換MCB+RCBO+三相總制 | 屋企電力裝置潛在的危機...

  Рет қаралды 41,749

勤師傅-分享頻道Master Kan-Share Channel

勤師傅-分享頻道Master Kan-Share Channel

Күн бұрын

[工程|日常|分享|記錄]
👉有關家居 👉裝修 👉工程 👉維修 👉保養問題?
仲有記得 ~ 訂閱🔔(按全部🔔) ~ Like👍 ~ 分享📢 & 可以影片下方留個言交流下😁!!!
記住........按全部🔔先可以第一時間收睇到我們最新內容,多謝各位支持💪🙏!!
🤞請支持本地創作(廣東話)播放!!
👋歡迎瀏覽下方公司網頁或FB專頁連結留言✍
...................................................................................................................................
如想像進一步了解可以按下面公司網頁連結☎致電查詢或從以下途徑聯絡我們👇
Email👇
mail@hangkwong.com
Website👇
sites.google.c...
Instagram👇
/ master_kan_share_channel
Facebook👇
/ %e6%81%92%e5%85%89%e8%...
...........................................................................................................................................
📌行外人了解基礎原理就好了,不必深究.最多有興趣就知多一點點.......😁
📌裝修真係好多野要準備架,睇材料,比較,佈局設計,計劃,工序先後,訂貨,計算裝修費,
人工,時間等等都要計算在內喎!! 看似簡單.其實內裹大有學問✍
🤞不過我們裝修公司亦會提供不少建議,方案,方法,盡力配合🤝客人的需要及要求.
........................................................................................................................
[SUBSCRIBE]
勤師傅~分享頻道
/ @masterkansharechannel
• 裝修案例設計分享 | 記錄 | 參考樣板 |...
訂閱☑+禁埋個鐘仔(全部),就會收到通知可以第一時間睇我地既片啦~
...........................................................................................................................
KZbin(勤師傅~分享頻道)
/ @masterkansharechannel
#裝修 #維修 #固定電力裝置

Пікірлер: 83
@phoenix11chiu
@phoenix11chiu 7 ай бұрын
學到野, Thanks!
@MasterKanShareChannel
@MasterKanShareChannel 7 ай бұрын
感謝你請我飲杯暖心嘅咖啡😘, 多謝支持!
@傷心小臘腸
@傷心小臘腸 7 ай бұрын
Residual current circuit breaker先係叫漏電保護 ,overload current protection係MCB過載電流保護 Type B.Type C係 瞬間電流。如摩打一起動 電流 5-7倍。。 如 MCB / RCBO C40 或B 40 過載電流值40A RCBO/RCCB 30mA/0.03 漏電電流值
@GlenHui
@GlenHui 7 ай бұрын
多謝分享
@yeungandy5944
@yeungandy5944 7 ай бұрын
村屋係要用水總制的
@robertchan357
@robertchan357 7 ай бұрын
都係個句,一分錢一分貨。貨比三家很重要,平得不合理便要小心。還有出示電工牌很重要,但有牌也不等如有心做,有些為了取得訂單,可以將貨就價,做出不合格的東西。
@94023
@94023 2 ай бұрын
你有冇睇過錶前制系乜 人哋可能就係唔想成日去打錶前掣 所以水總做入屋 你咁改 分分中漏電都唔識跳
@generalning502
@generalning502 19 күн бұрын
我系女生,带电做有任何问题呢?我通常都带电做架喇!真正師傅是带电做的,不带电做的是学徒来架😅
@pwc3717
@pwc3717 16 күн бұрын
機電處 建議係不要帶電工作。
@kuongsam2314
@kuongsam2314 Ай бұрын
