We have been insulating our slab with high density foam and laying a vapour barrier on top to stop radon for years in the north.
@cheeseburger92323 жыл бұрын
You in a cold climate
@christophergruenwald50543 жыл бұрын
You should put your vapor barrier below the foam so the insulation is on the dry side. Foam can slowly take on water from hydronic pressure.
@sommerers23 жыл бұрын
@@christophergruenwald5054 The reason he doesn't do that is because the foam will float. I'm pretty sure either Matt or This old house pointed out why you put the barrier on top. You could put another barrier so there is one above and below to accomplish what you are thinking, but then again I don't even working in the construction industry, just enjoy the videos.
@an7h0ny883 жыл бұрын
@@sommerers2 You're right mostly. We put the vapour barrier on top of the foam to prevent water being trapped under the foam. Usually we place the foam, tape seams, then 6mil poly and tape seams. This way if it rains the foam stays dry, water can't get beneath the foam and be trapped between the poly and foam. Otherwise I don't think it matters much.
@grilledcheeseeater34433 жыл бұрын
ive never heard of this turns out its a big deal thank you
@Firestorm6373 жыл бұрын
I own a steel frame quad level house with 6 inch commercial floor pours. I love the strength of steel vs wood. Walls are true with no noise with high winds. I wish more steel frame homes that are recyclable. Enjoy your build
@pcatful2 жыл бұрын
The detail you go into and the attention to detail is incredible.
@joshuaszeto3 жыл бұрын
That is a really big home! I would love to see regular update videos and see how it progresses.
@josephverbosiii57643 жыл бұрын
Some crazy money in this project!
@steveb3653 жыл бұрын
I suppose anyone that can afford to build right now can also afford $10k to keep out moisture and termites
@ZeoCyberG3 жыл бұрын
@@steveb365 Some statistics to consider... According to the United States Department of Agriculture (USDA)... -U.S. residents spend more than $1 billion per year on Formosan termite control alone -Homeowners in the U.S. spend roughly $5 billion per year on combined termite control and termite damage repair costs -Altogether, termites cause damage to as many as 600,000 homes each year in the United States And, according to Texas A&M AgriLife, "Wooden structures in Texas have more than a 70 percent chance of being attacked by termites within 10 to 20 years of construction if they are not properly protected by a chemical or physical barrier" Add, while $1-$2 Billion a year in property damage is caused by termites. Most of this damage is not covered by standard homeowner insurance policies...
@grahamstefaan3 жыл бұрын
It's the real rebuild...aka, don't all you simps build like this?
@rickrudd3 жыл бұрын
600 yard slab!
@ProctorsGamble3 жыл бұрын
A fool and his money are soon separated
@fernandoserrano93933 жыл бұрын
The insulation on the floor will keep the house cool in the summer and warm in the winter. I live near Dallas and the floor is warm in the summer and cold in the winter. The apartment floor was very cold during the February freeze and I had to raise the thermostat temperature as a lot of heat was lost through the floor.
@HistoricHomePlans3 жыл бұрын
Matt - A whole episode on termite strategies would be great. You've covered it in bits and pieces in other videos. With our climate warming we're seeing termites farther and farther north. Soon the entire country will be needing to take these precautions.
@nrao89773 жыл бұрын
"Board form concrete" is also called "Exposed concrete" - made famous by French architect le Corbusier. Used extensively in Indian city of Chandigarh, Punjab (1951). Indian Institute of Management, Ahmedabad, architect Louis Kahn, also used exposed concrete extensively. Old stuff. Need to treat the surface of exposed concrete so that in humid weather - like Austin, TX - moss, fungus growth is restricted. Else it looks very ugle.
@buildshow3 жыл бұрын
Excellent! Thanks
@bert27543 жыл бұрын
@@buildshow do you still recommend Pango Wrap as a physical termite barrier?
@joepmeloen33733 жыл бұрын
I agree, it needs a sealer. Also, be sensible with a powerwasher. Ive seen a few examples were it lost a lot of that nice detail and texture.
@townsendliving97502 жыл бұрын
I'm doing exposed concrete on the interior, all the floors and through the house on the walls
@nrao89772 жыл бұрын
@@townsendliving9750 need to be careful on the interior walls. Exposed concrete takes on the exact surface texture of the forms. If the form is wooden then expect protrusions and sharp edges. Not good if people brush themselves against such a wall.
@SequoiaElisabeth3 жыл бұрын
Wow, what an impressive house. I love the decoupled concept for flooring and the heat sink will be a blessing.
@malavoy13 жыл бұрын
That was a house? From the size I thought it was an apartment complex, complete with sheet metal barn 😁
@ncbarndobuild3 жыл бұрын
Getting ready to do something very similar in NC. Foundation with stem wall and slab poured inside the foundation. Concrete guys here think I am crazy. Glad to see this video. Thanks Matt!
