I've been utilizing my 10k solar inverter for nearly half a year, and overall, it has proven to be a highly satisfactory experience. However, I have observed that when encountering an error code, is there a more efficient method to reset the code without the need to power down the entire system and initiate a complete reboot? Thanks for a great product.
@PowmrSolar11 ай бұрын
Hi, please send your problems to this email: support@powmr.com. Please note that we may not be able to promptly respond to you due to the Lunar New Year. We apologize for the inconvenience this may take and thank you for your understanding. We wish you all the best!
@WintedTindows16 ай бұрын
hi, are you able to adjust parameter 4? this is the battery cutoff voltage/switch back to grid threshold. I am unable to adjust it (when I make the adjustment and hit enter it seems to work but when I exit setting and then go back to check it is back to the default value rather than the one I programmed in). Also: have you had any issues since you made the above comment? Thanks and I hope you see this
@harty9018 Жыл бұрын
ist der SunSmart10K in parallel Schaltung möglich ( 2x SunSmart10K auf 2 Phasen ?
@PowmrSolar Жыл бұрын
Hi, this model cannot be used in parallel.
@dannysuru Жыл бұрын
Hi looks good but can I use a generator to ac input when no sunshine and off grid ?
@PowmrSolar Жыл бұрын
Yes. you can use a generator to connect this model.
@filthyfoxbodyАй бұрын
I have tried 2 different generators.. no luck
@healtechpr5659 Жыл бұрын
Max. Voltage of Open Circuit 500Vdc, is it for each individual mppt, or is it 500vdc for both?
@PowmrSolar Жыл бұрын
For each, but the maximum input current is that the sum of the two does not exceed the PV maximum input current(22A)
@healtechpr5659 Жыл бұрын
@@PowmrSolar Ok, to see if I'm okay… 1st Mppt 500Vdc 2nd Mppt 500Vdc 22A for both
@alisaggaf74978 ай бұрын
Solar Panel array, Watts not to exceed 11KW
@freddyc2121 Жыл бұрын
Hello, I need information about the wiring, I already saw the video,I already read the manuel, but in case I need to bypass from input from utility AC 240V, how do I apply the 240V comming from the mains to the inverter and the load , in the video it shows from input 120v , but if I need to use L1 and L2 + N at the input to feed the load and to charge the battery. Let's say, I use a laundry dryer at 240V connected to the inverter that will runn fom the batteries only of the utility power goes off, so initially it will take from utility at 240V and then if power from the grid fails, it will switch to batteries.
@MrBmonroe924 Жыл бұрын
are you able to wire two of these units in parallel?
@PowmrSolar Жыл бұрын
This model cannot be used in parallel
@amelieelibh Жыл бұрын
I installed the 10k power inverter with 8 550w solar panels in serial. Only in one MPPT, and I don't have batteries yet. It works sending V from the sonar panels and Utility to the load, but it is throwing an error 03. How can I configure it to work without requiring batteries?
@PowmrSolar Жыл бұрын
Hi, the POW SunSmart10K model, right?
@amelieelibh Жыл бұрын
@@PowmrSolar correct!
@PowmrSolar Жыл бұрын
@@amelieelibh Please connect PV and mains power at the same time, then set AC 1ST in item 01 and LOD in item 34.
@amelieelibh Жыл бұрын
@@PowmrSolar I already configured utility in the option 01, and mix load in the option 34. And it worked, but the battery alarm never finished and all the time throws fault (even working). Is there a way to configure it to avoid requesting for the batteries?
@PowmrSolar Жыл бұрын
@@amelieelibh You can turn off the alarm in item 25.
@johnmelvin4091 Жыл бұрын
If i have a 4 -12 volt lifepo4 batteries setup for 48 volts, which setting should I use. LFP14, LFP15, and LFP16?
@PowmrSolar Жыл бұрын
Hi, LFP16.
@johnmelvin4091 Жыл бұрын
So, I read the manual from top to bottom and in it states that the LFP14, LFP15, and LLFP16 setting, is the number of cells in your battery setup. A 12 volt Lifepo4 battery has 4 cells x 4 batteries is 16 = LFP16. Just an FYI for anyone else wondering. Thank you for the quick reply.
@davemacdonald5106 Жыл бұрын
is this CSA and UL certified
@gabaradama144k9 Жыл бұрын
Do I have to have two units for 240 V split phase power
@PowmrSolar Жыл бұрын
One unit is ok.
@esdrasemile1450 Жыл бұрын
Good morning
@edwardstewart457524 күн бұрын
How do u hook up a 240vac well pump. Two hot legs, one ground and no neutral wire.
@PowmrSolar24 күн бұрын
Please send your inverter product label to this email: support@powmr.com. Our technical staff will check it for you.
@mattclark79418 ай бұрын
Hi will this inverter put out 230v to 240v in the single phase for uk?
@PowmrSolar8 ай бұрын
Hi, this model is only for USA.
