Hydronic Heating For Van Life by Rixen's Enterprise

  Рет қаралды 32,064

Mathers On The Map

Mathers On The Map

Күн бұрын

Пікірлер: 163
@functionalvanconversion4284
@functionalvanconversion4284 10 ай бұрын
On the 7th year of Rixen system and i will never consider not using one, plus the customer service from Jim, Mike and Miguel is legit like America was once famous for👍
@Rvand4
@Rvand4 Жыл бұрын
I would insulate coolant hoses underneath, it’s easy and cheap. Great video as usual! We followed your previous build to get done ours. Probably time to follow again and start building something)
@artravision
@artravision 11 ай бұрын
Wow! Awesome tutorial. Thank you!
@guidolyons4912
@guidolyons4912 4 ай бұрын
I have Rixen's Espar D5WS in my Revel and I am mirroring that system in my Campulance conversion. It really is the best all around heating/hot water solution. Tied into engine heat exchanger free heat and hot water while you drive. Hydronic loop in the floor is so nice, no more cold feet!
@yorotirb3941
@yorotirb3941 Жыл бұрын
You might take a tip from humble road if you havent allready. Put your exchanger by the engine so that your 2 systems stay separated so if you spring a leak on one side it doesnt affect the other engine cooling system. Bet its nice not having to work in the street, LOL! Coming along really nice!
@mhelander
@mhelander Жыл бұрын
Adding proper valve assy to engine coolant loop provides 100% isolation of the hydronic system from engine coolant system in case of failure in its side. Definitely good idea as plumbing adds 5..10 meters of coolant hoses under the vehicle with multiple clamp connections...
@MathersOnTheMap
@MathersOnTheMap Жыл бұрын
Humble road is great and a good idea, I think I remember seeing him mount an exchanger in a pro master I think? there was like a perfect spot for it in the engine bay. Yea haha this definitely beats the street you got that right!! Haha
@MathersOnTheMap
@MathersOnTheMap Жыл бұрын
Love this idea, I’ll have to add in two valves 👌🏻👍🏻
@mhelander
@mhelander Жыл бұрын
@@MathersOnTheMap you need one 3-way ball valve from cabin heater to back to engine or to feed rear, and ball valve to rear return with T-fitting, preferably Gates fiber reinforced one. Normally 3-way valve flows to rear and return valve is open. In case is needed isolation change both valves so return is blocked and so is feed, 3-way will short cabin heater flow back to engine
@MathersOnTheMap
@MathersOnTheMap Жыл бұрын
@@mhelander good call I started thinking through this and 3way makes way more sense.
@dvpzy
@dvpzy 5 ай бұрын
This is great! I was trying to find this! Thank you! Now I know I need to keep the engine running if is too cold.
@libertine5606
@libertine5606 Жыл бұрын
I think that they have a heat exchanger that you can put into the engine compartment. That would isolate the coolant to the back from the engine compartment/radiator coolant. That way if the hose from the front to the back is broken your engine coolant won't be lost.
@MathersOnTheMap
@MathersOnTheMap Жыл бұрын
So three heat exchangers in total I guess? Not a bad idea, you can still have a point of failure in the engine loop, but less of a line to worry about…I carry extra coolant in the van just to be safe
@OCoilers
@OCoilers 7 ай бұрын
@@MathersOnTheMap you wouldn't need an additional heat exchanger, just relocate the existing one into a more protected area, so that if the coolant lines fail in the unprotected area, it's only the Rixen's system lines and not your van's.
@JaYoeNation
@JaYoeNation Жыл бұрын
Also. I’m curious where you connected the second floor circulation pump. Did that go into the rixon’s box? I only have one point for a single pump to connect up.
@JaYoeNation
@JaYoeNation Жыл бұрын
Did your LCD panel come with the system? Do you have a link for that? Searched Rixen sand can’t find it
@sneakybastardmusic
@sneakybastardmusic 4 ай бұрын
bump
@JaYoeNation
@JaYoeNation 4 ай бұрын
@@sneakybastardmusic I got a cool ricen LCD. It works great. WiFi is a bit finicky though
@katiebrages69
@katiebrages69 Жыл бұрын
Great job! Definitely not to dry. You do a great job explaining. Thank you!
@MathersOnTheMap
@MathersOnTheMap Жыл бұрын
Appreciate that thank you Katie!
@jessemock
@jessemock Ай бұрын
awesome video! what is the purpose of adding the heat exchanger under the van instead of letting it cycle the loop? Thanks!