@apscoradiales3 жыл бұрын
Double concrete slabs are not really necessary UNLESS you want a ground and polished finish. If you are doing a porcelain tile or hardwood or laminate floor finish, you can easily do a single slab, and will cost you a lot less than double slab. Here is what you do; level off the dirt and make sure that it's proof-rolled, place compacted gravel - thickness and size of gravel, plus compaction as per your structural engineer (don't skip him!!!), put rigid styrene insulation on top of the gravel (two or three inches of Strofoam SM is plenty - has a compressive strength of 25psi), then put 4mil polyethylene vapour barrier on top of insulation, then do the concrete. Don't use 6mil - it's too thin. You can skip the polyethylene if you seal all the styrene joints - the styrene insulation can act as a vapour barrier, but with so many joints and gaps, it does not act as one proper vapour barrier. In terms of concrete slab reinforcing, just use 6x6 6/6th wire mesh. This is a simple slab-on-grade construction. Now, if you have to "reinforced structural slab", then you must talk to your structural engineer. Don't try to save a few bucks by skipping him - he will save your ass from potential future problems. Also, make sure there is some insulation between your concrete slab and the "stem wall" to act as a thermal bridge. If you don't do that, your slab may heave at edges from the frost or the edges will be hotter or colder than the rest of the slab. Reinforce the stem wall too - structural engineer is your best friend here as well. DO NOT depend just on the contractor(s); they may screw you up big time!!!
@ncbarndobuild3 жыл бұрын
@@apscoradiales I will only be doing a single 4”slab pour and some other slight differences from what Matt shows. A structural engineer designed and sealed my plans based on what I wanted. I totally agree with you on having plans by a licensed engineer. To expensive to not do it right the first time.
@SteveP-vm1uc3 жыл бұрын
Did you say 600 YARDS????????? HOLY SHIT!!!!!!!!!!!!!!!!!!!!!!!
@davidfleuchaus3 жыл бұрын
600 cu yards = 16,200 cu ft 1 cu yard = 27 cu ft (3’x3’x3’) If the slab is 12” thick then this is a 16,200 sf house! But I’d guess the two slabs added together are more than 12” thick so, less than a 16,200 sf house but still huge.
@joev25673 жыл бұрын
Looks like about 3 yards per worker on site. lol
@R2Mike5 ай бұрын
In my are that would be a out 154,000 just for the concrete. 257 a yard here
@infiniteadam73523 жыл бұрын
These days I think its wise to have the slab at least 2 feet above grade, just incase of flooding. I can't believe they got 17 inches of rain from one storm in Tennessee this week, the weather seems to be getting more intense...
@antoniotulum47763 жыл бұрын
some areas of texas dont get flooded, only in cities and in basins it gets flooded..remember the foundation seemed pretty much high...but yes, always better to play it safe
@mr.g9373 жыл бұрын
@@antoniotulum4776 not even during hurricane Harvey?
@Dudeinator3 жыл бұрын
@@mr.g937 yes texas is a huge state.
@antoniotulum47763 жыл бұрын
@@mr.g937 did you see the place the property was at? i doubt it gets flooded there, but anyways , the foundation was pretty big... what usually gets flooded in texas are cities due to poor evacuation systems ... even in a tropical storm (hurricanes are hard to get inland (that place looks like austin or some place around san antonio)
@L0rdEsedess3 жыл бұрын
@Infinite Adam - I live in TN not to far of a Drive from that Flooding that you spoke of & had family that was in it...Luckily they were O.K. but yeah that was so RANDOM for that have had happened.
@SirPoofyPants3 жыл бұрын
Having rebar in the center doesn’t add strength. You want it in the tension zone, which will be towards the bottom or top, depending on your loading. Lifting the rebar on chairs instead gives your tensile reinforcement a protective concrete cover from moisture. Concrete inevitably cracks at the tension face. So you want cover so that the micro cracks don’t allow the rebar to become exposed.
@Witcold3 жыл бұрын
Exactly. Sometimes there are even two layers of reinforcement for downwards and upwards bending forces. Also there is a minimum distance between the rebar and concrete edge for corrosion protection, as originally mentioned.
@callmeishmael74523 жыл бұрын
@@Witcold there are tensile forces running top and bottom all the time .every time there is a gravity point or spread load the surrounding TOP face ( or steel if it’s there) is in tension. The steel in the centre is very good practice though two chords are better but mostly not necessary. Also concrete has micro cracking through the surfaces which constantly open and close though most are not capillary.
