Hydrostatic Testing of Stored Pressure Fire Extinguisher Final

  Рет қаралды 40,128

IowaFireControl

IowaFireControl

Күн бұрын

Пікірлер: 50
@robcampbell1056
@robcampbell1056 Жыл бұрын
I own a Fire Prevention Company and have been testing Fire Extinguishers for 30 years. This is exactly what a testing room looks like. Powder everywhere. There are many other videos out there, usually by manufactures of equipment that show a perfectly clean shiny room with no yellow powder anywhere... Yeah, right... The only thing this video didn't show you is the holes in the walls because you get mad when an extinguisher goes off and the technician throw the thing against the wall. and then rights NFG on it.
@oldmech619
@oldmech619 Жыл бұрын
I have a bunch of old fire extinguishers. A couple were partly discharged. What should I do with them. 5pound
@stevecraighead4816
@stevecraighead4816 Жыл бұрын
My shop looks nothing like that and I’ve been doing fire extinguishers for over 20 years myself. I also have SOP’s in place to control the powder versus what I see in this shop. Dumping chemical into an open bucket instead of having a bucket lid on the top with a hole cutting it so just the mouth of the extinguisher cylinder fits in it. That cylinder vacuum thing from Getz is a piece of garbage. I came up with something my first week in fire protection that I’ve been using ever since 1995. Also, I don’t DOT test Ansul extinguishers because they’re not DOT cylinders
@madaneoulix1312
@madaneoulix1312 2 жыл бұрын
I work for big company that does this.. we always pressure to the end of the green just before so people can get as much use out of it as possible during an emergency.. and the hydrostatic testing in my state's only 30 seconds I find that interesting you guys have to do it for a minute
@alexrodriguez8714
@alexrodriguez8714 6 жыл бұрын
Thank you so much for this video. I just start a new job like this one.
@alvagood2693
@alvagood2693 6 жыл бұрын
Test pressures are not all 3 times operating pressures but by the pressure on the label. Not all extinguishers are under USDOT requirements.
@IowaFireControl
@IowaFireControl 6 жыл бұрын
Thank you for your comment and good luck to you and all your endeavors Alex
@jeffiscool1805
@jeffiscool1805 6 жыл бұрын
Good video. Thank you. Long ago I had a relatively small fire get away from me because of an extinguisher that stopped spraying long before it was empty. I honestly never paid much attention to extinguishers before that. Losing most of your possessions, your dog, and almost losing your wife and young son because of a faulty extinguisher is NOT something anyone should ever go through. Just because the gauge is in the green does *NOT* guarantee that it will function as you expect. Buy the biggest extinguisher(s) you can afford, keep it serviced and/or replace it as required. Fire is cruel, lightning fast and unforgiving.
@bigtodd6609
@bigtodd6609 3 жыл бұрын
In Australia they don't put a verification of service collar on them after testing - They only stamp the bottle. Makes you wonder if they're Hydrostatically testing them properly.
@Krajorg
@Krajorg 2 жыл бұрын
I doubt it the majority of people probably just stamp it without doing anything that’s why we use service collars because you have to take the head off in order to put it on
@ghermansizer
@ghermansizer Жыл бұрын
They stamp the co2 bottle with the date and their R.i.n. #.
@daveynorman4979
@daveynorman4979 2 ай бұрын
why when I do a 6yr maintenance sometimes it’s leaks out even when I change the o ring need help?
@joshuahandy2002
@joshuahandy2002 3 жыл бұрын
You are using the wrong Lube for Ansul Sentry Dielectric silicone compound, I like your low pressure hydro machine.
@StephenOkwara
@StephenOkwara 6 жыл бұрын
THANKS FOR THE TRAINING....I Need your Assistance on hydrostatic testing kit for gas cylinders
@yoz1967
@yoz1967 Жыл бұрын
When a unit calls for 585 test pressure but the working gauge sets on 586 or 588 what gets recorded on the data sheet? What gets punched out on the sticker label for the hydro reading?
@samuelarney9224
@samuelarney9224 2 жыл бұрын
I've always wanted to do this for a living just don't know how
@ashleywhatsittoya9345
@ashleywhatsittoya9345 2 жыл бұрын
Didn’t show drying process
@alvaalgood9393
@alvaalgood9393 4 жыл бұрын
Also determine if the extinguisher is or is not regulated by DOT Code of current USDOT regulations.
@corywilliamson61
@corywilliamson61 5 жыл бұрын
nice job!
@khawk7365
@khawk7365 5 жыл бұрын
I'm in Alabama. I am a nicet 1 and 2 alarms and level 1 inspection. What is the certification that I would need to do hydro and 6 year maintenance on extinguishers?
@prlee1
@prlee1 3 жыл бұрын
bravo colleague
@jamiemitchell8746
@jamiemitchell8746 3 жыл бұрын
Great video thanks for posting. Recently started my own business here in Canada Looking for guidance on forms for a 6 and 12 year maintenance
@talhamian
@talhamian 2 жыл бұрын
im in Canada as well and i started this business last year and ive been doing so well. very niche business
