Bhai me agar is ko silver wire se wind karon to kaam kary ga or is me silver wire me kitna tar lagy ga
@rabishankarbiswas5929 Жыл бұрын
is vdo mei aapne kis size ka wire use karna hai iska formula nahi bataya is vdo mei.
@shamimahmed45562 ай бұрын
Bhai sahab Assalamualaikum Aapne likha hua data sirf padh liya. Takniki details nahi bataya. 80v se 250v ke liye tapping kitna volt se nikala uska calculation nahi bataya. Voltage variant kitna se kitna Tak rahega, phir 1st relay trip karega. 2nd relay ke liye usi tarah kitna se kitna volt rahega, phir 3rd Relay ko trip karega.... Sirf parh liyahogaya, aisa to nahin hota. Main batata hoon... Agar 80v se uthana hai to 1st tapping niklega 80*1.45=116, usi tarah baki sab hog. Lekin aap to 80 se hi nakala hai, jab usi tapping me 100 volt denge to kya hoga jal bhi sakta hai. Isiliye variant kam se kam 1.4 guna rakha jata hai. 80-116 1st relay, phir us se jyada hone par 2nd relay trip karega. Theory bahut lamba hai. Capacity ke hisab se yani power factor 0.8 leker KVA calculate aur Bobbin size tah kiya jata hai. Phir TPV calculate Kiya jaata hai. Current ke hisab se primary aur secondary current par SWG tah kiya jaata hai. Yahan itna kuchh likhna mushkil hai.
@gorayaelectric3 жыл бұрын
Is py 16 number kesy pora ho ga baban py vo number muta hota h