Can't see the settings on the multimeter or where the leads are plugged in. To be helpful to beginners this would be essential. Also cannot tell what prongs on the piggy back plug you are referring to. Thank you for the video prompting further research.
@sassczar17602 ай бұрын
he put it in the lower flat prong and the lower slot on the back side.
@kozmikkev4742 жыл бұрын
Hold that plug so we can see the holes, man I have no idea which prong you are talking about holding it sideways. large prong,small prong or round prong, why not identify it....useless video
@LygerTheCLawАй бұрын
this test doesnt prove either can carry the needed current or that an old float switch has been compromised by arcing. i have a float that tests fine like this, but it won't turn on my sump pump, it's about 2 years old and sees thousands of cycles a year. i can jiggle the float and the pump will turn on, but these often time fail when using 10a or more in current(their upper limits are usually 10-15amps) the bigger your pump is, the shorter their life is, better to convert this to a low amp relay switch at that point.
@igotadose4 жыл бұрын
Might want to show the test lead config on the piggyback switch before testing, you couldn't really clearly see which plug outlet you plugged into.
@Jack-Surreal_Panes2 ай бұрын
Tested mine. I had nothing down but resistance up. I Second float, nothing up or down. Pump float low reading down but when up, I high.
@travisleddy68872 жыл бұрын
Exactly what I needed. Thank you.
@RCworstwater2 жыл бұрын
Glad it helped!
@captainjazzbo83685 ай бұрын
Hi. My alarm in on but the water isn't touching the alarm float. Please help.
@Punny1234Ай бұрын
I think he had the meter hooked on to the hot prong and not the neutral one.
@robtheisen58445 жыл бұрын
Great video! Show us plumbers how to dust off the old Multimeter and put it to good use! Keep the videos coming!
@RCworstwater5 жыл бұрын
We've got two more multimeter videos coming out next! :)
@erinjohnson9873 Жыл бұрын
Total newb here… but is the float inside the septic tank? How do I get at it? Do I actually have to climb inside the tank? 😮
@christinemarkley4 жыл бұрын
Very helpful, thank you! Is replacing the float switch something a DIYer could do?
@RCworstwater4 жыл бұрын
Yes, absolutely!
@richardsatterfield42223 ай бұрын
Where do u set it on the ohm meter
@natetolbert36714 жыл бұрын
Pro tip: If you do dot have access to a multimeter, a test light should work just as well.
@RCworstwater4 жыл бұрын
Good Tip!
@ElonMuskX2 жыл бұрын
What about a power bleed problem in the float. Mine test great but down is send some power through . Does the float need to match the motor HP???
@andymclemore61939 ай бұрын
Wish I could see which holes you were plugging into, if so it would be a great video
@linuxcaffe5 жыл бұрын
.. words .. :) keepit up! I enjoy / learn from yer vids, thanks
@RCworstwater5 жыл бұрын
Thanks for watching!
@BenjaminMaciel21000 Жыл бұрын
Mine is backwards right now. I just plugged it into the contactor and When I flip my pump switch is up-- its turning on. And when I turn it down-- its off. Any ideas?
@RCworstwater Жыл бұрын
Sounds like you have a normally closed float or contactor.
@MrRuss582 жыл бұрын
when my i move my up inside tank it trip the gfci..any idea ?
@functionalvanconversion42842 жыл бұрын
The breaker at the house subpanel was left off causing a high level water alarm to be triggered (when the tank overfilled). I manually turned the pump on and then tested all three floats, but for some reason the on/off float won't turn on the pump. I tested it for continuity and it works when flipped (it's only 1 year old along with pump and all floats). I tested the switch as well and it works. Any ideas? Thx
@JonnyA3652 жыл бұрын
Could've gotten the connections wet when tank overfilled maybe a short in pump wire
@functionalvanconversion42842 жыл бұрын
@@JonnyA365 when I lift the on/off float with a hook it sets off my ohms meter (reads continuity). Low level float and high level float still set off the alarm when I lift them with a hook as well. The pump also runs manually. Do you still think there could be a short in this case? If so I'll take the wire junction box apart as I am testing from the control box.
@TheAngelin20004 жыл бұрын
I'm glad i got to see this. i see this test. 1 was doing the wrong way wrong way
@maramacs12544 жыл бұрын
Hi, thanks for the video. I have a problem with the solanoid float system for a solar hotwater system not responding and suspecting the float switch. There is a voltage running through the float switch whether the float is up or down the magnet shaft in one orientation, but if I turn the float around then there is no voltage through the switch whether the float is up or down the shaft. Does this mean there is a problem with it and if so can I fix it or do I need to get another one? Thanks heaps.
@RCworstwater4 жыл бұрын
Please give us a call for help troubleshooting: 855.329.4519
@jorgemac2115 жыл бұрын
I have 3 floats, 2 to control pump and one is the alarm. which type I should get in regards of amperage and if the 3 floats are normally open? tks
@RCworstwater5 жыл бұрын
That depends on your pump's amperage. Give our experts a call: 855.329.4519
@556nutt Жыл бұрын
Kinda figured that was how to test one but your video was helpful to see it. Thanks
@RCworstwater Жыл бұрын
Glad it helped
@JamesSathre4 жыл бұрын
Thanks for making this video! I was able to test my own float switches at home after watching it. All were working perfectly, but I didn't know anything about float switches before this video.