@sophieboisvert
@sophieboisvert 3 ай бұрын
Great video thanks for the dedication and encouragement
@amora99121
@amora99121 Жыл бұрын
First off, love your channel and family. Love the life you live. Would you be able to show more in detail where you tap into the coolant lines to heat up your hydronic system. Not sure where to cut or which line to cut. Ty
@MathersOnTheMap
@MathersOnTheMap Жыл бұрын
Shoot me a message on Instagram
@lmullen9478
@lmullen9478 3 ай бұрын
I hopped on their website and from what I can tell, its about 10K for this type of set up which is waaaaay beyond affordable for me.
@bigmolar271
@bigmolar271 Жыл бұрын
You are clutch! Planning my build now. Enjoyable channel to watch your build.
@MathersOnTheMap
@MathersOnTheMap Жыл бұрын
Thanks hope you build goes smooth!
@rray3630
@rray3630 26 күн бұрын
Nice video and maybe it is just because I come the marine / super yacht industry where standards are high but ....that installation is sloppy ......was that professionally done ?
@MathersOnTheMap
@MathersOnTheMap 26 күн бұрын
Thanks! Sure if ya wanna call me a professional haha! Nah it’s all DIY
@ericdvorak7030
@ericdvorak7030 Жыл бұрын
Just what I needed, was just about to dig into figuring out where to tie into the engine heater core line. I have the same setup except with a cruise n comfort split a/c system. Nice setup, I’ll be following along as we’re pushing to be done by the beginning of August also.
@MathersOnTheMap
@MathersOnTheMap Жыл бұрын
Nice Eric!! Yep we tied into the driver side of the heater core where the 90 elbow was. Good luck with the build!
@ericdvorak7030
@ericdvorak7030 Жыл бұрын
@@MathersOnTheMap Thanks, I took a screenshot of the location from your vid. One last question, what size ID heater hose did you use? 3/4”?
@MathersOnTheMap
@MathersOnTheMap Жыл бұрын
@@ericdvorak7030 yep that’s correct 3/4 ID!
@SUPERno-friendo
@SUPERno-friendo Ай бұрын
What’s the power draw in comparison to just running the heater? Like the extra power from the pumps running the coolant?
@mausie1967
@mausie1967 Жыл бұрын
Thank you, I liked your video very much. Greetings from the Netherlands.
@MathersOnTheMap
@MathersOnTheMap Жыл бұрын
Thanks for watching! 😁
@laurieclarkson9180
@laurieclarkson9180 3 ай бұрын
I'm interested in Hydronic Heat for skoolies but I think we need much larger units/RV style. I'm sure Rixen probably makes something for that application.
@lee-3541
@lee-3541 Жыл бұрын
Let's see... Heating system, circulation system and control system... GOT IT! 👨‍🎓 Then again, I love to design and build stuff as well... 👍on the vlog...
@MathersOnTheMap
@MathersOnTheMap Жыл бұрын
Thanks Lee!!!! Hope you’re doing well!
@silvercelloAG
@silvercelloAG 4 ай бұрын
Curious about how the system has been performing after having it for over a year (and through a winter?) I purchased the same system from Just Roaming, and have the floors installed and finished. Currently looking for a shop to complete the installation. Someone at the Sprinter-Forum mentioned that pex can cause oxygen related corrosion issues and pex-al-pex should be used instead. Interested in any thoughts on this and the performance of the system so far. Thanks for the video!
@rhusolo
@rhusolo 5 ай бұрын
Hey Kevin third time watching this install and it is a great help for installing my Rixen’s system. Thanks so much. Do you have any recommendations for the under bed install? Like does the reservoir radiate a ton of heat under the bed? Should it be a certain distance below the bed? Love to know your experience. Thanks. PS wishing you guys all kinds of joy on your future non vanlife adventures. Looking forward to see what you get up to. 😊
@MathersOnTheMap
@MathersOnTheMap 5 ай бұрын
If you're going to hook it up to the engine, I would install a heater core bypass valve to turn off the loop in the summer when you don't need passive heat generated from the coolant loop. Otherwise you're only going to create heat in the summer when you need hot water which isn't for a long period of time and wont make a difference. In the winter when the heater is running the passive heating from the coolant reservoir will be a nice add. We had about 3 inch clearance from the top of the resevoir to the plywood supporting the bed. Hope that helps.
@rhusolo
@rhusolo 5 ай бұрын
Awesome idea thanks for this I didn’t consider the engine heating it up in the summer thanks so much. 🙏
@MeTooHigh
@MeTooHigh 10 күн бұрын
What coolant hose did you use to extend the engine coolant loop?
@AdventureOtaku
@AdventureOtaku Жыл бұрын
Excellent. Looks like a nice system. Well done. You do really nice builds.
@ConstantinDendrinos
@ConstantinDendrinos 11 ай бұрын
Great video! Thank you!!
