Beautiful elegant presentation. I have watched this one many times.
@svijaykumarreddy12423 жыл бұрын
Excellent demonstration of DK CRUSH
@SantanuDas-jt7jr7 ай бұрын
Initial crush is not done with wire in side branch. All gears should be removed from side branch before sb stent crushing. This demonstration would send a wrong message.please note.
@mohamedkishkt36678 жыл бұрын
After my warm greeting to you professor... Thank you very much..
@volskiv7 жыл бұрын
Dr Brilakis' book is extremely useful and now also having these videos is truly amazing
@JohnB-20215 жыл бұрын
What was the diameter of this diagonal ?
@jandenkmann67912 жыл бұрын
Thank you Dr. Brilakis. Do you perform a POT of the MV after MB stenting and before 2nd SB re-wiring? I don't see this step in the video, but it is listed in the word document. Thank you.
@matheuscsmed Жыл бұрын
Thank you, Matheus Silva
@zemos7776 жыл бұрын
Thanks for the illustrative case. I have a couple of questions: 1) do we have to cross through the proximal strut during the 1st kiss for optimal SB scaffolding? And regarding the second kiss (after MB stenting) do we cross from the distal stent strut as usual in any Bifurcation or cross from the proximal strut again? 2) Regarding the jailed SB wire after the crush, is it better to remove it before crushing the stent to avoid entrapment, especially that I had never had a problem to rewire the SB after the crushing of it's stent? Thanks alot for ur videos and for ur CTO book..... Really helpful
@manosbrilakis6 жыл бұрын
From the proximal strut on both occasions. This is different from the distal strut wiring used in most provisional stenting for kissing balloon inflation. Rewiring the SB from the distal MV stent cell could increase the possibility of the wire going between the stent and the vessel wall, which will leave a gap at the ostium after balloon crushing. For more information look at: Zhang J-J, Chen S-L. Classic crush and DK crush stenting techniques. EuroIntervention 2015;11:V102-V105.
@heekong2 жыл бұрын
@@manosbrilakis Thank you Dr. Brilakis. Just wanted to confirm with you again regarding rewiring through proximal/distal stent struts. Your Manual of PCI says the first rewiring should be through the proximal stent strut (no question about this). For second rewiring, should not it through the distal stent strut? Which is similar to rewiring after any POTS? Your book says the second rewiring should be through distal stent strut. Thank you again.
@zadigbalaban835911 ай бұрын
All Rewiring by all Crush Techniks should done from proximal Stent Struts, because you don't need to scaffolding the side branch, you have already in all Crush Techniks Stent over there in side branch.
@tuanhoanh11986 жыл бұрын
I used to hear that the outer layer of a polymer-jacket wire has the risk to be torn and gets stuck inside the vessel if we use it for jailing SB therefore we should avoid this kind of wire. But you prefer it. can you explain more?
@manosbrilakis6 жыл бұрын
See the following paper that makes an argument in favor of polymer-jacketed wires: interventions.onlinejacc.org/content/jint/9/18/1917.full.pdf
@konstantinschwarz15256 жыл бұрын
Excellent video. However traditional DK crush technique teaching warns against jailing the SB wire, both at time of crushing the SB stent and at time of MV vessel stent deployment. Entrapment risk of wire between two layers of metal may not be insignificant.
@manosbrilakis6 жыл бұрын
Excellent point: there is a risk of wire entrapment vs the risk of not being able to rewire the branch. One has to decide which risk is higher in each case. I personally jail the SB wire in nearly all cases. Thanks, Manos
@manosbrilakis6 жыл бұрын
You are right that jailing a wire always carries a risk for entrapment. At the same time jailing a wire facilitates rewiring and can allow advancement of a balloon if the side branch becomes occluded after stenting the main branch. Also polymer-jacketed guidewires are less likely to be entrapped. Weighing the risks/benefits is key for making a decision whether to jail a wire or not in each case.
@grjvlk6 жыл бұрын
Thank you for a detailed account of the technique. During kissing inflations is it necessary in Your opinion to use NC baloons? How can "braiding" of the guidewires be avoided during rewiring?
@manosbrilakis6 жыл бұрын
NC balloons allow you to go to higher pressure - on the other hand compliant balloons are more deliverable. You can use either depending on the specifics of the case. One way to avoid "twisting" of the wires is to use a dual lumen microcatheter, such as the TwinPass. Alternatively one can try to minimize wire rotation during insertion.
@grjvlk6 жыл бұрын
Manos Brilakis So, you believe it is OK to do a final kiss with semi-compliant baloons or should one always try to deliver 2 NC baloons for KD? Myself find it often a good enough result with a semi- compliant baloon in the side branch.
@manosbrilakis6 жыл бұрын
Agree - compliant balloons can work pretty well in most cases.
@ashwinigmc6 жыл бұрын
Thank you for this educational video. What do you think about risk of wire entrapment especially after deploying the main vessel stent? Did it ever happen to you during during DK crush?
@manosbrilakis6 жыл бұрын
Thanks for a great question. It has not happened to me during DK crush but can certainly happen. I still jail the SB wire during bifurcation stenting, but do the following: (a) prefer jailing polymer-jacketed guidewires that may be less likely to get trapped; (b) if the wire does not come back easily I advance a microcatheter or balloon as far as possible and then attempt withdrawing again.
@MinorityDoc5 жыл бұрын
@@manosbrilakis sir, why don't we remove the SB wire while deploying the MV stent? Is it just to make the wire act like a marker for the SB ostium?
@AliAbbas-sb3gi2 жыл бұрын
Yes we had it once trapped and we withdrew with a balloon assistant.
@drhmalhotra994 жыл бұрын
EXCELLENT------------- DR HEMANT
@cchung10982 жыл бұрын
GOOD TEACHING
@HoaBui-zc9ys6 жыл бұрын
Thank you for sharing this video. Can you help me: Why do we have to rewire side branch before the first kissing?
@manosbrilakis6 жыл бұрын
Because otherwise you would just re-expand the stent you just placed! The goal is to "crush" the part of the stent protruding into the main vessel and expand the struts at the side branch ostium.
@tuanhoanh11986 жыл бұрын
is it deemed culotte is easier than DK Crush to perform? when will you prefer Culotte?
@manosbrilakis6 жыл бұрын
I personally do not use culotte - I prefer DK crush given better supporting data, even though is is technically a little more complex.
@tuanhoanh11986 жыл бұрын
i usually find it tough to rewire after stenting SB when applying DK Crush, do we have any other way to overcome this along with filder FC wire and Twinpass?
@manosbrilakis6 жыл бұрын
1. I leave jailed wire in place as marker of position of SB. 2. Polymer-jacketed and TwinPass as you suggested. 3. Angulated microcatheter, like Supercross 120 and Venture. 4. Blocking balloon technique (balloon inflated transiently in main branch to prevent wire from prolapsing into the main branch.
@ahmedsabbar90495 жыл бұрын
Please did you have Vedio for TAP technique, thank u very much .
@manosbrilakis5 жыл бұрын
I am sorry, I very rarely do tap and do not have a video on it.
@ahmedsabbar90495 жыл бұрын
@@manosbrilakis Thank you Sir.
@jomonvarghesejomon92204 жыл бұрын
Good Result .
@minhtrungtran81314 жыл бұрын
Thank you
@svijaykumarreddy12423 жыл бұрын
DK CRUSH is superior to culotte DK CRUSH3 RESULTS Culotte needs vessels of similar diameter. Excellent demonstration of DK CRUSH BY BRILAKIS.