Sir, please make video on new stability chamber qualification.
@pravinsingh81703 ай бұрын
Kon si guidelines me sir daily karte hai
@vineshvats84579 ай бұрын
Sir passbox LAF cabinet ko rest or operation me kis grade me NVPC krna chahiye
@PHARMAVEN9 ай бұрын
It should be equal to cleaner grade of area where it opens
@anithakannaiyan3910 ай бұрын
Very useful video sir , I have a question I understood about the critical points as you had described it already in this video, so sir what would be the non critical sampling location/points? Thanks
@PHARMAVEN10 ай бұрын
Non critical locations are those where there are no open sterile containers, no interventions, no fillings or stoppering is done, For example, after vial is sealed, there is no exposure of product to open atmosphere hence that section is not critical In area, where there is no man material movement, material storage , for example, corners of room, locations near filling machine where there is no intervention or operator activity are non critical locations We don’t have to do any monitoring on non critical locations
@anithakannaiyan3910 ай бұрын
Great , thanks so much sir for the reply.. it was very helpful
@PHARMAVEN10 ай бұрын
I have also prepared video for that
@mahmudali964810 ай бұрын
Can we use DI water in autoclave for steam generation
@PHARMAVEN10 ай бұрын
Does your autoclave is with in built steam generation?
@traverse64279 ай бұрын
Table A.1 is applicable for non-viable locations or both viable & non-viable both ?
@PHARMAVEN9 ай бұрын
Only non viable
@harisabdurrahman82546 ай бұрын
What if take the measurements in cubic feet ? Will the sampling time be reduced?
@PHARMAVEN6 ай бұрын
I have a shorts video on that
@pravinsingh81703 ай бұрын
Sir satick condition me koi activity nahi hoga but agar ham a grade me em kar rahe hai to b grade me ham activity kar sakte hai
@PHARMAVEN3 ай бұрын
Yes When you are working under Grade A, you can also work in grade B but all activities under Grade A are aseptic simulation and must be done in media fill