No video

How to install an Outdoor Hot Water Heater.

  Рет қаралды 133,356

DiyMovies SA

DiyMovies SA

Күн бұрын

A video that shows you how to install a hot water heater on the outside of your home.
Please like, subscribe and hit the little bell to get our new videos.
Installation by Outien Construction, Robertson.
***************************
DiyMovies SA was created by film maker Don Morris to give homeowners and those interested in d.i.y. projects information and templates to work from that will make any job much easier, save you a load of money as well as help you to achieve a great result.
If you find value in these videos please consider becoming a channel patron,.
Donate a few dollars for every video that I produce to support me as people used to support artists in the past.
The artists were able to work full-time on their masterpieces as they received money to support them every month from generous patrons.
Please go to this link to become a patron liberapay.com/...

Пікірлер: 92
@wafiqahcarelse9108
@wafiqahcarelse9108 4 жыл бұрын
My husband connected our geyser up following this video and it's been 2 months still going without problems thumbs up to the 2 plumber's in the video and I notice they from south Africa by they language lol great jobs
@howitsmade5865
@howitsmade5865 4 жыл бұрын
Thanks for letting us know Wafiqah. Yes, it was filmed in Robertson.
@salmaancarelse7443
@salmaancarelse7443 Жыл бұрын
I'm the (husband) I see my wife's comment it's been 2 years of the installation of my geyser and I followed every step of this video amazing insight of the procedures no one could believe when I said I did it myself my geyser burst over the weekend but luckily I was insured by outsurance but decided to take a cash claim and do it myself once again because over this 2 years I have installed 8 people geysers and done it brilliantly even if I have to say it myself, pipes was neatly secured to the wall layout was finished perfectly but know I'm looking forward to do mine again but this time I want to install solar panels but I do not think I'll do that myself I'll rather get a professional to do the installation on the solar panels. But after 2years still kept this video in my downloads. Thanks alot guys
@salmaancarelse7443
@salmaancarelse7443 Жыл бұрын
@@howitsmade5865 if you can provide me with contact details of your business because I would like to install solar panels to my geyser please
@tinashel.gadzikwa4358
@tinashel.gadzikwa4358 3 жыл бұрын
Good video. However it is important to note that when installing a geyser, there is need to balance the pressure on the cold water supply i.e. cold water for the rest of the house and for the geyser supply. To achieve this, cold water supply to the rest of the house must be connected after the pressure valve. So its pressure valve, tee junction (house cold water supply and geyser cold water supply) and straight valve Now if you do that you achieve a balanced water pressure on both cold and hot water. Thank you
@alexagyeimensah1316
@alexagyeimensah1316 3 жыл бұрын
Thanks Tinashe, I'm a plumber can I please have your contact My contact is 0786959211
@tinashel.gadzikwa4358
@tinashel.gadzikwa4358 3 жыл бұрын
@@alexagyeimensah1316 in which town are you
@alexagyeimensah1316
@alexagyeimensah1316 3 жыл бұрын
I'm in cape Town
@caiphus321
@caiphus321 2 жыл бұрын
Except there's no longer cold water supply to the rest of the house
@ShaielC
@ShaielC 2 жыл бұрын
The problem with this is if there is a problem with the geyser, there will be no water at all to the whole house
@tdyani
@tdyani 4 жыл бұрын
This is a good job, would’ve loved to hear about the power supply but great job by the guys.
@howitsmade5865
@howitsmade5865 4 жыл бұрын
Thanks Thembani, most appreciated.
@ethanalexanderpatience1994
