In this video I show you how to use a process meter to source or simulate 4- 20 mA using a fluke 789 process meter on Instrumentation loops.
I also talk about the different modes and how to determine the setup of aa current loop.
In this video, I’m going to show you an easy to follow 5 step guide to using a fluke 789 process meter - for sourcing or simulating 4-20mA loops, perfect for a whole host of instrumentation calibration and fault finding needs.
Quickly, before we move onto to the steps on how to use the fluke 789. we should discuss the difference between sourcing and simulate modes.
Transmitters and other sensors that give 4-20mA signals are connected to a plc or other input device that reads the current within the loop. These current loops are usually 24v DC powered.
These Instrumentation loops can be either have the 24Vs powered from the input card or the transmitter is externally powered and it provides the 24Vs for the loop power.
When using a process meter in place of transmitter to test a loop you will need to use it in a different mode depending on what is powering the loop.
If the transmitter was supplying the loop power, you’ll need to source the loop.
If the input card or isolator is powering the loop, you’ll need to simulate the loop.
Lets now lets look at the steps you’ll need to source or simulate, afterwards I’ll go through a few tips how to identify how a 4-20mA loop is setup so you will know what mode to use.
Remember electricity is dangerous, so only work on equipment you are competent to do so! And always check the voltages you are working with.
▶▶Check out brilliant T-shirts / Merch at my store:
www.redbubble....
▶▶Check out my website for more articles on Instrumentation:
www.instrument...
▶▶ Amazon Affiliate link to Fluke 789 - amzn.to/3fhDQWj
▶▶ Fluke 117 guide for voltage and resistance operation modes - • How to Use a Fluke Mul...

Пікірлер: 51
@kenyattafrazier
@kenyattafrazier 2 жыл бұрын
I just started an apprenticeship in which I thought I’d be doing nothing but electrical work but instrumentation is a huge huge part of what we do. I came from a commercial and residential background so this industrial stuff is so new to me. So much to learn about these instruments it seems
@MarioPena-q6y
@MarioPena-q6y Жыл бұрын
Same! I come from industrial work I went from 5 year electrical apprentice to 1st year automation totally different language!
@jonathancoker9916
@jonathancoker9916 3 ай бұрын
Same again lol. I went from an electrical job to an instrumentation job. I thought I would be doing some electrical still as an instrument tech but that was not true at all and I have to learn a lot about instrumentation lol. These videos help a lot!
@anoopr-c6e
@anoopr-c6e 2 ай бұрын
kzbin.info/www/bejne/rnq2inavqrhqmqcsi=IdVe8MM1oC0yTUox
@karaouilaredj4737
@karaouilaredj4737 4 жыл бұрын
No music Clear Simple And no much talk. 👍
@InstrumentationControl
@InstrumentationControl 4 жыл бұрын
Glad you enjoy the video and hope you found it useful, hopefully you subscribed :)
@anoopr-c6e
@anoopr-c6e 2 ай бұрын
kzbin.info/www/bejne/rnq2inavqrhqmqcsi=IdVe8MM1oC0yTUox
@InstrumentationControl
@InstrumentationControl 4 жыл бұрын
If you need one of the best Process Meters on the market check out the price of the Fluke 789 here on Amazon! - amzn.to/3fhDQWj ▶▶Check out brilliant T-shirts / Merch at my store: www.redbubble.com/people/rudd4y/shop?asc=u ▶▶Check out my website for more articles on Instrumentation: www.instrumentationcontrol.info/articles
@leef2267
@leef2267 4 жыл бұрын
Another useful & informative video. Keep up the nice work!
@InstrumentationControl
@InstrumentationControl 4 жыл бұрын
Thanks Lee. Glad you enjoy!
@iamsupercoolish
@iamsupercoolish 2 жыл бұрын
This is excellent! Thank you for this.
@InstrumentationControl
@InstrumentationControl 2 жыл бұрын
You're very welcome!
