HOW TO INSTALL A THERMAL EXPENSION TANK ON WATER HEATER

  Рет қаралды 174,247

PLUMBING WITH TIM

PLUMBING WITH TIM

Күн бұрын

Join me today as i bring a water heater up to code and show you how to install a thermal expansion tank!

Пікірлер: 292
@avag1334
@avag1334 4 жыл бұрын
Don't you need to check the air pressure in the tank to match the water pressure coming into your house?
@mikemaggs3273
@mikemaggs3273 2 жыл бұрын
Wondering the same...
@Nokout626
@Nokout626 2 жыл бұрын
You definitely have to..
@JohnRidersoldoutforjesus
@JohnRidersoldoutforjesus Жыл бұрын
Yes
@Runflatred
@Runflatred Жыл бұрын
Of course.
@chadpayne2472
@chadpayne2472 Жыл бұрын
How do you do that ?
@barryrosenthal7337
@barryrosenthal7337 4 жыл бұрын
didn't ream the copper pipe after he cut it, didn't change that old shut off valve with a new better ball valve, didn't test water pressure to make sure the expansion tank matched with air pressure.
@wcsd9577
@wcsd9577 3 жыл бұрын
and no dielectric unions, and used type M copper
@chrispinette8303
@chrispinette8303 3 жыл бұрын
They are dielectric nipples coming out of heater
@forextrinitrader
@forextrinitrader 3 жыл бұрын
@@chrispinette8303 do Rheem water heaters use dielectric nipples? I installing a AO Smith and the manufacturer says dielectric unions are required.
@forextrinitrader
@forextrinitrader 3 жыл бұрын
He probably did it off camera, it hard to video everything thing when on a actual job.
@pipingdogtooth
@pipingdogtooth 3 жыл бұрын
@@wcsd9577 How can you tell it's not type L or K?
@5tr41ghtGuy
@5tr41ghtGuy 3 жыл бұрын
Just what I needed to see today to get a new heater installed. Thanks so much for posting!
@timc1341
@timc1341 2 жыл бұрын
Great vid Tim Expansion tanks are not required by code in florida unless the house is a "closed system" i.e. some sort of check valve or backflow preventer is in place inhibiting the expansion of the hot water back into the distribution system.
@homesteadhaven2010
@homesteadhaven2010 3 ай бұрын
Not required in Southern Mississippi..
@Honestandtruth007
@Honestandtruth007 2 ай бұрын
Just Subscribed for your Expertise 👍👍
@adolfomares23
@adolfomares23 8 ай бұрын
Whi didnt u use a union? With another nipple going to the water heater? I think it'll look cleaner...
@jgg204
@jgg204 4 жыл бұрын
The water heater will fail well before 30+ year rated sharkbite ever will. And when the water heater fails, you just replace the sharkbite valve flex lines with it like you would a dishwasher or a washing machine. In and out replacement in less than 30 mins
@josem2468
@josem2468 3 жыл бұрын
You hire a hack if they use Sharkbites. Only for homeowner use.
@jgg204
@jgg204 3 жыл бұрын
@@josem2468 and this is a home, you moron
@garygray4664
@garygray4664 2 жыл бұрын
Sharkbites are fine. I personally wouldn't use them right at a hot water heater but about 16-18 inches away would be better.
@grow8094
@grow8094 2 жыл бұрын
I I am a plumber never use shark bites There’s way better stuff to use I agree with the guy make the video you don’t use shark bites If the homeowner wants to use one that’s his choice but if you’re paying someone to do a job they should do it right
@jgg204
@jgg204 2 жыл бұрын
@@garygray4664 they are rated for 12" away from tank nipple
@fish4food0071
@fish4food0071 Жыл бұрын
I call b.s. on the shark bites. They are built to last as long as your hot water heater and in most cases outlive a soldier joint. I have done home repairs and remodels. I have been called to dozens of pipe leaks that were failed soldier joints and only one leaking shark bite and it leaked due to pipe not cut true and or deburred. And you check your incoming pressure before you install your expansion tank so you can pressurize it to match.
