HOW TO INSTALL A THERMAL EXPENSION TANK ON WATER HEATER

  Рет қаралды 176,827

PLUMBING WITH TIM

PLUMBING WITH TIM

Күн бұрын

Join me today as i bring a water heater up to code and show you how to install a thermal expansion tank!

Пікірлер
@avag1334
@avag1334 4 жыл бұрын
Don't you need to check the air pressure in the tank to match the water pressure coming into your house?
@mikemaggs3273
@mikemaggs3273 2 жыл бұрын
Wondering the same...
@Nokout626
@Nokout626 2 жыл бұрын
You definitely have to..
@JohnRidersoldoutforjesus
@JohnRidersoldoutforjesus 2 жыл бұрын
Yes
@Runflatred
@Runflatred Жыл бұрын
Of course.
@chadpayne2472
@chadpayne2472 Жыл бұрын
How do you do that ?
@beaunhead
@beaunhead 11 ай бұрын
Wish you would've shown the soldering... Great video, good detail and explanation
@saranjesse23
@saranjesse23 3 жыл бұрын
Excellent job explaining the steps and why you’re doing what you’re doing! Thanks.
@barryrosenthal7337
@barryrosenthal7337 4 жыл бұрын
didn't ream the copper pipe after he cut it, didn't change that old shut off valve with a new better ball valve, didn't test water pressure to make sure the expansion tank matched with air pressure.
@wcsd9577
@wcsd9577 3 жыл бұрын
and no dielectric unions, and used type M copper
@chrispinette8303
@chrispinette8303 3 жыл бұрын
They are dielectric nipples coming out of heater
@forextrinitrader
@forextrinitrader 3 жыл бұрын
@@chrispinette8303 do Rheem water heaters use dielectric nipples? I installing a AO Smith and the manufacturer says dielectric unions are required.
@forextrinitrader
@forextrinitrader 3 жыл бұрын
He probably did it off camera, it hard to video everything thing when on a actual job.
@pipingdogtooth
@pipingdogtooth 3 жыл бұрын
@@wcsd9577 How can you tell it's not type L or K?
@johnblack2427
@johnblack2427 5 жыл бұрын
Good video how though it was more about the copper than the actual tank. Did you add air to the tank, and what is the pressure in the tank installed in relation to the pressure in the plumbing system?
@RoyBaty
@RoyBaty Жыл бұрын
Old school. Thanks for showing how it's been done for 100 years. Too many videos show the new compression tools that most of us can't afford or the shark bite pieces that are expensive. This is cheaper and with a few plumbing tools and practice most of us can master this method. One thing, show us your soldering. Some people don't realize you need to heat the elbow, not the opening. When the entire fitting reaches the correct temperature the solder will be drawn all the way in.
@johnhuggins5021
@johnhuggins5021 3 жыл бұрын
I noticed you did not install a strap to the expansion tank to support it using the surrounding the wall. Has it been your experience that doing this step is not really necessary even if the tank fills with water, empties, fills, empties, etc. several times over its lifetime? Oh, and does it matter whether or not the schrader valve end is at the top of the tank or at the bottom? Or that depend on the manufacturer's recommendation for the install? Thanks for any feedback.
@BearNorth2838
@BearNorth2838 Ай бұрын
Great video.. Per codere you supposed to add supplemental support to that tank?
@timc1341
@timc1341 3 жыл бұрын
Great vid Tim Expansion tanks are not required by code in florida unless the house is a "closed system" i.e. some sort of check valve or backflow preventer is in place inhibiting the expansion of the hot water back into the distribution system.
@homesteadhaven2010
@homesteadhaven2010 5 ай бұрын
Not required in Southern Mississippi..
@Travis-bu6yo
@Travis-bu6yo 2 жыл бұрын
Did you not ream the pipe after you cut it?
@Real_Rob_Reels
@Real_Rob_Reels Жыл бұрын
Did you debur the inside of the 6" pipe you cut so you don't get turbulence? Also, you never took the house water pressure and adjust your expansion tank to that pressure. Always a good rule of thumb to check pressures before the install. Most 2.5 gallon Exp. Tanks come at 50 psi but it's shooting in the dark until you get some hard data.
@adolfomares23
@adolfomares23 11 ай бұрын
Whi didnt u use a union? With another nipple going to the water heater? I think it'll look cleaner...