@ethanalexanderpatience1994 Жыл бұрын
I'd like to say I was xtremely high and watched this video about ten times 🤣🤣 it really helped with my installation
@derickvilakazi2263
@derickvilakazi2263 4 ай бұрын
The best teacher❤❤❤❤❤❤❤❤❤
@jvandervyver
@jvandervyver 3 жыл бұрын
Why are the vacuum breakers being referred to as solar outlets? Also the anti-syphon loop is sitting lower than the top of the "water heater", it should stick out above.
@matto6195
@matto6195 2 жыл бұрын
Handy Andy trying to plumb
@adamokuhle9753
@adamokuhle9753 6 ай бұрын
Looking for this very same comment 😂
@Pyxe_ZA
@Pyxe_ZA 4 жыл бұрын
Very helpful and to the point. Some of these “how to” videos tend to spend 9/10 minutes talking a lot of nonsense and the actual video is just a minute long. Good job and thanks for sharing
@DiyMoviesSA
@DiyMoviesSA 4 жыл бұрын
Thanks Peter
@pietersmith1441
@pietersmith1441 3 жыл бұрын
well done for trying all plumbing systems need to be balance otherwise warranty will be avoided on all plumbing mixers
@matto6195
@matto6195 2 жыл бұрын
Those "solar outlets" are called vacuum breakers. They allow air into the system and play a role in preventing back siphonage. The anti siphon loop in this installation is too low, the horizontal run of the pipe should be higher then the top of the geyser. The cold water supply to the rest of the house seems to be absent... That would normally come after the PRV to ensure balanced pressure in the installation. Sheesh. Guys please call a plumber instead.
@njabulohonwana3838
@njabulohonwana3838 3 жыл бұрын
What a greatest content for DIY... just watched this vid and then subscribe to the channel 💯.. hoping to learn much from you
@nkem5908
@nkem5908 3 жыл бұрын
Job well done guys
@petrosmzomuhle2755
@petrosmzomuhle2755 4 жыл бұрын
very helpful
@yosslainarthur3153
@yosslainarthur3153 Жыл бұрын
Super
@richardduplessis3023
@richardduplessis3023 4 жыл бұрын
Next time mention the pressure valve on the hot outlet side.Mention also that there must be a 30 amp external breaker box .Otherwise good clip
@mrivormentoor2788
@mrivormentoor2788 4 жыл бұрын
Helpfull very
@jay-peephillips2349
@jay-peephillips2349 Жыл бұрын
THE BRUIN OU, IS THE MAIN OU!!! 💪💪💪 KUDOS TO THESE OU'S, THEY ARE YSTERS IRON🛠️🔩⚙️
@caiphus321
@caiphus321 2 жыл бұрын
I'm confused. You cut the cold water supply pipe and fit it to the inlet of the geyser as well as the outlet? You just changed water supply to the house to only hot water I think. Plus there's no syphon loop on this installation...
@nkhumelenimangale4260
@nkhumelenimangale4260 2 жыл бұрын
I thought I didn't know my story until I read your comment. The must he a Tee after pressure valve so the water can be balanced in the house.
@gemi1164
@gemi1164 Жыл бұрын
My geyser was ook buite, totdat diewe die koper fittings kom afbreek het. Volgende keer elektifiseer ek dit.
@aurethlouw8274
@aurethlouw8274 2 жыл бұрын
Please, teach that bloke to use a copper cutter 😅
@johnnysowden2924
@johnnysowden2924 Жыл бұрын
the narator does not know what is going on here, kwikot geyser are old school and need to be updated, solar instlation is not shown in this video, the presure valve should be instlalled at the water meter side to alow the cold and hot water to have the same presure.
@otherman2958
@otherman2958 3 жыл бұрын
I have a 600kpa gyser but the pressure control valve of the cold water inlet to the geyser is 200kpa. Can that be the reason I get low pressure on all the hot water taps around the house? Thanks in advance
@motswadiwamonna3880
@motswadiwamonna3880 4 жыл бұрын
I am learning from you guys, thanks a lot.
@trevorelgram846
@trevorelgram846 8 ай бұрын
If my tank is fitted underneath my bath ceiling the two vacume green breakers do these have to be installed if fitted horizontally
@mikethesparky4000