@altiplanalberto99613 жыл бұрын
@Sirpoofypants, your comment is correct. But what I believe Matt meant is that they would have the rebar in the center so that the tensile strengths will be evenly distributed and prevent cracks in the concrete. This top concrete layer is not taking the main loads, remember that underneath the insulation lays the foundation slab.
@callmeishmael74523 жыл бұрын
@@michaelhaidee The second the slab flexes the neutral axis shifts. It is indeed very effective to have steel in the centre of any slab-unless there is zero or negligible load. And in a four inch slab it can go nowhere but the centre.
@callmeishmael74523 жыл бұрын
@@michaelhaidee back to your text books.
@pin653713 жыл бұрын
I'll have to keep that Milwaukee vibrator in mind come Valentines day.
@ruelsmith3 жыл бұрын
I work in commercial construction in Ohio/Kentucky and this is the way all slabs are poured. Usually it gets 6 inches of compacted gravel with 1-1/2 to 2 inch pink foam insulation and a plastic vapor barrier on top of it and rebar and a wire mesh on top of all that. They also put foam around the perimeter of the foundation below grade.
@Oldguard_83 жыл бұрын
I would love to see the finished build, look forward to you content Matt thank you!
@nemo2273 жыл бұрын
Here, Monterey Bay coast, we bought our new house in 1970, slab floor. It's very quiet, warm enough, never cold, carpeted and it is practically ideal for our climate. If I was going to build a new home I would build with a concrete slab on grade.
@coachhoiidexplains363 жыл бұрын
Could you do more cost breakdowns of projects? Like cost to client. There's a lot of variability, but it'd be great to see some real numbers and what can cause that variability.
@dmitry64722 жыл бұрын
Looks like around ~ crazy expensive!
@CrustyAbsconder3 жыл бұрын
Less than 90 years ago, my great-grandparents in deep east Texas where still living in a house of 2 rooms with a central outdoor covered walkway, made entirely of local rough-cut lumber. They had 11 children, and there were often semi-permanent guest, and the pig slept with them on the feather-bed.
@techone85683 жыл бұрын
Let me guess. The house had an insulated slab foundation.
@YSLRD3 жыл бұрын
😁Thx My parents (early 20th century) each spent part of their lives in dirt floor cabins. In the 1960's, visiting my grandparents included daytime using the outhouse and a chamber pot for little ones at night. Also a hand water pump.
@disqusrubbish5467 Жыл бұрын
You're Eva Gabor?
@eh_bailey3 жыл бұрын
Great work Matt. I'm loving the details
@GoldsConcrete2 жыл бұрын
Insulated floors of any kind are the best !
@UponorNA3 жыл бұрын
Great project. Can't wait to see the final build.
@HistoricHomePlans3 жыл бұрын
4:48 Beautiful concrete work! Matt, you really know how to get the best out of your crews and subs. It must be inspiring to work on your projects.
@davidblalock99453 жыл бұрын
That insulation in the slab will be awesome here in Wyoming.
@AndrewBuilt3 жыл бұрын
I though I was just going to see the same old insulated slab. This is on the next level of detail. Glad I took the time to watch it. I don’t think this is the most eco friendly method with all of the concrete. But for a ranch style you are not going to be able to have significant reductions in concrete floor.
@HistoricHomePlans3 жыл бұрын
I agree about eco-friendly. Matt did a video last December I highly recommend. It's a project where they put ONLY a concrete perimeter beam. Then in the floor "slab" area they did compacted gravel, carefully leveled, set insulation/vapor barrier over that, then a double layer of Advantech, and the finish floor on top of that. NO concrete slab! I'd like to see building departments all over the country encourage this. Search Matt's channel. The video is called: Slab-On-Grade INSULATED Foundation (NO Concrete?!) - Part 2
@HistoricHomePlans3 жыл бұрын
Andrew - I just checked out your channel. Very nice! I'm watching one of your videos now. You've got yourself a new subscriber.
@AndrewBuilt3 жыл бұрын
@@HistoricHomePlans thank you. I briefly saw that video with the no concrete slab. It’s an interesting concept, the same way we do brick paver foundations. I’m gonna have to check back in the video and see what the comments say. I think it’s a good idea as long as there are no breaks in the water and vapor barrier. That would be a disaster for basements in the north.
@econodrain70753 жыл бұрын
Been building those insulated slabs for decades in Europe now
@apscoradiales3 жыл бұрын
True. Also, it's in the upper or top layer of slab that you put the heating cables or heating lines in. Lightweight concrete is often used for that top layer. What's also being done is that instead of a top layer being concrete, sometimes people will use cementitious panels such as the Aquapanel by Knauff. It's a dry system, meaning you don't have to wait for the top concrete layer to cure - you start laying floor finished right away.