@sonshenshomestead7668
@sonshenshomestead7668 Жыл бұрын
Is it necessary to prep the water expansion tank with pressurized air first?
@amarinayat8879
@amarinayat8879 5 жыл бұрын
Excellent video, thank you! I have a couple of questions.... since I am planning installation in two locations in attic, one with very limited space.... 1. How far from the inlet side can an expansion tank be installed. Say, would it serve its purpose if I ran a 10 foot pipe from the inlet and installed the expansion tank sideways, or upside down? Shouldn't the air valve on the tank be easily accessible for maintaining pressure? 2. How do you size an expansion tank for a 40 gal vs 75 gal water heater? 3. How do you feel about using pex instead of copper? Thanks in advance for your help.
@Resq28
@Resq28 2 жыл бұрын
Great questions, I wish he would get back to some of these questions because I need the answers as well. Thank you for asking them.
@jgg204
@jgg204 4 жыл бұрын
The water heater will fail well before 30+ year rated sharkbite ever will. And when the water heater fails, you just replace the sharkbite valve flex lines with it like you would a dishwasher or a washing machine. In and out replacement in less than 30 mins
@josem2468
@josem2468 3 жыл бұрын
You hire a hack if they use Sharkbites. Only for homeowner use.
@jgg204
@jgg204 3 жыл бұрын
@@josem2468 and this is a home, you moron
@garygray4664
@garygray4664 3 жыл бұрын
Sharkbites are fine. I personally wouldn't use them right at a hot water heater but about 16-18 inches away would be better.
@grow8094
@grow8094 2 жыл бұрын
I I am a plumber never use shark bites There’s way better stuff to use I agree with the guy make the video you don’t use shark bites If the homeowner wants to use one that’s his choice but if you’re paying someone to do a job they should do it right
@jgg204
@jgg204 2 жыл бұрын
@@garygray4664 they are rated for 12" away from tank nipple
@5tr41ghtGuy
@5tr41ghtGuy 4 жыл бұрын
Just what I needed to see today to get a new heater installed. Thanks so much for posting!
@strongsadventures
@strongsadventures 5 жыл бұрын
Thank you for taking your time to show this Tim. It is hard enough to do the Job fast and most important the right way so i will say this thank you for sharing how to do this. Ain't gonna be no leaks if you did it.
@rickjames6948
@rickjames6948 Жыл бұрын
Check house water pressure. Adjust thermal expansion tank pressure accordingly. Do this with the hot water tank with zero pressure inside it. Don't want water pressure pressing into the thermal expansion tank fudging the thermal tank pressure.
@PetePuebla
@PetePuebla 3 жыл бұрын
In my opinion I think you're right about securing it snugly. I don't think you have to use a wrench. You just need a good seal.
@howardbardwell1265
@howardbardwell1265 Жыл бұрын
Do you air up the bladder on the expansion tank? I thought it needs to be aired up to 60 to 75 psi.
@pallsmortion4750
@pallsmortion4750 2 жыл бұрын
Great job, in the UK we need to fit a pressure regulator on the inlet, do you not need to? Thanks
@estuardoerazo9998
@estuardoerazo9998 Жыл бұрын
Isn’t a vacuum breaker code in Florida?
@Honestandtruth007
@Honestandtruth007 5 ай бұрын
Just Subscribed for your Expertise 👍👍
@keithcastleberry3993
@keithcastleberry3993 4 жыл бұрын
Dont use shark bites but let's screw copper fittings to galvanized pipe to promote electrolysis. Nice.
@chrispinette8303
@chrispinette8303 3 жыл бұрын
They are dielectric nipples with plastic cores
@pxxexxs
@pxxexxs Жыл бұрын
He is using dielectric nipples he talks about the plastic in them.
@nikkogarcia7104
@nikkogarcia7104 5 жыл бұрын
You didn't charge up that expansion tank with air matching the pressure to the incoming water supply. That tank on there isnt doing anything useful without a proper charge.
@PLUMBINGWITHTIM
@PLUMBINGWITHTIM 5 жыл бұрын
I’m glad you guys mentioned this as I realize that I left this step out. I will be doing a follow up video about this critical step. Thanks for watching!
@darienlandry3244
@darienlandry3244 5 жыл бұрын
Nikko Garcia those typically come precharged just saying
@coachmattc
@coachmattc 4 жыл бұрын
@@darienlandry3244 Not enough. Needs to match the system pressure.
