Plasto is the only Indian company in my view that provides such in-depth information about their products and their installation on platforms like youtube. Great Job - keep it up 👍
@RCPlastoTanksAndPipesPvtLtd2 жыл бұрын
Thanks for sharing
@ameerm489919 күн бұрын
Yes, my respects from Pakistan. I educated myself with their videos and I educated my plumbers with this too. Ever since this I changed first of all my 1985 year water tank GI pipe of 3/4 inch to 32mm PPRC which is same as 3/4 inch internal diameter but due to no rust and reduced friction in plastic pipes. The difference was immense 😊 I don't think Pakistani companies teach us this simple principle even as homeowners
@bipinpatel87524 күн бұрын
Real information.... Aaj tak ka sabse best video information 👌
@noelzacharias19372 жыл бұрын
This is an example of well produced,planned and executed project. The entire team behind the concept, scripting, graphics and Voice over needs to be commended.Thank you very much.As a consumer i have gained an insight and understanding about, how things work, why are they done as they are, and also answered a few questions i always had in mind but didn't know whom to ask as local plumbers are usually ill-educated.
@RCPlastoTanksAndPipesPvtLtd2 жыл бұрын
Thank you Sir
@parveshsharma84808 ай бұрын
Moter se angan Tak poni inchi pipe or vaha se tank Tak moti pipe hai thik hai vo ?
@akshay9584 Жыл бұрын
Thank you so much 😊 mujhe iss information se kafi kuch naya sikhne ko mila thankyou sir ❤️
@rajpandey42312 жыл бұрын
Very useful information no company share this kind of information thank you plasto
@RCPlastoTanksAndPipesPvtLtd2 жыл бұрын
So nice of you
@StayHappyKeepOthersHappy2 жыл бұрын
It's a wonderful video, very much informative....I was actually looking for such video to know, how can we solve the water distribution problem in our 4 floor building. I think this will help. Thank you so much Plasto Team for making and bringing this up on the youtube, Appreciated!
@RCPlastoTanksAndPipesPvtLtd2 жыл бұрын
Thank you Sir, glad to know that our videos are helpful.
your explanation is so good, i shall try in my house to get better result. thanking you,
@RCPlastoTanksAndPipesPvtLtd10 ай бұрын
You are most welcome
@gajendra20122 жыл бұрын
It help full video Sir 1 queries thi. 30 fit water(ground level se top) chadhane ke liye konsa pipe used karna padega
@RCPlastoTanksAndPipesPvtLtd2 жыл бұрын
one size bigger than pump outlet diameter
@Intusr2 жыл бұрын
This is a quality work hats off never seen such a great video from an India company thanks again.
@RCPlastoTanksAndPipesPvtLtd2 жыл бұрын
Glad you liked it
@gajananghodke81812 жыл бұрын
Amazing video keep it up plasto
@RCPlastoTanksAndPipesPvtLtd2 жыл бұрын
Thank you
@Hero-No-12 жыл бұрын
Yu are doing very good work.thanku plasto.
@RCPlastoTanksAndPipesPvtLtd2 жыл бұрын
So nice of you
@sherehind43842 жыл бұрын
Ek Request ye hai ki aap jo black colour se Hindi me likhte hai iska background watermark krke likhe taki piche ka matter dikhne me aasani ho
@Anaya-misrha2 жыл бұрын
Subtitles band kar dijiye hindi me dikhna band ho jayega
@prashantkori92162 жыл бұрын
Wo subtitle hai setting se on / off kar sakte hai
@probhatgogoi88102 жыл бұрын
The video is very informative. Thanks for the team.
@RCPlastoTanksAndPipesPvtLtd2 жыл бұрын
Thank you for your interest. For Product Details And Enquiry WhatsApp us on wa.me/917767007071/ OR Please fill these details: Name: Mobile no: City: Query: Our Team will contact you.