@apscoradiales3 жыл бұрын
Matt, do you have a section detail at the intersection of perimeter grade beam and the slab? A picture is worth a thousand words, as they say.
@roberto32623 жыл бұрын
My wife says that she wants one of those Milwaukee backpack vibrators. I don't know why. She doesn't even do concrete work. 🤔
@mgoren90872 жыл бұрын
Funny!
@snicks502 жыл бұрын
LMAO
@rppvt2 жыл бұрын
to get the bubbles out
@LeeYang071338 ай бұрын
🥲
@angeloc7002 жыл бұрын
Lake Flato is an excellent architect. Lucky clients for sure!!
@michaelsites14983 жыл бұрын
Like that one time at band camp?!?! We did a slab in Indiana 4” thick poured in on 2 layers of 2” foam running in opposite directions and a plastic 6 mil vapor barrier that was taped all the way around as well as seems.... I don’t know that I’ve ever seen a slab sandwich but hey if it’s out there my man man won’t fail to bring it to you 👉🏼Onnnnn!!!! The Build Sow!!!! In my best Matt Risinger voice ever!!!! 😝😂😂😂
@robertdean93923 жыл бұрын
Little tip on concrete, when concrete is mixed at.plant, order it with zero injected air during mixing process. We have learned that it pretty much eliminates the need for vibration during pour and creates almost zero air bubbles in slab. It also creates a good environment for finishing the slab with a better look. Take care and see you on the next video.
@an7h0ny883 жыл бұрын
Air entertainment is an important step in creating stronger and more durable concrete. Concrete should ALWAYS be vibrated/consolidated no matter what you're pouring.
@MJ-py3bm2 жыл бұрын
The house is well built. I’m proud of you. You are building a house best possible way for the client….. they should be very happy.
@daniellivingston51683 жыл бұрын
Started using Teri-Mesh in Hawaii in early 1990's along with specialized training by Portland Cement. If memory serves, first in Hawaii. Appreciate Matt in keeping up others informed of great products.
@lyndeesue56073 жыл бұрын
Where do we purchase termitmesh in the Midwest area … kansas ? We wanna pour our slab in 2 weeks😬😳 thanks. Or what’s the next best thing to use ?
@NSResponder3 жыл бұрын
9:15 you don't want the rebar in the center of the concrete, you want it about 1/3 up from the bottom. If it's in the center it won't help much to prevent cracking.
@jpbinva99193 жыл бұрын
Center or edge of rebar at the 1/3 point?
@enriquealdogarcia4850 Жыл бұрын
incredible organized & planified!!!
@everycoLor_3123 жыл бұрын
Nice to see a builder who wants/produces quality😆👍🏼💯
@nashonabo8213 жыл бұрын
My wife wasn't interested in the video until you mentioned backpack vibrators. Guess shes interested in concrete work
@valdius853 жыл бұрын
You do NOT want rebar in the center. This is where it adds almost nothing to the bending strength of the slab. The minimum cover is specified by local reinforced concrete spec and it depends on the usage, concrete mix and rebar diameter.
@jpconnors89522 жыл бұрын
When Matt was talking about locating the rebar at mid-depth he was referring to reinforcement of the topping slab for crack control, not tensile reinforcement for moment capacity of the structural slab. Adding reinforcement in the topping slab is not required structurally but it is best practice to control concrete cracking. ACI 360R-06: Design of Slabs-on-Ground Section 7.5 states “reinforcement for crack-width control only should be at or above mid-depth of the slab-on-ground, never below mid-depth. A common practice is to specify that the steel have 1.5 to 2 in. (38 to 51 mm) cover below the top surface of the concrete. Reinforcement for moment capacity should be at the centroid of the tensile area of the uncracked concrete section.”
@valdius852 жыл бұрын
@@jpconnors8952 Thx for reminding me that!! :)
@Mainetkrause3 жыл бұрын
Matt, love your videos. Keep them coming. I wanted to ask if you could do in-floor heating, or if you even think it would be necessary with the thermal break, with that type of slab detail for those of us if in the north.
@Grunt493 жыл бұрын
Nice house! With a roller rink in it!
@alexpaden93203 жыл бұрын
looking forward to future videos on this build. Looks pretty cool!
@jackzwart86363 жыл бұрын
Have you ever considered using a glass fiber rebar? If I'm the client I'm scratching my head at using steel in 2021 when GFRP is cheaper and stronger and corrosion resistant.
@extraart13 жыл бұрын
I cannot believe you went to that much effort and cost in preparation for an exposed interior concrete floor and didn't install a hydronic radiant heating system! At some point, the homeowners are going to be in someones home that has such a heating system and wonder why the hell, after all that expense, they don't have the most comfortable heat known to man.