@RickM-p2s
@RickM-p2s 4 ай бұрын
What was the logic behind having the air heater and the water heater on the same circuit instead of the air and floor on the same circuit? You will mainly be wanting air and floor heat at the same time, but during the summer, you would only be needing the water heater
@FrancoisCusson-v2m
@FrancoisCusson-v2m Ай бұрын
Comment vous avez choisi vos heatexchanger. Il y en a plusieurs sur le marché. A savoir des 40 plaquettes jusqu’à des 100 plaquettes sur Amazon. Faut il avoir plus gros ou un plus petit pour un plancher de 96pieds le pipe radiant. Merci de votre réponse
@shesails3313
@shesails3313 Жыл бұрын
Excellent video!! Thank you!
@Rodney_Trotter_Dave
@Rodney_Trotter_Dave Жыл бұрын
Can’t wait to see it in action and have your review on it 👍
@MathersOnTheMap
@MathersOnTheMap Жыл бұрын
Same here! Already tested the heated floors and it’s so sick! Just didn’t really flow with the style of this video to include it.
@danyloprozorov4675
@danyloprozorov4675 Жыл бұрын
@@MathersOnTheMap what do you think about heated floors performance? Does it provide enough heat for the van?
@rjhunter_5318
@rjhunter_5318 Жыл бұрын
Nice job. What do you have going through the floors to actually heat them, is it a heating element, hoses, what?
@MathersOnTheMap
@MathersOnTheMap Жыл бұрын
Pex with glycol (anti freeze) running through
@noobtubekilla
@noobtubekilla 10 ай бұрын
Thanks for the video. Do you use self tapping screws to attach the insulated hose clamp to frame? Or did you use rivnuts?
@midway241
@midway241 Жыл бұрын
Nice job explaining and installing.
@MathersOnTheMap
@MathersOnTheMap Жыл бұрын
Thank you!
@thebatlwgn
@thebatlwgn Жыл бұрын
Thanks for the breakdown on this. Super helpful.
@ryanrowe1975
@ryanrowe1975 Жыл бұрын
Great job!
@MathersOnTheMap
@MathersOnTheMap Жыл бұрын
Thanks Ryan!
@ryanrowe1975
@ryanrowe1975 Жыл бұрын
@@MathersOnTheMap You're Welcome
@atozvanlife
@atozvanlife Жыл бұрын
Great video, thanks! How hot do the outside of the heat exchangers get?
@MathersOnTheMap
@MathersOnTheMap Жыл бұрын
Definitely hot! I haven’t did a temp test though
@Darrin-zq5bk
@Darrin-zq5bk 9 ай бұрын
Question how would it affect the environment, if at all, when running very cold water thrrough a hydronic system?
@omjaye
@omjaye Жыл бұрын
Nice explanation. How do you like the system? Is the heated floors an incredible upgrade from just an air furnace? Or is it more of a luxury item that gives warm toes but still need the furnace blowing? Basically how would you evaluate the choice of having heated floors or not?
@MathersOnTheMap
@MathersOnTheMap Жыл бұрын
I’ll tell ya once we hit the road 😅 still building!
@omjaye
@omjaye Жыл бұрын
@@MathersOnTheMap Sounds good. I'm just starting my build and this floor decision is holding me up!
@MathersOnTheMap
@MathersOnTheMap Жыл бұрын
@@omjaye I spoke a lot with the guys over at Rixen’s and I believe the floor is a pretty power heating element and the combination with the blower is really good. The furnace that heats the coolant is running whether or not the air blower is on to heat the water and floors. Does that make sense?
@janvanderdonk5294
@janvanderdonk5294 Жыл бұрын
Hi Kevin. Chapeau for a great job in explaining your design. Would you mind supplying a link to which “kit” you purchased from Rixen. I am planning the same on a 144” 4x4 sprinter and would really appreciate a source to purchase the above unit. Does Esperbacher build the diesel engine and Rixen put the kit together. I’m in Nova Scotia. Feel free to driveway surf if you get nearby. Regards Jan
@MathersOnTheMap
@MathersOnTheMap Жыл бұрын
Hey! Hope you’re safe and the fires didn’t affect you in NS. We’re hoping to head that way sometime in August! The link is in the description to MCS7 system, let me know if it doesn’t work. That’s correct, Rixen uses the esperbacher hydronic furnace with its own proprietary software to program everything together, along with the pumps and the comfort hot coolant reservoir.
@janvanderdonk5294
@janvanderdonk5294 Жыл бұрын
Hi Kevin Thanks for asking. The fire is nearby and safely contained due to a recent deluge. Thank you for your prompt reply. Wondering which additional kits you purchased and is one blower enough? Feel free to drop in when in the area. You can even enjoy a long shower with an endless water supply and I’ll make a few suggestions on things you might want to explore in Nova Scotia.
