can we do this same test on nylon? also let me know how to find out the IV. value after running this experiment. I.V value would be on the screen or need to calculate from equation? please let me know Thanks
@biswajitsaha1174
@biswajitsaha1174 5 жыл бұрын
How to test discoloration of Pet Flakes?
@AliKlcTEMAG
@AliKlcTEMAG 5 жыл бұрын
Color b test
@ifunanyaeze8685
@ifunanyaeze8685 2 жыл бұрын
good evening, Please note we are facing some IV variation on pet pellets. We took sample from cooler, that IV was 0.823, then after we took same sample from bag and kept in oven with 160 degree for 4 h and recheck its IV , which came 0.724. how is it possible?
@HangzhouZonwonTechnologyColtd
@HangzhouZonwonTechnologyColtd 2 жыл бұрын
hi , this is Kent, we are the viscometer manufacturer, and I am very interested in your trouble. kindly share why put the PET in the oven at 160 degree? if the sample is suspected moisture content. then put the oven 105 degree, 2 hours.
@tiwianggraini4707
@tiwianggraini4707 2 жыл бұрын
@@HangzhouZonwonTechnologyColtd Hi, should we use vacuum oven or only drying oven? I also want to know if it's possible to use resin that has been tested using moisture analyzer to tested using MFI tester? Thanks before
@AliKlcTEMAG
@AliKlcTEMAG 5 жыл бұрын
This is not IV measurement, but MFR... IV is completely different.
@johnbiagioni
@johnbiagioni 3 жыл бұрын
The LMI contains a formula that determines IV from MFR
@ngohieu9839
@ngohieu9839 3 жыл бұрын
@@johnbiagioni just for PET
@HangzhouZonwonTechnologyColtd
@HangzhouZonwonTechnologyColtd 2 жыл бұрын
@@johnbiagioni Melt-Flow Index - Not always reliable MFI calibrated by IV Only reliable for pure polymers cannot be used for important Polymers e.g.PA (humidity) no direct correlation with molecular mass sensitive to any additives, fillers etc. good for production control
@johnbiagioni
@johnbiagioni 2 жыл бұрын
I would disagree and know people that have correlated rPet IV between solution viscosity and a LMI/plastometer. If a LMI can correlate to the laboratory standard of solution viscosity results for recycled materials then I’d say it’s good enough for industry.
@johnbiagioni
@johnbiagioni 2 жыл бұрын
And additional materials could be correlated if you took the time to characterize the materials between a LMI, LCR and solution viscosity. It comes down to accuracy, what’s “good enough” and what time you want to invest in your process.
@delenor5682
@delenor5682 12 жыл бұрын
recycling auf höchstem niveau
@davemiller401
@davemiller401 3 жыл бұрын
Perhaps the most boring video I've ever seen. Unless I am watching a beautiful woman posing, I need some sound. 😀
Indorama Ventures: PET Production (EN Version)
4:55
Indorama Ventures
Рет қаралды 31 М.
Intrinsic Viscosity and Mark Houwink Equation
6:07
StudySession
Рет қаралды 12 М.
UFC 287 : Перейра VS Адесанья 2
6:02
Setanta Sports UFC
Рет қаралды 486 М.
GIANT Gummy Worm #shorts
0:42
Mr DegrEE
Рет қаралды 152 МЛН
OCCUPIED #shortssprintbrasil
0:37
Natan por Aí
Рет қаралды 131 МЛН
What is mathematical thinking actually like?
9:44
Benjamin Keep, PhD, JD
Рет қаралды 30 М.
Intro to Polymers: Polyethylene Terephthalate
6:49
Acce-Sci-ble
Рет қаралды 20 М.
Color Measurement  | Starlinger viscotec
4:00
Starlinger viscotec Viscotec
Рет қаралды 1,7 М.
Roast Test PET | Starlinger viscotec
3:10
Starlinger viscotec Viscotec
Рет қаралды 1,9 М.
Viscosity determination with animation.
2:16
Ravindra Zoman
Рет қаралды 179 М.
Polymerization Process -3D Animation / Polymerisationsprozess
3:34
UFC 287 : Перейра VS Адесанья 2
6:02
Setanta Sports UFC
Рет қаралды 486 М.