How to install an A/C UV Light Kit | EASY Step by Step

  Рет қаралды 24,347

Deanin' It Yourself

Deanin' It Yourself

Күн бұрын

Пікірлер: 47
@danpurnell802
@danpurnell802 9 ай бұрын
A Very Big Thank you - enjoyed the step-by-step Installation- I'm installing 2 lights, first with-in the Acorn & the 2nd in the return. I up the breaker from 35 to 50 and using 2 Transformer for the UV Balesters.
@jnava5567
@jnava5567 8 ай бұрын
Thanks for the great step by step video, but I have one question. In the secondary wires, is there a hot or it can be connected to any wires on the light fixture wires.
@derrickgray3114
@derrickgray3114 5 ай бұрын
Installed one at my customers home with similar setup as you had to remove because the ac filter lights up blue from the reflection off coil
@josephli7260
@josephli7260 4 ай бұрын
Im trying to install 3 lights into my unit. Do you need a separate transformer for each light?
@DeaninItYourself
@DeaninItYourself 4 ай бұрын
no
@aho9664
@aho9664 9 ай бұрын
Good video bro i have to of them in my AC. One in the air handler and one in the duck work
@DeaninItYourself
@DeaninItYourself 9 ай бұрын
Nice 👍
@miguelangelgonzalezcanas7177
@miguelangelgonzalezcanas7177 2 ай бұрын
did you use 2 transformers?
@miguelangelgonzalezcanas7177
@miguelangelgonzalezcanas7177 2 ай бұрын
Hi, If you want 2 lights, one above and one below the coils? do you need 2 separate transformers, one for each light?
@DeaninItYourself
@DeaninItYourself 2 ай бұрын
One transformer should be good
@cameronharris2862
@cameronharris2862 2 ай бұрын
can I use the same 24v wires that go to my humidistat and splice? Or do I need to add another transformer? Thanks
@DeaninItYourself
@DeaninItYourself 2 ай бұрын
As long as there is not a big voltage drop you whould be fine. If not just add the transfomer
@bactran3714
@bactran3714 2 ай бұрын
By wiring the transformer directly to the power in, do you intend to let the UV light being ON all the times even when the thermostat sends the signal to turn off the system, is it correct? If so, will the UV light have a shorter life?
@DeaninItYourself
@DeaninItYourself 2 ай бұрын
yes that is correct
@jessikat6692
@jessikat6692 5 ай бұрын
My Carrier Unit is a 208/230. Which Wires do I use?
@DeaninItYourself
@DeaninItYourself 5 ай бұрын
Red and white. Use the one for 208
@jessikat6692
@jessikat6692 5 ай бұрын
@@DeaninItYourself Thank you.
@pukabouy1
@pukabouy1 2 ай бұрын
Recommend adding note (and product link) about UV safety glasses around these lights.
@DeaninItYourself
@DeaninItYourself Ай бұрын
👍
@DCINTEXAS
@DCINTEXAS 5 ай бұрын
I am thinking of installing an HVAC UV light inside my supply duct in front of the coil. However, my supply duct has some type of thick black insulation inside of it. I am concerned this insulation might degrade over time due to the UV light. Also, I was wondering if it's OK for hot air (when heater is running) to run while the UV lights are on. Thank you.
@DeaninItYourself
@DeaninItYourself 5 ай бұрын
Yes the hot air running is fine. The UV lights are designed for this. As far as the insulation goes , I am not sure about this.
@ApothercyCold
@ApothercyCold Ай бұрын
Seems like you'd be better off wiring it to power on with the unit. Or, do it this way but utilize something like a Shelly to have it power on (via Home Assistant or something) only when running.
@DeaninItYourself
@DeaninItYourself Ай бұрын
That could be an option as well
@dcs4555
@dcs4555 2 ай бұрын
now you have installed that at the back of the plenum. and the wire goes through a hole with no cable protection. jeez you seem very confident though, i agree on your intentions. just please let everyone else know this is not the best way to install it. i haven't even installed mine, but wanted to know how/why the magnet, and where. now i see how the supplier intended it to mount. and i don't have a metal duct, i have that sheetboard of insulation. so i'm still working it out. as always, just mho