@gregjonesdfw
@gregjonesdfw 9 ай бұрын
Great video. What would you recommend for heated floors in a 8.5 x 20ft cargo trailer?
@guidolyons4912
@guidolyons4912 4 ай бұрын
Hydronic floor heat. Run pex loop in the floor.
@wanderingzythophile9083
@wanderingzythophile9083 Жыл бұрын
Curious about your engine coolant system connection. I don't think I saw a fluid pump added into that long loop of coolant hoses; is this meant simply to heat the coolant in the house system from the engine side of things as you drive? Or to heat the engine coolant while parked up to make getting the van started in cold conditions easier? As someone else said in the comments, you might consider adding another heat exchanger, one up much much closer to the engine; if one of those long hoses catches a rock and leaks out coolant, that's your engine coolant and you could get stuck, or worse, damage the engine. Another heat exchanger would segregate the engine side. Also, I see your furnace exhaust pipe snaking between those two long coolant hoses - are those touching at all? Any issues with the furnace exhaust pipe getting hot enough to damage the coolant hose(s)?
@fabiocervantes1506
@fabiocervantes1506 Жыл бұрын
Man, I love the video! just a question, i bought the kit bu t didnt came with the cable that conect the central electrical box on the monitor screen (AB). did yours come with that or did you need to buy it separated?
@MathersOnTheMap
@MathersOnTheMap Жыл бұрын
Thanks!!! the screen connects via wifi no connection needed other than a positive and negative 12v power.
@lan.o
@lan.o 10 ай бұрын
THanks for a great video!
@mightbefire
@mightbefire 3 ай бұрын
Ever since I heard about hydronic heaters drying out the engine oil pan and wrecking the engine next time you start the van I've always been scared to hook up into the van's coolant lines.
@justfollowthatvan6721
@justfollowthatvan6721 27 күн бұрын
Is it possible to just not do the engine connection portion and only rely on the other 2 heat methods?
@mightbefire
@mightbefire 27 күн бұрын
@@justfollowthatvan6721 I would think it has to be.
@JaimetheNomad
@JaimetheNomad 11 күн бұрын
@@mightbefirethe engine heat portion is an added cost and purely optional. Also, the vans coolant lines never mix with the Rixens system, it only passes through the plate exchanger which heats the Rixens coolant. The two coolant systems stay independent of each other.
@LizHouck
@LizHouck Жыл бұрын
From one teacher to another….Great job explaining 👍🙌
@MathersOnTheMap
@MathersOnTheMap Жыл бұрын
Thank you Elizabeth!!!
@banaltra
@banaltra Жыл бұрын
I’m curious to see how well this goes in the winter. Want to get a good system for a van so we can ski here in Europe. I’ve heard people say use a false floor to protect the lines from freezing up but I see yours are under the van. Do u think any hoses/lines have the potential to freeze up being exposed under the van even if well insulated? Also, is there an option in the settings of the touch screen to change to Celsius rather than Fahrenheit?
@MathersOnTheMap
@MathersOnTheMap Жыл бұрын
Yes they can definitely freeze, most just empty drains directly onto the ground during the winter and use natural organic products so it doesn’t impact the environment. Yes you can change the temperature type
@billblecher9215
@billblecher9215 Жыл бұрын
Looks like you're doing pretty good work
@MathersOnTheMap
@MathersOnTheMap Жыл бұрын
Thanks Bill!
@lovespinkk01
@lovespinkk01 Жыл бұрын
Amazing video, thanks so much! What's the difference between the MSC7 and MSC6? I couldn't figure it out. Also, did you buy the floor heat kit from them as well? Why did you choose to/not to?
@MathersOnTheMap
@MathersOnTheMap Жыл бұрын
Thanks Jordyn! We got the floor kit from Just Roaming Design who partners with Rixen. Here’s the video on the floor if your interested: kzbin.info/www/bejne/mXyVqJRsmruBjs0
@GTASpuds725
@GTASpuds725 Жыл бұрын
Late reply but looking at the two kits-- it looks like the main difference is the controller--- MSC7 has a nice touch screen interface, the MSC6 has the old style with buttons and LED digit display and back lights for heat sources-- in addition it looks like you don't have to wire anything to the control board directly on the MSC7-- it has a pin connector to the board that goes to lever wire clamps-- much easier to wire then the MSC6.... we are looking to buy the MSC7 kit---
@homerguerrero
@homerguerrero 9 ай бұрын
Awesome video!
@jemjr1628
@jemjr1628 Жыл бұрын
That is one bad ass van!!! Do these vans come loaded up? Huge price difference?
