Identifying Unmarked 9 Lead Motors - WYE Connection - York Repair Inc

  Рет қаралды 106,944

York Repair Inc.

York Repair Inc.

Күн бұрын

Пікірлер: 25
@urza1989
@urza1989 Жыл бұрын
Extremely helpful! Took a few listens to understand what i was doing with the leads and marking the wires. Thank you!
@aland6642
@aland6642 8 жыл бұрын
Thank you sir!! I'm an electrical engineer student in Canada and this vide helps, thanks again.
@The_Active_Region
@The_Active_Region 3 жыл бұрын
Thanks for the procedure. Worked perfectly.
@fernandobotello1190
@fernandobotello1190 9 жыл бұрын
Nice video, very informative! One question, How can i identify an Unmarked 12 lead motor?. Can i use the same procedure? With what modifications? The leads are the same colors (black) and with no identification. Thanks in advanced!
@babispapageorgiou8499
@babispapageorgiou8499 4 жыл бұрын
Very beautiful video well done. If we have a 12 lead motor and must connected in wye position we follow the same process or is different? Thank you very much
@Jasonuo
@Jasonuo 11 жыл бұрын
7,8, and 9 are the only THREE that can have continuity together.
@philliphammock1804
@philliphammock1804 11 жыл бұрын
thanks this helps a lot and york would be on my list for needs (PH Fabrication)
@Bleedingred99
@Bleedingred99 3 жыл бұрын
Thank you for the video.
@natesmith9203
@natesmith9203 3 жыл бұрын
Great info I used it today
@HmongGuitarPlayer
@HmongGuitarPlayer 8 жыл бұрын
The other end of 7,8,9 connected internally is your internal wye which is numbered 10,11,12.
@callitw
@callitw 5 жыл бұрын
When labeling 7 8 9, does that change the other pairs? If the motor leads were originally labeled as 7 8 9, and you change 7 to 8, 8 to 9, and 9 to 7, will that change which pair is 1&4, 3&6, 2&5?
@callitw
@callitw 5 жыл бұрын
Finding 1&4 - what do yo do if you get two pairs that has similar deflections?
@lJUSTwanaCOMMENT
@lJUSTwanaCOMMENT 6 жыл бұрын
First I would like to thank you for your efforts and for this guide. But the guide is a little confusing. It states that 1 & 4 will have little to no deflection when flashing 7 & 8. Same with 3 & 6 flashing 9 & 7. This is a simple error on your website I assume, yes?
@10swatkins
@10swatkins 4 жыл бұрын
Docs say one thing, Video says the opposite
@romeojr.dacuno1780
@romeojr.dacuno1780 10 жыл бұрын
WYE configuration 3lead has continuity but @ 2: 13 how can you say that leads is 7,8 & 9 you just randomly mark 7,8,9
@btlfn723
@btlfn723 10 жыл бұрын
Yes it is in fact random, reason being that the leads are in fact marked based on the meter readings in relation of these leads as marked...remember that in a 3 phase "Y" connected motor if the rotation is backwards simply swap any two feeder leads. That's why leads 7, 8 and 9 are random....I wound motors in the Navy and this is the very procedure that we used because after the motors were rewound, they have no markings.
@mrchew1982
@mrchew1982 9 жыл бұрын
Each of the three phase windings is essentially the same as the others, just located at a different position in the motor, thus it doesn't really matter which winding set gets assigned which number. The only important thing is the windings in relation to each other, which is what this test sorts out. kind of like arbitrarily deciding to draw a line on the ground and call it zero, measuring everything from that line... This is a great video btw, although a bit dense. After watching this 4 or five times I got crazy enough to try it, and IT WORKS! To the people who made this happen, Thank You! I will certainly remember York Repair in the future for any motor rebuilds beyond my meager capability! Great advertising!
@sparjhonarnejo6234
@sparjhonarnejo6234 6 жыл бұрын
Hi Sir, Would it affect the test or the motor itself if i use a 24Vdc?
@minareyes6635
@minareyes6635 7 жыл бұрын
Hello sir good evening, i just only ask a question, the voltmeter set in 2.5v dc? Or 2.5v ac? It is dc? Just correct me if I'm wrong, thank you sir. I just take a screenshot.
@lJUSTwanaCOMMENT
@lJUSTwanaCOMMENT 6 жыл бұрын
PLEASE HELP! I keep getting 2 equally strong deflections and 1 weak deflection in all combinations. What do it do???
@gitzed
@gitzed 12 жыл бұрын
You found the three leads that had continuity and randomly marked them 7-8and9. Does it not matter which ones you select as 7-8 and 9.
@georgeduckworth4452
@georgeduckworth4452 3 жыл бұрын
No if they have continuity they must be connected
@jonreitz8838
@jonreitz8838 3 ай бұрын
My understanding is you may be off but they will rotate in the correct direction when found this way. At least that's the experience I've had with my students.
@has997
@has997 5 жыл бұрын
Hi . Can you help in identifying 3 phase 6 leads wye please ?
@theotrotchie
@theotrotchie 3 ай бұрын
You have such a mess there, can't make sense of it.
Wye Motor Lead ID - 9 Lead Dual Voltage
20:14
Zack Hartle
Рет қаралды 10 М.
Identifying Unmarked 9 Lead Motors - Delta Connection - York Repair Inc
5:42
Шок. Никокадо Авокадо похудел на 110 кг
00:44
An Unknown Ending💪
00:49
ISSEI / いっせい
Рет қаралды 46 МЛН
Will A Guitar Boat Hold My Weight?
00:20
MrBeast
Рет қаралды 194 МЛН
How 3 Phase Power works: why 3 phases?
14:41
The Engineering Mindset
Рет қаралды 988 М.
Delta Motor Lead ID - 9 Lead Dual Voltage
13:59
Zack Hartle
Рет қаралды 10 М.
Identifying leads on an unmarked 9 lead WYE connected Motor
11:03
AccessToPower
Рет қаралды 59 М.
Axial Fan Motor Bearing Replace Work - AC&R World
11:27
AC And R World
Рет қаралды 35 М.
How to Read a Motor Nameplate
9:46
VFDs.com
Рет қаралды 238 М.
Part 5(a) Polarity Test ( Theory) of a 3 Ph. Induction Motor
15:59
clinton netto
Рет қаралды 8 М.
How 3 Phase Transformers Work - why we need them
24:24
The Engineering Mindset
Рет қаралды 779 М.
Dual Voltage, 3 Phase, 9 Lead Wye Motor Connections #1
24:15
Pete Vree
Рет қаралды 62 М.
Шок. Никокадо Авокадо похудел на 110 кг
00:44