Kuch seekhne kk hi mila koi bhi uljh skta h bhai koi bdi vat nhi shukriya seekhabe ke liye thank u 😊
@ShrikantKubde2 жыл бұрын
Bhai colour ke hissab se kabhi mat chalo phase ki countinuity chalo.... Kabhi kabhi koi motor woner motor ke cable joint colour wise nahi karata isiliye pahale check karana zaruri hota hai....
@indrakumarVerma-y9r6 ай бұрын
वेरी गुड सर बहुत अच्छी शिक्षा देते हो
@rakeshlifevillagevlogs5738 Жыл бұрын
Pahle se chalne ke liye vah star mein chalega to bad mein vah dalta mein pad jaega a wall starter nahin hai to isliye aur digital mein timer hoga to hamara password problem aaya tha isliye a jao Bata rahe ho sar bahut knowledge phool hai sar achcha Laga jo aap koi technician ke pass share kar rahe ho bahut achcha Laga
@Rajpal_banna482 жыл бұрын
Aap guru ho sikhane ke liye
@kamajisonatakke-ir3tuАй бұрын
Sir, upper ki starter connection sahi hai, niche wali starter me apne pahale pilla,nilla.lal lagaya hai,balki pahale lal,pilla,nilla honar chahiye,galat ho Gaya to maf kar dena.
@sushantchhatar95988 ай бұрын
Pehla video dekha or subscribe bhai KIA,
@jayaprakaskdk Жыл бұрын
🕺Super ,, i am big fallower , i am also repair all type motor winding ,, i know startar repaire ,, next next video ko shuru startar details , and problem solution and how check
@AdvantageTechnologyChannel Жыл бұрын
Sure 👍
@vitthallingayat541 Жыл бұрын
Bahot badiya guruji ye sahi bat hai ❤ very good
@manojrawal757 Жыл бұрын
Mu1 डेल्टा ब्लॉक में कनेक्शन करना चाहिए जो आपने किया है वह सही है
@navinpatel3052 Жыл бұрын
Really good information sir.
@dadaravyadav1225Ай бұрын
Thank you sir good information.
@prafulchavhan9411 Жыл бұрын
Super information sir
@chhotupatil2298 Жыл бұрын
धन्यवाद आतील भाई
@karamjeetselwal50502 ай бұрын
Good 👍 information
@balrajgurol74093 ай бұрын
Excellent knowledge
@omprakashdhurve15042 жыл бұрын
Teh Dil dhaneywad sirji etni achhi jaankari dene k liye 😍🙏
@Mr.KingNilesh10 ай бұрын
Sir Aaj kal volt ki bahot problem hai Aaj kal volt 400 btata hai lekin usme jitna karent hona chahiye utna nhi hota hai to motor ko kis tarah se bnaye Ki vo Pani theek se dene lage sir please Eska koi solution btaye Kyo ki Aaj kal yhi ho rha hai jisse kisan Bhai bhot presan hai please ❤
@rupeshnaik90562 жыл бұрын
Thanku so much Akhilbhai..🙏
@rkmusicvlogs67292 жыл бұрын
A1-b2 B1-c2 C1-a2 ke sath hoga Aap ko continute check kar ke pata karna chai tha
@BhimSingh-co3ti7 ай бұрын
Very simple connection hai
@HackerHacker-ir3qt Жыл бұрын
Thanks bro ❤❤
@शेतकरीराजा-म1छ2 жыл бұрын
खुप भारी माहीती सर
@satyendrapatel626222 жыл бұрын
Nhi pta thha apka dhanyawad
@sohial08712 жыл бұрын
Nice bhau 👍
@zakirmulla1364 Жыл бұрын
Thanks for shearing good info
@subhashpadvi3657 Жыл бұрын
Nice video Sir
@KULDEEPSINGH-mh3fn Жыл бұрын
Bhai in to wignig contion ki vidio bnao
@bhaveshchavda10412 жыл бұрын
Very good ye chhoti chhoti chije hi technician ko bahot kuchh sikhati hai.