@brandonmunsin9310
@brandonmunsin9310 3 жыл бұрын
lil tip, they usually always come pre charged @20lbs.. an easy way to figure out what to charge up too, pressure test the house , thtl be your # then use air compressor. never charge passed 80lbs. usually 50 is where it’s at.. yes most people don’t charge them, makes it pointless to have if not charged... anyways good vid! keep it up man, stay positive! im an commercial/industrial plumber. plumb everyday on big systems , an no matter what you do somebody will always have something to say lol everyone thinks they know it all, an most likely really don’t know shit ..wish people were more positive
@pipingdogtooth
@pipingdogtooth 3 жыл бұрын
@@PLUMBINGWITHTIM Can you provide a link to the update?
@pepelepew158
@pepelepew158 4 жыл бұрын
Thank you.!!!!! This helped me out a lot. Awesome video again ty so much for taking the time and explaining it step by step.
@Gary-vq4ht
@Gary-vq4ht 8 күн бұрын
Test water pressure and fill expansion tank with correct matching air? Hold second wrench on the copper threaded fitting to protect soldered joints when tightening
@Silvertheta
@Silvertheta Жыл бұрын
Do you need to add air into the expansion tank or is it preloaded with air already? TY
@buck3093
@buck3093 5 жыл бұрын
Shouldn’t there be a couple Dielectric Unions on there? (Going directly from copper to galvanized)
@PLUMBINGWITHTIM
@PLUMBINGWITHTIM 5 жыл бұрын
Good question. Back in the day when water heaters had galvanized nipples These days they are made from a different alloy so it’s no longer required
@buck3093
@buck3093 5 жыл бұрын
PLUMBING WITH TIM That’s good to know! Thanks :-)
@nadeemmian7750
@nadeemmian7750 6 ай бұрын
wondering why you install expansion tank on the cold line. should it not be on the hot water line ?
@jackjones1727
@jackjones1727 3 жыл бұрын
To replace the heater, you have to unsweat the joints. Is that normal?
@diezak2990
@diezak2990 3 жыл бұрын
Should have used dielectric union to go from galvanized to coppers I'm an HV AC installer replacing water heater and furnace for realtor selling house I replaced water heater today in a tight spot old house with galvanized fittings and I didn't like came out because I had to install the expansion tank before the shut-off should I change it
@williammorris3303
@williammorris3303 2 жыл бұрын
Can the expansion tank be to far away? I did a hot water tank , electric 40g tank , closed water system so I put in a 1.5g expansion tank, pumped it in the same way I always do. T&p valve blew as soon as the tank came up to temp. I thought how crazy that a new tank had a faulty valve, so I changed it. But it still blew the valve.
@RichRich007
@RichRich007 2 жыл бұрын
how can you put a wrench on there to "snug it all the way up" when its soldered in place?
@mitxchellmitxchell6564
@mitxchellmitxchell6564 2 жыл бұрын
where are you located I'm in central Florida and needing of an awesome plumber like yourself.
@PLUMBINGWITHTIM
@PLUMBINGWITHTIM 2 жыл бұрын
I moved to western Kentucky
@kawaiibtslover1012
@kawaiibtslover1012 4 жыл бұрын
No hammer arresters required in Florida?
@nathanoj894
@nathanoj894 3 жыл бұрын
Isn't red copper type M a thinner gauge?? Or is that type L ?? I'm from California and we use blue copper type L cuz it's a thicker gauge and also cuz hot water is unforgiving. Just a thought thanks for vid.. type M is OK for pressure relief valve
@Monkeymanxxl
@Monkeymanxxl 3 жыл бұрын
What state are you in? I don’t think this will pass inspection in California but I am not sure
@PLUMBINGWITHTIM
@PLUMBINGWITHTIM 3 жыл бұрын
Florida
@Monkeymanxxl
@Monkeymanxxl 3 жыл бұрын
Thank you for your quick response, nice work looks very clean. After my comment I watch the video to the end and heard you say Florida, California is a pain in the ass
@BillAnon
@BillAnon Жыл бұрын
How do you tell what size expansion tank you need?
@neogeo8267
@neogeo8267 2 жыл бұрын
No dielectric unions?
@brianrobertson1211
@brianrobertson1211 4 жыл бұрын
Did you ream your pipe?
