Kitchen Hood Suppression System Maintenance Explainer Video (Argus Fire)

  Рет қаралды 59,445

Screen Grab

Screen Grab

Күн бұрын

Пікірлер: 33
@Digitaltarangs
@Digitaltarangs 10 ай бұрын
Great, Thanks for sharing knowledge...
@agray007
@agray007 Жыл бұрын
what type licensing is required for this type of inspection?
@pressurewashingandhoodcleaning
@pressurewashingandhoodcleaning Жыл бұрын
why do you have all those lights?
@EricPham-gr8pg
@EricPham-gr8pg Жыл бұрын
Thank you for teaching us
@cucinacapresemonaco9932
@cucinacapresemonaco9932 Жыл бұрын
Hallo wean the system get tasted and the gas shot off but not the power what is that mean? thank you for your Time
@bobbishpanicker5725
@bobbishpanicker5725 Ай бұрын
Good
@bluecobalt665
@bluecobalt665 3 ай бұрын
how would u clean allat up
@Julio-o7q
@Julio-o7q 3 ай бұрын
Just do it
@jitinyadav6507
@jitinyadav6507 2 жыл бұрын
I want to know the refilling time period of fire suspension system
@ahmedalhourani4603
@ahmedalhourani4603 10 ай бұрын
how i can flush the system after discharge
@abdulmajeeth3135
@abdulmajeeth3135 Жыл бұрын
Thanks👍🏻
@hemandersingh4502
@hemandersingh4502 Жыл бұрын
Hello sir Which gas cartridge is this and at what temprature the fuseable link breaks ??
@juliobojorquez8706
@juliobojorquez8706 Жыл бұрын
Nitrogen and temp is 450f
@marks7352
@marks7352 Жыл бұрын
Does it cost money for the system to be inspected?
@cindywine4660
@cindywine4660 Жыл бұрын
Yes
@johnn2557
@johnn2557 2 жыл бұрын
He also did not test the water flow connection for proper pressure and check the water valve in in the locked open position.
@davem287
@davem287 Жыл бұрын
He clearly wasn't going to show every detail it's a customer demo not a training video
@fF-jb4gs
@fF-jb4gs Жыл бұрын
Looks like a training facility by the looks of the extremely clean appliances
@patienceiskey8181
@patienceiskey8181 Жыл бұрын
What size is this?
@fF-jb4gs
@fF-jb4gs Жыл бұрын
3 gallon
@mdbb7202
@mdbb7202 2 жыл бұрын
Umm I hope this ain't a training video. The pull station is too high up. It looks like you are using a small pair of channel locks not the right pliers. What kind of break rod is that? And put a test link in instead of cutting the actual detector. You didn't blow out the distribution line with air.
@davem287
@davem287 Жыл бұрын
It's clearly a customer demo, he's talking to the customer end. The pull station location is probably the customers choice which is fine, Authority having jurisdiction I.e. the owner can specify the location. Nothing wrong with not using a test link nor anything wrong using a small pipe grips for the scissor links. Typical snob engineer trying to shoot down another guys work, I've met plenty like you and let me tell you they are the worst offenders when in comes to compliance. So you know some regulations big deal !! These systems aren't rocket science !
@paullistokin9736
@paullistokin9736 Жыл бұрын
Customer's choice? Nowhere in NFPA 17A or IMC, IBC, ICC, or even in the Ansul (the manufacturer) manual will it allow for a location other than 48" from finished floor. Customer can choose where the pull station goes as far as kitchen location as long as the installer and/or AHJ will allow, but never alter in height.
@Carti2official
@Carti2official Жыл бұрын
Customer does not get a choice in the height of the pull station. No more than 48 inches from the ground. NFPA code, Ansul specifications. Done hundreds of finals with AHJ, fire Marshals and Mechanical inspectors. Same code for fire alarm pull stations.
@annmccormick
@annmccormick Жыл бұрын
Judge Judy
@pressurewashingandhoodcleaning
@pressurewashingandhoodcleaning 2 жыл бұрын
manual pull station is to high.
@davem287
@davem287 Жыл бұрын
Customers choice
@Carti2official
@Carti2official Жыл бұрын
@@davem287customer doesn’t get a choice. No more than 48 inches from the ground is the code.
@nazreatweldeyohannes3334
@nazreatweldeyohannes3334 Жыл бұрын
I need new
@sarwarkarim2921
@sarwarkarim2921 2 жыл бұрын
Great to see you sir i want to connect you so please can i have your email address I'm also fire fighting technician
@Carti2official
@Carti2official Жыл бұрын
That system is well beyond the allowed flow points😂😂😂. You’ve said nothing about nozzle coverage or anything. That’s Ansuls overlapping coverage. Do Better
@iGotSoldAgain
@iGotSoldAgain Жыл бұрын
well it's a piranha system. could easily be a 13 tank. each nozzle has 1 flow and could very easily have be enough flows on the cylinder
@iGotSoldAgain
@iGotSoldAgain Жыл бұрын
also, all piranha systems are total flood
ANSUL R 102 R-102 Owner Operator Training to maintain a Restaurant Fire Suppression System
9:41
Fire Protection Products from Johnson Controls
Рет қаралды 143 М.
The Most Efficient and Safest Restaurant Exhaust Hood Degreaser
5:16
MFS Trade School
Рет қаралды 260 М.
VIP ACCESS
00:47
Natan por Aí
Рет қаралды 15 МЛН
How Many Balloons To Make A Store Fly?
00:22
MrBeast
Рет қаралды 190 МЛН
The basics of a kitchen fire suppression system
5:59
Defense Fire Protection Inc.
Рет қаралды 4,9 М.
FireDETEC Fire Suppression System for Commercial Kitchens
4:12
Rotarex Firetec
Рет қаралды 46 М.
Kitchen Exhaust Cleaning   Commercial Vent
3:01
Commercial Vent Cleaning
Рет қаралды 406 М.
Fire Suppression System - Poor Man’s Food Truck
10:01
Poor Man's Food Truck
Рет қаралды 12 М.
Imperial - WET Chemical Fire Suppression System Simulation
3:06
Imperial Fire Engineering Co., Ltd.
Рет қаралды 153 М.
Ansul Instructional Video for freddy
10:05
Michael Bushatz
Рет қаралды 14 М.
Commercial Kitchen Inspections
9:44
Kauai Fire Department
Рет қаралды 2,3 М.
Wired a Commercial Kitchen with Another Professional Electrician
9:50
Peterson Electric
Рет қаралды 41 М.
PRI-SAFETY Kitchen Fire Suppression System Installation Instruction
10:58
Steven Meng (PRI-SAFETY)
Рет қаралды 2,9 М.