How to Perform a Misconnect Test on 880 Series Delta | QSA Global, Inc.

  Рет қаралды 6,743

QSA Global, Inc.

QSA Global, Inc.

Күн бұрын

Inspection and maintenance of your SENTINEL 880 Source Projectors is key to ensure your safety and the longevity of your device. Theo Ewing, from the QSA Global, Inc. Baton Rouge Service Center, explains how to properly perform a misconnect test on the SENTINEL 880 Series Delta Gamma-Ray Source Projector. This quick and simple misconnect test should be performed on a quarterly basis or any time you have a change in controls or projectors.
With over 12,000 in service worldwide from Alaska’s North Slope to harsh Middle East desert environments, QSA Global, Inc.'s SENTINEL 880 Series has nearly two decades of proven reliability and durability giving you the most uptime from your equipment and maximum production for your clients.
The versatility in using Ir-192, Se-75, and Yb-169 radioisotope sources maximizes the non-destructive testing applications where you can utilize your SENTINEL 880 Series projector while advanced safety features minimize operator dose.
Designed, tested, and manufactured to the requirements of ANSI N432-1980, ISO 3999:2004(E), IAEA TS-R-1 (2009), IAEA SSR-6 (2012), USNRC 10CFR34, USNRC 10CFR71, and USDOT 49CFR173.
► Learn more about the SENTINEL 880 Series: www.qsa-global...
► We'd love to hear your thoughts. Drop us a comment to let us know how we can support you and your team with QSA Global, Inc.'s SENTINEL 880 Series Gamma-Ray Source Projectors.
►Subscribe to our channel for more tips and techniques using QSA Global, Inc.'s gamma radiography source projectors and industrial isotopes.
#qsaglobal #880series #delta #oilgas #pipeline #inspection #ndt

Пікірлер: 4
ASNT 2020 Daily Inspection Showcase
24:43
QSA Global, Inc.
Рет қаралды 7 М.
The FASTEST way to PASS SNACKS! #shorts #mingweirocks
00:36
mingweirocks
Рет қаралды 16 МЛН
Bike vs Super Bike Fast Challenge
00:30
Russo
Рет қаралды 23 МЛН
Emergencias en gammagrafía industrial
16:40
Consejo Seguridad Nuclear
Рет қаралды 19 М.
How to Change the 1075 SCARPro from Projection to Contact Configuration
6:06
KD-CHECK: Dye Penetrant Testing on Welds
3:54
NDTChannel
Рет қаралды 145 М.
TechCorr- Real-time Radiography (RTR) for Pipeline Weld Inspection
4:26
ASNT 2020 Leak Test Breakout
9:54
QSA Global, Inc.
Рет қаралды 1,3 М.
Introduction to Radiography with both X and Gamma Radiaton
3:31
loading (Ir-192) from container to projector 880
16:09
HAMZA ABOU HASSANIN
Рет қаралды 5 М.