用正泰的都是大師傅,喜歡怎做便怎做! 個垃圾水總冷氣機著機CUT機有SURGE就會跳。
@kiwanyiu159
@kiwanyiu159 7 ай бұрын
村屋 入屋 配配箱 要用水總 電流式 漏電斷路器 容許漏電電流為30mA
@fat8cheung977
@fat8cheung977 7 ай бұрын
村屋拿電錶一定要裝表前水總.不過通常裝電錶箱內.要保護埋總線,一定拿完電錶後先換回3相表前制及換mcb箱獨立插座rcbo
@thk5615
@thk5615 6 ай бұрын
咁係咪即係條法例有問題呀
@get_troll
@get_troll 5 ай бұрын
@@thk5615水氣問題 一般村屋個水氣唔會夠令到個 最少60A個掣跳 你一係加水總 令佢接地漏電時跳 唔係earth fault時因對地阻值過高令到唔識跳掣就會有危險
@傷心小臘腸
@傷心小臘腸 7 ай бұрын
RCBO/MCCB/MCB不同掣 係指佢保護功能。RCBO係過載保護加漏電保護 佢原本個4Pole 總掣係國內款。漏電加過載保護。
@manchung5447
@manchung5447 7 ай бұрын
個人嘅認知。屋村電箱一定要用水總,沒看清楚片主錶前掣是否有水總,如果沒有,你改的電箱無法申請電錶
@pwc3717
@pwc3717 7 ай бұрын
其實好多舊村屋,或好多地方,中電都唔系要求一定要有水總。。 只系用水總會標准好多。 好多地線銅棍咩都無落。。 中電都比電錶,只系你做足d 佢就會易批d...
@HOMan2449
@HOMan2449 7 ай бұрын
👍👍👍
@MasterKanShareChannel
@MasterKanShareChannel 7 ай бұрын
多謝支持👍
@kakakok-y6m
@kakakok-y6m 7 ай бұрын
這改法收費可貴貴。燈和插座共同單一使用漏電掣也是合規格的。個人要求而已。最理想燈和插座各一個漏電掣最是好。獨立漏電掣一組燈雖好好。但是浪費金錢。
@MasterKanShareChannel
@MasterKanShareChannel 7 ай бұрын
各人想法要求不同!
@JackHa
@JackHa 7 ай бұрын
如果外國標準係必須要將燈分最小2組RCD , 安全考慮
@anthonyt4709
@anthonyt4709 7 ай бұрын
you wrote: "燈和插座共同單一使用漏電掣也是合規格的".
@94023
@94023 2 ай бұрын
村屋錶前又咪系水總 一9樣全屋跳
@laulau7772
@laulau7772 3 ай бұрын
村屋不是有水氣總制咩,裝水氣菲士有什么用??
@YipK100
@YipK100 7 ай бұрын
已知單位用3相電。有個燈制,有兩個開關,分別控制兩支燈。我們可以假設兩條相線,都是相同的嗎?即是兩個都是L1,或兩個都是L2,或兩個都是L3。
@MasterKanShareChannel
@MasterKanShareChannel 7 ай бұрын
三相電離計呢方面要小心處理, 每個燈開關電路係用相電, 假設如果有兩個開關電路 可以同時有兩相電存在( *即時Ll/L2), 切記要檢查清楚!!
@MasterKanShareChannel
@MasterKanShareChannel 7 ай бұрын
三相電離計呢方面要小心處理, 每個燈開關電路係用相電, 假設如果有兩個開關電路 可以同時有兩相電存在( *即時Ll/L2), 切記要檢查清楚!!
@YipK100
@YipK100 7 ай бұрын
@@MasterKanShareChannel我想换一個開關制,代替兩個制來控制兩支燈。如果兩條相線同相就可以簡單的接駁一起。但是若果兩條相線是不同相的話,一旦接觸,就會爆的。要知道兩條是否同相,可以把總制關掉,用萬用錶,分別放在兩條相線,如果見無電阻的,可以証明這兩條相線,是同相的,對嗎?
@anthonyt4709
@anthonyt4709 7 ай бұрын
@@YipK1001) you should never presume these 2 lights to be using the same phase. As a matter of fact, lightings using MIXED phases are suggested in certain scenarios. 2) as to how u distinguish which circuits belong to which phase(s), not only shouldn't u mix phases, but also not to mix MCBs as well. So your methodology is flawed.