@talhamian
@talhamian 2 жыл бұрын
@@ricardovega6252 you just need insurance. I don't think you need a business license
@chasermanx77
@chasermanx77 5 жыл бұрын
Is there a name or band of the device used at the 1:45 mark that blows out the excess powder? Or is that Custom made? I work for a Fire Extinguisher Service company in Maryland and are building out a new room for servicing extinguishers any help would be much appreciated thank you!
@joshwoodsmusic7979
@joshwoodsmusic7979 5 жыл бұрын
Chase Castle they make a vacuum device that you tip the extinguisher over and it sucks the remaining powder. He was using it in the beginning
@ernie5187
@ernie5187 6 жыл бұрын
So the powder gets discharged into the hopper. But what about the nitrogen going into the air in the room? At work we recharge 30-40 5lb. Extinguishers in 6 hours. Is it safe to breath in all that nitrogen? Thanks
@justanotherguy8791
@justanotherguy8791 6 жыл бұрын
By volume, dry air contains 78.09% nitrogen, 20.95% oxygen, 0.93% argon, 0.04% carbon dioxide, and small amounts of other gases.
@ernie5187
@ernie5187 6 жыл бұрын
Greg Dinert....never new that, So is it safe? Is it ok as long as their is good ventilation?
@PimpMyDitchWitch
@PimpMyDitchWitch 4 жыл бұрын
As long as you aren't working with extinguishers while in a cardboard box I think you'll be fine.
@joshuaborem7063
@joshuaborem7063 5 жыл бұрын
I'm going by memory here but I think the Parker O lube is not the correct one for that extinguisher...
@firealarm3915
@firealarm3915 4 жыл бұрын
What is the purpose of doing a hydrostatic test when you could just replace the extinguisher completely for a fraction of the cost?
@PimpMyDitchWitch
@PimpMyDitchWitch 4 жыл бұрын
Because it is not a fraction of the cost. Either you replace an extinguisher every 12 years or you get it tested every 12 years and have it last 50 years.
@user-wq4qm8nj2u
@user-wq4qm8nj2u 3 жыл бұрын
A hydrostatic test is a 1/4 of the price of most new extinguishers unless your buying a junk extinguisher. Secondly it's better for the environment to reuse a perfectly acceptable extinguisher.
@firealarm3915
@firealarm3915 3 жыл бұрын
@@user-wq4qm8nj2u Ah, thanks!
@schnoodle3
@schnoodle3 3 жыл бұрын
@@user-wq4qm8nj2u I wish that were the case for CO2 extinguishers.
@williamwiwczaroski3598
@williamwiwczaroski3598 4 жыл бұрын
My questions to this video... Per NFPA 10 IS IT NOT MANDATORY TO CHANGE ALL PARTS EVERY 6 YEARS? NEW VALVE STEM NEW ORING I mean technically by the video the proper services were not completed due to that nature. If going to show on youtube shouldn't you be 100%?
@PimpMyDitchWitch
@PimpMyDitchWitch 4 жыл бұрын
Every 6 years is an internal inspection to determine whether everything is good inside and out. You only have to replace things that are broken in it.
@tarassu
@tarassu 4 жыл бұрын
What is the cost compared to new extinguisher?
@bertlarsen3202
@bertlarsen3202 4 жыл бұрын
I reckon it's about the same price
@gmc1966
@gmc1966 2 жыл бұрын
We sell new 10 pounders for around 110 bucks or more depending on the brand. A hydro/recharge with new valve and O ring,about 52 dollars
@faridulislamsardar
@faridulislamsardar 2 жыл бұрын
I am tacnichian of fire extinguisher I need a job
@على.المصرىابوابراهيم
@على.المصرىابوابراهيم 6 жыл бұрын
نبي ترجمه للطفايات فوروتش
@user-wq4qm8nj2u
@user-wq4qm8nj2u 3 жыл бұрын
He didn't replace the o ring and there's a lot of wasted movement in this demonstration. Is this how you normally do your tear downs ?
@StevenTYates
@StevenTYates 2 жыл бұрын
2:50 do not exceed 30 seconds during pressure testing. Its not 1 minute
@gmc1966
@gmc1966 2 жыл бұрын
According to NFPA 10 standard, you are required to hold the pressure for one minute
HydroTesting a 4500 PSI Carbon Fiber Tank vs Catastrophic SCBA FAIL!!!
4:48
Airgun Scientist Joe Brancato
Рет қаралды 112 М.
Fire Extinguisher Hydrostatic Pressure Test
22:22
Erick Hernandez
Рет қаралды 42 М.
Thank you Santa
00:13
Nadir Show
Рет қаралды 49 МЛН
За кого болели?😂
00:18
МЯТНАЯ ФАНТА
Рет қаралды 3,4 МЛН
А я думаю что за звук такой знакомый? 😂😂😂
00:15
Денис Кукояка
Рет қаралды 5 МЛН
If people acted like cats 🙀😹 LeoNata family #shorts
00:22
LeoNata Family
Рет қаралды 31 МЛН
How to do a 6 Year Maintenance/Recharge A Fire Extinguisher
15:21
FireAlarmDude5967
Рет қаралды 32 М.
Pipeline Safety: Hydrostatic Pressure Testing - Short Version
3:19
Wake Up Call: Refinery Disaster in Philadelphia
18:02
USCSB
Рет қаралды 2 МЛН
Inspection and testing of fire extinguishers
26:32
Axiom Compliance Learning
Рет қаралды 20 М.
How To Do Hydrostatic Testing Or Pressure Test For Valves | Gate Valve
10:22
How to Hydro Test a scuba tank
5:51
ScubaTech Key Largo
Рет қаралды 23 М.
Extracting Halon From Fire Extinguisher
11:24
Cody'sLab
Рет қаралды 945 М.
Full fire extinguisher collection 2022
18:12
the life safety man of Maine
Рет қаралды 2,2 М.
Mid 80's Chubb Fire Extinguisher Training Film (better sound)
11:40
Thank you Santa
00:13
Nadir Show
Рет қаралды 49 МЛН