Here, he connected a 3ph motor to a variable frequency drive VFD and wired an external potentiometer to adjust the speed. The number on the VFD display is the frequency in Hz which is how the VFD is controlling the motor speed by varying the AC frequency. One of the outputs on the VFD controller is a 0-10V signal that matches the frequency range. That freq range can be set in the VFD, even beyond 60Hz, and can be upwards to 400Hz causing the motor to run faster than the name plate speed but loosing shaft torque. The digital meter (the separate box with the display) has an input range of 0-10V (and others). It can be programmed to output on the display a number range that is a multiple the voltage input. Here it was a factor of 6X so that with a 10V input it reads 60 on the display. That allows the separate display to be mounted anywhere. It was a good project and seemed to work perfectly. Good job!
@bdmmolinamolina3 күн бұрын
exelente lo Intentare para un power flex 40 A/B
@carlol6982 жыл бұрын
MUCHAS GRACIAS 👍👍
@jacobgutierrez87833 жыл бұрын
Quiero mas videos de su trabajo..
@arturotasaycoavalos33774 ай бұрын
Excelente video, muchas gracias, disculpa que modelo de potenciómetro estás usando?
@georginanoeliasuyolaime29503 жыл бұрын
Interesante me interesa saber más 🤔
@TheYepesito3 жыл бұрын
Buenazo
@edu73673 жыл бұрын
desde colombia, saludos, cuales son las bornas de control que se utilizan y donde se puede conseguir en mi pais
@robert5742 жыл бұрын
Could you measure the outside diameter of the potentiometer you used (around the silver part)? I looks a lot larger than the ones I've seen for sale. I just purchased one and it was about 27-28mm around the outside to fit into a 22mm hole. I wanted a larger one for a project.
@habrangutierrez11032 жыл бұрын
Diámetro de la plateada: 31mm. Cuello de montaje: Rosca 22mm.
@victorianohenándezhernández11 ай бұрын
Donde puedo encontrar el indicador digital, o que modelo es? Soy de México
@hugohernandez21283 жыл бұрын
@ELECTRONICA INDUSTRIAL PRÁCTICA buenas noches saludos y las terminales que van del VDF al indicador cuáles son? Habrá algún indicador que muestre las RPM en lugar de Delos Hz?
@electronicaindustrialpract70012 жыл бұрын
Los VDF tienen salida Analógica: 0 a 10Vdc. Hay que identificar dichas terminales. En el VDF del vídeo son las terminales CM y AM CM se conecta al panel en terminal 5(COM) AM se conecta al panel en terminal 2(señal)
@electronicaindustrialpract70012 жыл бұрын
Perdón por la demora Para pronta atención +591 3 60005774
@electronicaindustrialpract70012 жыл бұрын
A la 2da pregunta Se puede programar para que el Indicador de Panel muestre RPM...
@habrangutierrez11032 жыл бұрын
El mismo Indicador de Panel se puede configurar para RPM. Hay un parámetro donde se asigna en el Indicador correspondiente a: Min.: 0V Max.: 10V Identificar el RPM del Motor, ejemplo: 1200 rpm. Min.: 0 Max.: 1200
@carlol698 Жыл бұрын
Excelente campeón.
@roneigomes376610 ай бұрын
Tem como ligar dois em paralelo
@hugoreyescid1873 жыл бұрын
Disculpa tendrás algún diagrama de conexión?
@luismedina-kf5ed2 жыл бұрын
Hola, como se llama ó modelo del indicador digital, saludos desde Venezuela.
@electronicaindustrialpract70012 жыл бұрын
Código: MP6-4-DV-NB Marca: Hanyoung Nux
@electronicaindustrialpract70012 жыл бұрын
Se llama: Indicador de Panel (Configurable)
@TheYepesito3 жыл бұрын
Estimado amigo dónde puedo conseguir el indicador digital?
@electronicaindustrialpract70013 жыл бұрын
Buenas muchas gracias por el comentario. De dónde nos escribe?