@MathersOnTheMap
@MathersOnTheMap Жыл бұрын
Thanks John! Yea you can find them through outfitted companies and they’re going to be expensive, the storyteller van we had the chance to use in Oregon was 188k! Our van is going to be expensive don’t get me wrong, luckily many companies are working with us throughout the build.
@jeffsgarage8414
@jeffsgarage8414 Жыл бұрын
Could you do an update on this as far as how efficient showering is with just a heat exchanger to heat the water?
@MathersOnTheMap
@MathersOnTheMap Жыл бұрын
It works really well and the water is HOT! Maybe I’ll put something together, no guarantees though since I’m more focused on travel content these days
@mhelander
@mhelander Жыл бұрын
I've built my hydronic heating system so that there is Autoterm 5kW diesel furnace, installed just front of driver's side rear wheel. Hot water goes through floor to 15 liter hot water tank coil, then to other side to kitchen where is manifold for floor heating system and air coil with fans, both have separate thermostat. Return goes through floor to engine bay where is three valve manifold connecting to post cabin heater pre engine & coolant expansion tank, then to furnace pump. So my system uses solely engine coolant circuit and its expansion tank. There is high flow circulation pump in front of furnace and second for floor circulation which has also hydronic down mixing 3-way valve. For hot tap water, there is 3-way valve in front of its circulation pump, valve controls circulation through either kitchen tap re-circulation loop for rapid hot water to conserve water consumption, or to circulate through plate heat exchanger to post heating recirculating shower flow (which is 100% separate from fresh water system). It took only two arctic winters to dial everything right, now it works like a charm!
@mhelander
@mhelander Жыл бұрын
And my system can source heat from furnace to living quarters, then prior to start driving adjusting engine compartment valves to pre-heat engine. Then while driving engine heats everything until it's colder than -25°C when cabin heater cools flow too much and need to separate engine from circulation. Hot water tank has also 1kW resistive element which is available for summer time to get hot water when batteries are nearly fully charged.
@MathersOnTheMap
@MathersOnTheMap Жыл бұрын
@@mhelander This sounds like a beast of a setup!!! I’m assuming it’s all custom/DIY? Do you have any concerns of water freezing for the water line going through the floor? I’m guessing you insulated the hell out of it. Thanks again for the valve tip!!!!
@mhelander
@mhelander Жыл бұрын
@@MathersOnTheMap Yes, insulated bulkhead 50+ mm XPS, walls & ceiling 50mm XPS, floor 70mm PU with hydronic tubing on heat spreader. Doors and part of passenger side still to get properly insulated. Only window is in side door, double glazed, and no holes or hatches on roof because it's completely used for 900Wp solar. This was just very comfortable last winter, coldest -28.7°C...
@mhelander
@mhelander Жыл бұрын
@@MathersOnTheMap Ah what comes to water pipes, fresh water tank 70 liters is internal, of course. All water lines are inside and made sure while constructing cabinets and all that there is enough air circulation to keep even corners warm. And there is hydronic line near plumbings and it also goes under the LFP battery setup. Garage is under bed, fully insulated from living quarters, and only heated from floor. Coldest garage floor spot has been above +4°C without additional air circulation from living quarters where when colder fan coil thermostat keeps temps comfortable.
@timcasonful
@timcasonful Жыл бұрын
Hey Kevin, Im installing my system now and noticed you also used white pex. I have been reading that hydronic should actually use the orange pex that has an oxygen blocking layer. Have you seen any issues with rust? Apparently that is what the orange prevents. Thanks, Tim
@MathersOnTheMap
@MathersOnTheMap Жыл бұрын
Hey Tim, I read that too when I was looking into it. However this came directly from just roaming design. I haven’t seen any issues with rust and feel confident in the pex we have, however I’m sure orange is probably best
@timcasonful
@timcasonful Жыл бұрын
Thanks for the reply.
@alextran8585
@alextran8585 Жыл бұрын
what connection did you use to connect the pex back to the heater hose?
@johnnydavies12345
@johnnydavies12345 10 ай бұрын
Why wouldn't you just add an Isotemp (glycol heated water tank) and add an Espar heater. Aside from not having the heated floor element wouldn't it give you the same thing you're getting with the Rixon for a fraction of the price? Does anyone have any insight on this? Am I missing something?
@timothyleonard2902
@timothyleonard2902 Жыл бұрын
The vans looking great! I have the same system minus the extra heat exchanger under the van. Also are you going to have a 3rd pump to pressurize the water running through the van? Maybe once both our vans are done we can meet up and play some pickball! Ha
@MathersOnTheMap
@MathersOnTheMap Жыл бұрын
Thanks! We have the seaflo water pump for our water lines (same one we had in the last van worked great!) Haha maybe! we love pickle!