@jamesrecknor6752
@jamesrecknor6752 Жыл бұрын
Good teaching ability
@tty3146
@tty3146 2 жыл бұрын
I have 2 heaters and expansion tank for each. one has pressure 55 psi and other has 75 psi. system pressure is 60 psi. Recently I am getting warm water from cold faucet. I changed tub cartridge but still getting warm water. What can be the issue? Faulty heat trap?
@joecarini9958
@joecarini9958 2 жыл бұрын
Very informative..however, not sure if the music background was necessary, a bit distracting.
@MonkeyManMechanicals
@MonkeyManMechanicals 5 жыл бұрын
no dielectric unions or unions at all???
@stevenmott4158
@stevenmott4158 5 жыл бұрын
Christopher Segar why would he need a dielectric Union he is using all copper not mixing metals
@darienlandry3244
@darienlandry3244 5 жыл бұрын
Steven R Mott he is mixing, you cannot adapt copper to galvanized without having brass in between it, flexes or dielectric unions, Electrolysis is real my friend, and Code
@stevenmott4158
@stevenmott4158 5 жыл бұрын
The nipples that come with the water heater are not galvanized
@stevenmott4158
@stevenmott4158 5 жыл бұрын
Heat trap nipples are already dielectric
@footlongburrito
@footlongburrito 4 жыл бұрын
Its not about being dielectric anymore it's still code to use unions, now someone will have to cut the copper pipe to do anything... what if he couldn't start the heater because of a issue and had to return the heater and get a new one? Now without unions you can't without cutting pipe. This isn't code
@desertcamel3573
@desertcamel3573 2 жыл бұрын
where do the expansion tank go hot or cold side? if on hot side what's happens?
@onemorething100
@onemorething100 4 жыл бұрын
Hi Tim. Hopefully you can help me. I've had issues with high pressure in my home. At first I tried to adjust the Pressure regulator but soon realized it was not working. So I replaced it. I set the pressure at 60 and put a gauge on overnight but I'm still getting high readings. It seems to coincide with the HWT firing up. I don't have an expansion tank installed. Can thermal Expansion cause high pressure through out plumbing? My Neighbor said the expansion would only occur in the HWT not the home plumbing and an Expansion tank would not lower the pressure. I have a hard time believing the regulator is bad. any thoughts? Thank You
@matthewmusselman373
@matthewmusselman373 4 жыл бұрын
The rise in pressure starts at the water heater from thermal expansion. But without a place for the pressure to go it passes through the water heater and pressurizes the cold water line as well. They are one common water system unless they are separated by check valves. The expansion tank could help. The pressure surge could be caused by something else also. Quick acting valves like the ones used in irrigation or at your washer machine can cause a water hammer that may give you a high pressure reading.
@onemorething100
@onemorething100 4 жыл бұрын
@@matthewmusselman373 Thanks Man. A few weeks ago Installed A pressure tank and that seemed to correct the problem.
@jeffreyplumber1975
@jeffreyplumber1975 4 жыл бұрын
THERMAL EXPANSION install tank and call me in the morning!
@stevie2132
@stevie2132 4 жыл бұрын
Not legal in California..you need flex supply lines just in case of a earth quake.wish we can do it that way
@blueg3027
@blueg3027 4 жыл бұрын
Has California ever heard of earthquake straps?
@drdez
@drdez 4 жыл бұрын
@@blueg3027 I thought the straps keep the tank from tipping over not the pipes of it breaking because of the flexing of the pipes/house.
@pj3p488
@pj3p488 4 жыл бұрын
Sharkbites in earthquake zones, ok. KZbinr, DIY, and lazy plumbers love them. How often have I gone back to their work and removed the flexes because they went bad and started leaving black goo in their hot water? Quite often. Heater tip, if it has a plastic drain valve it is a crap heater.
@josem2468
@josem2468 3 жыл бұрын
How true. Needs a full port drain valve.
@garyteague4480
@garyteague4480 5 жыл бұрын
I would only ask why you didn’t put a Union in the line so when that heater is replaced it would make it simpler
@Gabester64
@Gabester64 4 жыл бұрын
Thank you going to give it a try this weekend. helped out a lot.
@eallevato
@eallevato Жыл бұрын
I am reading the installation instructions for a BACKSTOP expansion tank and they caution you to install the tank vertically with the air side in the downward position ONLY. Why is your installation backwards?
@smidjee1225
@smidjee1225 5 жыл бұрын
Thanks for the vid and info! What size expansion tank do you recommend for a 50gallon water heater? Or does it really matter?
