No video

Introduction to FlowJo v10 March 2022

  Рет қаралды 31,416

FlowJo Media

FlowJo Media

Күн бұрын

Пікірлер: 12
@sou2910
@sou2910 2 күн бұрын
Thank you for this! Very helpful!
@lantianlu9959
@lantianlu9959 8 ай бұрын
A whole lot of useful info. Thanks!
@safimoshkani8495
@safimoshkani8495 Ай бұрын
Thank you❤❤
@digups3673
@digups3673 Жыл бұрын
Thank you so much, very useful.
@FlowJoMedia
@FlowJoMedia Жыл бұрын
Glad it was helpful!
@vincentwitness4432
@vincentwitness4432 Ай бұрын
This is nice and very informative. is there anyway where i can download flowjo to use for my studies
@carolinen.9284
@carolinen.9284 7 ай бұрын
Thank you for your tuto. I have a question about your FMOs used to determine the positive gates for IFN, Perf etc. Have they been done with isotype antibodies? Thank you
@FlowJoMedia
@FlowJoMedia 7 ай бұрын
Hi user, No. Those Fluorescent Minus One (FMO) controls do not contain any isotype antibodies. Those FMOs contain all of the stains used in the experiment except for the stain referenced in the FMO, ie the IFN FMO has all of the stains except for the IFN stain. We hope this helps!
@echnaton4989
@echnaton4989 11 ай бұрын
Amazing Tutorial, Thank you so much! I have a question about performance of FlowJo. I got Problems when applying gates to other samples. My FlowJo crashes or goes in a state of infinite loading time. I already set the memory use to 1/4of my RAM. Any suggestions? thanks again! :)
@FlowJoMedia
@FlowJoMedia 9 ай бұрын
Hi user, The performance may be boosted if the performance preferences are edited. These preferences can be found under the heart shaped icon and then choosing “Performance”. For Windows users the “Max Sample Cache Size” may be lower than optimal. If many gigabytes of data are being loaded into the workspace a higher sample cache size may be more optimal. Here are some suggested sample cache sizes: For 8 GB of RAM ~2000 For 16 GB of RAM ~8000 For 32 GB of RAM ~16000 For 64 GB of RAM ~32000 Issues can occur when the .wsp or .fcs files being used in the workspace are stored on a server. This is because the computer can often have poor or inconsistent connection to files stored in remote locations. If the files are stored on a server, I would try moving them locally (ie to the desktop) and see if that helps. Below is a link to more information on using FlowJo with a remote drive. docs.flowjo.com/flowjo/advanced-features/remote-data/
@JenniferGrinder
@JenniferGrinder Жыл бұрын
X axis has no "Time" option for my graphs, is this a preference I can select somewhere? Using Flowjo V10.8
@FlowJoMedia
@FlowJoMedia Жыл бұрын
Hi Jennifer, Some Cytometers do not display record a time parameter. FlowJo does have a Event Number parameter that can function similar to time, displaying the sequence the events were recorded into the file by the Cytometer. This can be found under the preference “Heart icon” in the “Graphs” section. Hope this helps!
11.3.22 Intro to FlowJo
1:39:14
FlowJo Media
Рет қаралды 7 М.
Flow Cytometry Introduction - Malte Paulsen (EMBL)
33:55
iBiology Techniques
Рет қаралды 116 М.
لااا! هذه البرتقالة مزعجة جدًا #قصير
00:15
One More Arabic
Рет қаралды 51 МЛН
Look at two different videos 😁 @karina-kola
00:11
Andrey Grechka
Рет қаралды 14 МЛН
WORLD'S SHORTEST WOMAN
00:58
Stokes Twins
Рет қаралды 193 МЛН
Zombie Boy Saved My Life 💚
00:29
Alan Chikin Chow
Рет қаралды 8 МЛН
High Dimensional Data Analysis in FlowJo™ v10
1:03:47
FlowJo Media
Рет қаралды 6 М.
Internet is going wild over this problem
9:12
MindYourDecisions
Рет қаралды 69 М.
Flow Cytometry & FACS  |  Beginner Data Interpretation Tutorial
8:42
Flow cytometry - Compensation of spectral overlap [WEBINAR]
38:58
Miltenyi Biotec
Рет қаралды 57 М.
OpenFlow: Introduction to Flow Cytometric Data Analysis Part I
1:33:26
OpenFlow Cytometry
Рет қаралды 38 М.
FlowJo [BASICS]
10:40
Aja Rieger
Рет қаралды 31 М.
لااا! هذه البرتقالة مزعجة جدًا #قصير
00:15
One More Arabic
Рет қаралды 51 МЛН