@i5k-3 жыл бұрын
Right? even if they didnt want to use it, just future proof. Wasted opportunity...
@alanswanson56423 жыл бұрын
Yep we have hydronic heating basement, first floor second floor and garage. It is silent and draft free. The one down side is you need a separate cooling system
@ProctorsGamble3 жыл бұрын
Love mine!
@jmhowlett3 жыл бұрын
That's what I was thinking, but they probably wanted to save a few bucks.
@M1911jln3 жыл бұрын
Unity Homes / Bensenwood has discussed this in their KZbin videos. Their homes are so well insulated and so tight that radiant heating doesn't work the way it works in a typical home -- the floor would never get that warm because so little heating is required. Also, in a home this large, the cost to install radiant heating would be very large.
@michaelrowley17173 жыл бұрын
Really cool project. Great video
@mcd50823 жыл бұрын
Would love to see this house when it’s built
@jmcdonne3 жыл бұрын
If you know any astronauts on the ISS, ask them to take a peek while they're over Texas - it should be easy to spot.
@Prorex19113 жыл бұрын
Always doing new things. Love it. Thanks for your information!
@ozzmundo13 жыл бұрын
Apply high density closed cell spray foam on top of crushed rock and pour your slab on top of that. The inside of block stem walls can also be sprayed with closed cell foam. This method is not without thermal bridging where the slab intersects with the stem wall, but should do a decent job of keeping out termites while keeping your home more comfortable. Obviously its a hack, but if it works it works.
@dv6613 жыл бұрын
Stem walls are filled solid with cement so can’t fill with foam
@Redwingster3 жыл бұрын
Would spray foam, even closed cell, have sufficient density to bear the load of the finish slap, interior walls, fixtures and furniture, etc? IIRC, closed cell spray foam is typically 2 psi, far lower than the very dense Sub Terra panels.
@jpbinva99193 жыл бұрын
@@Redwingster CCSPF is 2 pounds per square foot, not 2 psi.
@ozzmundo13 жыл бұрын
@@dv661 dude, it’s filled with grout. The foam would be applied to the interior side of the vertical section of the stem wall.
love this idea. Will think about it for my retirement house.
@christophe32813 жыл бұрын
Seems like this method is decades old in Canada. Less the termites of course
@orthonormality3 жыл бұрын
Looking forward to seeing the kellered floor.
@ImDembe3 жыл бұрын
Most slab foundations in Sweden have 10-40cm Cellular plastic for it can handle high loads and wont suck up water and then 10cm or more concrete on top of that. Most of the companys sell pre-made sides that look good and is pre insulated for all sorts of walls that you want to build.
@RR-Alaska3 жыл бұрын
Light gauge steel framing with aerated concrete filled walls is the future you can literally show up to a job site print out all the framing screw it together place your wall panels and fill the cavities with aggregated aerated concrete. And I believe a underutilized construction resource is sprayable ceramic paint what would give it a super insulating quality
@rajeshkanungo66273 жыл бұрын
Curious: how do you handle moisture getting trapped in the foam layer between the two layers of concrete? It could get water logged too.
@Slowhand8712 жыл бұрын
There is plastic vapor barrier on the dirt so no water can migrate up.
@lambition3 жыл бұрын
Would been real nice if radiant floor heating was added to that slab. But, probably not worth in Texas?
@jackjerryloveify3 жыл бұрын
I was thinking the same thing. It is super nice to have a warm floor on a cold day. Seems it would have been very easy to add to this particular build.
@joepmeloen33733 жыл бұрын
Floor heating is brilliant.. but what many people dont know is that (water) floor heating also can be used for cooling. Via air/water heatexchanger or with an ground waterloop. I wonder if floorcooling is used in Texas?
@aleksanteri12343 ай бұрын
Every new construction house in Finland has this.
@oldprankster76063 жыл бұрын
Depending on the location, this may make sense in cold climates. However, insulating a slab in regions with milder winters really doesn't make much sense. The soil tends to stay at a constant moderate temperature all year. Where I live in the Mid-Atlantic, it is not required by code, and the payback would probably exceed the useful lifespan of the building.
@eh_bailey3 жыл бұрын
It feels cold on your feet here (just north of Matt). That is enough for me. 👍
@buildshow3 жыл бұрын
I think Payback is a terrible metric. How about comfort, being a good steward of our resources, or a goal of Net Zero or Net Positive?