@Grizzleback07
@Grizzleback07 5 ай бұрын
I have them on several connections that are in the open and not a single leak. You HAVE to debur the pipe and cut it straight like you said in order for them to fully seat and make a good connection. These guys are stuck in the fittings of the 80's when they were not as good.
@Travis-bu6yo
@Travis-bu6yo Жыл бұрын
Did you not ream the pipe after you cut it?
@johnblack2427
@johnblack2427 5 жыл бұрын
Good video how though it was more about the copper than the actual tank. Did you add air to the tank, and what is the pressure in the tank installed in relation to the pressure in the plumbing system?
@nikkogarcia7104
@nikkogarcia7104 5 жыл бұрын
You didn't charge up that expansion tank with air matching the pressure to the incoming water supply. That tank on there isnt doing anything useful without a proper charge.
@PLUMBINGWITHTIM
@PLUMBINGWITHTIM 5 жыл бұрын
I’m glad you guys mentioned this as I realize that I left this step out. I will be doing a follow up video about this critical step. Thanks for watching!
@darienlandry3244
@darienlandry3244 4 жыл бұрын
Nikko Garcia those typically come precharged just saying
@coachmattc
@coachmattc 4 жыл бұрын
@@darienlandry3244 Not enough. Needs to match the system pressure.
@brandonmunsin9310
@brandonmunsin9310 3 жыл бұрын
lil tip, they usually always come pre charged @20lbs.. an easy way to figure out what to charge up too, pressure test the house , thtl be your # then use air compressor. never charge passed 80lbs. usually 50 is where it’s at.. yes most people don’t charge them, makes it pointless to have if not charged... anyways good vid! keep it up man, stay positive! im an commercial/industrial plumber. plumb everyday on big systems , an no matter what you do somebody will always have something to say lol everyone thinks they know it all, an most likely really don’t know shit ..wish people were more positive
@pipingdogtooth
@pipingdogtooth 3 жыл бұрын
@@PLUMBINGWITHTIM Can you provide a link to the update?
@stevie2132
@stevie2132 4 жыл бұрын
Not legal in California..you need flex supply lines just in case of a earth quake.wish we can do it that way
@blueg3027
@blueg3027 3 жыл бұрын
Has California ever heard of earthquake straps?
@drdez
@drdez 3 жыл бұрын
@@blueg3027 I thought the straps keep the tank from tipping over not the pipes of it breaking because of the flexing of the pipes/house.
@PetePuebla
@PetePuebla 3 жыл бұрын
In my opinion I think you're right about securing it snugly. I don't think you have to use a wrench. You just need a good seal.
@keithcastleberry3993
@keithcastleberry3993 4 жыл бұрын
Dont use shark bites but let's screw copper fittings to galvanized pipe to promote electrolysis. Nice.
@chrispinette8303
@chrispinette8303 3 жыл бұрын
They are dielectric nipples with plastic cores
@pxxexxs
@pxxexxs Жыл бұрын
He is using dielectric nipples he talks about the plastic in them.
@pj3p488
@pj3p488 4 жыл бұрын
Sharkbites in earthquake zones, ok. KZbinr, DIY, and lazy plumbers love them. How often have I gone back to their work and removed the flexes because they went bad and started leaving black goo in their hot water? Quite often. Heater tip, if it has a plastic drain valve it is a crap heater.
@josem2468
@josem2468 3 жыл бұрын
How true. Needs a full port drain valve.
@puppetpatti
@puppetpatti 5 жыл бұрын
Why am I not getting notifications? Look at you! 1700 subs! You are killing it! Woot!
@PLUMBINGWITHTIM
@PLUMBINGWITHTIM 5 жыл бұрын
Hi miss Patti. Thank you so much!
@davedono5508
@davedono5508 2 жыл бұрын
You didnt charge the new expansion tank to the existing house water pressure. THAT IS A MUST !!!!
@beaunhead
@beaunhead 8 ай бұрын
Wish you would've shown the soldering... Great video, good detail and explanation
@BillAnon
@BillAnon 11 ай бұрын
How do you tell what size expansion tank you need?
@eduarm1824
@eduarm1824 3 жыл бұрын
my name is Edwin from Honduras and I love you body. nice job !!!!!