@jinpark5324
@jinpark5324 5 жыл бұрын
Smidjee it depends on 3 factors:1 size of water heater 2 your household water pressure 3 water heater temperature setting. Referring to the following doc page 2 figure 1 to find the right size of expansion tank you need. www.amtrol.com/wp-content/uploads/2019/02/9015-942-01_19-Thermal-Expansion-Tank-IO.pdf
@fish4food0071
@fish4food0071 Жыл бұрын
I call b.s. on the shark bites. They are built to last as long as your hot water heater and in most cases outlive a soldier joint. I have done home repairs and remodels. I have been called to dozens of pipe leaks that were failed soldier joints and only one leaking shark bite and it leaked due to pipe not cut true and or deburred. And you check your incoming pressure before you install your expansion tank so you can pressurize it to match.
@Grizzleback07
@Grizzleback07 8 ай бұрын
I have them on several connections that are in the open and not a single leak. You HAVE to debur the pipe and cut it straight like you said in order for them to fully seat and make a good connection. These guys are stuck in the fittings of the 80's when they were not as good.
@herrickinman9303
@herrickinman9303 4 жыл бұрын
Metal pipes soldered to the water heater would not pass inspection in California. California requires flexible water hoses and a flexible gas hose in order to minimize the chance of breakage during an earthquake. Sharkbite connections are allowed in California. You'll find Sharkbite hoses and connectors at Home Depot stores and Lowes stores throughout the state.
@dmdx86
@dmdx86 2 жыл бұрын
Sharkbites are allowed pretty much everywhere. Plumbers just don’t like them for various and often specious reasons.
@fish4food0071
@fish4food0071 Жыл бұрын
They do not like shark bites because it shorten there time on job that can be charged. So the don’t make as much money!!
@WinnTeam
@WinnTeam Жыл бұрын
@@fish4food0071 I don't like them because as an Engineer - i see them as less reliable than other options, my preferred is still copper pipes sweated together. Nothing to do with a plumber making more money - everything to do with failure points.
@kevinh9262
@kevinh9262 Жыл бұрын
@@WinnTeam I'm an engineer and I have used them many times. They work great.
@tick_go5989
@tick_go5989 Жыл бұрын
I recently experience corrosion rust build up where copper connection to the steel nipple on my water heater tank. With some quick research online turns out my viewers are correct about dissimilar metal reaction causing the rust. Sharkbite flexible possibly a better option to prevent corrosion!
@quantumspinup7418
@quantumspinup7418 3 жыл бұрын
Can you use silver solder vs regular solder for the pipe connections?
@globeflicker9216
@globeflicker9216 3 жыл бұрын
Why would you spend that kind of money.
@quantumspinup7418
@quantumspinup7418 3 жыл бұрын
@@globeflicker9216 just more familiar with silver solder brazing vs soldering. Most of my raw materials are from at least a decade ago. Cost is not an issue.
@globeflicker9216
@globeflicker9216 3 жыл бұрын
QuantumSpin You can use silver on potable, but frankly I’d sell it and make a few bucks (a new roll weighs about a pound) 95/5 is far cheaper. Silver solder is also great for refrigeration lines (Stay Brite #8). Sterling has a silver bearing one that’s half that cost but I would not use it on refrigeration, hydronic heat or potable it’s ok.
@Scorpiomaj27889
@Scorpiomaj27889 5 жыл бұрын
Hello, any specific reason you don't want sharkbites? Are they not technically up to code?
@darienlandry3244
@darienlandry3244 5 жыл бұрын
There a hack job
@dmdx86
@dmdx86 2 жыл бұрын
Sharkbites allow DIYers and handymen to do plumbing jobs that normally you’d used to call a licensed plumber for. Sharkbites work and last if you follow instructions. Problem is unskilled people often don’t follow instructions (don’t deburr their copper and/or don’t insert the fitting to full depth) and you end up with leaks and they get a bad rep as a result.
@kawaiibtslover1012
@kawaiibtslover1012 4 жыл бұрын
No hammer arrestors required?
@LogginzLyfe
@LogginzLyfe 2 жыл бұрын
I replaced my expansion tank today and now I have very little pressure and hot water. Any ideas what’s wrong? I didn’t think the tank had anything to do with that. It was working fine before the replacement.
