My undergrad professor just made us memorize that chemistry equation without much explanation. This is amazing, thank you!
@TylerLey5 жыл бұрын
I am glad it helped!
@menwithflaws2 жыл бұрын
Ohh God Why are you so Underrated ???
@goofygoober6229 ай бұрын
thanks my guy, concrete maniac!
@JR-kk6ce Жыл бұрын
So, based on what you said, most concrete restoration today, where they jackhammer out the spalled area, clean the rebar, and patch the area with new concrete, will only make things worse due to the difference in ph between the old concrete and the new concrete in the patch?
@JasonGordon74 жыл бұрын
Thank you! Very helpful
@Effonefiddygarage3 жыл бұрын
@tyler ley About the Seaside FL condo. I'm not sure why the city and county ignored the 2018 report of Spalling on the pillars.
@user-hk7dw3dh4j4 жыл бұрын
Can you do a video on how to repair reinforced concrete that is showing these signs? I really need some info. I have been trying to keep it dry. But, I'm in Portland Oregon. 16 story building, top floor is reinforced concrete. It has two massive exhaust fans, and a really expensive cooling tower. The floor is already showing signs of failing, 60+year old building. My boss doesn't seem to care. I think the worse case scenario. IDK what to do. Any help would be great. Thank you for your time and efforts in making this channel, and the videos.
@mohamedthasneem73275 жыл бұрын
Thank you sir 👌👍
@eddiehernandez7119 Жыл бұрын
I think you forgot to mention that if dissimilar metals are both encased in the concrete such as galvanized steel (zinc coating) connected to the rebar either by directly touching it or maybe it is electrically shorted to it, the zinc will become an anode relative to the rebar cathode. This causes the pH around the anode to go down and thus corrodes. You can see this by spraying phenolphthalein onto the roughened concrete surface or broken cross sections. In building slabs, if you test an area experiencing rust and the concrete pH is too low for the phenolphthalein to turn pink and then you test an area 12 inches away with no metal in it and it turns pink, the metal with low pH encasing it is likely electrically continuous to a more noble metal.
@erfanomar20402 жыл бұрын
hello Dr. with which FEM program will can simulate corrosion in RC structure please thank you
@christophergraham945 жыл бұрын
Outstanding!
@of-lg5bj4 жыл бұрын
Hi Tyler, I have a question and seek your opinion please. I poured a house slab two years ago and it has been exposed to weather.ie had to place project on hold. The house slab is 25mpa and not 20 mpa, well placed, no cracking but only has 20mm cover. although I am about to start building I am concerned about possible corrosion. without taking a core, do you think I am overly concerned or could it be a issue?. slab is away from coast and no chloride s or sulphates present. thanks
@keithpeacock92823 жыл бұрын
How about use STAINLESS STEEL REBAR!
@onlyforarmy21233 жыл бұрын
All the best for your Concrete movie 🎥🍿
@MuhammadAli-cl9qo6 жыл бұрын
Really impressed
@TylerLey6 жыл бұрын
Thank you!
@alihamiad78496 жыл бұрын
Thanks for your explanation. Dr. Ley how do you determine chloride ions in concrete?
@TylerLey6 жыл бұрын
I talk about this in the diffusion video. You can see it here: kzbin.info/www/bejne/jIWUm2hrp52Snsk
@lestersmith77483 жыл бұрын
This video might be getting a lot more views soon. #surfside
@lumo94355 жыл бұрын
wow you are sooooo goood at explaining :)
@TylerLey5 жыл бұрын
Thank you so much!
@patkonelectric6 жыл бұрын
So in future videos, do you think we should be testing the PH in concrete. I already do it in my garden and pool.
@TylerLey6 жыл бұрын
I am going to talk about this soon in a video. We do test the pH for carbonation. It is easy and pretty cool.
@rajeshkumarsharma57545 жыл бұрын
The volume of Fe2O3 is less than that of Fe(OH)2. Source: Mehta and Monterio,2006.
@siamakmohmedi-kartalaee42274 жыл бұрын
Corrosiong in Concrete sewers: Crucial research helps keep sewer corrosion at bay Concrete is the most commonly used material in sewers, especially for large sewer pipes, which can be attributed to its strength, durability and relatively low maintenance costs. Read More: www.gcoportal.com/corrosiong-in-concrete-sewers-crucial-research-helps-keep-sewer-corrosion-at-bay/
@32353235e6 жыл бұрын
Or you can simply use fibreglass or basalt fibre rebar 😎
@mam007ad Жыл бұрын
The explanations in two videos are contradictory! In this video, it stated that Iron Hydroxide is referred to as black rust, while in another video (kzbin.info/www/bejne/eKLTfXejlK6hh8k), it mentioned that Iron Hydroxide is present in the passive layer. would you please clarify it?
@GURMOHINDERJITSINGH3 жыл бұрын
can we get its written literature, because the way of your explanation is appreciable. PLEASE I am in urgent need of that
@constructionhacks81623 жыл бұрын
Hello thiqs is the link to my thesis dissretation about chloride induced corrosion in concrete : kzbin.info/www/bejne/mGLdeGaratyde6c
@hunter24424 ай бұрын
Oh shit, I used acid to unclog my bathtub , maybe the plastic pipe cracked and it seeped into my concrete floor and into the beam.