@synos0202
@synos0202 8 ай бұрын
Is there a reason to run the disel fuel line outside the Vehicule? I live in canada and we have -40 winters sometimes. It feels like if my diesel fuel line is inside my vehicule i wouldnt have the problem of it freezing? Is there a reason to keep that fuel line outside? Thanks
@ashleypynn5428
@ashleypynn5428 Жыл бұрын
I have the Espar D5E and i’m confused because I have seen it installed so many different ways i’m not sure which is correct anymore. Ideally, I’ll have the options of hot water, air and floor heating. I’ve got the pex lines installed in the floor, the air blower and am going to hold off on the hot water for the moment because it’s winter and I need warm air. I’ve got the coolant reservoir installed to the pump, the heater is installed outside of the van. In some videos I’m seeing the pump directly to the heater and the heater to the heat exchanger but your setup has the coolant going to the heat exchanger then to the heater… does it make a difference which one i go to first?
@billpizzifred5769
@billpizzifred5769 9 ай бұрын
Since they did not respond, I'll give it a shot-- IMO putting the "water heater" before the air heater would give you more consistent hot water temp-- with the air heater first, if say while using the water heater and the "air heater" fan kicks on, that would cool the coolant going to the water heater a bit and make the temp drop some-- if you put the water heater first, then if the air heater fan kicks on it would not affect the water temp since it is after the water heater... now thermodynamically, that is what would occur-- but not knowing how much of a temperature drop you get across the air heater, not sure how "much" it would be affected by this-- it could be negligible... if say the coolant only dropped a few degrees---- if it drops alot, then it could affect the water temp by alot also.... that's my take anyway.... HTH
@seamusstaveley-ocarroll4283
@seamusstaveley-ocarroll4283 Жыл бұрын
I noticed you run your system from the furnace to the expansion tank but all other videos I see run from furnace to heat exchangers with the expansion tank coming last. Is there a reason you chose to do yours that way? Does going to the expansion tank first cause an extra loss of heat?
@MathersOnTheMap
@MathersOnTheMap Жыл бұрын
I just followed Rixen’s diagrams and instructions, check out their learning center on their website for their diagrams, super helpful!!
@wonkywade
@wonkywade Жыл бұрын
Wow you’re the best
@LilyWasHereMB
@LilyWasHereMB Жыл бұрын
My builder installed the Rixen Sys. in my 2019 3500xd. The controls are rather crude. There is a Espar control, which does nothing, maybe sets the max run time. the Rixen thermostat controller does seem to piggy-back off of it though as they are wired together - don't know why. In addition to those control elements, there is a 3rd panel with rocker switches for system on/off, furnace on/off, water on/off, and a 2 speed fan rocker. I do not have radiant floor heating. I like the touch screen you have. Will it work on my 2019 system?
@MathersOnTheMap
@MathersOnTheMap Жыл бұрын
It should you can contact Rixen's to upgrade but it will definitely come at a price. I think they have a few videos discussing the upgrade
@puretrouble1603
@puretrouble1603 Ай бұрын
Is what you are calling a furnace actually a boiler??
@braxenaeurasiers
@braxenaeurasiers Жыл бұрын
Hello nice video! I am thinking of getting the same system. How do you like it after using it?
@MathersOnTheMap
@MathersOnTheMap Жыл бұрын
We like it a lot! We haven't been in really really cold winter climates with the van yet, but so far so good. If you're not going to be in really cold climates then the heated floors is more of a nice to have and i'd probably save the money. But if you will be in cold climates the heated floors are so nice!!! Our old van's floor used to be FREEEEZING, not in this van. Rixen's is an amazing company with the best customer service.
@braxenaeurasiers
@braxenaeurasiers Жыл бұрын
@@MathersOnTheMap Thanks for the reply! I have talked to Rixen a few times, they are wonderful! I have read other pros for a heated floor include dust doesn't get blown about, and that when you open the van door all the heat doesnt just go out. It takes longer to warm up but then longer to cool down. The cabinets stay warmer, etc. So I think there may be more benefits other than just freezing cold. At least I am trying to justify spending 10K as I do not plan to be in freezing cold. While the heated floor takes its time to warm up, you can always turn on the blower right? ;-) BTW you are a handsome man, and congratulations on your new baby!
@gpl422sda
@gpl422sda Жыл бұрын
How much more coolant do you need to put into the radiator for that long loop?
@MathersOnTheMap
@MathersOnTheMap Жыл бұрын
About a gallon, however a little spilled out when I cut the hoses
@bigmolar271
@bigmolar271 Жыл бұрын
Can you utilize an independent source of glycol instead of tapping into the van's?