@thk5615
@thk5615 6 ай бұрын
其實就咁喺嗰個 電箱嗰度都數到l123
@YipK100
@YipK100 7 ай бұрын
見三相電線接駁完總制後,經過銅 bar,怎樣接去不同的MCB呢?
@MasterKanShareChannel
@MasterKanShareChannel 7 ай бұрын
如果你是行內一定清楚🤗, 如果有興趣有時間 可以拆個廢料三相相研究一下! 包寶你了解更多。
@NxndDjdj
@NxndDjdj Ай бұрын
比得起錢就可以,現在好少😅
@MasterKanShareChannel
@MasterKanShareChannel Ай бұрын
錢作怪!
@WYC-z9c
@WYC-z9c 29 күн бұрын
師父,請教下,浴室有假天花,天花燈是DC,連接电子牛,見到电子牛input 只接火线及中线,水线没有接?水线應該怎處理?
@MasterKanShareChannel
@MasterKanShareChannel 29 күн бұрын
可以的話盡量找假天花或燈位接駁返!
@liberalstudiesmaterials899
@liberalstudiesmaterials899 7 ай бұрын
請問做自僱維修是散工, 收入不穩定? 如何能長做?
@MasterKanShareChannel
@MasterKanShareChannel 6 ай бұрын
長工多數做大廈維修保養!
@shingchun3454
@shingchun3454 7 ай бұрын
請問點樣搵返每組嘅青線?
@MasterKanShareChannel
@MasterKanShareChannel 7 ай бұрын
方法有好多 其中一種 用電錶
@homehome4204
@homehome4204 3 ай бұрын
近2天行雷下雨,地下村屋跳了2次水氣制,打上去就有番電,是什麼原因?
@homehome4204
@homehome4204 3 ай бұрын
要怎樣維修?
@MasterKanShareChannel
@MasterKanShareChannel 3 ай бұрын
村屋通常都係個 水氣問題!
@gnx01888771
@gnx01888771 7 ай бұрын
注意zs 是否在5秒跳閘
@kinsumc
@kinsumc 7 ай бұрын
請問水總係咪未必要用30mA?如要區分漏電保護,每組電路係咪可再用rcbo區分?
@MasterKanShareChannel
@MasterKanShareChannel 7 ай бұрын
👍
@pwc3717
@pwc3717 7 ай бұрын
其實唔使一定30mA, 不過30mA系人體安全電壓。 V(40)=IR (人體好似150 ohm), 反正最尾端老鼠尾要30mA, 但水總唔使。。唔知cop有無寫死…… 不過都要水氣(環路阻抗)度出黎低過COP規定。先可以有足夠故障電流打得郁個水總識跳制。 至于水總後再用RCBO老鼠尾,其實係可以的,不過多餘左一個電路有兩個水氣制。但如上級水總150mA, 下級RCBO 30mA個人認為沒有問題。
@JackHa
@JackHa 7 ай бұрын
怕死可以行10mA
@ilovehongkong2030
@ilovehongkong2030 7 ай бұрын
對村屋唔熟,不過村屋應該要水總一定有原因,150mA 或者買個100/200/500mA,用200mA做上級,再安全下級加返30mA老鼠尾,應該最安全做法
@kinsumc
@kinsumc 7 ай бұрын
@@ilovehongkong2030 因為村屋環境大多數接地比較差,環路阻抗數值較唔理想,所以規定錶前制或室內總制要有漏電斷路器保護..