@musarratrazakhan438916 күн бұрын
Best explanation 🥰✅ G+4 floor ke liye water tank se individual pipe line lage ya only one pipe line se kam chal jayega?? I need good pressure n flow Plz reply or make complete detailed video😇🙌🏻
@sherehind43842 жыл бұрын
आपका बहुत बहुत धन्यवाद वा आभार ❤️ मैं ऐसी ही जानकारी चाहता था जो हमे बिना सर्च किए हुवे मिल गई आज 👍
Thank you for very very essential & good information
@abdulsami46072 жыл бұрын
Very nice explanation 👌👌
@RCPlastoTanksAndPipesPvtLtd Жыл бұрын
Thanks for liking
@ranjansah96502 жыл бұрын
Very usefull Pls keep it up
@RCPlastoTanksAndPipesPvtLtd2 жыл бұрын
Thank you Sir
@chandrakiransoni7135 Жыл бұрын
Sir, hme sirf ground floor me 4 bathroom ka connection krna hain... Kya 2" ke header pipe k baad pure distribution line inside bathroom ko 1*1/2" ka rakh skte hain kya....? Ya fhir 3/4" ka reducer line lagayen jo plumber krne bol rha h ? Aap bta skte hain kaun sa accha rahega 2" to 1*1/2" or 2" to 3/4" ?
@LifeLight.9 ай бұрын
Apka voice bohot achcha hai ❤
@dharmasagarpatil8485 Жыл бұрын
Very Good Infor!
@RCPlastoTanksAndPipesPvtLtd Жыл бұрын
Thanks a lot
@arun48462 жыл бұрын
Superb ❤️👍🎉
@musarratrazakhan438916 күн бұрын
1:25 sec pr aapne mm galat likhkhe hain ya inches??? 1.5" =40mm 1" = 25mm 0.5" = 12.5mm
@tarungupta64292 жыл бұрын
Ek question he.. air vent ka kaam sirf air ko bahar karna he. Ya persure banana he.... Agr tanki ka cap open ho to kya. Gravitational forse se air pipe line ke jariye bahar tab se nal se bahar nikal sakta he na.
@ganeshahirrao43402 жыл бұрын
क्या आप खेती की pipe line के लिये भी ऐसा video बना सकते है, क्युकी मोटर चाहे जादा Power की हो पाणी का फ्लो bohot कम रेहता है
@rajkumarp68512 жыл бұрын
Sir how much pressure is necessary for diverter to be installed? In G+1 bungalows where tank height is roughly 8-9 feet above Slab, how to achieve higher pressure to install diverter. Secondly, is it good to have separate outflow pipes from tank for individual floor or have one outflow with reducer line for good pressure?
@shankarkadam4459 Жыл бұрын
11/3/2023. प्लंबीग दिनाच्या हार्दिक शुभेच्छा कदम परिवार तर्फे कोल्हापूर,🛠️🌹🙏🚩 प्लंबर.
@AndrewChettri-m5n7 ай бұрын
can we put two air pipe?? one near tank and another from where the pipe in going down?
@imranpathan94422 жыл бұрын
Thank you very much sir 🙏 good information
@RCPlastoTanksAndPipesPvtLtd2 жыл бұрын
Thank you Sir and keep following us for more such informative content
@rpstatusb26963 жыл бұрын
Bhai jan aap ka. 1 newsubscribe .hmara aap ko full support bhia jan 🙏💕.
@RCPlastoTanksAndPipesPvtLtd2 жыл бұрын
Thank You.
@singhjaskiran2 жыл бұрын
I saw your video. I'm not knowledgeable person regarding plumbing. I have got my bathroom checked by UC and local plumber. We have to full water through motors from ground/parking level tank to Overhead tank. Due to this air gets in. It's a builder floor. Mine is 3rd of 4 floors. Overhead tank is above the roof height of 4th floors roof i.e. terrace above 4th floor. What i understand tank is at 2 floors above my 3rd floor. Same was situation in my previous place in delhi but pressure was high. I could easy was car in ground floor with high pressure. But here, still water pressure is always low in 1 of the 3 bathroom. 1 bathroom is OK pressure not high as normally it should be. In 2nd one even washing hands in sink is impossible forget using shower or Health faucet. 3rd bathroom is not used. Even kitchen sink pressure is okay or better. Never issue of air too. One plumber suggested to install 1HP motor on outlet. Can any of your team visit for consultation ⁉️🤔
@RCPlastoTanksAndPipesPvtLtd2 жыл бұрын
Thank you for your query sir. There can be many reasons for less water pressure in your house. Following are few steps you can do to cure water pressure issue: 1) Check the discharge line from the tank. Make sure ths discharge line is of the bigger diameter. 2) Make sure the discharge line is parallel to the ground and not inclined downwards to reduce the chances of air lock. And make sure that the Air vent is installed properly. 3) As shown in the video, the discharge line for the top floors should be bigger. As we go down the floor, reducer should be added to reduce the diameter of the pipeline. The bottom floor should have less diameter pipeline as the pressure will be more and the top floor should have more diameter pipe as the pressure is less. 4) Watch our 2nd video on 7 tips of how to increase water pressure- kzbin.info/www/bejne/omq0nnh7eKmnY7M, where we have explained the process of looping. Once you make a loop in your house, you will witness even distribution of water at every water discharge point.
