Great teaching 🤩🤟🏻🙌... Keep it up... And thanks.... Plz make all the topic of 3 phase induction motor
@santoshtamang83846 жыл бұрын
Handle is use just to start n run the motor not to stop. to stop motor push button is use where nvc is connected in series .....and I think if voltage increases current decreses ....but ur explanation is enough good 4 beginner...all starter r use for reducing the starting current ....N safety 4 motor n panel.....
@kuleshwarkumar38563 жыл бұрын
Best explanation sir🙏 👌👌
@madhurigupta730 Жыл бұрын
Sir please ab special machine padhaiye
@suraj.mishra6 жыл бұрын
Easily explained....Thanku so much for the video Sir.
@DIXITAGGARWAL933 жыл бұрын
At 14:35 I dash is being used which is not being described or may be confused with the current symbols .
@hukamsingh92982 жыл бұрын
Motor ko sir star me connect kre ya delta me motor ratting 415volt 110kw h
@chiragchaudhari50315 жыл бұрын
so simple explanation...tvmuch sir....please sir auotransformer control circuit pe video banaie
@vishalsirsath34263 жыл бұрын
Sir fir motor ke terminal box mein star connection hoga ya delta ? Kyun ki wire 3 hi jarahi hai fir motor delta mein kese run karegi? Plz plz plz sir reply jarur karna? 😭😭😌
@aakashyadav65153 жыл бұрын
Torque reduce hoga...!? Last mai kya tha wo kch samja nahi!!
@mioVanz5 жыл бұрын
Thankyou so much ❤️
@patelkunjal40245 жыл бұрын
Under volage relay and over load relay to hum star delta me use kar sakte hai
@dheerendratiwari33754 жыл бұрын
Current transformer pe ek vidio banyiye sir ji working principle
@nadeemsaddeek88253 жыл бұрын
Great man
@mdsamiullah95722 жыл бұрын
Sir Advantage and application description me nhi hai
@pankajsanwal20102 жыл бұрын
भाई जब आप कर्रेंट ratio calculate करते हुए x square find out करते हो तो वहाँ से आप बात बदल लेते हो जैसे जा छुड़ा रहे हो और torque का base proove करने की कोशिश करने लगते हो । आपने जो कहा कि direct supply provide करने पर जो current carry होने लगती है वक़्ह autotransformer के comparision में बहुत ज्यादा होती है । आखिर कितनी ज्यादा होती है ? आखिर आप फॉर्मूला derive करके वहाँ तक पहुँचे हो तो सबसे जरूरी बात को तो explain करो चाहे आधार 2 की बजाय 1 ही रखो । I hope you will try to understand my concern about your explanation .
@prithwishdey67084 жыл бұрын
Please make one video on ICM-220 lock out relay Waring cannection.
@mohamsadique25726 жыл бұрын
Sir starting current jyada kyu hota h
@ameytaru71455 жыл бұрын
At starting rotor acts as blocked rotor (short circuit condition in secondary), and due this starting current is high.
@hukamsingh92982 жыл бұрын
Auto transformer starter me auto transformer ki star connected nhi krega to kya hoga
@sibakumar10535 жыл бұрын
Starting se running manually karna padta Hain Kya??
@AlokYadav-hr5im4 жыл бұрын
Graceful ♥️
@karanmunda60504 жыл бұрын
Auto transformer starter can use in more than 20HP motor
@Fitwithrc_4 жыл бұрын
Sir ye x² ka smjh ni Ya ki ye stnd kya krta h?
@prithwishdey67084 жыл бұрын
Please make one video on part winding cannection
@rizwanrajput83426 жыл бұрын
sir pdf notes kb provide kr rhy transformer r induction moter
@shriyamsingh54466 жыл бұрын
single phase induction motor or synchronous motor pe video kb banayenge sir?
@Electricalpaathshala6 жыл бұрын
Induction motor abhi finish ho jaayega next week me with numericals .. uske baad synchrounous machine start krenge
@dilipparmarbusinessconsult37365 жыл бұрын
How to check phisicaly check auto transformer How to check Winding ok or Not ok.
@manpreetkumar16363 жыл бұрын
Thx
@vishwanath47974 жыл бұрын
3phase supply hote h but delta h only 2phase show ho rhe h 😩smaj m nhe aya sir
@sajaljana20114 жыл бұрын
Pls video upload topic is Transducer
@siddharthasatyakam59084 жыл бұрын
I couldn't find the advantages. Please help
@kirshnakumarpachahra56745 жыл бұрын
Bhai diagram ed mein chal jaega
@bheemkedivane9732 жыл бұрын
Hiii
@shivamhiet714 жыл бұрын
Plz send ...PDF 🙏🙏🙏🙏
@idarindam29525 жыл бұрын
Kindly explain about tpdt switch
@dip77492 жыл бұрын
If we reduced voltage by auto transformer.. So current will high.. Bcs power is constant...