ITM Dry Valve System

  Рет қаралды 30,912

Northern Illinois Fire Sprinkler Advisory Board

Northern Illinois Fire Sprinkler Advisory Board

Күн бұрын

ITM Information on the inspection, testing and maintenance of a Dry Valve Fire Sprinkler System.

Пікірлер: 12
@alibaba855
@alibaba855 Жыл бұрын
I've watched lots of videos to try and understand how sprinkler systems work. This guy is hands down the clearest and most helpful.
@regionalfpinspections835
@regionalfpinspections835 4 жыл бұрын
accelerator valve should be open! cool video thanks for sharing
@michaeltavares4370
@michaeltavares4370 Жыл бұрын
Hahahah he knows he will pop the valve if he opens it. Those things suck
@ansarishad8830
@ansarishad8830 Жыл бұрын
Can you make the video of double interlock preaction valve trim assembly installation
@TheGardista
@TheGardista 2 жыл бұрын
A strange dry system😳 What are those two valves above dry valves for 😳?
@briancook9579
@briancook9579 Жыл бұрын
That is so you can trip the Valve without flooding the System, you would close those valves above the dry valve then trip the valve. Water would only go to that point. You see this application with pre action systems where they protect very expensive equipment and don’t want to flood the System when they are doing there 3-year full trip test
@ericcorona4466
@ericcorona4466 5 жыл бұрын
Shouldn’t the Dry and the Wet system have to have separate mains ?
@briancook9579
@briancook9579 Жыл бұрын
Usually there is only 1 under ground Main that can feed several systems from a Manifold, Dry or Wet it doesn’t matter
@leam89
@leam89 4 жыл бұрын
Does a building owner have to periodically test the flow switch like on a wet system? How would you do this without tripping the dry system?
@malcolmdown9170
@malcolmdown9170 3 жыл бұрын
The dry side has no flow switch. But it does have a pressure switch which will operate from flowing water from the test drain. This will ring the water motor alarm bell and activate the pressure switch to raise an alarm.
@briancook9579
@briancook9579 Жыл бұрын
Dry Systems use a pressure switch in which you can test on the alarm line trim without tripping the system
@ChuonSophak
@ChuonSophak Жыл бұрын
I don't understand a lot.sir
ITM Wet System Riser, Backflow and Connections
4:08
Northern Illinois Fire Sprinkler Advisory Board
Рет қаралды 32 М.
ITM Double Interlock Preaction System
5:49
Northern Illinois Fire Sprinkler Advisory Board
Рет қаралды 60 М.
He bought this so I can drive too🥹😭 #tiktok #elsarca
00:22
Elsa Arca
Рет қаралды 56 МЛН
GTA 5 vs GTA San Andreas Doctors🥼🚑
00:57
Xzit Thamer
Рет қаралды 31 МЛН
Dry Sprinkler Inspection
2:59
Silco Fire & Security
Рет қаралды 22 М.
ITM Main Drain Test
4:32
Northern Illinois Fire Sprinkler Advisory Board
Рет қаралды 41 М.
Model EX Low Pressure Dry Pipe Valve Reset Procedure
7:19
Reliable Automatic Sprinkler Co., Inc.
Рет қаралды 34 М.
System Reset: Model F Dry Valve - Dry Pipe Fire Sprinkler System
15:05
Viking Sprinkler
Рет қаралды 28 М.
5 year fire sprinkler inspection
20:02
Joy Cool
Рет қаралды 12 М.
Sprinkler System  Nitrogen Generator
4:37
Sprinkler Fitting Canada
Рет қаралды 1,3 М.
System Reset: Viking VXR Dry Pipe Valve
3:20
Viking Sprinkler
Рет қаралды 6 М.
assembly of auxiliary drain for fire protection system
3:10
prosperous tv
Рет қаралды 994
Resetting DPV-1 Dry System Valve
3:37
SprinklerTV
Рет қаралды 1,3 М.
He bought this so I can drive too🥹😭 #tiktok #elsarca
00:22
Elsa Arca
Рет қаралды 56 МЛН