Diagnosing a Grounded Compressor 3D

  Рет қаралды 33,800

HVAC School

HVAC School

Күн бұрын

Пікірлер: 62
@920HVAC
@920HVAC Жыл бұрын
Another great animation! Thanks🤝
@garza1367
@garza1367 4 ай бұрын
This type of detail and animation can demand a lot of money. Thank you for offering such high quality education for free.
@jin8684
@jin8684 Жыл бұрын
These animations aren't easy to make. Great work!
@HVACS
@HVACS Жыл бұрын
Thanks a lot!
@lucianorosel8128
@lucianorosel8128 Жыл бұрын
The animation and narration were flawless, thanks for sharing!
@soloralphlauren2731
@soloralphlauren2731 Жыл бұрын
Such an awesome training video. Definitely make more of these animations!
@JayParaguison
@JayParaguison 11 ай бұрын
The work put on this video is 10+
@KelvinMcCullough-wl1yo
@KelvinMcCullough-wl1yo 10 ай бұрын
By far the animated education I've seen I literally want to get into HVAC because of this, just don't know if I can afford the schooling
@sirethegreat5800
@sirethegreat5800 Жыл бұрын
I’m really enjoying the animation so much better to understand the process we need more thank you
@ChewThenReview
@ChewThenReview Жыл бұрын
Thanks!
@johnthompson9918
@johnthompson9918 Жыл бұрын
Always a good refresher with good explanation 👍🏼
@MolecularHeckler
@MolecularHeckler Жыл бұрын
i usually start by unwiring the high voltage from the contactor of condensor. it makes it clear to me which direction to go next. my next step will be the compressor wire harness or the disconnect (depending if breaker tripped) then ill unwire the crank case heater and fan individually at a time. its usually one of them if its not the compressor.
@zahedaminullah6934
@zahedaminullah6934 7 ай бұрын
Amazing animation, good stuff, well taught
@YouTubeCommunists
@YouTubeCommunists Жыл бұрын
Thanks Bryan Ore you are a great teacher ma man!
@someonesecret
@someonesecret Жыл бұрын
Really great learning material. Thank you 🎉
@mr.mr.4356
@mr.mr.4356 Жыл бұрын
Wow that made look very easy and now I’ll know how to check for a grounded compressor. I used to have to call my professor and this had to share something with him, now I’m sure I can go ahead myself and do this. Gonna have to save this video in my favorites, this will be number one, keep up the great videos for us beginners. As only hands on apart from schooling will we learn.❤
@cherisseyomen7081
@cherisseyomen7081 Ай бұрын
What a great quality video!!
@GoodMemoriesToRemeber
@GoodMemoriesToRemeber 3 ай бұрын
learned a lot from this channel, thx
@mperry94
@mperry94 Жыл бұрын
These animations are great. Thank you.
@videos10
@videos10 Жыл бұрын
Damn these animations are some Hollywood disney level!!😮
@cameron3991
@cameron3991 Жыл бұрын
I usually add R22 until the head pressure hits 700 and the compressor gets super hot. I also throw water straight on the transformer and take out the fuses and use 00 copper wire to straight wire it
@corruptedbrain6
@corruptedbrain6 Жыл бұрын
LMAOOOOOOO
@CanogaHVACRLLC
@CanogaHVACRLLC Жыл бұрын
Extraordinaire! As always. Thank you so very much for the effort made.
@CommercialGasEngineerVideos
@CommercialGasEngineerVideos Жыл бұрын
Good illustration. Wish I knew how to to that.
@Sc19869
@Sc19869 Жыл бұрын
So if we get a high resistance it’s bad? And if we get a low resistance there is no short?
@EpyonRules
@EpyonRules Жыл бұрын
I'm assuming you're referring to the 22 vs the 5? The 22 was k(il)Ohms and the 5 was M(eg)Ohms. 1 kOhm is 1000 ohms, whereas 1 MOhm is 1 million ohms. When testing a motor terminal to ground, you want the resistance to be effectively infinite (OL for open line for standard meters, or something in the megohm range for a megger).
@Sc19869
@Sc19869 Жыл бұрын
@@EpyonRules thank you. Another question, so when checking to ground you don’t want any resistance just ol. Thanks for your help.
@JesusLopez-tz8yv
@JesusLopez-tz8yv Жыл бұрын
@@Sc19869you don’t want any resistance so when you’re measuring in ohms you should O.L or 0.000 reading no resistance
@EpyonRules
@EpyonRules Жыл бұрын
@@JesusLopez-tz8yv That's not true. When measuring to ground (with a regular/non-megger meter) you want OL. 0 ohms is bad in this instance because it means that there is a direct path from the winding to ground. OL and 0 ohms are two VERY different things. Edit for clarification: OL means there is no path. 0 ohms means that there is a path with no resistance.
@Sc19869
@Sc19869 Жыл бұрын
@@EpyonRules ol means you have an open circuit correct. And 0 ohms meant you have high current, so there is a short.
@lawrenceetsitty9031
@lawrenceetsitty9031 Жыл бұрын
Great video training thanks HVAC School
@EverythingHVACR
@EverythingHVACR Жыл бұрын
Always great content! Thanks
@leekazan556
@leekazan556 10 ай бұрын
Excellent presentation
@alexanderboyd2280