@danielhall59113 жыл бұрын
@@buildshow I love your stuff! But...I think this comment is a little out of touch. Payback is THE metric for the majority of households who can't reasonably build to the more sentimental metrics you are mentioning, right? Really, if it was about being a good steward/Net Zero the solution is a comfy pair of organic, sustainably harvested wool socks :-)
@josecito9763 жыл бұрын
@@danielhall5911 any pretense of affordability took flight loooooong ago If ya got the cash to splash… do it! Ain’t taking it with ya the day you leave the house feet first
@BrianKrahmer3 жыл бұрын
it's a myth that the soil stays at a constant temperature all year. if you go deep enough, it does, but the closer to the surface, the closer it tracks the daily average temperature.
@Fredflinstone232 жыл бұрын
They should have radiant floor system added,
@cmm1705263 жыл бұрын
I think Texas needs to start considering both cooling and heating 🤔
@erockhefleyjr68523 жыл бұрын
There is nobody better bro! 👊🏻
@joepmeloen33733 жыл бұрын
Here we insulate the main beam too, then between put a moist barrier on the sand/gravel, insulation, concrete (we call that the workfloor) and on top a dry cement mortar or a self leveling concrete. When radiant floorheating/cooling is installed sometimes an extra thin insulation (or) with a reflective foil is applyed on the workfloor, under the heatpipes.
@apscoradiales3 жыл бұрын
In Europe?
@joepmeloen33733 жыл бұрын
@@apscoradiales yes, Netherlands. The newer style of building that is. Traditionally a simpel small slab is poured under the frostline and then up with 2x masonry with insulation and a ventilated airgap.
@apscoradiales3 жыл бұрын
@@joepmeloen3373 I knew it! Had a friend in NL, Jeroen as well. We were into Bimmers.
@gmart2253 жыл бұрын
I am very detached from the world of building so silly but genuine question: how do brick/concrete walls compare to regular American walls (wood + insulation) - in terms of price and energy envelope? I'd love to watch a video on that!
@davidfleuchaus3 жыл бұрын
After this house is finished and lived for a year or two I think the owners and designers will more easily be able to see two errors: 1. No matter how much insulation is placed under the slab, the slab will always feel cold. If you focus an IR camera on the slab floor and on a rug on the slab floor you would see no temperature change but if you stood barefooted on both portions of the floor you would feel a massive difference in temp. Why? Because of thermal mass. The raw slab floor will absorb a LOT more heat from your foot than will the rug. Although you might feel comfortable at 71F the slab being 71F will suck away heat from your feet at a rate so high that your feet will feel cold. 2. Even a non-heated/cooled building that has a large footprint will keep outside temperatures from reaching the center of the floor. I saw a non-conditioned building in Chicago built over 100 years ago that never needed heat. There was a huge thermal heat sink created by its massive footprint and by its thick walls, massive columns, etc. It never got below 50F. It never got above 78F. Solar gain warmed it and thermal mass laying on the 55F earth kept it cool. No insulation. No HVAC. Crappy old windows. So my point is that the floor insulation in the middle of this house will only be thermally breaking the effect of the 55F ground on the conditioned 71F slab. So, not a mistake per se but an overstatement of benefit. Otherwise, great project. By the way, we have a house up near Chicago that is passively cooled. The house has a large thermal mass first floor floor (6” of concrete with concrete I-beans) that is connected to a 9’ deep basement that is fully below ground. The 55F temp below the frost line cools the basement walls and the basement’s concrete ceiling. All that keeps the house very cool, passively. So next time, grab that earth temp, cool your house with it, bury PEX in the first floor slab for heating. Then all you’d need is a dehumidifier but in TX probably not even that.
@BrianKrahmer3 жыл бұрын
I don't consider heated slabs "cold". Having lived in two houses with basement slabs heated with radiant, I find them very comfortable.
@davidfleuchaus3 жыл бұрын
@@BrianKrahmer Me neither. The house featured here has no radiant heat
@urf8083 жыл бұрын
That land looks like a 100 to 500 year flood zone near that river. Should have elevated that house 15’. For the first floor.
@pulporock3 жыл бұрын
Great content love the insulated slab. I have only seen Termimesh, on the job site in Oz. The link for Halo is pretty crap. Cheers from Oz
@jpeterstme3 жыл бұрын
How good is termimesh? Looking at building and no builder in Melbourne wants to use it. They want to use the chemical barriers around the perimeter.
@dmitry64722 жыл бұрын
Cordless vibrators are the best!
@josephmerritt1411 Жыл бұрын
Curious why there was no insulation for the concrete bath floor? Any thoughts about why they elected to use Halo Subterra versus XPS or EPS or Rockwool?
@rodaliste3 жыл бұрын
Another cool thing about Subterra is that it's also a Radon barrier.
@LogixBrands3 жыл бұрын
Exactly! Halo’s Subterra Plus products are 7 times more effective than the code-mandated 6-mil poly at stopping Radon.
@free2chasehappy3 жыл бұрын
It's nice looking at the cutting edge of house building. Too bad the cost is beyond the reach of most people.
