No video

How to Use the Fluke Versiv Series Part 1: DSX-5000/8000 Cable Certifier

  Рет қаралды 184,860

Advanced Test Equipment Corp. (ATEC)

Advanced Test Equipment Corp. (ATEC)

Күн бұрын

Rent Fluke Versiv equipment here: www.atecorp.com...
The Fluke Versiv series brings the capability to test, certify, troubleshoot and analyzer the characteristics of wire-line networks, both fiber optic and copper. Part 1: Fluke Networks DSX-5000 setup, configuration, and testing of Cat 5e patch panels and patch chords. Data transfer and PC software also provided.
#FlukeVersiv #FlukeDSX5000 #FlukeDSX8000

Пікірлер: 45
@frankolwenda5128
@frankolwenda5128 2 жыл бұрын
Thanks for the video. I literally had to use this 30 minutes after watching the video It's been helpful
@AdvancedTestEquipmentCorp
@AdvancedTestEquipmentCorp 9 ай бұрын
Thank you, we are glad to hear!
@1967Affe
@1967Affe 7 жыл бұрын
Nice video. When testing patch cords you have to use special channel adapters! Current testing of cables requires special channel modules. A normal channel = test of link including 2 crosslink cables Patchcord modules: Cat5E cabling: DSX-PC5ES Cat6 cabling: DSX-PC6S Cat6A cabling: DSX-PC6AS Coaxial SET: DSX-COAX Coaxial cables: DSX-CHA003 M12 cables: DSX-CHA021S
@markmullins7195
@markmullins7195 6 жыл бұрын
The patch cord adapter should be used for testing patch cords. Channel adapters should not be used for testing patch cords.
@mrgoggles1963
@mrgoggles1963 4 жыл бұрын
Correct. Please see comment above, for details.
@rosevineargallon9351
@rosevineargallon9351 3 жыл бұрын
Thanks for this video,
@jeahmaeramirez5382
@jeahmaeramirez5382 3 жыл бұрын
Thanks BIT-CT 2I
@udhayakumar7345
@udhayakumar7345 3 жыл бұрын
Nice video
@sirajshaikh2982
@sirajshaikh2982 5 жыл бұрын
Good tested
@AdvancedTestEquipmentCorp
@AdvancedTestEquipmentCorp 5 жыл бұрын
Thanks. For more videos on the DSX model check out our Communications Testing playlist. kzbin.info/aero/PLx73HqE6bEC1E5K_-6iI-VoFDmWKEgoYB
@mrgoggles1963
@mrgoggles1963 4 жыл бұрын
Siraj: The video you have just watched was put up by someone who was not trained by Fluke, to properly operate their test equipment, much less teach about it. Please review comment above.
@Tmoney064
@Tmoney064 7 жыл бұрын
nice video short and sweet
@mrgoggles1963
@mrgoggles1963 4 жыл бұрын
Wrong!!! Please see note above.
@zachpangos7159
@zachpangos7159 5 жыл бұрын
Ummm, where is part 2 and so on?
@AdvancedTestEquipmentCorp
@AdvancedTestEquipmentCorp 5 жыл бұрын
Hi Zach, currently there is no part 2. We do however have a video on the features and benefits of the DSX Cable Analyzer Series: www.atecorp.com/home/blog/dec18/fluke-dsx-cable-analyzer-series If you really want to know more, we suggest speaking to our communications account manager to get more info. Cheers, #ClickRentTest
@mohammedmadani1255
@mohammedmadani1255 7 жыл бұрын
very usefull
@donaldoyier2618
@donaldoyier2618 7 жыл бұрын
Vertical
@babarrahmaan276
@babarrahmaan276 6 жыл бұрын
I neead tasting cat 7
@babarrahmaan276
@babarrahmaan276 6 жыл бұрын
Pliac sand cat7 tasting
@TH-hb1ct
@TH-hb1ct 6 жыл бұрын
Shouldn't you store your 2th permalink adapter as well?
@taperjim9695
@taperjim9695 4 жыл бұрын
@@babarrahmaan276 Sorry for the delay in answering, but this is a common question. In the ISO standard, they don't have Cat 7, they call it "Class F". If you select an ISO Class F test, that is the Cat 7 limits. Be careful, you will need Cat 7 connectors to pass the test.
@cidadaodomundo007
@cidadaodomundo007 5 жыл бұрын
How did you decide on the message that appeared on the screen? at 3:15 time of video? this message appeared to me and I do not know how to solve
@AdvancedTestEquipmentCorp
@AdvancedTestEquipmentCorp 5 жыл бұрын
Hello Miezi, we recommend speaking with the manufacturer. Here is their contact information: For technical support, call 1 (800) 283-5853 or visit www.flukenetworks.com/Support. Hope you find this helpful.
@eugenedunn8642
@eugenedunn8642 5 жыл бұрын
He set up his test as channel but he is using the permanent link adapters. You have to use the correct test limit with the cable type and adapters you are using or you will get error messages.
@mannyknowles2220
@mannyknowles2220 4 жыл бұрын
This is correct info.