@rickjames6948
@rickjames6948 10 ай бұрын
Check house water pressure. Adjust thermal expansion tank pressure accordingly. Do this with the hot water tank with zero pressure inside it. Don't want water pressure pressing into the thermal expansion tank fudging the thermal tank pressure.
@neogeo8267
@neogeo8267 2 жыл бұрын
No dielectric unions?
@johnhuggins5021
@johnhuggins5021 3 жыл бұрын
I noticed you did not install a strap to the expansion tank to support it using the surrounding the wall. Has it been your experience that doing this step is not really necessary even if the tank fills with water, empties, fills, empties, etc. several times over its lifetime? Oh, and does it matter whether or not the schrader valve end is at the top of the tank or at the bottom? Or that depend on the manufacturer's recommendation for the install? Thanks for any feedback.
@rajeshgajjar3774
@rajeshgajjar3774 Жыл бұрын
Expansion Tank which Pipe Hot water or cold water ? The pressure will be creat steam in hot water so expansion tank must go hot water pipe. Please could you check again ?
@saranjesse23
@saranjesse23 3 жыл бұрын
Excellent job explaining the steps and why you’re doing what you’re doing! Thanks.
@themonkeydrunken
@themonkeydrunken Жыл бұрын
Did you check the house's water pressure, and add air to the expansion tank's bladder to match it? I didn't see that in the video. Remember to read the instructions everybody
@MonkeyManMechanicals
@MonkeyManMechanicals 5 жыл бұрын
no dielectric unions or unions at all???
@stevenmott4158
@stevenmott4158 4 жыл бұрын
Christopher Segar why would he need a dielectric Union he is using all copper not mixing metals
@darienlandry3244
@darienlandry3244 4 жыл бұрын
Steven R Mott he is mixing, you cannot adapt copper to galvanized without having brass in between it, flexes or dielectric unions, Electrolysis is real my friend, and Code
@stevenmott4158
@stevenmott4158 4 жыл бұрын
The nipples that come with the water heater are not galvanized
@stevenmott4158
@stevenmott4158 4 жыл бұрын
Heat trap nipples are already dielectric
@footlongburrito
@footlongburrito 4 жыл бұрын
Its not about being dielectric anymore it's still code to use unions, now someone will have to cut the copper pipe to do anything... what if he couldn't start the heater because of a issue and had to return the heater and get a new one? Now without unions you can't without cutting pipe. This isn't code
@diezak2990
@diezak2990 2 жыл бұрын
Should have used dielectric union to go from galvanized to coppers I'm an HV AC installer replacing water heater and furnace for realtor selling house I replaced water heater today in a tight spot old house with galvanized fittings and I didn't like came out because I had to install the expansion tank before the shut-off should I change it
@RichRich007
@RichRich007 2 жыл бұрын
how can you put a wrench on there to "snug it all the way up" when its soldered in place?
@williammorris3303
@williammorris3303 2 жыл бұрын
Can the expansion tank be to far away? I did a hot water tank , electric 40g tank , closed water system so I put in a 1.5g expansion tank, pumped it in the same way I always do. T&p valve blew as soon as the tank came up to temp. I thought how crazy that a new tank had a faulty valve, so I changed it. But it still blew the valve.
@timrobinson9897
@timrobinson9897 5 жыл бұрын
Tim Job isn’t done quite yet. You need to check the water pressure from the city coming in. Easy to do just put a pressure gauge at a hose spigot preferably near where the water comes in. Take that pressure and use a small air hand air pump like a bicycle pump to pump up the expansion tank. On the expansion tank is an air valve it looks just like the one on your car tire. The tank needs to be inflated to the same pressure as the city. Otherwise the expansion tank is just a decoration and provides no benefit.
@PLUMBINGWITHTIM
@PLUMBINGWITHTIM 5 жыл бұрын
Very good point my friend. Thanks for sharing that. Much appreciated.
@darienlandry3244
@darienlandry3244 4 жыл бұрын
Tim Robinson those typically come pre-charged
@kevinh9262
@kevinh9262 Жыл бұрын
@@darienlandry3244 But you need to match the house water pressure. The tank may only be charged to 20 or 40 PSI from the factory. I just installed one at a house that had 60 PSI. Had to pressurize the tank. If you do not balance it, it will not work properly.