@Painkiller1912 жыл бұрын
bhai saab kisi bhi side per jao hmesha 0 se start karna ratan vidiya nhi lgani ye ratan vidhya lgane ka kam costmer karta h mistri hokar bhi apne sath ye situations to honi nhi chahiye mistri bhi aker ratta lagaye to kuch matlab nhi h apne 10saalo me jhak hi mrayi h admi perfect tab tak rhega jab tak wo kaam karta rhega kisi bhi side per jao starter connection pure chek kro thank you bhai saab mujhe bhi experience milta h kis jagah dhayan jyada dena chiye
@subhashpadvi3657 Жыл бұрын
Bhahut danger process he Sir
@kanhaiyagurjar113110 ай бұрын
ML2 F stater main bhi yahi hai Drawing dhekh kro star contractor main achhe se connection dekho chek kro No colour coding Find only eng. Think ok bhai jo bhi problem aaya seyar kiya thanks
@bijay91332 жыл бұрын
Bro ,🙂 first check the all internal connection of panel with multimeter without three phase supply Then check through LLY weather it is star delta or other then ensure all the cables and leveled yourself to not get confuse on it .first run one pump then again second ,and third ok And also check control wire of star delta then it will work properly man
@kishorsahu813 Жыл бұрын
Bilkul right bro ......ye chalu chhap electrician h
@AmitKumar-fj7vv Жыл бұрын
Appney dono coil ka connection karanay say pahalay 3 wier direct phale jood kay aur 3 wier ko kulay rahaney daytay aur multimiter kay satt 440v ak, ak kar wier jodatay to appko dikat nhi hogi
@mukeshnayak-gn6dr Жыл бұрын
Very good 👍
@rajvardhanpatil98992 жыл бұрын
मार्किंग ना होना और शुरुआत से आपका का उस कनेक्शन में हाथ ना होना यही मूल वजह है जो की ग्राहक को समझना मुश्किल होता है
@nabishaikh25232 жыл бұрын
Star delata stater par video bnai
@Mr.SantoshPatil-rg4ru11 ай бұрын
Sir एसी विषय पर ओर व्हिडिओ बनाव ओर फुल्ल डिटेल व्हिडिओ बाणाये मोटर के कनेक्शन भी दिखाये
@hirenjaviya94672 жыл бұрын
Apne main contecter or star contecter me connection kiyatha ye galat hai. Main contecter or delta contecter me connection joint karna hota hai. Apne cabal connection galat kiya tha. Sahi conection-RYB /BRY hota hai. Ape ache mecanic ho. Khai bar galti ho ja thi hai
@vinodkhadake389 Жыл бұрын
Main or star mein karte hai bhai,delata maein Kiya to starter or motar jal jayegi
@nandkumarsurve4 ай бұрын
Very y nice
@rakeshlifevillagevlogs5738 Жыл бұрын
Thankyou sir
@sukhlalsoren870519 күн бұрын
Connection sahi hai
@sureshbishnoi4033 Жыл бұрын
O ho 😊❤
@rajneshkushwaha4168 Жыл бұрын
Love you Bhai
@kishorsahu813 Жыл бұрын
Electrician bhai aap to tukka lga rhe ho aisa nhi hota ...agar aapko ek hi color ka teeno wire de diya jay tb aap kya kroge ...bina multimeter ka aap star delt connection n kre
@aaa-vc8sk2 жыл бұрын
Bhai konsi company ka starter best hota hai iski ek video banaoo please
@goutamkumarsharma25142 жыл бұрын
Sar ji hame problam pata nahi tha thanks sarji video banane ke liye
@ShoukatAlisattiSatti-yh8lm Жыл бұрын
Nice 👍👍👌👍
@jagdishmachhirke41122 жыл бұрын
Sir mujhe single phase our three phase motor ki wainding ki swg turn pitch our coil grup nikalne ka formula chahiye please batao
@RameshPatel-wd5jy Жыл бұрын
Sir 6mm cable me single cable se Delta connection kr ke 10 hp moter chala skte h kya....mere gav me water lable 500 h to double cable se kharcha bhut aa rha h
@mrmorlivala2065Ай бұрын
yas bhai
@mrmorlivala2065Ай бұрын
o sal sakti he
@rakeshlifevillagevlogs5738 Жыл бұрын
Sir apne 3 starter main line jordiya sir 2 starter me hoga sir
@GulabbhaiChaurya11 ай бұрын
Star Delta starter me m power kaise lagta hai vidio bhejona sr
@doleshwarmahant7740 Жыл бұрын
Jb v star Delta stater hota hai usme motor ki wire hmesha main contractor aur Delta contractor me lgta hai. Aur rahi baat r, y, b ka to multimeter se continuity check kijiye, aur aisa connection kijiye ryb ka ki continuity n aye motor turnt chlegi.