@MathersOnTheMap
@MathersOnTheMap Жыл бұрын
We utilize an independent source in the comfort hot reservoir, it’s completed isolated
@modeverything9949
@modeverything9949 3 ай бұрын
I’ve seen a thousand instal vids, but do you really get unlimited hot water?
@sunnywilds3760
@sunnywilds3760 Жыл бұрын
Hi does it have to use deisel fuel, what if my van just uses gas?
@sunnywilds3760
@sunnywilds3760 Жыл бұрын
And because of this system can i put my water tank now under the van
@MathersOnTheMap
@MathersOnTheMap Жыл бұрын
@@sunnywilds3760 yes there’s a gas version check it out at rixens website! I think you could put your tank wherever you want without worry about what system ya go with
@CobrTom
@CobrTom Жыл бұрын
Does the touchscreen unit just connect wirelessly to the control unit? looks like only power gets fed into it?
@MathersOnTheMap
@MathersOnTheMap Жыл бұрын
Yes it does my bad I should have showed that!
@CobrTom
@CobrTom Жыл бұрын
@@MathersOnTheMap So can you access it from another app or tablet? or strictly via their wall mount? Wifi or bluetooth?
@michaelscarfi3196
@michaelscarfi3196 Жыл бұрын
Nice job. My only difference of opinion is it wouldn’t matter if you had a 10 gallon water heater it doesn’t add another ounce to your carrying capacity. Think about it and you’ll see why.
@MathersOnTheMap
@MathersOnTheMap Жыл бұрын
Thanks Michael!!! You don’t think so? I mean ya got to pressurize the system first but once you do doesn’t the tank hold 2.5 gallons ready to heat up. So then if you refill your water tank it would be the tank + the hot water heater capacity right?
@michaelscarfi3196
@michaelscarfi3196 Жыл бұрын
@@MathersOnTheMap when your big tank is empty you know longer have any water to push the water out of the water heater so it will just sit there full. You will still have it on board but you can’t use it.
@MathersOnTheMap
@MathersOnTheMap Жыл бұрын
Ahhhhh!!! The light bulb finally turned on, thanks for the tip
@joeo8396
@joeo8396 Жыл бұрын
How much more coolant (antifreeze fluid) did you use?
@MathersOnTheMap
@MathersOnTheMap Жыл бұрын
About another container
@Wrenchmonkey1
@Wrenchmonkey1 Жыл бұрын
You might want to plumb in some valves so that you can bypass the engine coolant system when you're parked. It seems like your engine cooling system (ie, that giant radiator on the front of the vehicle) is just going to be dumping valuable heat energy right outside, 'heating the great outdoors'. I would want a way to isolate the two systems for when you're parked and just running your heat and water directly off the diesel heater.
@johnleaste828
@johnleaste828 Жыл бұрын
Every engine has a thermostat which blocks off the radiator so it's already built in.
@Wrenchmonkey1
@Wrenchmonkey1 Жыл бұрын
@@johnleaste828 That's not actually how thermostats work, but nice effort. 👍
@wanderingzythophile9083
@wanderingzythophile9083 Жыл бұрын
That's not an issue at all with his setup. Note the heat exchanger at the rear of the van, right next to the furnace; the house system is isolated from the engine system via that heat exchanger. Yes, some heat from the house system will be lost to the engine system when parked, but the coolant on the engine side isn't flowing so there won't be much heat loss.
@Wrenchmonkey1
@Wrenchmonkey1 Жыл бұрын
@@wanderingzythophile9083 The water in the van's coolant system WILL circulate, as the hydronic system heats the coolant in the heat exchanger. "Some people think that thermodynamics don't be like that, but it do." -Neil Degrasse Tyson, Probably.
@praxton
@praxton 4 ай бұрын
This is for the more affluent van lifers who do it for the novelty or to support their channel.
@rray3630
@rray3630 26 күн бұрын
yep......we sailed around the world pre GPS and no refrigeration .....before it was "easy or trendy"......and gasp....without a PATREON account
@chaselfrantz5882
@chaselfrantz5882 Жыл бұрын
Great video! Question, does the engine loop always circulate when the engine is running? Or is there a separate pump for circulating that?
@MathersOnTheMap
@MathersOnTheMap Жыл бұрын
Engine loop always circulate from the engines water pump. If you had the preheat option you would have to add an additional pump in the loop and then use the eberpacher furnance to preheat the engine
@BroadwayLTDProductions
@BroadwayLTDProductions Жыл бұрын
You have to put anti-gel in your fuel tank if you are gonna be in cold temps or that fuel will gel up on you.
@MathersOnTheMap
@MathersOnTheMap Жыл бұрын
That happened to us in Vermont in our old van!