@davew657
@davew657 11 ай бұрын
The info I'm looking for is a bit more involved. For instance, if you check your pressure with a gauge, are you getting a true reading if the water heater just heated up and is pushing it's thermal expansion back towards your gauge? He turned off the breaker but that did not cool off the water (in water heater) and thus, did not stop the back pressure of the thermal expansion. So, should you do this when water heater is cold, warm, or hot ? @@kevinh9262
@Nokout626
@Nokout626 2 жыл бұрын
Just a question... why type M copper... and not L...
@desertcamel3573
@desertcamel3573 Жыл бұрын
where do the expansion tank go hot or cold side? if on hot side what's happens?
@kevinscanlon1823
@kevinscanlon1823 3 жыл бұрын
Where are the dielectric unions?
@Honestandtruth007
@Honestandtruth007 2 ай бұрын
I didn't See When to put Proper air pressure in Expansion Tank 😮😊
@thefloridaplumber2631
@thefloridaplumber2631 5 жыл бұрын
I have never put a wrench on the fitting on the expansion tank, just hand tight like you said, never had an issue. I will add my .02 cents and say I would have put a wrench on the female adapter to hold it while threading the tank on. As always Tim great video!
@LogginzLyfe
@LogginzLyfe 2 жыл бұрын
I replaced my expansion tank today and now I have very little pressure and hot water. Any ideas what’s wrong? I didn’t think the tank had anything to do with that. It was working fine before the replacement.
@martywoodrow131
@martywoodrow131 4 жыл бұрын
It would have been great to replace that gate vale with a ball vale
@kawaiibtslover1012
@kawaiibtslover1012 4 жыл бұрын
No hammer arrestors required?
@winstontaylor4364
@winstontaylor4364 Жыл бұрын
I think you missed a few steps on the way, you never checked water pressure to set air pressure for the expansion tank neither did you put an isolation valve on the hot water side to prevent building drain down if repairs need to be made neither did you install a union on either line to facilitate tank replacement
@edwardkiker3629
@edwardkiker3629 4 жыл бұрын
Didn't adjust air pressure to meet water pressure! Wasted you time and customers money. Come on man. You a plumber? Do it correctly or don't do it.
@PLUMBINGWITHTIM
@PLUMBINGWITHTIM 4 жыл бұрын
Thanks for watching Actually I did just forgot to add to video I did a follow up video on just that if you go back on my videos you’ll see
@smidjee1225
@smidjee1225 5 жыл бұрын
Thanks for the vid and info! What size expansion tank do you recommend for a 50gallon water heater? Or does it really matter?
@jinpark5324
@jinpark5324 4 жыл бұрын
Smidjee it depends on 3 factors:1 size of water heater 2 your household water pressure 3 water heater temperature setting. Referring to the following doc page 2 figure 1 to find the right size of expansion tank you need. www.amtrol.com/wp-content/uploads/2019/02/9015-942-01_19-Thermal-Expansion-Tank-IO.pdf
@garyteague4480
@garyteague4480 4 жыл бұрын
I would only ask why you didn’t put a Union in the line so when that heater is replaced it would make it simpler
@drummersanonymous
@drummersanonymous 4 жыл бұрын
I thought you were about to judo chop the camera when you were cutting that copper pipe. Nice video. 👌🏼
@buck3093
@buck3093 5 жыл бұрын
Shouldn’t there be a couple Dielectric Unions on there? (Going directly from copper to galvanized)
@PLUMBINGWITHTIM
@PLUMBINGWITHTIM 5 жыл бұрын
Good question. Back in the day when water heaters had galvanized nipples These days they are made from a different alloy so it’s no longer required
@buck3093
@buck3093 5 жыл бұрын
PLUMBING WITH TIM That’s good to know! Thanks :-)
@eallevato
@eallevato Жыл бұрын
I am reading the installation instructions for a BACKSTOP expansion tank and they caution you to install the tank vertically with the air side in the downward position ONLY. Why is your installation backwards?
@RoyBaty
@RoyBaty Жыл бұрын
Old school. Thanks for showing how it's been done for 100 years. Too many videos show the new compression tools that most of us can't afford or the shark bite pieces that are expensive. This is cheaper and with a few plumbing tools and practice most of us can master this method. One thing, show us your soldering. Some people don't realize you need to heat the elbow, not the opening. When the entire fitting reaches the correct temperature the solder will be drawn all the way in.
