How to Perform a Leak Check with a Helium Mass Spectrometer

  Рет қаралды 56,248

Ipsen

Ipsen

Күн бұрын

Пікірлер: 19
@tjvanderloop1686
@tjvanderloop1686 7 жыл бұрын
Excellent use of a sophisticated "Helium Mass Spectrometer" for NDT-leak testing. Thanks! TJ Vanderloop, CMfgE & LSME & AWS member
@shaunybonny688
@shaunybonny688 11 ай бұрын
How fast should you actually move your helium probe? Seemed like he was moving around very quickly. I work at a titanium melt shop and trying to learn how to do effective vacuum furnace leak testing is like pulling teeth around here. Thanks
@rajdeeppradhan1360
@rajdeeppradhan1360 Жыл бұрын
Sir, is the roughing pump + blower ON while detecting leak? Is it possible to add a calibrated leak to determine the ratio for split flow method?
@tjvanderloop1686
@tjvanderloop1686 7 жыл бұрын
Excellent use of a sophistic "Helium Mas Spectrometer for NDT-leak testing TJ Vanderloop
@jeffpsomething6961
@jeffpsomething6961 8 жыл бұрын
It was a demo leak test. I've done many, many leak checks myself. That being said, remember that it takes the leak detector a few seconds to react. So that small spike could of been from the flanges. Also, he did have too much helium flow. I could hear the helium when he presses the trigger. Also, i've tested the ipsen many times. There could be an internal leak. The diffusion poppet valve cylinder can leak from the seals into the system which can only be detected by spraying helium into the rod side of the poppet valve cylinder. Also, the partial pressure valve can be leaking into the system as well as the backfill valve. So you have to remember if you don't find an external leak, there could be an internal leak. Just some food for thought.
@jeffpsomething6961
@jeffpsomething6961 8 жыл бұрын
+Jeff psomething BTW, I was talking about the first leak, not the second spike.
@moonpiespotlight4759
@moonpiespotlight4759 7 жыл бұрын
Best is to take a bottle of IPA and dip the nozzle in it, then adjust until you get a few bubbles coming out (you cannot even feel that level of output). He also started low and went high on the left side of that end cap. Helium rises, so always start off high (position, not on drugs lol) and work your way down, pausing a few seconds each few inches or so to see if you get a response.
@klou7062
@klou7062 3 жыл бұрын
My biggest question is how much helium flow should 1 be using? When you are dealing with O-Rings or VCR cages for gas lines. I seem to not be able to find a specific spec. I too use IPA and stick the helium gun in the bottle and by looking I only let about 1 bubble a sec come out. I seen ppl use like 20-30 bubbles a sec and find leaks that I didn't find. So it makes me think are they forcing a leak? Or a false leak??
@commonman23
@commonman23 7 жыл бұрын
wow it is a very short and sweet demo,bit quick one too. it would have been more perfoct if more technical data is been added.
@sp052
@sp052 8 жыл бұрын
Why was venting performed right after doing the calibration?
@moonpiespotlight4759
@moonpiespotlight4759 7 жыл бұрын
It only vents the foreline where the calibrated leak connects, else he couldn't remove it. It doesn't vent the internal system.
@nithikasn
@nithikasn 6 жыл бұрын
Dear Sir Can you please reply me what types of pumps using for this jobs?
@ipsenvideos
@ipsenvideos 6 жыл бұрын
The pumps that are used in this video are Leybold brand pumps.
@Robjohn37
@Robjohn37 9 жыл бұрын
1/2 of the people who viewed this are legitimately worried or curious as to how to check for helium leaks. The other half probably played Half-Life.
@Gary-ts6dh
@Gary-ts6dh 4 жыл бұрын
You're laughing at some of us who have never used a helium leak detector before. I lead a fairly sheltered life, so I don't know what 'Half-Life' is (I am guessing it has something to do with radiation.) I appreciate the walkthrough. I've never used our leak detector before, so this video has given me a good look at what I can expect when I turn it on. The man that built our detector in the machine shop has retired; but, now we need to use it.
@CafeBikeGirl
@CafeBikeGirl 9 жыл бұрын
Tech in the video didn't compensate for temperature or depletion of the calibrated leak, his calibration was probably 10-15% off, it's not like a tracer probe test is quantitative though.
@moonpiespotlight4759
@moonpiespotlight4759 7 жыл бұрын
How would he compensate if the calibrated leak is the standard? I realize it's an old comment but it doesn't make any sense unless he's using a mass flow controller and trying to calibrate it to helium, which he isn't. Also, it's not a tracer probe. If it was, it would be pulling in air, not expelling helium.
@kid_funzone3201
@kid_funzone3201 6 жыл бұрын
good
@mirzoxidtursunov326
@mirzoxidtursunov326 2 жыл бұрын
Asalomu alaykum
Fixing a leak in UHV chamber
13:59
Dalibor Farný
Рет қаралды 16 М.
Хасанның өзі эфирге шықты! “Қылмыстық топқа қатысым жоқ” дейді. Талғарда не болды? Халық сене ме?
09:25
Демократиялы Қазақстан / Демократический Казахстан
Рет қаралды 325 М.
Я сделала самое маленькое в мире мороженое!
00:43
Кушать Хочу
Рет қаралды 4,4 МЛН
How to leak check a vacuum furnace using an Agilent HLD Leak Detector
6:01
Agilent Technologies
Рет қаралды 3,9 М.
How to Leak Test an AC With Nitrogen Pressure
8:00
HVAC School
Рет қаралды 234 М.
Varian 959 Mass Spectrometer Helium Leak Detector DS302
2:22
Spector Equipment
Рет қаралды 336
How to Conduct a Hydrostatic Test on Ductile Iron Pipe
3:31
McWane Ductile
Рет қаралды 334 М.
The INSANE Precision of The National Institute of Standards and Technology
14:54
Shell and tube heat Exchanger maintenance-leak test methods-4
10:14
Technical Engineering School
Рет қаралды 66 М.
TitanTest Helium Leak Detector Basic Operation Overview Demo (LACO Technologies)
9:50
Air-tight vs. Vacuum-tight
11:55
AlphaPhoenix
Рет қаралды 1,2 МЛН
Fundamentals of Leak Detection
57:08
Agilent Technologies
Рет қаралды 11 М.
Хасанның өзі эфирге шықты! “Қылмыстық топқа қатысым жоқ” дейді. Талғарда не болды? Халық сене ме?
09:25
Демократиялы Қазақстан / Демократический Казахстан
Рет қаралды 325 М.