting quick hot water to the fixture?
@eagle18hls5 жыл бұрын
Look at the bright side and don't fix it. Can you drink water heater water? The Claim: Never Drink Hot Water From the Tap Environmental scientists say it is real. The reason is that hot water dissolves contaminants more quickly than cold water, and many pipes in homes contain lead that can leach into water. And lead can damage the brain and nervous system, especially in young children.
@henryt925411 ай бұрын
Unless your water heater is spiffy clean, and change the corroded anode rod, and flush your water heater several times a year, you will be drinking your potable water (cold side) mixed with your hot water. Imagine a home owner who rarely flushes his/her water heater and drinks from all the contaminates from your water heater. Even if you keep your water heater clean, heavy metal buildup in the water heater usually is several times more than your potable water. The only way to alleviate any health concern is to run a dedicated hot line from the water heater to the farthest plumbing with a re-circulating pump re-routing the hot water back into the drain side of the water heater without ever contaminating the cold water side. However, unless it is a new house already retrofitted with this line, it gets expensive installing a dedicated line.
@robertsimpson71138 жыл бұрын
Can the valve be serviced when it stops working or is it a throw-away and replace? This gel pack inside that you spoke of, is it sealed or can water get into it. I have a valve that seems to be not working and a replacement is half the cost of a new system. Doesn't that encourage new customers!!!
@donaldbaker34376 жыл бұрын
Bypass valve is not repairable, you replace it when it stops working. $75.00 for a new bypass valve.
@mikefa5891 Жыл бұрын
But the recirculating pump will be working at least 12-15 hours per day, 7 days per week, 365 days per year - and that's a lot of electricity wasted just to have hot water on demand. Wouldn't a small tankless water heater at each sink be more feasible?
@perfectalliby9 жыл бұрын
where exactly do you install the bypass valve?
@jaxv948 жыл бұрын
savage lmao
@southerncoyote7 жыл бұрын
at the furthest fixture from the hot water heater.
@philipelswick23426 жыл бұрын
perfectalliby .. . 'll m 'll 'll n m no mmm
@donaldbaker34376 жыл бұрын
you would generally install it in the furthest fixture from the water heater. Or in the bath where it takes the longest time to get hot water. you can also install another manifold if you have a long house with the water heater in the middle of the house.
@surplussean33646 жыл бұрын
The hot water tank is insulated. It seems inefficient if hot water is waiting in the pipes in older homes
@darrellpatton40084 жыл бұрын
The recirculation pump adds hot water convenience, not energy efficiency.
@MikeTrieu2 жыл бұрын
So trigger the pump on your preferred schedule or on-demand. Nobody said it had to be running all the time.
@bradhaenitsch11456 жыл бұрын
Number 1 their is no such thing as instant hot water it just means you will get it quicker depending on where your wh is. Do it the correct way and pre-plumb for it or run a 3/4 inch return and depending on how your home is rolled it might work a little faster and not for long because those little plastic manifolds go bad quick
@MikeTrieu2 жыл бұрын
5 years is "quick"?
@theshovster85057 жыл бұрын
How bout the the other half of the story?!,. Like where to install the manifold?!
@donaldbaker34376 жыл бұрын
under the sink, at the furthest fixtre from the water heater.
@jimu576 жыл бұрын
Where is the crossover point where you see payback for additional heating of the water vs using additional water waiting fir the hot to reach the fixture?
@donaldbaker34376 жыл бұрын
your just conserving water. An saving time. Thats all. No savings here.
@MikeTrieu2 жыл бұрын
For a tankless water heater, there is no appreciable difference as you'd still have to burn gas either way.
@jerrynieves85995 жыл бұрын
Once the water is hot and the valve stops the water were dose the water go the pump is still on ,until timer is off , the pressure is building until the Faucet is open
@-Stop-it5 жыл бұрын
Jerry Nieves - I’ve read that the pump has a recirc line within itself so it isn’t deadheading.
@mrpush28556 жыл бұрын
And a 15% increase in hot water cost....what cheaper a few gallons of water or the energy to heat it?
@donaldbaker34376 жыл бұрын
in California water is pretty precious here. Its up to you . probably another $2.00 a month in gas ( what we use here);
@adamdonofrio299010 ай бұрын
Brilliant!
@evenflow32565 жыл бұрын
I'm not comfortable having water that passed through the water heater then cooled in my drinking water. Is that even legal?
@eagle18hls5 жыл бұрын
Can you drink water heater water? The Claim: Never Drink Hot Water From the Tap But environmental scientists say it is real. The reason is that hot water dissolves contaminants more quickly than cold water, and many pipes in homes contain lead that can leach into water. And lead can damage the brain and nervous system, especially in young children.
@buseini5 жыл бұрын
Well ever hear of le
@rcl7008 жыл бұрын
Once the valve closes due to water temp, what does the pump do? If the timer is set the pump is running, but the bypass is closed due to temp achieved. Does it continue to pressurize the hot water line with nowhere to go?
@b5a5m57 жыл бұрын
It's most likely a "fan" type pump. It "blows" water like a fan blows air. If the line is blocked it will raise the water pressure probably a psi or something, but not much beyond that because that 1 psi is enough to push the water back through the "fan blades." So it shouldn't damage your pipes. This is just speculation though, as I have just thought about building something like this but luckily it already exists!
@alchance6626 жыл бұрын
Before spending some $ , anybody sure about this?
@ronaldfranklin61226 жыл бұрын
Al C yes this is a legitimate solution to retro fit your closed loop heating and cooling lines for instant hot water. If you have a large house 4500 sq feet or larger you can use more than one of the valves. The brand he is using Grundfous is excellent. This Old House on PBS has a great overview of four options. available to use on KZbin. Best to buy a unit with built in check valve back-flow preventer and a programmable timer
@patricktheplumber54826 жыл бұрын
Those things never work and you point out the obvious you have that pump running when you open a cold side fixtures the pump pushes hot water out of the cold inlet on the water heater and you get hot water on your cold side .
@donaldbaker34376 жыл бұрын
It is a booster pump, first you set the timer for the hours you will need the hot water quickly. Usually morning showers and evening cooking. when the bypass reaches its desired temp the pump is still running. very low h.p. 1/25th h.p. wet rotor design to run quiet and with no flow. it does pressurize the line just enough to over power the cold side.
@MoeDoe742 жыл бұрын
That was awesome
@stevenmorris31817 жыл бұрын
Its nice when you open the cold and get hot
@donaldbaker34376 жыл бұрын
save water, worth it to have a bit of warm on the cold side. Only where the manifold is installed.
@warrenmichael9186 жыл бұрын
it senses the temp change and closes off so no hot goes through to the cold side
@computerjantje3 жыл бұрын
What about instead of this electric energy costing system, you super insulate all hot water pipe in your house? If you put hot water into a thermosbottle it stays hot for a long time. Could the same not be achieved inside the hot water pipes? Combine it with thermostate driven fawcetts and you'll have instant warm water unless you have not used the system for a longer time. It also prevents heath getting away and heating water is costly by nature anyway.
@jasonbrown72586 жыл бұрын
Why not just get a on demand water heater? Most of them mount right under the sink.
@teknotech3 жыл бұрын
This can be good if you have natural gas or propane. If your home is all-electric, the on demand heaters need 80 to 100 Amps of current to operate. While they aren't on for lengthy time periods, if this current is needed while your A/C and oven are running, etc., you may exceed the power available in your home. This is a paraphrase of what I was told by a plumber when I inquired about it.