@amarinayat8879
@amarinayat8879 4 жыл бұрын
Excellent video, thank you! I have a couple of questions.... since I am planning installation in two locations in attic, one with very limited space.... 1. How far from the inlet side can an expansion tank be installed. Say, would it serve its purpose if I ran a 10 foot pipe from the inlet and installed the expansion tank sideways, or upside down? Shouldn't the air valve on the tank be easily accessible for maintaining pressure? 2. How do you size an expansion tank for a 40 gal vs 75 gal water heater? 3. How do you feel about using pex instead of copper? Thanks in advance for your help.
@Resq28
@Resq28 Жыл бұрын
Great questions, I wish he would get back to some of these questions because I need the answers as well. Thank you for asking them.
@polarlab113
@polarlab113 3 жыл бұрын
Why you guys never read instructions?it says right in there to mount vertically with the schrader valve on the bottom.upside down leaves no head pressure and the tank will fail prematurely.as well you didn’t check the house pressure in order to properly adjust the expansion tank BEFORE it is installed.check the website it shows and explains very simply
@herrickinman9303
@herrickinman9303 4 жыл бұрын
Metal pipes soldered to the water heater would not pass inspection in California. California requires flexible water hoses and a flexible gas hose in order to minimize the chance of breakage during an earthquake. Sharkbite connections are allowed in California. You'll find Sharkbite hoses and connectors at Home Depot stores and Lowes stores throughout the state.
@dmdx86
@dmdx86 Жыл бұрын
Sharkbites are allowed pretty much everywhere. Plumbers just don’t like them for various and often specious reasons.
@fish4food0071
@fish4food0071 Жыл бұрын
They do not like shark bites because it shorten there time on job that can be charged. So the don’t make as much money!!
@WinnTeam
@WinnTeam Жыл бұрын
@@fish4food0071 I don't like them because as an Engineer - i see them as less reliable than other options, my preferred is still copper pipes sweated together. Nothing to do with a plumber making more money - everything to do with failure points.
@kevinh9262
@kevinh9262 Жыл бұрын
@@WinnTeam I'm an engineer and I have used them many times. They work great.
@tick_go5989
@tick_go5989 Жыл бұрын
I recently experience corrosion rust build up where copper connection to the steel nipple on my water heater tank. With some quick research online turns out my viewers are correct about dissimilar metal reaction causing the rust. Sharkbite flexible possibly a better option to prevent corrosion!
@sonshenshomestead7668
@sonshenshomestead7668 Жыл бұрын
Is it necessary to prep the water expansion tank with pressurized air first?
@obie224
@obie224 5 ай бұрын
Wtf is the point of installing an expansion tank if you never check or match the water pressure ?? And that just the big mistake, he made a dozen other small ones. This guy is DEFINETLY not someone to learn from, unless you're trying to learn how NOT to do a good job.
@AJCoReTV
@AJCoReTV 4 жыл бұрын
Sharkbite flex tubes work fine for me
@frankc.5430
@frankc.5430 2 жыл бұрын
Required in some areas like those prone to earthquakes, not in others. Check your local code before you start and you're good.
@strongsadventures
@strongsadventures 5 жыл бұрын
Thank you for taking your time to show this Tim. It is hard enough to do the Job fast and most important the right way so i will say this thank you for sharing how to do this. Ain't gonna be no leaks if you did it.
@davidmaddox6829
@davidmaddox6829 4 жыл бұрын
Don't you need to confirm the pressure of the new tank before installing it?
@PLUMBINGWITHTIM
@PLUMBINGWITHTIM 4 жыл бұрын
Yes indeed and I made a video shortly after this one explaining that. Thanks for watching!
@jayham1970
@jayham1970 2 жыл бұрын
If water departments had not for [stupid reasons] started putting check valves into systems (absolutely was not needed), expansion tanks would not be needed. The reasons given for closing off systems was absolutely asinine.