@allan80supra3 жыл бұрын
An example of California money coming to Texas?
@josecito9763 жыл бұрын
Nah it has always been there
@Prorex19113 жыл бұрын
Does California have oil money? We Texans do, just not this one. 😢. Lol. I hear there are rich, stupid rich, and then oil rich. 🤷🏼♂️
@danielcriger92343 жыл бұрын
Seeing alot great details on bug and energy solutions on slab on grade. My question is "radon". Is radon even a thing anymore? No one seems to be adding details for it anyway.
@kc9scott3 жыл бұрын
I don’t know if radon is much of an issue in Texas (I vaguely recall a video on some other channel saying it was a common problem in Georgia), but it seems to me that having a well-sealed vapor barrier in the floor should go a long way towards preventing radon problems.
@oldprankster76063 жыл бұрын
Your county may have a map indicating radon locations. Where I live, the county does have such a map, and there are areas where radon mitigation would be advisable. If so, I would recommend getting a radon test kit. They are inexpensive, and the cost includes analysis by a testing lab. Radon is naturally occurring, but in areas of concentration, it would be worth the cost of the kit.
@oldprankster76063 жыл бұрын
@@kc9scott You would also need to seal any penetrations in the slab, such as plumbing drainage piping. In areas that are radon concentrated, vents installed in the slab are a good mitigation device. Obviously, that's easier during construction - not so much after the fact.
@danielcriger92343 жыл бұрын
@@oldprankster7606 I see test kits for existing buildings. I am planning on starting a build soon and am trying to address as much as I can on the front side.
@LogixBrands3 жыл бұрын
There's some good information here on the test results comparing the Radon-retarding properties of Halo’s Subterra Plus versus the current code requirements: buildwithhalo.com/product-performance-series/controlling-radon-with-halo-subterra-and-subterra-plus/
@james.telfer3 жыл бұрын
Those backpack guys must be popular with the ladies 😄
@VernBigDaddy3 жыл бұрын
Makes me think of Schluter Ditra. Does the slab insulation provide and isolation of uncoupling benefits? Very interesting stuff sir. I can’t even imagine what a 2 stage pour that size costs. What was the total concrete usage for both pours?
@andrewzzack923 жыл бұрын
Great content as always, and I dig those boots matt, what are they Chippewa? Redwing?
@TheJeffshek3 жыл бұрын
Thoughts on insulating a slab this way or the way you did your remodel/new build personal home?
@HighTimesTrader3 жыл бұрын
Masterpiece
@rodaliste3 жыл бұрын
I see you are passing all of that PEX tubing inside the slab. How would you handle any leaks or replacements?
@eh_bailey3 жыл бұрын
Jackhammer?
@DriverDude1003 жыл бұрын
@@eh_bailey Imagine the face on the repairing plumber when he realizes there are TWO slabs to go through to get to the PEX.
@Eric9987653 жыл бұрын
What do you guys do with the boards left over from the concrete forms? Even pre-pandemic prices I'm assuming you wouldn't just throw it all away. A perimeter fence maybe?
@Thoracius3 жыл бұрын
In the olden days they went into house framing, e.g. roof deck. Just don't want to have to cut that concrete-impregnated board, as it'll wear out blades. Today who knows. Maybe they're reusable?
@joeychitwood60043 жыл бұрын
Yup, I'll be the one... wireless vibrator YEE YEE!
@peterbeyer57553 жыл бұрын
Termite army will get in regardless! Trap them outside by continually patrolling your traps and exterior perimeters.
@jeffsmith21443 жыл бұрын
Get an Aardvark to patrol the perimeter 🤣🤣
@pcatful2 жыл бұрын
Yeah, rebar in the CENTER. I see YT contractors showing it on the bottom. Others saying it's in tension there.... I don't think so. You'll demo slabs where the rebar is under the slab, doing nothing. Topping slab also facilitates radiant heating. Heavy reinforcement for the topping slab. I've seen it with no rebar.
@replyhere5902 жыл бұрын
Hi, Matt or anyone who will comment: If we use 5000# concrete (with cylinders, trust but verify) with fiber for our on grade slab (our all above ground 1st floor will my "basement"; size likely approaching 3000 sq ft), do we still need rebar? FYI, central VA, fairly level area for the build. Money must not be an object, with what looks like a very involved multi-step process there on this one.
@shenoyglobal Жыл бұрын
do we need insulation in places like florida before pouring concrete?
@Jookyforever3 жыл бұрын
Those hold-downs and interrupted trimmers and jambs look super confusing. I assume there is some structure happening on the other side of that OSB?
