How to test 3-Phase motor winding insulation

  Рет қаралды 4,254

LifeOfEngineering

LifeOfEngineering

Күн бұрын

MEGGER Meter # Fluke insulation multimeter
3-Phase motor winding insulation test
Fluke 1587 FC insulation multimeter
Check motor winding insulation is good or bad with help of meter.
Let me know if you want to know on any other topic let me know in the comments.
Please Subscribe to LifeOfEngineering for more videos and Tutorials.

Пікірлер: 10
@mcdonnellsinc
@mcdonnellsinc Ай бұрын
can you please tell the 3.1k viewers the name of your business, so we can avoid having you "troubleshoot" and misdiagnose our equipment 😅
@DallasAutoDiag
@DallasAutoDiag 3 ай бұрын
As far as i know a 3 phase motor windings are not suppose to have any continuity between any given 2 phases. just like between any given phase and the motor case. in your testing when there was 0 resistance between 2 phases on motor 1 you said "this is good" which is actually not. and the opposite happened on motor 2. in addition, you were suppose to hole the test button for a minimum of 60 seconds to see if there is any drop in the resistance. in short, Hi resistance=good, Low resistance or a 0v reading=bad.
@LifeOfEngineering-dm7fk
@LifeOfEngineering-dm7fk 3 ай бұрын
Thnak you so much for your response I will make sure that I will provided you right information but Thank you.
@bobbauvian7700
@bobbauvian7700 2 ай бұрын
if phase wires are not connected in a 3 ph motor, how will the motor run then? I think may be we all need to learn more.....
@Josh-px6xb
@Josh-px6xb 2 күн бұрын
3 phase motor windings WILL have a resistance reading between the windings . If it didn’t that mean it would be a bad motor. All the windings are tied together
@bobbauvian7700
@bobbauvian7700 15 сағат бұрын
Oh OK I got it. not sure if I am correct. but in the motor electric box, where all the wires are. if everything is disconnected then the windings are not connected. correct?
@Josh-px6xb
@Josh-px6xb 3 сағат бұрын
@@bobbauvian7700 dual voltage motors won’t be connected for an example . (If you have a 9 lead motor)
@amandeepchahal007
@amandeepchahal007 5 ай бұрын
Good job 👍
@richardlang2185
@richardlang2185 11 күн бұрын
This video is incorrect how to use this FLUKE tester and incorrect how to test motor for Insulation Resistance. Insulation Resistance on motor is done by Polarisation Index PI what this FLUKE tester provides.
@argelgus
@argelgus Ай бұрын
No No No
3 PHASE MOTOR TESTING - how too PROPERLY
39:04
Actual Electrical Content with Jamie blatant
Рет қаралды 36 М.
Fluke 1587 FC - Fluke Fridays - Episode 20
6:18
Fridays With Brandon
Рет қаралды 32 М.
Watermelon magic box! #shorts by Leisi Crazy
00:20
Leisi Crazy
Рет қаралды 76 МЛН
когда не обедаешь в школе // EVA mash
00:51
EVA mash
Рет қаралды 3,9 МЛН
小天使和小丑太会演了!#小丑#天使#家庭#搞笑
00:25
家庭搞笑日记
Рет қаралды 42 МЛН
How to perform a “Loss of Insulation” test using a Fluke 1587FC
10:52
Ms.A The Shop Teacher
Рет қаралды 131 М.
What goes on inside a Mitsubishi branch controller?
13:03
VrfMadness
Рет қаралды 23 М.
#64 - What is a Ghost Voltage?  Fluke 116 LoZ Demonstration.
9:57
The Tech Circuit
Рет қаралды 9 М.
Motor testing with a Megger MIT230
7:38
Mechanntraining
Рет қаралды 111 М.
Checking Windings in a 9 Lead 3 Phase Motor
7:55
AmateurHour
Рет қаралды 296 М.
FLUKE 1587 FC Insulation Tester  vs. FLUKE 1520 Megohmmeter (Comparison)
11:25
The Electricians Tools (Review) Channel
Рет қаралды 2,2 М.
Using the FLUKE 1507 to Identify a bad motor.
3:18
WTF Man!
Рет қаралды 116 М.
How to check your  Electrical motor winding - Continuity & Insulation resistance test
15:43
Maintenance Engineering Insider
Рет қаралды 234 М.