@jamesrecknor6752
@jamesrecknor6752 Жыл бұрын
Good teaching ability
@alexramirez-hd8le
@alexramirez-hd8le Жыл бұрын
No dielectric unions electrolysis bud
@pepelepew158
@pepelepew158 4 жыл бұрын
Thank you.!!!!! This helped me out a lot. Awesome video again ty so much for taking the time and explaining it step by step.
@SSMLivingPictures
@SSMLivingPictures Жыл бұрын
It seems theres an unfortunate trend in literally no one covering the pressure matching aspect. Are there no competent plumbers on YT?
@MrRemerick
@MrRemerick 2 жыл бұрын
Thank you, Brother.
@Billfold66
@Billfold66 8 ай бұрын
all wrong! you didn't install dielectric unions at the water heater nipple to transition from the 2 different materials to prevent corrosion. Nice try.
@joecarini9958
@joecarini9958 Жыл бұрын
Very informative..however, not sure if the music background was necessary, a bit distracting.
@tedtedness184
@tedtedness184 2 жыл бұрын
You forgot to tell how to regulate the backside tank pressure and check it yearly. You need to add this. The video is not complete.
@nestorgonzales2595
@nestorgonzales2595 2 жыл бұрын
So you don't check depression or the water supposed to be 75 or 80 and the other thing that I didn't see is you thank it sopust to be haf way fil whit water
@anthonyesparsen7776
@anthonyesparsen7776 3 ай бұрын
I used spa wrench to tighten my expansion tank once it twisted all my copper pipe system
@donaldblank8873
@donaldblank8873 11 ай бұрын
The pressure in the tank needs to be equal to the incoming pressure for it to be functional.
@nadeemmian7750
@nadeemmian7750 3 ай бұрын
wondering why you install expansion tank on the cold line. should it not be on the hot water line ?
@anthonyesparsen7776
@anthonyesparsen7776 3 ай бұрын
I have never seen anyone put two types of sealing tape and that other moist liquid type on a fitting
@MyGodzilla33
@MyGodzilla33 Жыл бұрын
How come you didn't mention put the water pressor air in to expantion tank before put them on?
@jonathantrella832
@jonathantrella832 5 ай бұрын
What the meth? They call anyone a plumber down in florida 🤣
@jimmywilliams6023
@jimmywilliams6023 5 жыл бұрын
What’s with the music. Are at a club?
@PLUMBINGWITHTIM
@PLUMBINGWITHTIM 5 жыл бұрын
Lol thanks for watching!
@markehooker
@markehooker 3 жыл бұрын
I've watched a few videos and all the other plumbers checked the water pressure on the outside faucet and charged the expansion tank to the same pressure. This plumber did not?
@PLUMBINGWITHTIM
@PLUMBINGWITHTIM 3 жыл бұрын
If you look through my videos I made a follow up video on just that. Thanks for watching
@anthonyesparsen7776
@anthonyesparsen7776 3 ай бұрын
Oh no electrical water heater not good, gas is less expensive.
@donaldblank8873
@donaldblank8873 11 ай бұрын
You did not pressurize the tank to the incoming water pressure,
@ronniepemberton1942
@ronniepemberton1942 Жыл бұрын
Why is an expansion tank needed I have never seen one at any house I have ever lived in and I'm 67
@anthonyesparsen7776
@anthonyesparsen7776 3 ай бұрын
Is this guy an actual licensed plumber guy?
@Homepros888
@Homepros888 5 жыл бұрын
Is that type M copper you installed on the cold side (red mark) usually type L is suggested for water (blue). Type M is only for heating
@mastersfan04
@mastersfan04 5 жыл бұрын
Every service plumber worth his salt uses L pipe
@darienlandry3244
@darienlandry3244 4 жыл бұрын
You can use M if you want, just not underground
@SammyEddie
@SammyEddie 4 жыл бұрын
mastersfan04 is this video for professionals? Doubt it since he shows how to use Teflon tape. Any help is appreciated. I thought copper pipe was copper pipe.
@mastersfan04
@mastersfan04 4 жыл бұрын
@@SammyEddie this video is for DIY people, but it's bad advice. Water heaters should be connected with flex lines or unions , and the thermal expansion tank should have air pumped in to match the static water pressure. There are good videos of that. The video is correct about soldering though.