@alexanderboyd2280 Жыл бұрын
YOU DA BEST BRYAN! Much love from New Orleans!!❤️
@TexByte
@TexByte 5 ай бұрын
This video is awesome please make more like this . 👍🏻👍🏻👍🏻
@paulrozinski1488
@paulrozinski1488 Жыл бұрын
Very informative video, great animation .👍👍👍👍
@corruptedbrain6
@corruptedbrain6 Жыл бұрын
thank you for this video !
@HVACS
@HVACS Жыл бұрын
Glad it was helpful!
@corruptedbrain6
@corruptedbrain6 Жыл бұрын
@@HVACS even after i graduated, I still watch your videos so it becomes engraved in my mind ! I appreciate the videos
@IamProFish
@IamProFish Жыл бұрын
Really helpful! To you have a metric option for your online calculators?
@HVACS
@HVACS Жыл бұрын
Not yet!
@donaldmccuddy3611
@donaldmccuddy3611 4 ай бұрын
Thanks for the knowledge
@jordanallison2486
@jordanallison2486 Жыл бұрын
Had a compressor tripping over the weekend, we can’t leave it isolated to run for that long is there another way?
@mulet81
@mulet81 Жыл бұрын
excelent v 3d video,please continuos with more videos
@maness2112
@maness2112 Жыл бұрын
Beautiful. More please.
@Wlladdd
@Wlladdd Ай бұрын
Thank you
@FastechUniversity
@FastechUniversity Жыл бұрын
Wouldn’t you want to check the Fan Motor for a short also?
@NoeArauz
@NoeArauz Жыл бұрын
Hence the title of the video "Diagnosing a Grounded Compressor." The focus is the compressor because 90-95% of the time, it'll be the compressor that is tripping the breaker. If you follow the instruction and steps on this video, after isolating the compressor and the breaker STILL trips, 3-8% of the remaining possibilities will be a wiring issue. If you follow the instructions of the video, you'll have seen it BEFORE having to isolate the compressor, BUT can't always catch it. It's very rare that the condenser fan motor will be internally shorted. Almost always the condenser fan motor will be seized and obvious when resetting the breaker and testing the unit. This can eventually cause the compressor to run extra amperage for a long period of time and the second way a breaker will trip. My first test for a compressor is to move the blades attached to the fan motor and if it's stuck or if it DOESN'T move with more than a tap OR if the blades stop way to soon and sudden, the motor has seized or will seize the moment it gets power. Lastly, I've seen this in the field, is a fan motor that HAD been replaced but the drain plugs were not moved from one end of the motor to the other, depending on the way the motor sits. This causes water to COLLECT in the motor casing and will POSSIBLY (unusually motor is newish) cause a short. But more than likely, will rust the stator and metal to the point where friction and heat will cause the motor not to turn.
@stephenhart6158
@stephenhart6158 Жыл бұрын
top notch as usual
@caswaineessue5888
@caswaineessue5888 Жыл бұрын
Appreciate your videos
@mikemorton6219
@mikemorton6219 Жыл бұрын
If you depress suction Schroeder valve and it smells like acid, you have a failed motor.
@EarlHayward
@EarlHayward Жыл бұрын
Sponsored by… Square D… To be fair, Schneider has great products, including some very interesting cooling equipment…
@ryanasturias5465
@ryanasturias5465 Жыл бұрын
great,,,,more videos,,
@TraviGee-ns2yy
@TraviGee-ns2yy 7 ай бұрын
✅✅✅
@oscarsoto8413
@oscarsoto8413 Жыл бұрын
Perfectly
@paulb4496
@paulb4496 5 ай бұрын
Other quality multimeter THAT CAN READ MILLIONS OF OHMS....MOST FLUKE CLAMPMETERS ARE NOT CAPABLE OF THIS TEST. I USE A FIELDPIECE ,AMPROBE, UEI, IDEAL OR SPERRY CLAMPMETER.
@f.villanueva
@f.villanueva Жыл бұрын
🤍🤍🤍
@ewebbytrailscout
@ewebbytrailscout Жыл бұрын
Fox Family HVAC guy
@coldfinger459sub0
@coldfinger459sub0 Жыл бұрын
👍
Diagnosing a Locked Compressor 3D
10:02
HVAC School
Рет қаралды 75 М.
Understanding Low Voltage Wiring for AC & Heat Pumps 3D
15:12
HVAC School
Рет қаралды 270 М.
UFC 287 : Перейра VS Адесанья 2
6:02
Setanta Sports UFC
Рет қаралды 486 М.
Ful Video ☝🏻☝🏻☝🏻
1:01
Arkeolog
Рет қаралды 14 МЛН
24 Часа в БОУЛИНГЕ !
27:03
A4
Рет қаралды 7 МЛН
Setting a Charge By Subcool on a TXV system In 3D
10:36
HVAC School
Рет қаралды 223 М.
Check Compressor Windings With The Insulation Tester - Fluke 1507
4:25
GlobalHeatingCooling
Рет қаралды 45 М.
Testing if an HVACR Compressor is Shorted to Ground, Open, or Overload Tripped!
11:06
How to Evacuate an AC system, Full Vacuum Procedure
27:35
HVAC School
Рет қаралды 1,2 МЛН
HVAC Compressor Checks - Short to Ground
5:11
John Jennings
Рет қаралды 46 М.
Failed Compressors - Don't JUST REPLACE IT
24:59
HVAC School
Рет қаралды 68 М.
The Danger of High Airflow in HVAC
5:19
HVAC Shop Talk
Рет қаралды 43 М.
Run Capacitor Fundamentals Class
13:57
HVAC School
Рет қаралды 602 М.
Locked Compressors
20:13
HVAC School
Рет қаралды 118 М.
UFC 287 : Перейра VS Адесанья 2
6:02
Setanta Sports UFC
Рет қаралды 486 М.