@aronmartinez7977
@aronmartinez7977 3 жыл бұрын
When a data cable fails how you know what side it’s the problem at ? At the main or the remote ?
@AdvancedTestEquipmentCorp
@AdvancedTestEquipmentCorp Жыл бұрын
Hello! The test result will show you what the failure is and where it is along the cable. Whether at one of the connectors or some distance down the line, and exactly on which twisted pair the issue is occuring. Please feel free to contact ATEC for more information.
@markascott
@markascott 6 жыл бұрын
Thanks for the video. Are the steps about the same for the DSX 8000?
@taperjim9695
@taperjim9695 4 жыл бұрын
Yes, the only difference is that a DSX-8000 offers a Category 8 test, otherwise they are about the same.
@mrgoggles1963
@mrgoggles1963 4 жыл бұрын
No sir they are not. The steps in the video show how to NOT test properly, and they leave out significant and very important details. You can find tutorials and training videos at Fluke.com website. These will train you on how to properly use a DSX 8000 Versiv.
@mohamedfikry4612
@mohamedfikry4612 3 жыл бұрын
How to take the report from Fluke
@AdvancedTestEquipmentCorp
@AdvancedTestEquipmentCorp 9 ай бұрын
You can use the free Fluke Linkware software and download via a USB thumbdrive.
@aziemburhan5167
@aziemburhan5167 5 жыл бұрын
I have tested my cat5e using a same cable analyzer like yours. However, when i transfer the test result and open in laptop, the resistance result is shows N/A. It should have reading in ohm. Can u help me how tu get resistance result in test result
@taperjim9695
@taperjim9695 4 жыл бұрын
Is this an extremely short cable? That may be the cause. Another option would be to run a (+PoE) test.
@mrgoggles1963
@mrgoggles1963 4 жыл бұрын
Your test set up is not the proper one you need for what you are trying tomaccomplish. Please contact Fluke and arrange for proper training. It will do you good.
@jhayerz2k167
@jhayerz2k167 6 жыл бұрын
I'm having problems I'm testing cat 6 it's say wire map is bad
@johntabor2619
@johntabor2619 6 жыл бұрын
Was the wire certified or did you the the rj45s or jacks?
@mrgoggles1963
@mrgoggles1963 4 жыл бұрын
Bad wire map, means the termination quality is not as it should be. Pin out issues/ reversals/ opens/ shorts/. Examine the quality of the termination at the location point of testing and redo using proper tools and know how. Are you, or any member of your crew or staff, a certified NCS?
@balamurugan7366
@balamurugan7366 2 жыл бұрын
I want to buy second hand one Anybody is having please give your details
@AdvancedTestEquipmentCorp
@AdvancedTestEquipmentCorp 9 ай бұрын
Please feel free to reach out to us at www.atecorp.com
@randomvideos8472
@randomvideos8472 4 жыл бұрын
Which brand sir
@AdvancedTestEquipmentCorp
@AdvancedTestEquipmentCorp 9 ай бұрын
This is Fluke Networks.
@user-hy9ef1wu6l
@user-hy9ef1wu6l 5 ай бұрын
can i get any phone number
@AdvancedTestEquipmentCorp
@AdvancedTestEquipmentCorp 5 ай бұрын
8585586500 ask for Reda
Getting Started with the Fluke Networks DSX CableAnalyzer™
43:17
Mike Pennacchi
Рет қаралды 16 М.
Single fiber testing with the CertiFiber® Pro
7:37
FlukeNetworksSupport FNET
Рет қаралды 35 М.
Little brothers couldn't stay calm when they noticed a bin lorry #shorts
00:32
Fabiosa Best Lifehacks
Рет қаралды 19 МЛН
Ik Heb Aardbeien Gemaakt Van Kip🍓🐔😋
00:41
Cool Tool SHORTS Netherlands
Рет қаралды 9 МЛН
Smart Sigma Kid #funny #sigma #comedy
00:40
CRAZY GREAPA
Рет қаралды 40 МЛН
Happy birthday to you by Tsuriki Show
00:12
Tsuriki Show
Рет қаралды 11 МЛН
Running an OTDR test with the Fluke Networks OptiFiber™ Pro
15:40
Mike Pennacchi
Рет қаралды 17 М.
Fluke DSX5000 Basic Setup
6:32
SkillsBattles
Рет қаралды 1,3 М.
CertiFiber Pro OLTS Getting Started Video - Setup Part 1 By Fluke Networks
9:39
How to use a multimeter like a pro, the ultimate guide
12:55
James Gatlin
Рет қаралды 2 МЛН
Terminating/Testing Network Cables - CAT 3, CAT5, CAT6, CAT 7, CAT 8
25:42
Building a Cat6 test with the DSX CableAnalyzer™
6:20
Mike Pennacchi
Рет қаралды 11 М.
OptiFiber® Pro OTDR - Setup: By Fluke Networks
7:51
FlukeNetworksVideo
Рет қаралды 48 М.
Little brothers couldn't stay calm when they noticed a bin lorry #shorts
00:32
Fabiosa Best Lifehacks
Рет қаралды 19 МЛН