@MiguelLlanes-vn1wc Жыл бұрын
Puedo conectar paneles orientados al este a una entrada de paneles y orientados al oeste a la otra
@PowmrSolar Жыл бұрын
Yes, you can connect like this.
@sgn8471 Жыл бұрын
Hi Powmr, which model and watts can be Parallels..? and what’s AC Main output and 2nd AC output…? Thanks….I’m going setup a 48v to 240v system
@PowmrSolar Жыл бұрын
Hi, this model can be used in parallel. The product link for your checking as below: powmr.com/products/hybrid-inverter-charger-5000w-48vdc-110vac-for-parallel
@paco30amigos3 ай бұрын
Is it possible to reduce the power to 6wk instead of 10kw?
@PowmrSolar3 ай бұрын
You can choose the 6KW model.
@poe1601702 ай бұрын
coloque 12 paneles de 400w 13amp en un solo mppt dice que esta produciendo 400V pero cuando enciendo mi aire acondicionado de 220v 1200watt no arranca el compresor, si conecto los paneles 6 por mppt se suman las corriente?
@PowmrSolar2 ай бұрын
the SunSmart 10k model?
@poe1601702 ай бұрын
@@PowmrSolar si
@PowmrSolar2 ай бұрын
@@poe160170 The current is constant. Doesn't add up
@poe1601702 ай бұрын
@@PowmrSolar yes
@poe1601702 ай бұрын
@@PowmrSolar si lo conecto a la red el a/a arranca perfectamente pero cuando corto la energia de la red para que trabaje con los paneles el compresor se apaga inmediatamente, aun cuando el tablero indica que esta recibiendo 400v de los paneles
@patrickjean-francois91564 ай бұрын
Nice product, how do I charge my batteries with utility power?
@PowmrSolar4 ай бұрын
Go to the 06 setting item and set it according to your needs.
@mugiraharjo62709 ай бұрын
hope adding feature for paralel multiple inverter,
@PowmrSolar9 ай бұрын
This model has a parallel version.
@TemporalReconnaissance177th8 ай бұрын
Impressive
@paco30amigos3 ай бұрын
Is there any way to set Export limit to zero?
@PowmrSolar3 ай бұрын
There is anti-backflow software inside the machine, so no current will be fed into the power grid.
@CurrentEventUpdated2 ай бұрын
@PowmrSolar how do I set this?
@PowmrSolar2 ай бұрын
@@CurrentEventUpdated What to set?
@technadi4556 Жыл бұрын
has this inverter a limiter
@PowmrSolar Жыл бұрын
This model has built-in CT.
@bimmers323ci10 ай бұрын
Hi is this unit stackable
@PowmrSolar10 ай бұрын
Hi this model can't be used in parallel.
@bimmers323ci10 ай бұрын
@@PowmrSolar hi can this inverter run two 4hp motor @ 240v
@PowmrSolar10 ай бұрын
@@bimmers323ci Hi, this inverter can not run two 4hp motor at the same time.
@bimmers323ci10 ай бұрын
@@PowmrSolar ok the what can you recommend
@PowmrSolar10 ай бұрын
@@bimmers323ci Hi, you can use two units.
@johsell07 Жыл бұрын
How to contact you to buy the inverter?
@PowmrSolar Жыл бұрын
Hello, kindly check the website: powmr.com/
@johsell07 Жыл бұрын
Do you have any e mail for support? I have a few questions of this sistem
@PowmrSolar Жыл бұрын
kindly contact this email: support@powmr.com
@MakeItAdmirable Жыл бұрын
Can you do a video for SP5K 5000W 48Vdc 110Vac Hybrid Inverter Supports Up to 6 Units in Parallel
@PowmrSolar Жыл бұрын
Hi, Ok. Stay tuned we will arrange later.
@hiz3586 Жыл бұрын
Si, seria muy interesante conocer esa configuracion y el equipo
@jojohnny438611 ай бұрын
Hello my inverter HVM4.5K-24V At the 12 marathon it doesn't have volts. How to set the Back to Battery? But why the ampers? How should it be set up? Or do I need to update the software? Thank you
@PowmrSolar11 ай бұрын
Hi, please send your problems to this email: support@powmr.com. Please note that we may not be able to promptly respond to you due to the Lunar New Year. We apologize for the inconvenience this may take and thank you for your understanding. We wish you all the best!
@muhammadshahzadyousaf12828 ай бұрын
our inverter POW-HVM6.2M-48V-N installed a day ago, error 52 appears and the system is not restarting. what to do further? please advice.
@PowmrSolar8 ай бұрын
Please send your problem to this email: support@powmr.com. Our teachnical staff will handle it for you.
@homeinspectionlosangeles4189 Жыл бұрын
can this 10k inverter work off grid without the utility connected(while solar pv and battery are connected)??
@PowmrSolar Жыл бұрын
HI, sure, this model can work off grid.
@ramsaybolton9099 Жыл бұрын
Thank you for this video, it was quite comprehensive. Can this unit can be monitored by an app?