@AS-pu7gj2 жыл бұрын
Very informative 🙏
@RCPlastoTanksAndPipesPvtLtd2 жыл бұрын
Thank You
@MrMoufyiedarz Жыл бұрын
Very good video
@vijayjangid78082 жыл бұрын
Very good explain sir
@RCPlastoTanksAndPipesPvtLtd2 жыл бұрын
Thanks and welcome
@muhammadadeel6060 Жыл бұрын
overhead tank se 1 inch ki line nikalen or sare bathroom me distribution line 1/2 inch ki hai. Uper se ane wali 1 inch ki line un se milaen. Ye sahi system hai?. Overhead 3rd floor pe hai. ground floor pe 2 bathroom, first floor pe 2 bathroom, second pe 2 bathroom hen. Thank you in advance. Question from Karachi, Pakistan.
@rohangupta1115 Жыл бұрын
Do you have a video on the pipe size to fill the water tank on different different heights?
@tarungupta64292 жыл бұрын
Thanki agr pura airtight ho to kya wo persure bana sakta he???
@RCPlastoTanksAndPipesPvtLtd2 жыл бұрын
Overflow pipe acts as airvent also
@tarungupta64292 жыл бұрын
Them why provide air pipe
@jayjinendra4872 жыл бұрын
Nicely explain Sirji..👌👌 Which CPVC pipe & fittings used for house plumbing ( for G+1 construction ) for hot and cold water. Is it 40 schedule or 80 schedule..As per water pressure which one is good for house plumbing. Please explain...🙏🙏
@muraritiwari55412 жыл бұрын
0
@jayjinendra4872 жыл бұрын
@@muraritiwari5541 What 0..🤦
@nipusarkar72 жыл бұрын
This is an excellent work
@RCPlastoTanksAndPipesPvtLtd2 жыл бұрын
Thank you...
@ashwinikumarshende2 ай бұрын
If height pipe is same and tap pipes are small then how is the pressure I am talking about first pipe from diagrammer which gives high pressure?
@sourabhsoni3603 Жыл бұрын
Please make a video of similarly drawing flow of pipes in bathroom with connections to toilet, basin, shower and geyser....
@rakeshkumarmaurya4162 жыл бұрын
Good information sir 😊🔥
@RCPlastoTanksAndPipesPvtLtd2 жыл бұрын
Thank you Sir
@kashinathbuwa99092 жыл бұрын
Front Load washing machine k liye kitne inch diameter ka pipe jodna hoga tank se tap tak?
@sandeepmathur77842 жыл бұрын
Sir I have single story house which has 12 ft height and my water tank is mounted there ,how can i install water purifier,shower as the pressure is very less. Wonderful explanation of plumbing thanks
Bhai plasto ki tanki lagwai hai pan ok itna garan aata hai ki haath jal Jaye, upaay bataye
@brass-123 Жыл бұрын
40 mm pipes if use for bathrooms where we have put 25mm. Is it ok
@nayandas85862 ай бұрын
How to drain and collect tankettes for cleaning excess water in water tanks
@inderjitparmar69322 жыл бұрын
Sir pipe 1 inch ja 1,5 inch m pani ek jasa he melayga
@MrKhabbu2 жыл бұрын
Bhai pressure and flow do alag cheez hey
@MrKhabbu2 жыл бұрын
Kaise aap samjhao
@brass-123 Жыл бұрын
We have e used each 40 mm pipe of each bathroom. Is that ok
@kartikghodkar6039 Жыл бұрын
Sir mera ye question he ke sir humare ghar me se pipe line mese bahot vibration hota he or aavaj ata or pura pile hilte he sir yesa kyu hota he
@RCPlastoTanksAndPipesPvtLtd Жыл бұрын
Maybe due to high pressure created by pump and 90 degree bends. We suggest bigger diameter pipeline, long bends or 2x45 degree bends or long bends and proper clamping of pipes
@EryuoRozarious9 күн бұрын
Please help me out of this l did ppr connection and connected plontank no pressure in the showers please help me
@rajeevbhardwaj5080 Жыл бұрын
Kindly make a video for pipe fitting from motor (Ground floor)to multiple floors without lossing water pressur.
