HVAC 155 Nitrogen test with MQ and Probes

  Рет қаралды 9,009

Love2HVAC with Ty Branaman

Love2HVAC with Ty Branaman

Күн бұрын

Пікірлер: 17
@musakavalci9470
@musakavalci9470 2 жыл бұрын
Just downloaded the MQ app. Will give it a go.
@love2hvac
@love2hvac 2 жыл бұрын
It takes a bit of getting use to. Once your past the learning curve, it's a whole new world.
@musakavalci9470
@musakavalci9470 2 жыл бұрын
@@love2hvac just got used to the testo app. The MQ one looks pretty decent. Thanks again for the vids. 👌🏼
@UncleEarlHeatingAirCondition
@UncleEarlHeatingAirCondition Жыл бұрын
Thank you Ty
@kevinhoronzy6011
@kevinhoronzy6011 Жыл бұрын
Don't go so fast with when pressing buttons on the app. Hover over the icon so we can see what u are touching on the app.
@HVAC_Tips_Tricks_Calcs
@HVAC_Tips_Tricks_Calcs Жыл бұрын
2 questions. What if you're doing a mini split. Do you crack open the liquid line to purge air? Also. Do you need to keep MQ running the entire time or will it run in the background. Thanks!
@love2hvac
@love2hvac Жыл бұрын
I add a service port on the small line just for purging and pressure testing. I do leave MQ running.
@HVAC_Tips_Tricks_Calcs
@HVAC_Tips_Tricks_Calcs Жыл бұрын
thanks!
@TheRealoldcar
@TheRealoldcar 2 жыл бұрын
Is the test calculator set for nitrogen or the refrigerant entered in the system profile section of MQ?
@love2hvac
@love2hvac 2 жыл бұрын
Preset for nitrogen
@kevinhoronzy6011
@kevinhoronzy6011 Жыл бұрын
Could you also test the high side 300 psi or only limited to 150psi?
@ihg91
@ihg91 3 ай бұрын
Where do you get a nitrogen tank that small ?
@garypoplin4599
@garypoplin4599 11 ай бұрын
3:35 - Every time I attempt a screenshot here, MQ forces a logout of my account! What am I doing wrong?!
@love2hvac
@love2hvac 11 ай бұрын
MQ has changed since this video was made. They no longer allow screenshots unless you pay the $5 per location. Now some people using MQ on a tablet then taking pictures of that with their phones.
@matttzzz2
@matttzzz2 10 ай бұрын
What the fuk
@Doe08
@Doe08 Жыл бұрын
Why does my liquid line probe spray refrigerant out can someone help is it the probes or the system
@love2hvac
@love2hvac Жыл бұрын
The valve core in the system is probably backed out too far. Try tightening it up. You can also use Accutools S10767 Core Depressor Tool 1/4" x 1/4" It attached to the probe and allows you to disengage and engage the valve core manually.
HVAC 153 Nitrogen Pressure test with Analogue gauges
13:32
Love2HVAC with Ty Branaman
Рет қаралды 49 М.
БОЙКАЛАР| bayGUYS | 27 шығарылым
28:49
bayGUYS
Рет қаралды 1,1 МЛН
HVAC 110 Introduction to Measure quick and wireless probes.
22:32
Love2HVAC with Ty Branaman
Рет қаралды 10 М.
HVAC 119 Charging with Wireless Probes
12:54
Love2HVAC with Ty Branaman
Рет қаралды 46 М.
Nitrogen Facts and Tips
15:54
HVAC School
Рет қаралды 62 М.
HOW TO LEAK TEST AN AC SYSTEM WITH NITROGEN PRESSURE
6:38
Alex The Handyman
Рет қаралды 11 М.
mQ Getting Started Essentials - Adding Fieldpiece Probes
12:39
measureQuick
Рет қаралды 6 М.
HVAC 156 Nitrogen test with trace gas
7:06
Love2HVAC with Ty Branaman
Рет қаралды 6 М.
Heat Pump 12 Hight Pressure trips only in Heating
12:51
Love2HVAC with Ty Branaman
Рет қаралды 12 М.
Charging and Recovering with measureQuick
16:44
HVAC School
Рет қаралды 20 М.
Mini Split Workflow in measureQuick
10:34
measureQuick
Рет қаралды 7 М.
How to Leak Test an AC With Nitrogen Pressure
8:00
HVAC School
Рет қаралды 243 М.
БОЙКАЛАР| bayGUYS | 27 шығарылым
28:49
bayGUYS
Рет қаралды 1,1 МЛН