@RBodge12343 жыл бұрын
I just was watching this 9/4/2021 and I saw the same thing. Maybe there are intersecting wall panels or posts that align with them on the backside of that sheathing and they used longer screws to make up for the reduced penetration depth due to the sheeting thickness? If not, they are possibly oriented in the wrong direction. Usually, hold downs of that size will be attached directly to solid sawn 4x & 6x members or built up stud groupings that are fastened together along the length of the studs so that the group act like a single solid post. Not having spent any time trying to analyze the homes configuration, I just don't know. But, it looked odd to me as well at first glance. I'm sure if it is incorrect, that when the building inspector does his/her framing inspection before giving the OK to cover and insulate that they will get it straightened out. Right?
@sc13383 жыл бұрын
I smile every time he says vibrator lol
@g_force38573 жыл бұрын
Ends up being bomb proof… 😀😀
@buildshow3 жыл бұрын
The term is “Bomber “. But essentially it’s the same thing
@g_force38573 жыл бұрын
@@buildshow not necessarily…
@antonioelizondo31803 жыл бұрын
What are you using for cement forms when you pour foundations on traditional foundations with no basement?
@niklasxl3 жыл бұрын
damn, i thought all slabs where insulated :D though im from a colder climate :D and the load bearing lower layer being pretensioned hollow core slabs bonded together
@bahopik3 жыл бұрын
I'm from Minnesota, and I seen plenty of slabs poured without insulation.
@niklasxl3 жыл бұрын
@@bahopik interesting, might then just be more about what the building culture is where you are building more so then what the climate is when choosing how to build
@randyanderson1983 Жыл бұрын
You don’t want it in the middle you want it 1/3 from the bottom concrete is rigid enough it just needs to not fall
@ELIRAXPRT3 жыл бұрын
pouring two slabs one on top of the other- these people got money to burn
@larrym.johnson92193 жыл бұрын
Matt I am a fan of IFC could you use the termite mesh with the IFC, because termites go up the insulation on the outside of the concrete to the roof? I'm also looking into rammed Earth construction could you use rammed Earth on that kind of foundation or would it have to be beefier?
@DrivingWithJake3 жыл бұрын
On build show!
@Firestorm6373 жыл бұрын
Need solar panels with battery storage. I own a couple EV’s. Nice to have battery back up with power outages. Save $500/month on gas and home electricity.
@chaseweeks27083 жыл бұрын
Kind of curious why you opted to put a ton of those Termimesh's where the pipes are coming out of the slab, rather than just where the pipes are entering the slab. I wouldn't think it would be necessary on pipes that both enter and exit the slab inside the envelope.
@billmoretz8718 Жыл бұрын
Seems like too much work. Termites are soft body insects and here we use Duametacious Earth(spelling). It has rough edges that cut into their bodies. Since they need to get back to moisture insides block walls or under bottom plate works well.
@mgoren90872 жыл бұрын
Matt, could a substrait insulation be applied on a 6 inch slab on grade after the fact and then use perhaps a sub flooring material finished with tile or stone?
@townsendliving97502 жыл бұрын
Pretty sure he's got a video where he's done it, his personal house might actually be an example you're looking for.
@ab_ab_c3 жыл бұрын
Halo slab withstands up to 25 psi = 3600 lbs/sf. Since concrete weights ~145 lbs/ft³ a 4" thick slab would weigh ~48.3 lbs/sf (i.e. 4/12*1*1*145lbs = 48.6 lbs) & a 5" slab would weigh ~60.4 lbs/sf---which is ~1/60 of the rated pressure capacity of the foam insulation. Just think of the damage that would occur if all of the framed walls dropped 1/2" over time. Maybe wall resting floating ceilings are a good idea in such a build...
@jpbinva99193 жыл бұрын
Why would partition walls cause the slab to drop? Remember, the footprint (ignoring the rebar mat) is around a foot wide (assuming the loading travels through the concrete at a 45 degree angle). I would not expect any appreciable settling.
@ab_ab_c3 жыл бұрын
@@jpbinva9919 The drop may be caused by the aging of the foam over many years & because of all of the weight pressing down on it. Suppose the ceiling is fixed to the truss rafters, if the slab & walls drop, then there will be a gap at the top of the walls.
@eh_bailey3 жыл бұрын
Concrete SIP!
@buildshow3 жыл бұрын
Totally
@retiredperson40542 жыл бұрын
What thickness and R value would be the best for a two car garage where the concrete would be 4 inch thick and the floor heated with PEX Tubing?
@fshjdkfhasdkfhsd3 жыл бұрын
So you only trust under slab insulation in a split slab sandwich, not on gravel or ground?
@rootvalue3 жыл бұрын
The music and sensational editing style are very distracting. The information kicks ass though and I always learn something from you. Thx for sharing.