@mimicheng5851
@mimicheng5851 5 ай бұрын
點先可以搵勤師傅電話
@MasterKanShareChannel
@MasterKanShareChannel 5 ай бұрын
影片下面連結
@譚洪進-h2j
@譚洪進-h2j 7 ай бұрын
是村屋,表前剩有水氣總線制保護嗎
@MasterKanShareChannel
@MasterKanShareChannel 7 ай бұрын
要有的
@redtea9899
@redtea9899 7 ай бұрын
最新鄉村條例,所有村屋總掣或者錶尾掣都要用水氣掣做開關,如果電錶位有水氣掣,個電工冇必要改電箱裝個水氣掣,留意一下。
@94023
@94023 7 ай бұрын
村屋表前行水總 一樣一跳全屋冇
@redtea9899
@redtea9899 7 ай бұрын
村屋一般水氣都低,而且外圍燈同裝置都多,所以先立例監管,水氣掣跳係正常保護,正常應該係找出跳掣原因而唔係要佢唔跳。
@pwc3717
@pwc3717 7 ай бұрын
​​@@94023 其實可以偷鷄改個150mA水總。。 勉強附合COP...
@tsuikh009
@tsuikh009 Ай бұрын
電騙....
@MasterKanShareChannel
@MasterKanShareChannel Ай бұрын
😳
@bennywong7088
@bennywong7088 7 ай бұрын
正泰唔掂?
@pwc3717
@pwc3717 7 ай бұрын
大陸正泰算最好。。
@jjjjjmmmm621
@jjjjjmmmm621 7 ай бұрын
行貨正泰同淘寶或大陸買嘅正泰有分別😅 另外村屋供電中電要做水總,唔知依加它電掛錶仲有冇依個要求😮
@pwc3717
@pwc3717 7 ай бұрын
​@@jjjjjmmmm621 我正想講。。 應該話近來中電要求掛電錶一定要用水總。 雖然話唔系一定,但用MCB測環路阻抗,9成唔合格。。用水總就放寬d…… 好似MCB幾ohm 至 合格… 用水總廁百幾ohm...差不多一定合格。
@pwc3717
@pwc3717 7 ай бұрын
​​@@jjjjjmmmm621 即係系cfu 非法改裝。。😢😮😮😅😅😊 唔知點講,出wr1, 保險等唔知會唔會比位人地入。。 都係跟我渣26去美團送外賣把。。😅😮😢😊😊
@MasterKanShareChannel
@MasterKanShareChannel 7 ай бұрын
香港就唔算好, 沒有最好只有更好🤗
@alexcheung4340
@alexcheung4340 7 ай бұрын
似大陸師傅
@MasterKanShareChannel
@MasterKanShareChannel 7 ай бұрын
🤔 唔出奇
@ft7777gmail
@ft7777gmail 7 ай бұрын
CHNT, 用呢隻真係害死人
[淘寶開箱] 淘寶去水隔氣&水龍頭夠竟能不能用? | 注意事項!?
30:41
勤師傅-分享頻道Master Kan-Share Channel
Рет қаралды 10 М.
修理潘 挑機 裝修昌
21:16
PoonCfu 潘師傅水電維修
Рет қаралды 55 М.
Which One Is The Best - From Small To Giant #katebrush #shorts
00:17
Ozoda - Lada ( Official Music Video 2024 )
06:07
Ozoda
Рет қаралды 19 МЛН
Do you choose Inside Out 2 or The Amazing World of Gumball? 🤔
00:19
哈莉奎因怎么变骷髅了#小丑 #shorts
00:19
好人小丑
Рет қаралды 55 МЛН
Fitting an RCBO in a Consumer Unit
12:33
John Ward (jwflame)
Рет қаралды 599 М.
錶前水總 VS 老鼠尾
15:28
PoonCfu 潘師傅水電維修
Рет қаралды 25 М.
三相熱水爐
17:23
EMHK
Рет қаралды 250 М.
9.30 的士亂收費?|華記正X樣炒燶的士牌!
11:38
美麗新香港投資日記 | Hong Konger's Investment Diary
Рет қаралды 21 М.
[突發] 做電漏水! | 供電裝置老化+接觸不良!?
8:09
勤師傅-分享頻道Master Kan-Share Channel
Рет қаралды 9 М.
Which One Is The Best - From Small To Giant #katebrush #shorts
00:17