@mikethesparky4000 3 жыл бұрын
Just a question why do you put ptfe tap around the ring of a copper pipe. Didn't think you needed to do that
@bekkiebeans6004
@bekkiebeans6004 2 жыл бұрын
You are right, ptfe tape is not required around the rings for that type of fitting
@njongomatole6037
@njongomatole6037 2 жыл бұрын
It is required but it's not a must but wise plumbers they like to do things ones so it ensures that your fittings will never leak due maybe to the faulty on the rings
@liandraprinsloo6670
@liandraprinsloo6670 4 жыл бұрын
I now you are in South Africa
@liampringle2673
@liampringle2673 4 жыл бұрын
How do you clean the pressure valve cartridge behind the geyser tank? There is no syphon loop on this install?
@njongomatole6037
@njongomatole6037 2 жыл бұрын
You have little knowledge man do you know that the Vacuum breakers can also works as anty
@Visionery1
@Visionery1 3 жыл бұрын
Years ago we spent some time in Montagu during August when outside temps were around 6 degrees, they also had their geyser outside, needless to say the geyser was on 24/7 trying to heat the water to 75 degrees. It would be interesting to see the consumption for the above installation.
@andrewg.mvisser5027
@andrewg.mvisser5027 2 жыл бұрын
And inside the roof it is not 6'C?
@Visionery1
@Visionery1 2 жыл бұрын
@@andrewg.mvisser5027 no, many roofs are insulated.
@andrewg.mvisser5027
@andrewg.mvisser5027 2 жыл бұрын
@@Visionery1 and in SA most roofs are not.
@nathanblacklaws9669
@nathanblacklaws9669 9 ай бұрын
I live there :)
@nathanblacklaws9669
@nathanblacklaws9669 9 ай бұрын
I live there :)
@FoolyLiving
@FoolyLiving 2 жыл бұрын
Why not on the roof where it can get full sun?
@hendrikcoetser9853
@hendrikcoetser9853 6 ай бұрын
Antisyphon loop t piece must be 100mm obove the geyser this one to low
@myjames48
@myjames48 11 ай бұрын
No need for ptfe tape on those fittngs with a ring. It is actually a sealing ring. Does not need tape. 😢😢😢
@SpottedEagleOwls
@SpottedEagleOwls 2 жыл бұрын
Why must a vacuum breaker installed higher than 300mm above geyser
@njongomatole6037
@njongomatole6037 2 жыл бұрын
Not higher than that but from the Tee 30cm exactly
@justinhall7489
@justinhall7489 3 жыл бұрын
It's a vacume breaker not for solar man
@sandilevgina1392
@sandilevgina1392 4 жыл бұрын
What if I have low pressure on cold water going to geyser?
@njongomatole6037
@njongomatole6037 2 жыл бұрын
That can result to the burn on your element so you need to install the booster pump to make sure your water supply is active
@charlium
@charlium 4 жыл бұрын
Very helpful👌
@jabulanemaphaphu8211
@jabulanemaphaphu8211 4 жыл бұрын
How do I empty the geyser, same one as that.,......laymen terms please
@philipjooste9075
@philipjooste9075 3 жыл бұрын
Maybe you've found it by now but you do that by opening the drain cock on the cold side. If there is not vacuum breaker on the hot side it might no drain easily or at all. In this case remove the safety valve or loosen the hot outlet to "break the vacuum"
@ebrahimgamieldien8
@ebrahimgamieldien8 3 жыл бұрын
Where is the cold water supply to the rest of the house ? Isn't that missing here. Cause the geyser was connected from the main water supply
@randellouw7940
@randellouw7940 3 жыл бұрын
I was watching this video last night and something bothered me about this, i watched again and saw that there is no cold water supply to the house, so im not sure why they didnt do it like that, would love to know
@justineaves4397
@justineaves4397 3 жыл бұрын
The system is unbalanced this is the reason for no cold water supply and also they never installed a non return valve to prevent back flow into the system.
@andrewg.mvisser5027
@andrewg.mvisser5027 2 жыл бұрын
As per SANS this is a bust. Installing a geyser DIY can lead to serious harm.
@thunderstorm6616