@nolantanaka565
@nolantanaka565 5 жыл бұрын
Do you need a check valve too?
@PLUMBINGWITHTIM
@PLUMBINGWITHTIM 5 жыл бұрын
It’s not required on residential homes
@forextrinitrader
@forextrinitrader 3 жыл бұрын
Do expansion tanks really need to be 18 inches away from the cold water valve? Is the measured in straight line along the copper and includes that 6 inches up from the T adapter?
@davidmaddox6829
@davidmaddox6829 4 жыл бұрын
Don't you need to confirm the pressure of the new tank before installing it?
@PLUMBINGWITHTIM
@PLUMBINGWITHTIM 4 жыл бұрын
Yes indeed and I made a video shortly after this one explaining that. Thanks for watching!
@kokoyhawaii
@kokoyhawaii Жыл бұрын
Copper is fine and fun to work with, but never had a problem with sharkbite
@pipingdogtooth
@pipingdogtooth 3 жыл бұрын
Will the teflon tape be enough to prevent a reaction between the copper pipe and the expansion tank?
@PLUMBINGWITHTIM
@PLUMBINGWITHTIM 3 жыл бұрын
kzbin.info/www/bejne/anTIfntuqM5qjbc
@pipingdogtooth
@pipingdogtooth 3 жыл бұрын
@@PLUMBINGWITHTIM Thanks for the link!!! and all the great information!!!!
@jayham1970
@jayham1970 2 жыл бұрын
I was thinking that you had to check the water pressure in the house, and then you had to add air pressure to the expansion tank to match that of the water pressure. Has the design changed in expansion tanks so that that process is no longer needed?
@kevinh9262
@kevinh9262 Жыл бұрын
No
@Sparkdawg1776
@Sparkdawg1776 2 жыл бұрын
Beautiful solder joints, wish you would have showed it
@eduarm1824
@eduarm1824 4 жыл бұрын
my name is Edwin from Honduras and I love you body. nice job !!!!!
@MyGodzilla33
@MyGodzilla33 Жыл бұрын
How come you didn't mention put the water pressor air in to expantion tank before put them on?
@anthonypapa8676
@anthonypapa8676 2 жыл бұрын
Can you mount that tank on its side or does it have to be up and down
@Grizzleback07
@Grizzleback07 8 ай бұрын
I mounted mine on its side because of room constraints and used strapping to help support it. No problems yet in the past 8 yrs.
@TheAwesome2626
@TheAwesome2626 5 жыл бұрын
Right on! Great video
@BOSS_805
@BOSS_805 10 ай бұрын
Why are you not using di electric unions?
@timrobinson9897
@timrobinson9897 5 жыл бұрын
Tim Job isn’t done quite yet. You need to check the water pressure from the city coming in. Easy to do just put a pressure gauge at a hose spigot preferably near where the water comes in. Take that pressure and use a small air hand air pump like a bicycle pump to pump up the expansion tank. On the expansion tank is an air valve it looks just like the one on your car tire. The tank needs to be inflated to the same pressure as the city. Otherwise the expansion tank is just a decoration and provides no benefit.
@PLUMBINGWITHTIM
@PLUMBINGWITHTIM 5 жыл бұрын
Very good point my friend. Thanks for sharing that. Much appreciated.
@darienlandry3244
@darienlandry3244 5 жыл бұрын
Tim Robinson those typically come pre-charged
@kevinh9262
@kevinh9262 Жыл бұрын
@@darienlandry3244 But you need to match the house water pressure. The tank may only be charged to 20 or 40 PSI from the factory. I just installed one at a house that had 60 PSI. Had to pressurize the tank. If you do not balance it, it will not work properly.
@davew657
@davew657 Жыл бұрын
The info I'm looking for is a bit more involved. For instance, if you check your pressure with a gauge, are you getting a true reading if the water heater just heated up and is pushing it's thermal expansion back towards your gauge? He turned off the breaker but that did not cool off the water (in water heater) and thus, did not stop the back pressure of the thermal expansion. So, should you do this when water heater is cold, warm, or hot ? @@kevinh9262
@914sam5
@914sam5 3 жыл бұрын
Great job, I like to use four 45’s and a 90 after the T for the expansion tank 👍👍
@martinmoffitt4702
@martinmoffitt4702 Жыл бұрын
nice neat and simple!