@hareshbhaibheda2314 Жыл бұрын
Bhai dayagram padhana sikha dijiye
@ghanshyamjalera33362 жыл бұрын
સરસ જાનકારી
@fareedkhan-jr1hf Жыл бұрын
Sir aap multimeter se power ki wiring check kar sakte the Tab aapko motor ki wire connect karna chahie
@ShivajiJawle-gf2cj Жыл бұрын
Very nice
@omprakashlohar53992 жыл бұрын
Last mai jo connection diya O sahi hai avhi niche Sam connection kro kuch nhi hoga( R Y B )(B R Y)
@rakeshlifevillagevlogs5738 Жыл бұрын
Sar yah digital starter timer hai to timer ka taraf to star mein chalta hai to 2 second baap 5 second part aur delta mein pad isliye sar niche lagana
@ferozpatel77322 жыл бұрын
Good explain sir
@pavanamliyar18962 жыл бұрын
Sar ji humko is per delta wala starter Ghar per banane ka tarika batao
@harishmagar90472 жыл бұрын
supar.ansar.sir
@mubinshaikh73592 жыл бұрын
Sar niche ka starter short Hota Hai Shuru Mein motor star per Chalti Hai bad Mein Delta Ho Jaati Hai
@mubinshaikhshaikhpatel91192 жыл бұрын
Mera confusion aapane Dur kar diya thank u
@sureshbishnoi4033 Жыл бұрын
बाद मे मोटर डेल्टा में ही चलेगी 😂😂😂
@jitendrakumarrana976810 ай бұрын
Motor connection karne se pahle starter ka internal circuit check kiya jata hai starter ek bar on karke check kiya jata he uske baad motor connection kaijata he
@BillyBangera8 ай бұрын
BCH k started main delta stater mai he hota hai with out multimeter kaam krne ka tarika casual hai
@aksingh05223 ай бұрын
घंटा सिंह नीचे वाला स्टार contactor है, शॉर्ट है।
@Dekhjara3 ай бұрын
Sir मेरे पास ऐसा ही star delta का 20hp का stater है उसमे auto master cantroler भी है जो खराब हो गया है अब मोटर को खुद चलानी होती है ( एक stop का बटन ओर ग्रीन का बटन है green बटन दबाकर चलाते हैं ) मेरा सवाल ये है कि क्या खराब मास्टर कंट्रोलर को हटा दु तो मोटर चलेगी ना या नही चलेगी।
@AdvantageTechnologyChannel3 ай бұрын
Mere ko nahi pata master ke bare me
@Dekhjara3 ай бұрын
@@AdvantageTechnologyChannel नही पता ये क्या जबाब हुआ sir आप इस इस प्रकार के video बनाते हो star delta आदी के बारे मै और आप कहते हो नही पता। आज से आपके वीडियो देखना बंद झुठा ही टाईम खराब किया आपके channel पर
@devrajlodhiblog74902 жыл бұрын
Hallo 3face moter yadi 2face se chalay to koi nuksan hia ki nahi (pani me kiya anter aayga)
@maneeshvishwakarma95672 жыл бұрын
हां एक तो आप उसको
@maneeshvishwakarma95672 жыл бұрын
एक तो आप उसकोएक तो आप उसको स्टार्ट करने के लिए कैपेसिटी या रिले लगाते हैं तो चालू तो हो जाएगा लेकिन लोड नहीं लेगा
@maneeshvishwakarma95672 жыл бұрын
और मोटा जल्दी सकता है
@maneeshvishwakarma95672 жыл бұрын
सॉरी लिखने में गलती हो गया मोटर डबल फेस में जल सकता है
@hansrajkhatri9835 Жыл бұрын
जो केवल वाइंडर होता है उसे स्टार्टर के बारिकियों के बारे में जानकारी कम होती है
@mrmorlivala2065Ай бұрын
me ana malti mitar ka upiyog karke hi kanesan karta hu
@bhavinhalpati65192 жыл бұрын
R ke samne R Y ke samne Y B ke samne B Ek coil ko 415v milna chahiye
@sayedyaqub61242 жыл бұрын
Sar istar connector me cibal lagasakte hi
@mdsazzad53742 жыл бұрын
Aap ko startor mea a1,b1,C1 phase A2,b2,C2 phase voltage chake kar connection karna chayea tha
@rahulsutar5420 Жыл бұрын
Ok sir thanks
@devidasmore776 Жыл бұрын
हा भाई मुझे पता है एस्का कनेशन .....
