Installing Mini Split Surge Protector

  Рет қаралды 4,597

Joe's Garage

Joe's Garage

Күн бұрын

Пікірлер
@AlexBianco100
@AlexBianco100 Жыл бұрын
My only tip would be to crimp on some wire ferrules instead of putting the stranded ends directly in the disconnect lugs. Stranded aluminum wire can loosen over time.
@jimdavis9581
@jimdavis9581 Ай бұрын
Finally, a clear and concise video on how to install this surge protector the right way! Thx
@AlexBianco100
@AlexBianco100 Жыл бұрын
Nice addition! I might do this for my dad's mini-split.
@orabuntu-lxc3389
@orabuntu-lxc3389 29 күн бұрын
One of the best install videos I've seen for the AG3000 with good detail. One detail though. Apparently after you shutoff the breaker indoors you confirmed no power at outdoor box because you heard the unit simultaneously shutoff when you flipped the breaker. The hot wire at the outside box should be checked dead with a non-contact circuit tester before proceeding with install. Turning off a breaker (might have flipped the wrong breaker switch, for example) is not really a sufficient safeguard that power is actually cut off. Always test with a non-contact line tester before beginning servicing.
@alejjakdarkok8174
@alejjakdarkok8174 7 ай бұрын
great video thanks for mentioning the difference between 120 and 240
@ROYALPRIX
@ROYALPRIX 6 ай бұрын
I'm told these are great for solar setups too, avoiding surges for inverters etc. Great vid.
@orabuntu-lxc3389
@orabuntu-lxc3389 29 күн бұрын
Alot of the videos for the AG3000 show the wires from the AG3000 being run right into the terminals of the disconnect. Is using pigtails better practice? I'm guessing the idea behind using the pigtails and wire nuts is to keep the surge away from the terminals bar so that surge never gets anywhere near the actual terminals of the cutoff. That totally makes sense to me and seems like not only preferred install method but actually also is the correct install method, whereas running the AG3000 wires right into the terminals connectors would be incorrect installation?
@fl_sim0038
@fl_sim0038 7 күн бұрын
You should never use more than 1 wire in the disconnect lugs same as all lugs in a panel box according to the NEC.
@emyunster
@emyunster 2 ай бұрын
Disconnect lines, there are wires coming from condenser?
@DanMercado-t5m
@DanMercado-t5m 5 ай бұрын
Does Midea mini split have a surge protector that fits inside the unit?
@peppi7777
@peppi7777 6 ай бұрын
Thanks for the video. Just installing mine as well ,same model. May I ask does it make a difference installing the surge protector on the load side instead of the line side ? Would it protect the unit specifically by putting on load side of the mini split? Thanks
@dinachoueiry6073
@dinachoueiry6073 3 ай бұрын
So I thought this had to be run parallel from the hvac side. And also you cantcut those wires supposedly
How to Install Surge Protector on Air Conditioner Easy
8:01
Word of Advice TV
Рет қаралды 14 М.
Watch This Before You Buy a Mr Cool Mini Split
35:24
LRN2DIY
Рет қаралды 292 М.
Жездуха 41-серия
36:26
Million Show
Рет қаралды 5 МЛН
번쩍번쩍 거리는 입
0:32
승비니 Seungbini
Рет қаралды 182 МЛН
Surge Protectors Can Save You From Costly Repairs!
12:58
World of HVAC
Рет қаралды 3,4 М.
Install an EMP Shield Whole House Surge Protector Safely & Properly
8:11
The Home Improvement Channel
Рет қаралды 29 М.
Mars Exploded Surge Protector
20:53
Michigan Heating Guy
Рет қаралды 8 М.
Never Install A Whole House Surge Protector Until Watching This!
6:35
proclaimliberty2000
Рет қаралды 30 М.
Multi-zone split type Air Conditioner installation
16:49
craftsman tv
Рет қаралды 495 М.
DIY Mini Split Install - All the Things Nobody Shows You
33:25
LRN2DIY
Рет қаралды 2,2 МЛН
Pioneer Mini Split FULL DETAILED DIY INSTALL
1:18:11
Help Me DIY
Рет қаралды 141 М.
How to Leak Test an AC With Nitrogen Pressure
8:00
HVAC School
Рет қаралды 242 М.
Жездуха 41-серия
36:26
Million Show
Рет қаралды 5 МЛН