Рет қаралды 101,418
bit.ly/2O03vEX
In this video, our automotive program manager here at Fluke will demonstrate how to test a rear window defroster/defogger grid with The Fluke 233 Remote Display Digital Multimeter.
The Fluke 233 Remote Display Digital Multimeter features a removable display, giving you the flexibility to take measurements up to 10 meters (33ft) away from the Fluke 233.
To test a rear window defroster grid, connect the leads to the defroster/defogger grid, turn the key on and check the wireless display to determine whether there's voltage coming from the rear window defroster/defogger grid. Be sure that the Fluke 233 is measuring DC volts.
If voltage is present, next is to test the resistance emitted from the rear window defroster/defogger grid in each location. Thle Fluke 233 Remote Display Digital Multimeter comes with flexible back probe pins. Use the back probe pins to measure resistance of the entire grid and check if there's a loose connection in the any part of the defroster/defogger grid.
To learn more about the 233 Remote Display Multimeter, visit the Fluke website: bit.ly/2O03vEX