@kevin00861
@kevin00861 2 жыл бұрын
Wooow, thanks a million times, that was very explanatory, simple and straight to the point
@anoopr-c6e
@anoopr-c6e 2 ай бұрын
kzbin.info/www/bejne/rnq2inavqrhqmqcsi=IdVe8MM1oC0yTUox
@vladislavkorolkov8957
@vladislavkorolkov8957 Жыл бұрын
Great and informative review👍
@ariesmanaois7499
@ariesmanaois7499 2 жыл бұрын
Thanks for the useful information.
@InstrumentationControl
@InstrumentationControl 2 жыл бұрын
Glad it was helpful!
@mdmclaughlin28
@mdmclaughlin28 4 жыл бұрын
Could you do a tutorial using a Hart 475 with a Fluke simulator and press pump to do loop tests/simulations and calibrations on Rosemount flow, pressure, level and temp?
@anoopr-c6e
@anoopr-c6e 2 ай бұрын
kzbin.info/www/bejne/rnq2inavqrhqmqcsi=IdVe8MM1oC0yTUox
@jcbervan7598
@jcbervan7598 2 жыл бұрын
Very useful
@InstrumentationControl
@InstrumentationControl Жыл бұрын
Glad you think so!
@fltp1888
@fltp1888 3 жыл бұрын
Hi Bro, may I know what is the software you use to produce all this fantastic videos? Your videos are wonderful and full of values. Thanks.
@InstrumentationControl
@InstrumentationControl 3 жыл бұрын
Hi there. Thanks for your kind words. The software is called video scribe.
@fltp1888
@fltp1888 3 жыл бұрын
@@InstrumentationControl It must be very time consuming and taxing to produce videos like this...tough job but you do an amazing task. Thanks a lot
@joshuasoberanes5441
@joshuasoberanes5441 2 жыл бұрын
Any videos for using a hart 475?
@anoopr-c6e
@anoopr-c6e 2 ай бұрын
kzbin.info/www/bejne/rnq2inavqrhqmqcsi=IdVe8MM1oC0yTUox
@solstar3461
@solstar3461 4 жыл бұрын
Muy buen video. Saludos!!!!
@mauricethegecko9700
@mauricethegecko9700 2 жыл бұрын
Can this meter source/simulate 0-10vdc control loop systems? Does it have a 250 or 500 ohm resistor in it? 250 0-5vdc or 500 0-10vdc?
@InstrumentationControl
@InstrumentationControl 2 жыл бұрын
Hi there, this meter will only source mA. Of course if you can use an external 250 / 500 ohm resistor with this meter for your voltage inputs.
@BoandBeceadventures
@BoandBeceadventures 3 жыл бұрын
Thanks I’m trying to decide on a new meter. What’s the main differences between the 789 and 117 mentioned here please?
@InstrumentationControl
@InstrumentationControl 3 жыл бұрын
Hi James, The 789 will allow you to source and simulate 4-20mA current loops, if you work with industrial instrumentation then its the best version to go for. If you don't need that functionality then save yourself some money and go for the 117. If you do decide on either option please consider using my affiliate link in the description to amazon. It won't cost you anymore and helps my channel out :)
@BoandBeceadventures
@BoandBeceadventures 3 жыл бұрын
@@InstrumentationControl I’ll gladly support you. However I think I need one somewhere in the middle. Can you recommend one that can simply read 4-20mA and do you have a video on how to do so?
@InstrumentationControl
@InstrumentationControl 3 жыл бұрын
​@@BoandBeceadventures It sounds like the Fluke 179 would be ideal for you James, it reads down to 0.01 mA on DC loops. Here's a link for you to use (my affiliate) amzn.to/3bYFfzF as for how to take a mA measurement if you look at my fluke 117 video there is a section for measuring mA, Its the same with the 179 only you have more resolution. The 117 only reads down to 0.001 Amps or 1 mA. No good for 4-20 loops. Hope this helps!
