@stevethecat9194 Жыл бұрын
Excellent video. I am a non professional. This is exactly what i needed.
@RoofRepairSpecialist Жыл бұрын
Glad it was helpful. Good luck on your project, let me know if any questions come up
@rerite2 Жыл бұрын
Same here.
@PeteLeuenberger4 ай бұрын
Thanks for your great videos, the best I've found. Why not install a long flashing piece that covers the entire length, under all shingles ? Vs this layered, cascade like approach ?
@RoofRepairSpecialist4 ай бұрын
Definitely don’t do that. Step flashing kicks the water out and doesn’t allow water to travel under the shingle.
@PeteLeuenberger4 ай бұрын
@@RoofRepairSpecialist Ok, I get it now. Thanks !
@donforman4326Ай бұрын
what about the counter flashing install?
@timlarge8927 Жыл бұрын
Only 3 nails per shingle? How many nails are required by the product approval for the shingles?
@nathanielvelazquez114710 ай бұрын
These are OC duration shingles. 4 or 6 nail pattern is acceptable per manufacturer installation instructions
@MrVincentj46 Жыл бұрын
Great video, thanks
@RoofRepairSpecialist Жыл бұрын
Very welcome
@saintmichael1874 Жыл бұрын
THX sooo much !!!
@RoofRepairSpecialist Жыл бұрын
Thanks for watching.
@stumpynubs5387 Жыл бұрын
How do you flash the top part of the skylight?
@RoofRepairSpecialist Жыл бұрын
I have a video on that.
@nathanielvelazquez114710 ай бұрын
With regular shingle flashing, which you can honestly run shingle flashing aground the perimeter of curb and seal with a 3 course of bull membrane bull
@mmichaud0810 ай бұрын
everywhere else you use an entire piece of metal, but for some reason in the corner you just need a little goop?
@RoofRepairSpecialist10 ай бұрын
?
@ilovethisroofingjob2 жыл бұрын
Good
@RoofRepairSpecialist2 жыл бұрын
Thanks
@toddavis86037 ай бұрын
Not too shabby!"
@highnoter1 Жыл бұрын
Don't nail the flashing into the shingle. You are introducing an extra hole into the flashing. Why would you do that?
@RoofRepairSpecialist Жыл бұрын
We generally dont nail it to the curb, especially if it is a brick fire place you are not able to do so. The nail we put in will be covered by the next row of shingles and flashings.
@tyfreedom57932 жыл бұрын
2:08 wrong, wrong wrong.. like very very wrong….🤦🏼♂️
@RoofRepairSpecialist2 жыл бұрын
Your wrong
@tyfreedom57932 жыл бұрын
Actually no I’m not… that’s so incorrect it’s not funny
@tyfreedom57932 жыл бұрын
And it’s “you’re” lol 😉
@JonathanSHoover2 жыл бұрын
Yea I agree, I'd wrap the outside corner on the first piece of step, also you're guy is nailing very close to the skylight
@dynastyroofingcny2 жыл бұрын
Just because it’s not wrapped doesn’t mean it’s wrong. I’ve seen hundreds of roofers install this exact way and I’ve never seen anyone have an issue. Have an open mind, their are plenty of ways to do things on a roof
@olcotttheosophy2 жыл бұрын
☑️👍
@RoofRepairSpecialist2 жыл бұрын
Thanks for the thumbs up!
@whommee Жыл бұрын
putting that nail in the end of the shingle close to that curb, through the step flashing is a terrible thing to do
@RoofRepairSpecialist Жыл бұрын
The next row of step flashing covers said nail. If your not dealing with Ice and snow its not a problem.
@nathanielvelazquez114710 ай бұрын
Why not have some peel n stick running up the curb along side and head wall of that curb? Your video shows no water penetration but it’s not sealed properly and any wind driven rain will leak.
@RoofRepairSpecialist10 ай бұрын
I’ve never had a leak because of that, peel and stick is called ice and water shield and when used in similar situations is for ice
@audielgomez25513 ай бұрын
Tk
@patryksawicki30786 ай бұрын
Wrong 😂😢
@RoofRepairSpecialist6 ай бұрын
lol, really sounds like you know best
@stephanietrapasso14474 ай бұрын
You have no idea what you're doing.
@RoofRepairSpecialist4 ай бұрын
Why is that?
@AD-hs4cwАй бұрын
dont put the step flashing down over the glue stick of the previous shingle for obvious reasons...come on man
@RoofRepairSpecialistАй бұрын
??
@AD-hs4cwАй бұрын
@@RoofRepairSpecialist the glue strip on the shingle...when you put the next shingle down you want that glue from the previous single to connect and form a nice melted glue seam...but when you put the step flashing down to far on the shingle you stop that from happening. this is common sense