Extremely helpful! Took a few listens to understand what i was doing with the leads and marking the wires. Thank you!
@aland66428 жыл бұрын
Thank you sir!! I'm an electrical engineer student in Canada and this vide helps, thanks again.
@The_Active_Region3 жыл бұрын
Thanks for the procedure. Worked perfectly.
@fernandobotello11909 жыл бұрын
Nice video, very informative! One question, How can i identify an Unmarked 12 lead motor?. Can i use the same procedure? With what modifications? The leads are the same colors (black) and with no identification. Thanks in advanced!
@babispapageorgiou84994 жыл бұрын
Very beautiful video well done. If we have a 12 lead motor and must connected in wye position we follow the same process or is different? Thank you very much
@Jasonuo11 жыл бұрын
7,8, and 9 are the only THREE that can have continuity together.
@philliphammock180411 жыл бұрын
thanks this helps a lot and york would be on my list for needs (PH Fabrication)
@Bleedingred993 жыл бұрын
Thank you for the video.
@natesmith92033 жыл бұрын
Great info I used it today
@HmongGuitarPlayer8 жыл бұрын
The other end of 7,8,9 connected internally is your internal wye which is numbered 10,11,12.
@callitw5 жыл бұрын
When labeling 7 8 9, does that change the other pairs? If the motor leads were originally labeled as 7 8 9, and you change 7 to 8, 8 to 9, and 9 to 7, will that change which pair is 1&4, 3&6, 2&5?
@callitw5 жыл бұрын
Finding 1&4 - what do yo do if you get two pairs that has similar deflections?
@lJUSTwanaCOMMENT6 жыл бұрын
First I would like to thank you for your efforts and for this guide. But the guide is a little confusing. It states that 1 & 4 will have little to no deflection when flashing 7 & 8. Same with 3 & 6 flashing 9 & 7. This is a simple error on your website I assume, yes?
@10swatkins4 жыл бұрын
Docs say one thing, Video says the opposite
@romeojr.dacuno178010 жыл бұрын
WYE configuration 3lead has continuity but @ 2: 13 how can you say that leads is 7,8 & 9 you just randomly mark 7,8,9
@btlfn72310 жыл бұрын
Yes it is in fact random, reason being that the leads are in fact marked based on the meter readings in relation of these leads as marked...remember that in a 3 phase "Y" connected motor if the rotation is backwards simply swap any two feeder leads. That's why leads 7, 8 and 9 are random....I wound motors in the Navy and this is the very procedure that we used because after the motors were rewound, they have no markings.
@mrchew19829 жыл бұрын
Each of the three phase windings is essentially the same as the others, just located at a different position in the motor, thus it doesn't really matter which winding set gets assigned which number. The only important thing is the windings in relation to each other, which is what this test sorts out. kind of like arbitrarily deciding to draw a line on the ground and call it zero, measuring everything from that line... This is a great video btw, although a bit dense. After watching this 4 or five times I got crazy enough to try it, and IT WORKS! To the people who made this happen, Thank You! I will certainly remember York Repair in the future for any motor rebuilds beyond my meager capability! Great advertising!
@sparjhonarnejo62346 жыл бұрын
Hi Sir, Would it affect the test or the motor itself if i use a 24Vdc?
@minareyes66357 жыл бұрын
Hello sir good evening, i just only ask a question, the voltmeter set in 2.5v dc? Or 2.5v ac? It is dc? Just correct me if I'm wrong, thank you sir. I just take a screenshot.
@lJUSTwanaCOMMENT6 жыл бұрын
PLEASE HELP! I keep getting 2 equally strong deflections and 1 weak deflection in all combinations. What do it do???
@gitzed12 жыл бұрын
You found the three leads that had continuity and randomly marked them 7-8and9. Does it not matter which ones you select as 7-8 and 9.
@georgeduckworth44523 жыл бұрын
No if they have continuity they must be connected
@jonreitz88383 ай бұрын
My understanding is you may be off but they will rotate in the correct direction when found this way. At least that's the experience I've had with my students.
@has9975 жыл бұрын
Hi . Can you help in identifying 3 phase 6 leads wye please ?
@theotrotchie3 ай бұрын
You have such a mess there, can't make sense of it.