@BoandBeceadventures
@BoandBeceadventures 3 жыл бұрын
@@InstrumentationControl thank you I will look first thing tomorrow morning and if I do purchase I will definitely use your link. Thank you again
@BoandBeceadventures
@BoandBeceadventures 3 жыл бұрын
@@InstrumentationControl what do you think about this one and do you have a link for it Fluke 87V/IMSK Industrial Digital Multimeter with Fluke i400 Clamp Meter Combo Kit
@angelstain4365
@angelstain4365 2 жыл бұрын
I've been a Industrial electrician for about 9 years but want to jump to being a instrument tech.. how can I start about that ?
@carmemories4202
@carmemories4202 2 жыл бұрын
Find a company looking to train a new instrumentation tech (hard) Or go to school (easy but expensive)
@uzairasif2475
@uzairasif2475 3 жыл бұрын
Sir can we connect single 4-20 ma to 2 sources?(i mean from single 4-20ma can we run 2things?)
@InstrumentationControl
@InstrumentationControl 3 жыл бұрын
Hi there, Yes we can have multiple devices in a single 4-20mA loop. A common use case is a field transmitter with a local digital display within the loop that is displaying the 4-20 the transmitter is controlling as well being connected to the control system for remote indication.
@ebbyt00
@ebbyt00 4 жыл бұрын
thanks alot
@InstrumentationControl
@InstrumentationControl 4 жыл бұрын
No problem, hope it helped!
@winstonli150
@winstonli150 26 күн бұрын
I think you can Not assume the lead resistance is 0.1 ohm, if that is the case then you need another assumption to cover that
@GorgeAndrade-jw6kl
@GorgeAndrade-jw6kl 3 ай бұрын
That transmitter is a Wireless WiHart device no 4-20mA source!
@Àhmåd-RM-143
@Àhmåd-RM-143 3 жыл бұрын
💜💜
@Trudeautthebestt
@Trudeautthebestt Жыл бұрын
BUT WHAT ABOUT THIS >>>...You must need to connect negative terminal of transmitter to 400 mA(red probe) terminal and common probe to negative terminal of power supply to measure mA value.
@Jay-fp8iy
@Jay-fp8iy 4 ай бұрын
This is literally the opposite of what fluke instructions say to do?
@anoopr-c6e
@anoopr-c6e 2 ай бұрын
kzbin.info/www/bejne/rnq2inavqrhqmqcsi=IdVe8MM1oC0yTUox
@crmags
@crmags 3 ай бұрын
This is NOT correct. Both Source and Simulate the dial remains on the Output mA setting, but the probes move between the 1st (from the left) and the 3rd. Loop power is used when you have a transmitter you want to verify is outputting the correct mA, but needs to be powered by the signal loop.
@anoopr-c6e
@anoopr-c6e 2 ай бұрын
kzbin.info/www/bejne/rnq2inavqrhqmqcsi=IdVe8MM1oC0yTUox
4-20 mA Current Loop - History, Why, Advantages, Disadvantages
14:52
Instrumentation Tools
Рет қаралды 187 М.
СИНИЙ ИНЕЙ УЖЕ ВЫШЕЛ!❄️
01:01
DO$HIK
Рет қаралды 3,3 МЛН
Episode 101   Fluke 789 Process Meter Mini Review
27:41
Closed account
Рет қаралды 63 М.
How to Use a Fluke Multimeter - Instrumentation Technician Course - lesson 4
14:19
Instrumentation & Control
Рет қаралды 116 М.
Calibration of rosemount 3144p pt1 thermocouple
17:16
byronvanalstine
Рет қаралды 136 М.
Common Instrumentation Faults - 4-20 mA Loops
7:17
Instrumentation & Control
Рет қаралды 37 М.
Instrumentation Calibration - [An Introduction]
5:42
Instrumentation & Control
Рет қаралды 194 М.
Troubleshooting a PLC Output
7:25
KletteTech
Рет қаралды 103 М.
DP Flow Transmitter Testing and Recalibration
8:24
RealPars
Рет қаралды 182 М.
СИНИЙ ИНЕЙ УЖЕ ВЫШЕЛ!❄️
01:01
DO$HIK
Рет қаралды 3,3 МЛН