How to Meg a Motor with a Megohmeter - Checking Motor Condition

  Рет қаралды 398,674

GalcoTV

GalcoTV

Күн бұрын

Megging a motor presented by Katie Nyberg for Galco TV. Buy the items featured in this video at 800-337-1720 or visit: www.galco.com/s...
Megging a motor is a term used to test a 3 phase motor to check the resistance and condition of the motor windings using a megohmeter. These type of motors produce an electrical charge to conduct a resistance reading. If there is a low amount of resistance in Megohms then the motor may need to be serviced or replaced. This test used for preventative maintenance.
Sign up for Galco’s newsletter that features our newest products, our can't-miss deals, our best videos, and total access to Galco’s electronics expertise: www.galco.com/e...
Connect with us!
plus.google.co...
/ galcoindustrial
/ galcoindustrial
/ galco-industrial-elect...
Don't forget to like and comment on this video, and subscribe to our channel!
Galco is a Factory Authorized Stocking Distributor for Over 150 Brands of Industrial Electrical & Electronic Automation, Controls and Component Products; On-Site and Send-In Repair Services for Industrial Control & Automation Products for Over 2,000 Brands; Engineered Systems Integration, Retrofits & Upgrades for Variable Speed Drives, CNC, PLC Systems, Dynamometers & Test Stand Applications. Visit us online at www.galco.com or call us at 800-337-1720.
www.galco.com/s...
With respect to the usage, installation or assembly of any products described in this video, Galco Industrial Electronics, Inc., a Michigan corporation, encourages you to follow the requirements and/or guidelines of: i) the Occupational Safety and Health Act of 1970, Public Law 91-596, as amended, and all laws, rules and regulations implemented in relation thereto; ii) the National Electric Code®; and iii) NFPA 70E®. Any installation, assembly or work described in this video should be performed by a qualified licensed electrician.
GTV, Galco, galco.com, Galco Industrial Electronics, and Galco Industrial Electronics, Inc. are registered and/or pending registered trademarks under the U.S. Patent and Trademark Office, assumed names, registered domain names, and/or trade names of Galco Industrial Electronics, Inc., a Michigan corporation.
LEGAL DISCLAIMER:
While we have made every attempt to ensure that the information provided is accurate and has been obtained from reliable sources, Galco is not responsible for any errors or omissions, or for the results obtained from the use of this information. All information is provided "as is", with no guarantee of completeness, accuracy, timeliness or of the results obtained from the use of this information, and without warranty of any kind, express or implied, including, but not limited to warranties of performance, merchantability and fitness for a particular purpose. At all times you should defer to the instructions and safety guidelines issued by the manufacturer. In no event will Galco, its agents or employees thereof be liable to you or anyone else for any decision made or action taken in reliance on the information provided to you or for any consequential, special or similar damages, even if advised of the possibility of such damages.

