Thanks..! I know you just want to get the job done...but for you to take the time and help others....well that right there shows you are a ''Class Act'' very rare these days.......
@Lifes_Apprentice3 ай бұрын
Thanks!
@Mr76522 Жыл бұрын
Thank you for this video. It really helped me.
@brianstarkey1824 Жыл бұрын
Thanks for the video I am doing this for the first time today on my own roof. This answers a lot of questions I had on how to attack these exhaust vents. I like the ice and water shield idea I’m also going to do that on mine.
@Lifes_Apprentice Жыл бұрын
Happy to help
@Oneklickmedia Жыл бұрын
Same I did temp patch but I want to replace that vent and Re shingle . This help
@michaelirizarry38312 жыл бұрын
That’s the proper way to do it, a lot of roof leak with time because they only use caulking to keep water away but u need to keep in mind that caulking shrinks
@Lh-dq2zc2 жыл бұрын
"the way this one landed is kind of goofy" thanks for making me laugh 🤣🤣 cool video
@Lifes_Apprentice2 жыл бұрын
No problem!
@patrickpeterman8736 Жыл бұрын
WHAT SEALANT DID YOU USE AROUND THE STORM COLLAR?? A FURNACE FLEU PIPE CAN GET HOT; SOME SPECIAL HEAT RESISTANT SEALANT; GREAT VIDEO,S LEARNING AND LEARNING MORE THANKS PJP SORRY ABOUT THE CAPS !! KEY BOARD IS MESSED UP!!
@brianpanks5846 Жыл бұрын
You should have added a scrap piece in that row above that exhaust pipe and then ran a full shingle to cover that pipe flash. There should never be a seam on top of that flashing for that exhaust pipe,that seam should have been moved to one side or the other of that exhaust flange 💯💯
@Lifes_Apprentice Жыл бұрын
how is it wrong to have a keyway above a flashing? what if you have a 4 foot boot? You gonna make special shingles so you dont have a keyway above it? lol your trolling bro If you think that you have not done much roofing because there are so many situations you do not have a choice. large chimneys rubber roof tie ins etc
@jonnybegood142 ай бұрын
Right on. Thank you
@wrightsrrt8717 ай бұрын
I like the snow and ice membrane trick I'm use to using calking as well but ill be doing it that way from now on seems easy enough!! Thanks
@robbieklein61627 ай бұрын
Really helpful, man thanks!
@markbons77669 ай бұрын
10:08 he says "not to go through then metal" (vent flashing) . He nails into the flashing. No big deal if you put roofing cement on the nail heads(?)..
@JDCBenitez4 ай бұрын
Like it
@andrewtorres90812 жыл бұрын
Instead of leaving that seam there I would of ran the other side of those steps up until before that shingle that had a seam and then used a smaller shingle on that top course and then a full shingle next so then there is no seam . 👍🏽
@henryhofschneider471 Жыл бұрын
Righty goin Lefty
@richardmitton41155 ай бұрын
Yup, somebody else noticed that too!
@NWIVeteranConstruction3 жыл бұрын
Great video! Good enough for who it's for lol
@Lifes_Apprentice3 жыл бұрын
You got that right!
@hhprogressiveconstruction11403 жыл бұрын
It won’t hurt adding that weather watch but honestly must leaks come from those galvanized pipes rusting on collar or boot . Those shingles covering around are just as good since the shingles seal themselves . Hopefully you got the dumpsters business to provide disposal of the old shingles .
@Lifes_Apprentice3 жыл бұрын
we were in indiana filming with another youtuber so we were using his dump trailer
@joerobijr Жыл бұрын
Great content man! Is there a reason for putting the ice and water shield on last?
@Lifes_Apprentice Жыл бұрын
The reason we put it on last is just for water flow. If water was to get in it would run over water shield and onto metal or lower courses of shingles
@jamesscheidt4278 Жыл бұрын
Hey, great videos, but I wanted to caution that most codes will require a minimum of 1" clearance from combustibles. It looks like you shoved the flue into the roof sheathing.
@awac45773 жыл бұрын
I'm just curious but is that underlayment or weather shield directly beneath the pipe flange (prior to the shingles)? How was that applied? Looks like one, continuous piece in the video. In any case, thank you for the video. Very helpful as I need to do the same thing on my roof around a chimney pipe (except the roof is on already).
@Lifes_Apprentice3 жыл бұрын
we installed 2 continuous rows of ice and water at bottom of roof. that is why. it is not neccessary to have ice and water under or over
@danahasson28923 жыл бұрын
Justin you might turn me into a roofer, nah I will just stick to the tear offer.
@Lifes_Apprentice3 жыл бұрын
the tearoff is definitely roofing!
@danahasson28923 жыл бұрын
@@Lifes_Apprentice see what you did to me. Lol
@tysoncarpenter86286 ай бұрын
Yup always we use ice and water around a pipe awesome. his way is definitely the correct way lol
@Lifes_Apprentice6 ай бұрын
I do not think it is completely necessary and is time consuming but it could stop a leak from a shitty job
@richardmckrell4899Ай бұрын
The top ice and water should be adhered to the sheathing and then covered with the underlayment. He doesn't understand what the ice and water above the vent is for.
@dbarr82612 жыл бұрын
What I do if the shingle edge falls so close to the edge of the flashing is cut a short one about 18" and then run a full one just so a seem doesn't line up so close to the edge of the flashing.
@Lifes_Apprentice2 жыл бұрын
add a shingle about 12 inches and then a full one but be careful with your nail spacing so you dont have nails in keyway. or just caulk the edge or seam of shingle
@Brandon-no3vc Жыл бұрын
No tar underneath the metal?
@maciemoon8776 Жыл бұрын
Do you ever come to georgia?
@TractorMonkeywithJL9 ай бұрын
Dang, you must have some tough knees if you can wear shorts on a roof.
@ar2632 Жыл бұрын
Hey, your explanation is much better than other KZbinrs on why we're shingle in such a way, will you please share that nailer model?
@DOPE_SESH Жыл бұрын
Awesome vid, many ways to skin a cat type deal. Whatever works best for you. Nothing bad to say and this isn’t a rant of some sort, but why are you nailing left handed when your right handed? Lol maybe a leftie started it idk just curious.