@SammyEddie
@SammyEddie 4 жыл бұрын
mastersfan04 so DONT make straight, all copper connections? I was going to redo mine.
@jackjones1727
@jackjones1727 3 жыл бұрын
To replace the heater, you have to unsweat the joints. Is that normal?
@christobalalvarez394
@christobalalvarez394 4 жыл бұрын
The copper pipe that he's installing on the water heater to supply the house looks like type N and not type L. Look Like Condensation Pipe
@jimfrieday6831
@jimfrieday6831 3 жыл бұрын
Yes, Red ink is type M, Blue ink is type L
@garynall7899
@garynall7899 2 жыл бұрын
I stopped watching a few seconds in when he called it a “hot water heater.”
@fredost1504
@fredost1504 9 ай бұрын
Sharkbites are the best. They just hurt your business is all. The homeowner can plumb, themselves.
@estuardoerazo9998
@estuardoerazo9998 Жыл бұрын
Isn’t a vacuum breaker code in Florida?
@Munsad1919
@Munsad1919 Жыл бұрын
remove background music.....!!!!!!🤯
@jeffcoleman5160
@jeffcoleman5160 Жыл бұрын
Should replace those valves anyway
@BOSS_805
@BOSS_805 7 ай бұрын
Why are you not using di electric unions?
@brianrobertson1211
@brianrobertson1211 3 жыл бұрын
Did you ream your pipe?
@mitxchellmitxchell6564
@mitxchellmitxchell6564 2 жыл бұрын
where are you located I'm in central Florida and needing of an awesome plumber like yourself.
@PLUMBINGWITHTIM
@PLUMBINGWITHTIM 2 жыл бұрын
I moved to western Kentucky
@markschwartz5684
@markschwartz5684 Жыл бұрын
where is the unions for future change out..
@Real_Rob_Reels
@Real_Rob_Reels 10 ай бұрын
Did you debur the inside of the 6" pipe you cut so you don't get turbulence? Also, you never took the house water pressure and adjust your expansion tank to that pressure. Always a good rule of thumb to check pressures before the install. Most 2.5 gallon Exp. Tanks come at 50 psi but it's shooting in the dark until you get some hard data.
@Scorpiomaj27889
@Scorpiomaj27889 5 жыл бұрын
Hello, any specific reason you don't want sharkbites? Are they not technically up to code?
@darienlandry3244
@darienlandry3244 4 жыл бұрын
There a hack job
@dmdx86
@dmdx86 Жыл бұрын
Sharkbites allow DIYers and handymen to do plumbing jobs that normally you’d used to call a licensed plumber for. Sharkbites work and last if you follow instructions. Problem is unskilled people often don’t follow instructions (don’t deburr their copper and/or don’t insert the fitting to full depth) and you end up with leaks and they get a bad rep as a result.
@Monkeymanxxl
@Monkeymanxxl 2 жыл бұрын
What state are you in? I don’t think this will pass inspection in California but I am not sure
@PLUMBINGWITHTIM
@PLUMBINGWITHTIM 2 жыл бұрын
Florida
@Monkeymanxxl
@Monkeymanxxl 2 жыл бұрын
Thank you for your quick response, nice work looks very clean. After my comment I watch the video to the end and heard you say Florida, California is a pain in the ass
@carlthornton3076
@carlthornton3076 4 жыл бұрын
Very Good!!!!
@chris2884
@chris2884 Жыл бұрын
Nothing wrong with shark bites
@actury6
@actury6 3 жыл бұрын
It's wrong what you did You can't put a copper on metal You need the brass between
@tty3146
@tty3146 2 жыл бұрын
I have 2 heaters and expansion tank for each. one has pressure 55 psi and other has 75 psi. system pressure is 60 psi. Recently I am getting warm water from cold faucet. I changed tub cartridge but still getting warm water. What can be the issue? Faulty heat trap?
@kraftbuilt5245
@kraftbuilt5245 4 жыл бұрын
Along with explaining how to charge the expansion tank, I think it’s worth mentioning the minimum distance of 18 inches away from the hot water heater that the expansion tank needs to be. You are very close to that.
@stanpiezuch9922
@stanpiezuch9922 4 жыл бұрын
Can you elaborate on that "18 inches away" requirement and what is its purpose? Does it have to do with the heat from the flue pipe and the balloon part inside the expansion tank?