@jeffsteinmetz7188
@jeffsteinmetz7188 Жыл бұрын
I have the Rixen system also, but I am not hooked up to engine heat and don’t have floor heating. Are you using the engine water pump to push that engine hydronic fluid aft and then forward again? Any concerns about your engine coolant exposed the length of your van 2X? Agreed Rixen support is second to none!
@MathersOnTheMap
@MathersOnTheMap Жыл бұрын
Hey Jeff, I had the same questions that I asked them myself. They confirmed the engine's water pump is more than strong enough to move the coolant back and forth, even where I chose to put my heat exchanger, all the way in the back!
@mikejohnson7768
@mikejohnson7768 Жыл бұрын
Hi Jeff, I have a d5 heater and would like to install the basic hydronic system like you in my sprinter. Can you tell me which kit I would need to purchase for this particular install, thanks.
@winnieraygo6994
@winnieraygo6994 Жыл бұрын
its the best system for van life :) !
@MathersOnTheMap
@MathersOnTheMap Жыл бұрын
Agreed!
@michaelandrade1213
@michaelandrade1213 6 ай бұрын
Cost?
@joeo8396
@joeo8396 Жыл бұрын
Where is Glen?
@MathersOnTheMap
@MathersOnTheMap Жыл бұрын
We miss Glenn!
@TroyD-vo1bz
@TroyD-vo1bz 2 ай бұрын
I don't quite understand why these systems are so expensive. When you look at individual part prices, it sure doesn't make sense.
@123klaas
@123klaas Жыл бұрын
Nice system, but its the same price of the whole rv that I'm buying.
@chrisdaniel1339
@chrisdaniel1339 Жыл бұрын
For $6,000 plus installation there are much better and less expensive heating options for RV's, vans, overlanders, or expedition vehicles. I agree that having a loop to use engine coolant and a plate heat exchanger with radiant in-floor heating is part of the solution to keep the living area in a van warm while driving and engine heat is free. In the same coolant loop as the radiant floor heating you install a small radiator(about the size of a transmission oil cooler) with a 12v slow turning, quiet, but high volume fan that will also help heat the air again using engine heat/electricity. The third heat source is a point of use electric tankless water heater made in Germany by Stiebel Eltron and a small 2-6 gallon/min circulator pump. The circulator pump is what triggers the the tankless water heater to turn on and the only other items you need is a digital thermostat and relay for the circulator pump. Every 100 ft of 1/2" PEX tubing holds aprox 1.3 gallons of coolant and a van would use under 200 ft, meaning the entire heating system uses less than 3 gallons of Propylene Glycol and water mix so the circulator pump only needs to have a small volume of gal/min to circulate the entire volume of the system twice per minute. Typically there is only a 20F degree drop in a loop of radiant floor so it does not take much electricity to raise the temp of the coolant back up 20F degrees to the set temp of 105-110F. One mistake vanlifers make is only running PEX radiant heating tubes in the walking areas of a van, you must remember everything in the van must be heated up to be comfortable and warm the space. By putting loops of PEX under the bed area, under cabinets, under the entire living area it helps to warm everything in the van making heating more effective and maintaining a comfortable living area. I figure you could install the heating system I suggested for less than half of a Rixen system.
@lhackinen3684
@lhackinen3684 Жыл бұрын
Makes sense if ...."20F degree drop in a loop of radiant floor so it does not take much electricity" were true. ( actually a lot lower Temp drop but doesn't matter) The amount of energy required to raise the temperature of the coolant is related to the temperature rise and the Volume. 1 BTU is 1 lb of water 1 degree F. But you need to addc " time" to the equation. 1500 watts is 5118 BTU's per hour. ( about what the diesel heater puts out ) . That is 125 Amps at 12 volts. You need really big battery to sustain that current , and a Generator to charge it. ( the Van alternator is not nearly enough)
@alzathoth
@alzathoth Жыл бұрын
Seems like a LOT of $$$$
Hydronic vs Air Heater | Which is the Best Van Heating Option
27:46
小丑女COCO的审判。#天使 #小丑 #超人不会飞
00:53
超人不会飞
Рет қаралды 16 МЛН
Леон киллер и Оля Полякова 😹
00:42
Канал Смеха
Рет қаралды 4,7 МЛН
Rixen Hydronic Heating Installation in a Van
28:08
Under The Radar Van
Рет қаралды 13 М.
It's not even close | BEST van heating system!
10:40
Jon Patton + The BATLWGN
Рет қаралды 10 М.
Van Walls and Ceilings | Pro Builder Shares Tips
19:09
Thrivans
Рет қаралды 28 М.
Advanced Water System for Campervan (Off Grid Breakdown)
15:57
Ladi & Margaret
Рет қаралды 74 М.
The best way to heat water in a camper van #vanlife
47:52
Mel's Big Van Small World
Рет қаралды 31 М.