@thunderstorm6616 2 жыл бұрын
Most Diy guys do it better than qualified plumbers
@capechronicler
@capechronicler Жыл бұрын
@@thunderstorm6616 True, but you're insurance company won't view it that way if you can't produce a certificate if it bursts and floods your house.
@princemazibuko6830
@princemazibuko6830 Жыл бұрын
So why they putting ptfe
@patricksteytler7342
@patricksteytler7342 2 жыл бұрын
There goes some profit because nobody knows how to bend
@rolandburisch9489
@rolandburisch9489 2 жыл бұрын
Good video but perhaps don't include each and every joint being tightened, very repetitive and pointless. I also would have liked to have seen something about the electrical supply requirements.
@xolanimthethwa4149
@xolanimthethwa4149 Жыл бұрын
This piping is so wrong, using PTFE on ring's on conex fittings 😢😢
@nurruddeen_87
@nurruddeen_87 3 жыл бұрын
unbalanced system. Your cold water to supply the house should be after your PCV.
@bandahazel8803
@bandahazel8803 Жыл бұрын
There not plumbers those dude how can take 2 minutes to cut a pipes? No t for balance water, vacuum valve is for the air
@patricksteytler7342
@patricksteytler7342 2 жыл бұрын
Non compliant. No anti syphon loop.
@CosmasNgidi
@CosmasNgidi 29 күн бұрын
Houmush
@Yesterdie02
@Yesterdie02 3 жыл бұрын
It’s a freaking compression fitting ! Wtf would need ptfe tape over that for ! This is a really poor video of plumbing techniques and practice . De burring the pipe is the term FYI sies Julie 😜
@nazeemhendricks8325
@nazeemhendricks8325 2 жыл бұрын
aweh!
@wafiqahcarelse9108
@wafiqahcarelse9108 4 жыл бұрын
Who ever dislike this video has seriouse problems better then this must be wrong
@tinashel.gadzikwa4358
@tinashel.gadzikwa4358 3 жыл бұрын
Good video. However it is important to note that when installing a geyser, there is need to balance the pressure on the cold water supply i.e. cold water for the rest of the house and for the geyser supply. To achieve this, cold water supply to the rest of the house must be connected after the pressure valve. So its pressure valve, tee junction (house cold water supply and geyser cold water supply) and straight valve Now if you do that you achieve a balanced water pressure on both cold and hot water. Thank you
@randellouw7940
@randellouw7940 3 жыл бұрын
There is just a slight problem with the installation, no cold water supply to the house
@justineaves4397
@justineaves4397 3 жыл бұрын
It's not completely wrong but as a plumber I have to say it's not a proper installation
@matto6195
@matto6195 2 жыл бұрын
Anti siphon loop not high enough. No cold water supply to the rest of the house after the prv.
@patricksteytler7342
@patricksteytler7342 2 жыл бұрын
Wy
GAP   Electric Geyser Installation
9:10
GAP Geysers South Africa
Рет қаралды 59 М.
VTS 02 2
26:37
Carel B
Рет қаралды 21 М.
طردت النملة من المنزل😡 ماذا فعل؟🥲
00:25
Cool Tool SHORTS Arabic
Рет қаралды 32 МЛН
Magic trick 🪄😁
00:13
Andrey Grechka
Рет қаралды 67 МЛН
КТО ЛЮБИТ ГРИБЫ?? #shorts
00:24
Паша Осадчий
Рет қаралды 4,3 МЛН
Angry Sigma Dog 🤣🤣 Aayush #momson #memes #funny #comedy
00:16
ASquare Crew
Рет қаралды 45 МЛН
How to test a geyser / boiler thermostat
4:32
ecologicaltime
Рет қаралды 43 М.
Solar Geyser Retrofit
6:03
Bidvest Renewable Solutions
Рет қаралды 80 М.
How To Install Your Own Emergency Backup Tank
9:11
BuildersSA
Рет қаралды 239 М.
Why does a geyser need a TP Valve?
6:04
Apollo Solar Technology
Рет қаралды 26 М.
Tech Talks   16 March 2023
30:30
The Institute of Plumbing SA
Рет қаралды 2,8 М.
How to Diagnose and Repair a Hot Water Cylinder/Geyser
7:44
How to Install a Water Heater - Step-by-step
27:59
How2Plumb
Рет қаралды 1,2 МЛН
When Does Your Geyser's Sacrificial Anode Needs Replaced?
2:35
BuildersSA
Рет қаралды 56 М.
طردت النملة من المنزل😡 ماذا فعل؟🥲
00:25
Cool Tool SHORTS Arabic
Рет қаралды 32 МЛН