@Homepros888
@Homepros888 5 жыл бұрын
Is that type M copper you installed on the cold side (red mark) usually type L is suggested for water (blue). Type M is only for heating
@mastersfan04
@mastersfan04 5 жыл бұрын
Every service plumber worth his salt uses L pipe
@darienlandry3244
@darienlandry3244 5 жыл бұрын
You can use M if you want, just not underground
@SammyEddie
@SammyEddie 5 жыл бұрын
mastersfan04 is this video for professionals? Doubt it since he shows how to use Teflon tape. Any help is appreciated. I thought copper pipe was copper pipe.
@mastersfan04
@mastersfan04 5 жыл бұрын
@@SammyEddie this video is for DIY people, but it's bad advice. Water heaters should be connected with flex lines or unions , and the thermal expansion tank should have air pumped in to match the static water pressure. There are good videos of that. The video is correct about soldering though.
@SammyEddie
@SammyEddie 5 жыл бұрын
mastersfan04 so DONT make straight, all copper connections? I was going to redo mine.
@brianwrynn3109
@brianwrynn3109 4 жыл бұрын
My Hot Water Heater has no expansion tank. It is "Indirect-fired", meaning it has no built-in burner but instead the heat source is hot water from the home heating boiler. I guess when the hot water heats and expands, some of the excess hot water flows back into the cold water supply, since there is no check valve to stop it. It is an Amtrol HWM-40 and 20 years old. Is this a problem that needs to be fixed?
@Freeeeeeeee27
@Freeeeeeeee27 4 жыл бұрын
I’m no expert but whether or not you have an indirect tank shouldn’t change anything. Those tanks have a coil(s) that take in the heated water from the boiler. Thermal expansion will always occur. You mentioned that you don’t have a check valve in your system so you most likely have an open water supply system rather than a closed system which would require an expansion tank. You mentioned your tank is 20 years old so I can’t imagine 20 years of thermal expansion beating up your tank. It’s always good to get validation from a professional (and I encourage it since you are concerned) but it most likely isn’t an issue.
@brianwrynn3109
@brianwrynn3109 4 жыл бұрын
@@Freeeeeeeee27 Thank you.
@cdyoung976
@cdyoung976 2 жыл бұрын
I'm guessing if there hasn't been any problems in 20 years, you already have your answer.
@frankcalvert5612
@frankcalvert5612 4 жыл бұрын
What in Florida?
@hjwang4477
@hjwang4477 4 жыл бұрын
the inspector said the tank needs to be supported. any idea how to secure it?
@ericbraunberger849
@ericbraunberger849 5 жыл бұрын
Did you use a torch to join the connections or does just the glue do it?
@PLUMBINGWITHTIM
@PLUMBINGWITHTIM 5 жыл бұрын
All copper solder.
@Honestandtruth007
@Honestandtruth007 5 ай бұрын
I didn't See When to put Proper air pressure in Expansion Tank 😮😊
@davedono5508
@davedono5508 2 жыл бұрын
You didnt charge the new expansion tank to the existing house water pressure. THAT IS A MUST !!!!
@kevinscanlon1823
@kevinscanlon1823 4 жыл бұрын
Where are the dielectric unions?
@AJCoReTV
@AJCoReTV 4 жыл бұрын
Sharkbite flex tubes work fine for me
@frankc.5430
@frankc.5430 2 жыл бұрын
Required in some areas like those prone to earthquakes, not in others. Check your local code before you start and you're good.
@puppetpatti
@puppetpatti 5 жыл бұрын
Why am I not getting notifications? Look at you! 1700 subs! You are killing it! Woot!
@PLUMBINGWITHTIM
@PLUMBINGWITHTIM 5 жыл бұрын
Hi miss Patti. Thank you so much!
@martywoodrow131
@martywoodrow131 4 жыл бұрын
It would have been great to replace that gate vale with a ball vale
@themonkeydrunken
@themonkeydrunken Жыл бұрын
Did you check the house's water pressure, and add air to the expansion tank's bladder to match it? I didn't see that in the video. Remember to read the instructions everybody
@rajeshgajjar3774
@rajeshgajjar3774 Жыл бұрын
Expansion Tank which Pipe Hot water or cold water ? The pressure will be creat steam in hot water so expansion tank must go hot water pipe. Please could you check again ?