Пікірлер: 56
@audievickers132
@audievickers132 2 жыл бұрын
Thanks, Katie. Short, to the point, and easy on the eyes.
@chrisb7051
@chrisb7051 10 ай бұрын
Gross dude
@pc2753
@pc2753 3 жыл бұрын
Warning! There is no-one like Katie in this industry.
@seannot-telling9806
@seannot-telling9806 5 жыл бұрын
Thank You for a good demonstration. The audio was nice, crisp and clear.
@destinylags6863
@destinylags6863 Ай бұрын
What is a"low reading " considered to be though
@Infotainer14
@Infotainer14 9 ай бұрын
Can you share motor configuration with Unidrive so 1405 and also parameters needed
@electronicatutorial
@electronicatutorial 7 жыл бұрын
Beautiful presentation literally.
@GalcoIndustrial
@GalcoIndustrial 7 жыл бұрын
Thank you for your kind words
@lupojacobo9892
@lupojacobo9892 4 жыл бұрын
😁
@bhim2234
@bhim2234 5 жыл бұрын
hello,a question should not we disconnect the star point connection prior to measurement?thank you
@kamioool933
@kamioool933 4 жыл бұрын
No
@kamioool933
@kamioool933 4 жыл бұрын
Make sure you have nice ground connection, she put crocodile on paint 🤭🤯
@TiberiusStorm
@TiberiusStorm 4 жыл бұрын
Yes but that was ground on the housing so she really had not other choice.
@jesusrperezd
@jesusrperezd 7 жыл бұрын
What about phase winding isolation and testing phase to phase insulation?
@GalcoIndustrial
@GalcoIndustrial 7 жыл бұрын
Phase to phase windings are connected together at each motor terminal and are very low resistance. As for "phase-isolation", if you are referring to the windings staying insulated apart from each other, that would be done with an Inductance and milliohm meter. This Video was to demonstrate using a Megohmeter to test a motor that is all.
@maxquad6846
@maxquad6846 5 жыл бұрын
You have a point. I was taught to separate the windings when doing the meg test to ground.
@kuhlmaja
@kuhlmaja 5 жыл бұрын
@@GalcoIndustrial Could you explain that process?
@user-oc1zq1ej5c
@user-oc1zq1ej5c 2 жыл бұрын
@@GalcoIndustrial bollocks, should have tested Phase to Phase with a merger.
@KAKURYENTE_TV.
@KAKURYENTE_TV. 9 жыл бұрын
very useful
@GalcoIndustrial
@GalcoIndustrial 9 жыл бұрын
+Alvin Andal Thanks!
@KanubhaiPatel-gn9iz
@KanubhaiPatel-gn9iz 8 жыл бұрын
fieldwindig
@mohammednafeezn
@mohammednafeezn 7 жыл бұрын
Excellent presentation!!
@Maddtommy2025
@Maddtommy2025 Жыл бұрын
Great job. Now I can do mine. Lol
@ianfraser2009
@ianfraser2009 4 жыл бұрын
Hi There, great video. I was wonder if you can answer this question. I don't have a megger for testing 3 phase motor. However I am testing phase to earth and getting a reading of 1.000 ohms. Is this normal? I was taught that I should not get any reading on ohms going from phase to earth. I am getting mixed information in the field. Any info would be appreciated.
@logmeindog
@logmeindog 4 жыл бұрын
That sounds like a bad reading to me. Compare that measurement to the other phases/coils.
@moisesvargas4543
@moisesvargas4543 3 жыл бұрын
Bad motor
@gregadventures2024
@gregadventures2024 Жыл бұрын
Bad motor but make sure you have all motor leads disconnected from each other
@JohnSchroeder777
@JohnSchroeder777 7 жыл бұрын
A friend said his father used a megger to hunt for worms in the mud for fishing !
@GalcoIndustrial
@GalcoIndustrial 7 жыл бұрын
Some Megger's can generate a lot of voltage. He probably has a 1000volt range on it and it might make the worms want out of the ground if it is shocking them, eh?
@wheelie642
@wheelie642 5 жыл бұрын
Nicely explained, thank-you.
@GalcoIndustrial