@shivbhadrasinhjadeja2 жыл бұрын
Company ka ipo kab aayega ?
@ayush.kumar71 Жыл бұрын
How many bathrooms are connected with one 1.5 inch pipe tank outlet
@JagadeeshJags-f1z6 ай бұрын
What is the standard height for over head tank from terrace ?
@shailesh92262 жыл бұрын
Nice information
@RCPlastoTanksAndPipesPvtLtd2 жыл бұрын
Thank you
@engineershek3 жыл бұрын
jo pipe lines already installed h ghar me kya usko change kara sakte h bigger dia line se,kuch tod fod ki zarurat to nhi padegi?
@RCPlastoTanksAndPipesPvtLtd3 жыл бұрын
Sir, aap change kar sakte aapke plumber se consult karke
@MrKhabbu2 жыл бұрын
Jitna pipe diwal se bahar lagi hogi woh to asan I se badal jayegi . Concealed pipe ke liye tod food karni padegi. Bajay Aisa karne ke aap tanki ki height badha sakte ho kya . Agar nahi to use hamesha full rakho aur air pipe thoda lamba kar lo
@sourabhsoni3603 Жыл бұрын
Sir, could we do pipe fittings with 1'1/2" pipe like showed in video 2" from tank to 1'1/2" in bathrooms? Will taps and diverter fits tue 1'1/2" pipe ?
@valluri_avinash Жыл бұрын
Hi Can Plasto UPVC pipes used for connecting water pump out let to tank inlet or should we use cpvc ? . Yesterday I got plasto pipes for the same purpose and had this question.
@RCPlastoTanksAndPipesPvtLtd Жыл бұрын
"Thank you for your interest. For Product Details And Enquiry WhatsApp us on wa.me/917767007071/ OR Please fill these details: Name: Mobile no: City: Query: Our Team will contact you."
@Ratheeshkumar-pb5pk2 жыл бұрын
Awesome video 😊
@RCPlastoTanksAndPipesPvtLtd2 жыл бұрын
"Thank you for your interest. For Product Details And Enquiry WhatsApp us on wa.me/917767007071/ OR Please fill these details: Name: Mobile no: City: Query: Our Team will contact you."
@Suman-er5fc2 жыл бұрын
Need solution for air valve leakage .
@MrKhabbu2 жыл бұрын
What is the problem you are facing. Please share details and will give you a solution
@Suman-er5fc2 жыл бұрын
Flat top floor p hone k karan water pressure kam tha isliye plamber Hanging commode (without Flash tank) me water pressure barah ne k liye toilet k bahar wall me 2 pipe lagaya water Storage k liye . Flash krne se pipe me store kiya hua water Commode me speed se aaraha hai . Itna tak to thik tha but Storage pipe k upr me jo Air valve lagya hai us se water Leakage horaha hai speed se . Aur ye problem plamber solve nahi kar paraha hai . Kindly provide me proper solution.