@strongsadventures
@strongsadventures 5 жыл бұрын
I do have a question tank or tanklesss? Your thoughts
@PLUMBINGWITHTIM
@PLUMBINGWITHTIM 5 жыл бұрын
Thanks guys. That’s coming up soon on another video 😊
@voiceofraisin241
@voiceofraisin241 3 жыл бұрын
Since the water heater has a check valve on the inlet. What good does adding an expansion tank on the cold side do? Also, pink Teflon tape is recommended for fittings larger than 1/2”.
@kashaftasribatalmiahbialriyad
@kashaftasribatalmiahbialriyad Жыл бұрын
شرح رائع جدا ❤
@thefloridaplumber2631
@thefloridaplumber2631 5 жыл бұрын
I have never put a wrench on the fitting on the expansion tank, just hand tight like you said, never had an issue. I will add my .02 cents and say I would have put a wrench on the female adapter to hold it while threading the tank on. As always Tim great video!
@MrRemerick
@MrRemerick 2 жыл бұрын
Thank you, Brother.
@anthonyesparsen7776
@anthonyesparsen7776 6 ай бұрын
Is this guy an actual licensed plumber guy?
@kraftbuilt5245
@kraftbuilt5245 4 жыл бұрын
Along with explaining how to charge the expansion tank, I think it’s worth mentioning the minimum distance of 18 inches away from the hot water heater that the expansion tank needs to be. You are very close to that.
@stanpiezuch9922
@stanpiezuch9922 4 жыл бұрын
Can you elaborate on that "18 inches away" requirement and what is its purpose? Does it have to do with the heat from the flue pipe and the balloon part inside the expansion tank?
@mariosifuentes5994
@mariosifuentes5994 3 жыл бұрын
Never heard of that , are you thinking the minimum height of the vacuum breaker perhaps?
@survivalSC
@survivalSC 2 жыл бұрын
There is a code that says pex has to start 18inch from the water heater lines
@JosephGetchel
@JosephGetchel 3 жыл бұрын
Isn’t that expansion tank mounted upside down?
@PLUMBINGWITHTIM
@PLUMBINGWITHTIM 3 жыл бұрын
No
@pxxexxs
@pxxexxs Жыл бұрын
Technically it is. I had a discussion with a coworker about that fact today and we read the manual from the manufacturer and the say to install with threading face up.
@Nokout626
@Nokout626 2 жыл бұрын
Just a question... why type M copper... and not L...
@mrlukenukem88
@mrlukenukem88 2 жыл бұрын
Copper fip should be brass coming off the top of the tank.
@Unkdrefinest
@Unkdrefinest Жыл бұрын
It's code that you don't turn the tank upside-down through test it last longer having bleeder facing down. Yeah I know they have been doing it this way for over a hundred years, but a hundred years they all was backwards. You also supposed to check the water pressure to match the tank. Thanks Tim
@JasonVladimir
@JasonVladimir 5 жыл бұрын
Good show, thanks for sharing!
@donaldblank8873
@donaldblank8873 Жыл бұрын
The pressure in the tank needs to be equal to the incoming pressure for it to be functional.
Training Series: Expansion Tank Installation
8:55
Plumbing Express
Рет қаралды 80 М.
Expansion Tank Support - Proper Installation for Expansion Tanks
6:44
To Brawl AND BEYOND!
00:51
Brawl Stars
Рет қаралды 17 МЛН
It works #beatbox #tiktok
00:34
BeatboxJCOP
Рет қаралды 37 МЛН
Beat Ronaldo, Win $1,000,000
22:45
MrBeast
Рет қаралды 158 МЛН
Do I need a thermal expansion tank? - Let's do an experiment!
31:45
Smedley Plumbing
Рет қаралды 595 М.
30 Minute Secret Makes Your Water Heater Last Decades
13:03
LRN2DIY
Рет қаралды 2,4 МЛН
How to replace a hot water expansion tank
9:10
Everyday Journey
Рет қаралды 250 М.
10 Reasons Why You'd FAIL a Plumbing Inspection! | GOT2LEARN
7:36
How to Check Your Home's Water Pressure
4:33
Know How Now
Рет қаралды 228 М.
6 SHARKBITE Mistakes NOT To Make! | GOT2LEARN
4:16
Got2Learn
Рет қаралды 2,9 МЛН
What water heater should I buy? - Pro Grade vs. Box Store
1:02:14
Smedley Plumbing
Рет қаралды 541 М.
How to Replace a Gas Water Heater
48:01
SharkBite Plumbing
Рет қаралды 31 М.