@mariosifuentes5994
@mariosifuentes5994 2 жыл бұрын
Never heard of that , are you thinking the minimum height of the vacuum breaker perhaps?
@survivalSC
@survivalSC 2 жыл бұрын
There is a code that says pex has to start 18inch from the water heater lines
@tommyfryman2688
@tommyfryman2688 3 жыл бұрын
Only thing I do differently I use dialectic union on the water heater
@joroland
@joroland 3 жыл бұрын
and Tim kept stressing 'this is Florida code'. Maybe differing metals don't promote corrosion in Florida (not).
@ambatson8897
@ambatson8897 3 жыл бұрын
I was about to ask this. I've only done commercial so we always used dialetric unions.
@chrispinette8303
@chrispinette8303 3 жыл бұрын
The nipples are dielectric
@tommyfryman2688
@tommyfryman2688 3 жыл бұрын
@@chrispinette8303 you don't know what you're talking about
@davs.1672
@davs.1672 3 жыл бұрын
@@ambatson8897 Those are dielectric nipples listen he told you not to get them hot as they had plastic inside them nipples
@onemorething100
@onemorething100 4 жыл бұрын
Hi Tim. Hopefully you can help me. I've had issues with high pressure in my home. At first I tried to adjust the Pressure regulator but soon realized it was not working. So I replaced it. I set the pressure at 60 and put a gauge on overnight but I'm still getting high readings. It seems to coincide with the HWT firing up. I don't have an expansion tank installed. Can thermal Expansion cause high pressure through out plumbing? My Neighbor said the expansion would only occur in the HWT not the home plumbing and an Expansion tank would not lower the pressure. I have a hard time believing the regulator is bad. any thoughts? Thank You
@matthewmusselman373
@matthewmusselman373 4 жыл бұрын
The rise in pressure starts at the water heater from thermal expansion. But without a place for the pressure to go it passes through the water heater and pressurizes the cold water line as well. They are one common water system unless they are separated by check valves. The expansion tank could help. The pressure surge could be caused by something else also. Quick acting valves like the ones used in irrigation or at your washer machine can cause a water hammer that may give you a high pressure reading.
@onemorething100
@onemorething100 4 жыл бұрын
@@matthewmusselman373 Thanks Man. A few weeks ago Installed A pressure tank and that seemed to correct the problem.
@jeffreyplumber1975
@jeffreyplumber1975 3 жыл бұрын
THERMAL EXPANSION install tank and call me in the morning!
@kashaftasribatalmiahbialriyad
@kashaftasribatalmiahbialriyad 9 ай бұрын
شرح رائع جدا ❤
Water Heater and Expansion Tank Maintenence
7:28
The Handyguys
Рет қаралды 626 М.
Officer Rabbit is so bad. He made Luffy deaf. #funny #supersiblings #comedy
00:18
Funny superhero siblings
Рет қаралды 14 МЛН
Как мы играем в игры 😂
00:20
МЯТНАЯ ФАНТА
Рет қаралды 3,3 МЛН
А ВЫ ЛЮБИТЕ ШКОЛУ?? #shorts
00:20
Паша Осадчий
Рет қаралды 9 МЛН
Do I need a thermal expansion tank? - Let's do an experiment!
31:45
Smedley Plumbing
Рет қаралды 553 М.
Installing an Expansion Tank on a Waterheater
19:42
Rough Riders
Рет қаралды 22 М.
Expansion Tank Support - Proper Installation for Expansion Tanks
6:44
Training Series: Expansion Tank Installation
8:55
Plumbing Express
Рет қаралды 75 М.
How To Replace Your Electric Hot Water Heater | Full Install DIY
29:30
30 Minute Secret Makes Your Water Heater Last Decades
13:03
LRN2DIY
Рет қаралды 2,2 МЛН
#1 PEX Plumbing Mistake You Don't Want to Make (A vs B)
6:14
Silver Cymbal
Рет қаралды 3,1 МЛН
Officer Rabbit is so bad. He made Luffy deaf. #funny #supersiblings #comedy
00:18
Funny superhero siblings
Рет қаралды 14 МЛН