@PowmrSolar Жыл бұрын
Hi, this APP(SmartESS).
@poe1601702 ай бұрын
donde descargo el software ipower
@poe1601702 ай бұрын
para monitorear con la lapto
@PowmrSolar2 ай бұрын
Envíe su problema a este correo electrónico: support@powmr.com. Nuestro personal técnico se encargará de ello por usted.
@vladflorin782110 ай бұрын
I have a question if not intruding, I recently bought a 10,2kw inverter and don't understand what they use two outputs for,Main output, Second output?? I'm under the impression that is not a 10kw inverter, but two inverters of 5kw each!?!? Please explain to me to understand, in the user manual it doesn't say anything about this subject.. thanks, I appreciate.. Looking forward for the answer
@PowmrSolar10 ай бұрын
Hi, the distinction between primary and secondary. Under normal circumstances, the ordinary load is connected to the main load terminal. If the battery power is insufficient, the inverter will lose power and stop working. However, in order for some loads to be kept powered on all the time, there is a secondary load, which means that even if the battery power is a little low, the main load is still disconnected and only the secondary load is carried, thereby keeping the secondary load uninterrupted. This function requires setting items 41 and 42 to be turned on.
@atlw12210 Жыл бұрын
POW-HVM5.5K-48V-LIP missing RS485 communication cable. How do I get one?
@Ozzie-bq8vq7 ай бұрын
I just installed my 10K inverter and I can barely see the display, not bright enough, what am I doing wrong? Help!
@PowmrSolar7 ай бұрын
Hello, please send your problems to this email: support@powmr.com. Our technical staff will check it for you.
@ridersmotoz2457 Жыл бұрын
Still available and Hm??
@PowmrSolar Жыл бұрын
Hi, this model(POW SunSmart10K)?
@christianbravophotography4705 Жыл бұрын
How is the maximum capacity (kilowatts) in battery for this inverter?
@PowmrSolar Жыл бұрын
Capacity is not required, but we suggest not to connect too much (200AH-400AH)
@alisaggaf74978 ай бұрын
Can I connect 5 Units of Lifepo4 batteries 51.2x280AH (parallel) to this inverter?
@MakeItAdmirable Жыл бұрын
What is the difference between LFP14, LFP15, and LFP16? Im not sure which one to select.
@PowmrSolar Жыл бұрын
Hi, we would like to know what is the voltage of your lithium battery.
@MakeItAdmirable Жыл бұрын
@@PowmrSolar 51.2 volt 100Ah
@PowmrSolar Жыл бұрын
@@MakeItAdmirable Recommend you choose LFP16.
@MakeItAdmirable Жыл бұрын
@@PowmrSolar Ok thank you!
@JosephCaile-js1wq10 ай бұрын
Where is the anti reflux settings?
@TwoK24 Жыл бұрын
What is the proper procedures for switching ON the inverter which first PV, BATTERY, AC IN? and what is for switching OFF which first PV,BATTERY ,AC?
@PowmrSolar Жыл бұрын
Hi, you need to turn on the battery switch first, then PV, the last is AC IN. The order of turning them off is AC IN first, then PV, then battery.
@TwoK24 Жыл бұрын
@@PowmrSolar thank you so much
@missinglink20819 ай бұрын
why can't I change my parameter 01
@PowmrSolar9 ай бұрын
Please send your questions to this email: support@powmr.com
@amelieelibh4 ай бұрын
Hello, me again. I just realized after 9 months of usage that my inverter is not delivering enough power. I installed 8 solar panels of 550W, with 13A. But for some reason, the inverter never deliver more than 1~1.2A. I tested already the panels and they are working, delivering at least 360V. But when I turn on anything that requires more than 1A, the inverter switches to utility and stop using solar power. I'm not able to generate more than 0.5kWh, and I've seen several videos with people that with a half of solar panels I got, they're generating 3.5kWh. Please help me, I tried to write to the Facebook group, but nobody is willing to help me😢
@PowmrSolar4 ай бұрын
Have you contacted this email: support@powmr.com?
@amelieelibh4 ай бұрын
@@PowmrSolar I sent an email via the contact us form in the page with no response. Yesterday I sent another email but directly to that address, I'll wait to see if they respond. Thank you!
@PowmrSolar4 ай бұрын
@@amelieelibh Can you send us your email?
@amelieelibh4 ай бұрын
@@PowmrSolarhello, thank you for your attention. my email starts with this same alias (in this KZbin user)
@directionschoolnoorcampus Жыл бұрын
Price in pkr
@PowmrSolar Жыл бұрын
Hi, kindly check the product link: powmr.com/products/hybrid-inverter-charger-10kw-48vdc-split-phase-110vac-or-240vac
@MiguelLlanes-vn1wc Жыл бұрын
Hola
@saulvasquez1058 Жыл бұрын
Please upload this video in Spanish. thank you
@atlw12210 Жыл бұрын
POW-HVM5.5K-48V-LIP missing RS485 communication cable. How do I get one?