@GalcoIndustrial 5 жыл бұрын
Welcome
@37prakhar
@37prakhar 8 жыл бұрын
Excellent
@abdulqadir150
@abdulqadir150 6 жыл бұрын
Good
@عليأسعد-ب5و
@عليأسعد-ب5و 3 жыл бұрын
سلام بدي قديش بيعطى كهرباء وين الشركه من فضلكم ابعتولي رقم الشركه
@oetken007
@oetken007 6 жыл бұрын
Tech plus a smart girl, excellent ;-) Thank you for this video.
@rvdboston9568
@rvdboston9568 3 жыл бұрын
imho, she should NOT rest her palm on the live circuit (motor body) under the test. bad example video
@verhillovalakay5393
@verhillovalakay5393 6 жыл бұрын
Thanks mam beautyfull your my favorate and crash teacher lol hehehe😂😁😀
@Froggability
@Froggability 4 жыл бұрын
Huh? Didn't show the readings, nor explain PASS / MARGINAL /FAIL .
@udayveersingh4411
@udayveersingh4411 6 жыл бұрын
Thanks mam
@JohnSchroeder777
@JohnSchroeder777 7 жыл бұрын
Yeah it had a hand crank on it , sounds easier then shoveling!
@kenwood2874
@kenwood2874 6 жыл бұрын
Generally? Seriously? What about Phase to phase readings? A lot of motors can't be megged to ground. Only phase to phase. Ohmeter for ground fault.
@GalcoIndustrial
@GalcoIndustrial 6 жыл бұрын
Well a Megger is only for phase to ground testing. To do phase to phase you will need a very different piece of equipment. Capable of measuring very low resistances and inductances. A 1HP 3 phase AC motor will have some measurable ohms phase to phase and should be balanced with in 10% or less (a new motor may measure less than 5% variation). At about 10HP and up, you will measure less than 1 ohm of resistance phase to phase.
@Froggability
@Froggability 4 жыл бұрын
GalcoTV. You CAN megger phase to phase. Just lift 3 of the 6 tails and test away. But it's rare to bother with this procedure. Cos normally just megger the whole unit and it's either a pass or a fail.
@Tulfonatic-sarcasticsm
@Tulfonatic-sarcasticsm 6 жыл бұрын
ppe
@GalcoIndustrial
@GalcoIndustrial 6 жыл бұрын
If your asking what this means, PPE usually stands for Personal Protection Equipment.
@utahdesertrider1806
@utahdesertrider1806 7 жыл бұрын
Were you a stewardess? Sounds like it
@GalcoIndustrial
@GalcoIndustrial 7 жыл бұрын
You mean a Flight Attendant,,, nope
@siehayan6073
@siehayan6073 8 жыл бұрын
😃😃😃😃
@АндрейКузьмин-щ7з1х
@АндрейКузьмин-щ7з1х 6 жыл бұрын
Beautiful women
@GalcoIndustrial
@GalcoIndustrial 6 жыл бұрын
Thank you
Motor testing with a Megger MIT230
7:38
Mechanntraining
Рет қаралды 117 М.
3 PHASE MOTOR TESTING - how too PROPERLY
39:04
Actual Electrical Content
Рет қаралды 54 М.
黑天使只对C罗有感觉#short #angel #clown
00:39
Super Beauty team
Рет қаралды 36 МЛН
Арыстанның айқасы, Тәуіржанның шайқасы!
25:51
QosLike / ҚосЛайк / Косылайық
Рет қаралды 700 М.
VIP ACCESS
00:47
Natan por Aí
Рет қаралды 30 МЛН
99.9% IMPOSSIBLE
00:24
STORROR
Рет қаралды 31 МЛН
Megohmmeters (Full Lecture)
16:19
Jim Pytel
Рет қаралды 112 М.
How to use a multimeter like a pro, the ultimate guide
12:55
James Gatlin
Рет қаралды 2,9 МЛН
How to meg a motor, check continuity and evaluate the results.
13:25
The Trainer #47: What measuring voltage on the ground side means
9:38
Using a Megger
17:34
Aircon Academy
Рет қаралды 87 М.
3 Ways to Check Capacitors in Circuit with Meters & Testers
14:48
TampaTec
Рет қаралды 1,8 МЛН
Insulation Testing Fluke-1507 - Fluke Fridays - Episode 106
8:02
Fridays With Brandon
Рет қаралды 90 М.
Fluke 1507 Motor Insulation and low ohm Testing
10:09
LUNORTEK
Рет қаралды 201 М.
Troubleshooting 3 phase motors
11:45
Big Mike H
Рет қаралды 15 М.
黑天使只对C罗有感觉#short #angel #clown
00:39
Super Beauty team
Рет қаралды 36 МЛН