@MrKhabbu2 жыл бұрын
@@Suman-er5fc bhai plumber ne galat salah di hey. Pressure hamesha hieght se banta hey . AAP ke liye best option tanki wala toilet wall mounted hi best solution hey . Flush tank mein jaroorat ke hisab se pressure ban jata hey aur 1/2” ki pipe se hi kam chal jata hey . AAP ne flush ke liye kitne inch ki pipe lagaye hey . AAP ke liye solution Storage wali do no pipe tanki mein jahan connect hoti hey wahan Usi size ki Tee lagaye . Tee ke uper usi size ki lambi pipe jo tanki se thoda unchi ho woh lagaye
@Suman-er5fc2 жыл бұрын
Sir avi to toile ready hogya hai isliye firse tor k nya Flash tank lagbana difficult hogya aur maine without flash tank wala hanging commode kharida hai isliye o v possible nahi hai. Aur top floor p hone ka karn ekdm presser nahi tha q ki tank just mera chand k upr hi tha , tank se jo main water pipe ghar tak aya is pipe ka distanse bhaut hi kam hai aur flash tank me ekbr flash krne se 3/5 litter water chorta hai but mera upr jis pipe se water aaraha hai us se ekbr me itna water lana impossible tha isliye plamber ye 2 Storage pipe lagya, ye 2 pipe ka niche ka hissa se water direct commode me aaraha hai flash krne se aur pipe ka upr ke 2 hisse me 2 air valve laga hua hai , jaise water tank me laga rehta hai oise. Avi main problem hai k 2 air valve jo laga hua hai udhar se water leakage horaha hai jorse. Ye problem solve karna hai. 2 Storage Pipe sayad 6/8 inch hoga.
@MrKhabbu2 жыл бұрын
@@Suman-er5fc kam complete ho gaya hey ya Abhi Baki hey. 6/8 inch ka pipe ki jaroorat nahi hey. Agar badal sakte ho to bahut achha. Toilet fit nahi kiya to wapas ho jayega . Agar yeh nahi ho sakta to ek hi upay hey jo bata diya hey. Air pipe ki height tank se unchi kar do yehi solution hey
@anunaryal34312 жыл бұрын
Hello sir ek quetion h
@RCPlastoTanksAndPipesPvtLtd2 жыл бұрын
Haa sir aap question puch sakte hain
@pallabbiswas7402 жыл бұрын
Is there need of air vent pipe if I use pump at ground floor for pressure
@RCPlastoTanksAndPipesPvtLtd2 жыл бұрын
NO, But pipe line should not have air pockets, so proper inclination of pipes is must
@manugupta11842 жыл бұрын
What is the height of the tank in the experiment? And how much height is required for 2 bar pressure?
@RCPlastoTanksAndPipesPvtLtd2 жыл бұрын
for 1 bar pressure we have to keep tank at an height of 10 meters. For 2 bar pressure we should keep tank at 20 meters height i.e. 6 floors of building
@sandeepjain61392 жыл бұрын
👍great edfort
@RCPlastoTanksAndPipesPvtLtd2 жыл бұрын
Thanks ✌️
@qasimrasheed77252 жыл бұрын
Which software are you using for making such animation
@ronaksoni27292 жыл бұрын
Great
@RCPlastoTanksAndPipesPvtLtd2 жыл бұрын
Thank You
@beingwarrior Жыл бұрын
Thanks a lot.
@RCPlastoTanksAndPipesPvtLtd Жыл бұрын
"Thank you for your interest. For Product Details And Enquiry WhatsApp us on wa.me/917767007071/ OR Please fill these details: Name: Mobile no: City: Query: Our Team will contact you."
@MohammedIrfan-vd7hd2 жыл бұрын
Super hai
@RCPlastoTanksAndPipesPvtLtd2 жыл бұрын
Thank you for your interest. For Product Details And Enquiry WhatsApp us on wa.me/917767007071/ OR Please fill these details: Name: Mobile no: City: Query: Our Team will contact you.
@sajeelovenet2 жыл бұрын
TQ sir
@hotnews92673 жыл бұрын
So reducer line is best right???