@manojrawal757 Жыл бұрын
भाई साहब आपको डेल्टा ब्लॉक में जोड़ना चाहिए वही कनेक्शन जो आपने किया वह
@maheshgeddam1937 Жыл бұрын
Another set of no nc in different place how to connect please tell me bro
@PandharpurDarshan50 Жыл бұрын
डेल्टा से स्टार के ब्लॉक को आये वायर R B एक बार ही चेंज करे तो यह प्रॉब्लेम हमेशा के लिये मिट जाता है. रेग्युलर स्टार्टक की तरह मोटर की ६ वायर जोडना है
@S.R.b451 Жыл бұрын
Sir star delta motar singhal cebal par cepesiter kese lagaye
@chandravadiyaashik86552 жыл бұрын
Single pase ki .motar kitane ki motar kitane amp lete he ye bataye video banaye
@ganeshchalkalwar95562 жыл бұрын
Singal phase 1hp=6amp
@ganeshchalkalwar95562 жыл бұрын
Singal phase 1hp=6 ampiar
@sureshbishnoi4033 Жыл бұрын
30 कि मोटर 45 amp
@mukeshsahu959 Жыл бұрын
Star contactor mein Laga Diya Tara aapane 442 hoga hi
@prashantgaikwad8277 Жыл бұрын
Sir mere sath aisa hi huva tha
@dipakbhojane5054 Жыл бұрын
अखील भाई तुम बताते बताते बहोत कुछ डायलॉग मारते हो 😂😂मुझे बहुत हसी आ रहि है😂😂😂😀😂
@sahmaanKhan Жыл бұрын
Sir nahi pata tha
@PramodYadav-uu1xh2 жыл бұрын
Startar main connection chenge hoga ho skta hai
@Mani_Neeraj2 жыл бұрын
Bhaiya star delta motor connection aise karega to motor overload hoga hee aap star delta motor connection karane se pahale motor ka terminal check Kijiye. Usake bad stater ko on kar ke output voltage check Kijiye. Or star me or delta me dono me voltages check kar ke tab connection Kijiye tab kabhi nhi stater ka phase short hoga
@justice80082 жыл бұрын
Starter banane walo ne motor cable connection ke liye U1 V1 W1 aur U2 V2 W2 nahi diya hai to ye problem ati hai. Aur star contactor ko jodna waise bilkul galat nahi lekin balki aapko jyoki compani walonehi wire ghumake de di gai hai to apko motor wire ke colour bilkul ghumane nahi hai. Main contactor ko RYB hai to star contactor ko bhi RYB hi lagana hai. Apne khud ka pahalewala jo connection jagah galat nahi thi sirf galati yahi thi ki aapne colour mismatch kiya. U1 ----red wire U2 red wire V1 yellow wire V2 Yellow wire W1 blue wire W2 blue wire Matlab pahela 3 core cable U1V1W1 ko RYB wire agar star contactor pe niche W2 U2 V2 aise pahale se unke connection hi ghumakar diye hote hai. Aise halat me colour ko mat ghumao wire ke colour RYB aur RYB hi lagenge. Local unbranded starter me U1 VI W1 ----------U2 V2 W2 Ya to U1 V1 W1 ---------W2 U2 V2 likha hua nahi hoga isliye apane uska jikra bhi nahi kiya hoga. Please try my suuggestion . Aur ek simple technic mai baata hn jijme kabi bhi fuse nahi udenge . Apko company ki wiring ko sidha ya ghumake dekhneki jarurat nahi hai. 1. Pahale main contactor ko RYB aur star contactor ko bhi RYB( lal pili nili) aisehi jodo. Aise me do chise ho sakti hau . Starter semi automatic hai to on push button jabtak dabake rakhige tab star me chalege our button chodne par delta contactor utheda likin motor ghumna band karegi. Yato bina fuse ude delta me aaram se run hogi. Agar delta me motor ghumna bhand hoti hai to sirf star contacor ki cable wire ko RYB tini wire ko nikal kar Y R B color jodo. 100% kaam ok hog. company wiring ko dekhneki jarurat nahi hai. Aapke us trial mn star me motor chali hogi aur delta me padtehi fuse ude honge. Please give your feedback on my suggestion results on 9673990859
@sujit_rj_maharashtra3632 жыл бұрын
Main or delta me jodna chahiae
@atulvasava19922 жыл бұрын
12 HP ki naya moter he isme RYB,BrY lagaya he firbi moter start nahi ho rahi our fuse Kat yaha he
@hiralalelectrifshoplohar13142 жыл бұрын
Nice👍👏👌 ❤🧡💛💚💜💙
@dindayalsahu-i6e5 ай бұрын
Ha pata hai
@mktechnologyworks2 жыл бұрын
Good sir.🙏🙏
@akshaymali96002 жыл бұрын
Motor 11a current leti hain aur Maine relay setting 10a pe kia hai tab bhi motor achii chal rahi hain tab koi problem aa sakti hain
@manojdas39782 жыл бұрын
1नं सर
@arvind-xe9hc2 жыл бұрын
Hii mujhe pta hai ki kya problam hai kya aap mujhse baat kar sakte ho?
@ganeshchalkalwar95562 жыл бұрын
Akhil Sir AAP cooler code pe mat jana sirt ek simple trick ye hain ke 1phase winding ko440volt Milana chahiye
@electricalwork26595 ай бұрын
Stator wiring check karna chahiye
@AshishKumar-x6u8m Жыл бұрын
Muche sikhana hai
@sahibsingh870210 ай бұрын
aap star delta ander se color se bnao
@Fundose698 ай бұрын
Bhaisaheb colour code se delta nahi milana chahiye starter mai 1 phase already change hoke aata hai kisi mai nahi aata hai best way hai aap series test lamp se delta mila kar connection karo