The video teaches on a white board how to make a snare from coronary wire. Please feel free to comment and give your suggestions and enhance the thread to help others
Пікірлер: 8
@smtandel6 ай бұрын
Thanks a lot. You saved me today, stent was dislodged from balloon on wire. Couldn't enter a sheath. Snare was not available in cath. Rapidly checked your video and shared it out. One tip is that take a L shaped cut on catheter tip. Remove the flap to increase cross sectional area.
@highriskpci50044 ай бұрын
Glad it helped!
@waheedashraf9612 Жыл бұрын
MashaAllah ..Great waqas bhai
@hussanraza4010 Жыл бұрын
Great ma sha Allah
@alwayurs2000 Жыл бұрын
How to go from sheath till aorta, without over the wire
@highriskpci5004 Жыл бұрын
Great question, you will need 0.018 wire to get the catheter over to the location if using a 6F catheter otherwise you can use 0.035 wire for larger catheter sizes. The back end of the wire should already be through the guide catheter that you are using as a snare.
@kzhraloz8 ай бұрын
Was thinking the same
@ikramahmed82622 ай бұрын
wire or anything which is to be retrieved will not enter into the guiding catheter. We have to pull out whole system. This can damage the vessel. Any solution for that?