@RCPlastoTanksAndPipesPvtLtd3 жыл бұрын
start with bigger and reduce after you distribute
@u4vishal3 жыл бұрын
Full line with bigger pipe is best
@JupitarMars Жыл бұрын
How can i buy for my retail shop
@RCPlastoTanksAndPipesPvtLtd Жыл бұрын
Thank you for your interest. For Detail And Enquiry Whatsapp us on wa.me/+917767007071 OR Please fill these details or Send Visiting Card Name: Mobile no: City: Query:
@bhagavadsharan2 жыл бұрын
Sir please help. Our plumber have installed all pipes having same diameter i.e.3/4 inches told by him. Tank is placed on roof of 1st floor. Bathrum on first floor have low pressure in comparison to that of ground floor. How to fix this issue? (Provided: tank have two outlets, first floor have two bathrums. Both bathrums attached with different outlets. But one have low pressure another is ok. )
@RCPlastoTanksAndPipesPvtLtd2 жыл бұрын
use reducer line as shown in the video, or use parallel lines upto first floor
@mbelectrical12183 жыл бұрын
Nice
@RCPlastoTanksAndPipesPvtLtd3 жыл бұрын
Thanks
@samarshaikh57642 жыл бұрын
Ek baat batao 1 inch 25.4 mm hota hai toh tumne 1/2 inch 21.3mm kaise bataya hai
@MrKhabbu2 жыл бұрын
UPVC ka diameter system alag hey
@sonukaushik89752 жыл бұрын
Pipe ka internal dia 13 mm hota hai
@yogeshplumberrajnandgaon282410 ай бұрын
बहुत हि सुन्दर लेकिन मै इसे5 साल पहले कर चुका हु
@kanzariyavishnubhai8051Ай бұрын
1"=25.4mm hota he n?
@musarratrazakhan438916 күн бұрын
Wohi to by mistake hue hai shyd
@Factomazaofficial2 жыл бұрын
Thanks
@RCPlastoTanksAndPipesPvtLtd2 жыл бұрын
Welcome
@gopalgopalkumar89642 жыл бұрын
Please send me pipe line chart
@RCPlastoTanksAndPipesPvtLtd2 жыл бұрын
Thank you for your interest. For Product Details And Enquiry WhatsApp us on wa.me/917767007071/ OR Please fill these details: Name: Mobile no: City: Query: Our Team will contact you.
@AnilPatel-yi8ii2 жыл бұрын
ધન્યવાદ
@bikashmoharna7832 жыл бұрын
Hlo sir 21.3 mm is equal to 1/2 inch hota he kya. It's near about 1 inch hi he. Golot information kyun de rehe ho sir
@sonukaushik89752 жыл бұрын
21.3 bahar ka dia hota hai and andar ka dia 13-14mm hota hai islia isko 1/2 inch pipe bolte hai
@vinodxxx1581 Жыл бұрын
1½ inches approx 40mm, not 48.2
@shankerpatel60592 жыл бұрын
आम भाषा मे बताए तो ज्यादा अच्छा होता। जैसे 1 इंच 2 इंच पाइप।
@RCPlastoTanksAndPipesPvtLtd2 жыл бұрын
Thank you for your feedback sir..
@MantuYadavYM2 жыл бұрын
❤️❤️❤️👌👌👌
@dattatrayghadage478 Жыл бұрын
आपके कंपनी मे खुद के प्लंबर रखिए और जब कस्टमर वॉटर टॅन्क लेने आय गा तो उसे विथ फिटिंग चार्जेस बोलिये और जो कंपनी का प्लंबर नहीं चाहता है तो उसे प्राइवेट प्लंबर को हायर करने दो अगर कंपनी का प्लंबर रहेगा तो सब अच्छी तरह फिटिंग करे गा और कंपनी की वारंटी भी मिलेगी
@adnanshah06 Жыл бұрын
Nothing explain wrll
@raghunuthi65892 жыл бұрын
Good information 🙏🙏
@RCPlastoTanksAndPipesPvtLtd2 жыл бұрын
Thanks
@nitinmeena132 жыл бұрын
Very informative
@RCPlastoTanksAndPipesPvtLtd2 жыл бұрын
"Thank you for your interest. For Product Details And Enquiry WhatsApp us on wa.me/917767007071/ OR Please fill these details: Name: Mobile no: City: Query: Our Team will contact you."
@vikasdhiman23142 жыл бұрын
Good knowledge
@rahemathkhan4352 жыл бұрын
good explanation sir
@RCPlastoTanksAndPipesPvtLtd2 жыл бұрын
Thanks for liking
@tuhinbarai75922 жыл бұрын
Great information 🙏👍
@RCPlastoTanksAndPipesPvtLtd2 жыл бұрын
Glad you Liked it Sir. Let us know any other topic that you think is an issue in Plumbing and we shall try to make a video on the solution of the same.