@dcs4555
@dcs4555 2 ай бұрын
ok i guess that was premature. now i think this device just uses the magnet for a metal plenum. but the bracket has mounted studs, with thumb nuts (i hope that makes sense) for the actual BULB mount. and the magnet is for a metal plenum. i will probably use a metal square to sandwich on the fiberboard insulation. but the 24 transformer - i hope to not need. according to my hvac paperwork- i should be able to use the inside blower circuit. i may be wrong! lol but so far my plans are to go with the 24v common (denoted "C" wtf - online says blue/black/brown/purple) and cool stage 1 (yellow). so we'll see i guess. that should make it light up only when the indoor fan is running. but i did not look into the max current for the hvac 24v circuit. so that might be a prob. just mho
@Alexsjusa
@Alexsjusa 6 ай бұрын
Well what a surprise I’m looking into UV lights and if I should keep my UV light from my unit I’m about to replace. I remember you, Steven’s friend! How much are those bulbs. My AC company is saying they are about $400. How much is the entire system?
@DeaninItYourself
@DeaninItYourself 5 ай бұрын
you can get them on Amazon for around $100 or less
@Alexsjusa
@Alexsjusa 4 ай бұрын
@@DeaninItYourself they ‘threw in’ a new system for an extra hundred dollars. There are 2 lights so I’ll see how it goes
@antok86
@antok86 7 ай бұрын
What model air handler is that? Mine has 230v
@DeaninItYourself
@DeaninItYourself 7 ай бұрын
its a carrier
@antok86
@antok86 7 ай бұрын
@@DeaninItYourselfmy carrier unit has an existing 24v transformer can’t I just tap into that?
@neonnight34609
@neonnight34609 6 ай бұрын
​@@DeaninItYourselfI also have the same question. If my unit has 24 volts can I tap into that?
@EduardoFuentesLeal
@EduardoFuentesLeal 5 ай бұрын
230 use the 240v cable
@antok86
@antok86 3 ай бұрын
@@neonnight34609still tryna find this out my lf
@lindenjohnson5111
@lindenjohnson5111 6 ай бұрын
Thank you so very much
@DeaninItYourself
@DeaninItYourself 6 ай бұрын
You are so welcome
@clintgray1623
@clintgray1623 4 ай бұрын
Drill the hole bigger and screw it in from the front, lots easier access
@malcolden7788
@malcolden7788 2 ай бұрын
Also why is the magnet placed on the back wall instead of the front wall? Less wire exposed inside by placing it on the opposite side.
@ShotByNikoHD
@ShotByNikoHD 18 күн бұрын
I wouldn’t put it under the coil.
@DeaninItYourself
@DeaninItYourself 17 күн бұрын
why not
@ShotByNikoHD
@ShotByNikoHD 16 күн бұрын
@@DeaninItYourself does the sweat/condensation falling on it mess with it at all?
@disdatndaothaguy7436
@disdatndaothaguy7436 9 ай бұрын
Are you building your home into a smart home?
@DeaninItYourself
@DeaninItYourself 9 ай бұрын
Yes my house has a ton of smart features
How to Improve The Air You Breathe With UV Light
24:56
Dan Jiles
Рет қаралды 15 М.
7 Best HVAC UV Lights For Air Purification
7:25
Air Conditioner Lab
Рет қаралды 70 М.
ТЮРЕМЩИК В БОКСЕ! #shorts
00:58
HARD_MMA
Рет қаралды 2,7 МЛН
Accompanying my daughter to practice dance is so annoying #funny #cute#comedy
00:17
Funny daughter's daily life
Рет қаралды 22 МЛН
Симбу закрыли дома?! 🔒 #симба #симбочка #арти
00:41
Симбочка Пимпочка
Рет қаралды 5 МЛН
Installing a UV Light and Air Treatment System in an HVAC Unit! STEP BY STEP
8:41
Adding a UV Light to your HVAC system | McCoppin's Manual to Manliness
12:30
UV Light Installation
12:45
Jason Giannone
Рет қаралды 64 М.
HVAC Contractors Hate Me For Sharing This Secret
10:21
The DIY HVAC Guy
Рет қаралды 1 МЛН
ESSENTIAL Tools For Electricians And EV Installers
24:33
SOTA Electrical
Рет қаралды 9 М.
Ultra Violet Light Installation Start to Finish
8:46
David Jones
Рет қаралды 380 М.
How to Install Downlights With No Access Above | It is Possible!
20:39
The ONE AC Upgrade Every Homeowner Needs to Consider!
18:32
How To Home
Рет қаралды 540 М.