Hi, Dear All, Just a kind request to the viewers and professionals who can afford to sponsor or fund this channel, mainly for the benefit of the viewers all over the world.🌎🗺✈ It will also definitely be a motivation for me, to continue this channel with good explanatory educational videos for all of you. You can contribute by being a Sponsor of this channel using the following link, patreon.com/ElectroAcademy I made this request few months ago, and now we have one patron who has come forward to help this channel.💪💪 I love it from my bottom of heart. ❤❤❤ I know, generally entertainment channels get quite a lot patrons for their support, but look forward to see some more supporters who understand the value of an educational channel like this. Your kind gesture will be most welcome..!😍👍 Thanks and Best regards. Sudarshan, Creator of Electro Academy Channel.
@НиколаЂорђевић-х3м11 күн бұрын
One of the best tutorials I have ever watched. Thank you a lot for this great work.
@ElectroAcademyEA10 күн бұрын
Thank you
@Eduardo-mg7zm Жыл бұрын
💕 *Promo SM*
@ElectroAcademyEA Жыл бұрын
Thank you
@allanrodriguez1308 Жыл бұрын
I often encountered these safety relay often bypass because they say that it is hard to troubleshoot due to to many wirings, sensitivity and interlocks. That is why you need to know the importance and the purpose of thess safety relays and the consequences if you did bypassed it
@ElectroAcademyEA Жыл бұрын
Sure. Thank you
@juankiriluk58642 ай бұрын
Why do we need a Master Relay before the Magnetic contactor?
@sindicta5757 Жыл бұрын
I was looking for a vacuum replacement part and Amazon accidentally came up with safety relays and now I'm here. I'm not even an electrician, I'm an artist. Thanks for satisfying my curiosity
@ElectroAcademyEA Жыл бұрын
Thank you
@bonnylasu7665 Жыл бұрын
Hi Sir good day. Thank you very much for very nice teaching video of electrical installation.
@ElectroAcademyEA Жыл бұрын
Thank you
@michaelcostello699110 ай бұрын
S12 supplies 24 V to S34 to reset. Is s12 just looking at channel 1 ? Please advise.
@ElectroAcademyEA10 ай бұрын
S11-S12 and S21-S22 are input switches and must be in the closed position for internal contactors K1 and K2 to be closed. Contactors K1 and K2 (placed inside the safety relay) must be in the closed position for control power to be available at terminal 14. Although 24 volts for reset power have been connected from S12 of channel 1, the system cannot be restarted without channel 2 enabled. So, the motor run contactor control power will not be out from terminal 14, without closing both the S11-S12 and S21-S22 switches.
@michaelcostello699110 ай бұрын
@@ElectroAcademyEA Thank you very much for clarifying this. Please do more safety videos as there as so many different types of safety controllers in industry
@wyedelta962813 күн бұрын
@@ElectroAcademyEA why we need to ground s21
@user-ri8hd4bo8k11 ай бұрын
Emergency stop doesnt stop the circuit ?
@ElectroAcademyEA10 ай бұрын
If the motor running contactor has a contact welding condition, emergency stop cannot stop that faulty contactor from operating.
@raquelsapalaran2907 Жыл бұрын
one of the best video tutorial❤
@ElectroAcademyEA Жыл бұрын
Thank you
@healthinformationHI Жыл бұрын
Wow. Nicely explained 👌
@ElectroAcademyEA Жыл бұрын
Thank you
@xanime656611 ай бұрын
Thank you
@ElectroAcademyEA11 ай бұрын
Thank you
@mrtrader4628 Жыл бұрын
Very good please keep them coming
@ElectroAcademyEA Жыл бұрын
Thank you
@okonkwoandrew5880 Жыл бұрын
I can't finish my expression over the result of your videos i give and spend my time following and watching your videos. I wish to have a direct contact and connection with you guys for more. kudos