sir upload lectures on cantilever and continous beam. i have watched all lectures of rcc. really amazing. nice work. thanks a lot.
@adnanrasheed29208 ай бұрын
Excellent ❤
@thammisettyvenkatrao72667 ай бұрын
Hi , could you please post the video on column design under torsional moment.
@sudarshannikam5243 Жыл бұрын
Thanks Sir. Can we say couple acting on primary beam where the point of resting of secondary beam on primary beam. OR Are those same Couple and Torsion?
@DCBAonline Жыл бұрын
Yes if secondary beam is connected to primary beam integrally, the secondary beams puts a torsion on primary beam at the point of contact.
@sudarshannikam5243 Жыл бұрын
Thanks Sir 🙏🙏
@DBDBSAJHAR2 жыл бұрын
very helpful video
@sathiyascivil19872 жыл бұрын
Very useful video sir.
@collelector59722 жыл бұрын
Thank you Bhai!
@sudarshannikam5243 Жыл бұрын
Sir , Does beam can be designed Doubly Reinforcement at near support (for Hogging Moment) in case of fixed end condition? OR Should we design doubly section only for span moment where sagging moment occurs ?
@DCBAonline Жыл бұрын
The reinforcement in a continuous beam is carried at both top and bottom, but it is given according to the reinforcement designed at the respective sections i.e support or span.
@sudarshannikam5243 Жыл бұрын
Thank Sir. Can we use that under reinforced or over reinforced phenomena for beam occurs - ve moment (Hogging) i.e. fixed beam at end support or cantilever which have reversible forces means Tension at top and compression at bottom? Generally we used this theory for beam section having +ve momemt i.e Comp. at top & Tension at bottom.
@shubhamsaurabh83534 жыл бұрын
very nice lecture
@sanjaybhat46942 жыл бұрын
Hello could you please tell , where or which clause in code book did you find the ast and asc formlue?
@nabinbista42133 жыл бұрын
thank you so much helped a lot to understand
@saurabhvidhate85334 жыл бұрын
Sir from which concept formula for (moment due to torsion =Mt and shear due to torsion ) will come ??
@crisolannarienza90643 жыл бұрын
Good day, sir. How do I calculate or solve for Tu if given is a torsional moment of *kN.m dead load and *kN.m live load? Hoping for a response, sir. Thank you.
@centlytical Жыл бұрын
I know it's late but you need to factor out the live load and dead load using the load combination specified by the code example 1.2D.L +1.6 L.L
@ajitkurey52253 жыл бұрын
Sir your video is so good just tell me how can we calculate Tu for beam is IS code recommended any formula
@DCBAonline3 жыл бұрын
Tu comes from analysis of structure, it is generally due to secondary beams on primary beams.
@abhaytalathi29294 жыл бұрын
👍👍
@pauldaniel39894 жыл бұрын
How to find Xu for designing singly reinforced section
@saurabhvidhate85334 жыл бұрын
Sir when we design a beam for torsion with today's steps then no need to again design for bending and shear separately ??
@DCBAonline4 жыл бұрын
Yes
@saurabhvidhate85334 жыл бұрын
@@DCBAonline how sir we consider shear force and bending moment in torsion design steps so why we need again design
@DCBAonline4 жыл бұрын
You asked no need to design so my answer is yes, we dont have to design
@saurabhvidhate85334 жыл бұрын
@@DCBAonline ok sir
@flyingk24883 жыл бұрын
Please sir make a video on torsion of beam ( numerical)
@DCBAonline3 жыл бұрын
Its already made, check the next lecture to this.
@civilspectrum244 жыл бұрын
Is this channel for competitive exam, sir can i study for gate exam here,
@DCBAonline4 жыл бұрын
Yes for structural subjects
@karneshwetha66302 жыл бұрын
when there is effective cover why to assume it as a clear cover ?
@cadm-benzbuft212 жыл бұрын
under what condition there is no tortion on beam??? does beam have tortional moment if it diesnt have secondary beam in between?
@DCBAonline2 жыл бұрын
Yes why not, will depend on what type of loading is put on beam.
@akshaydev58983 жыл бұрын
Don't we have to convert the moment values to factored values..?🤔
@DCBAonline3 жыл бұрын
If the load considered is factored then no need to factor the moment.
@GomatiGoswami-YearBArchArchite3 жыл бұрын
sir, yeh Es and Fsc wala table kaha se milega IS456:2000 me?
@DCBAonline3 жыл бұрын
IS 456 me nahi hai, koi ache author ke reference book me mil jayega.
@GomatiGoswami-YearBArchArchite3 жыл бұрын
@@DCBAonline sir, el aur doubt tha - Asc = (M_t-M_u)/((0.87fy-0.446fck)(d-d^1)) yeh formula diya hai prof ne class me
@DCBAonline3 жыл бұрын
@@GomatiGoswami-YearBArchArchite unse puch lena kaunse reference book me diya hai.
@GomatiGoswami-YearBArchArchite3 жыл бұрын
@@DCBAonline sir but is456:2000 me toh Asc= Mt-Mu/(fsc)(d-d') - aapke formula me fsc-fcc kaise hua sir?
@tejasbhokare94579 ай бұрын
It's in SP 16 BOOK
@ranjitkaurjaswal4 жыл бұрын
In bt why we took 30 in bt=300-30*2-20*10-16
@DCBAonline4 жыл бұрын
bt = 300 (width) - 30*2 (subtracting clear covers) - 2*10 (subtracting link from both ends) - 16 (subtracting half of bar dia from both ends)
@GomatiGoswami-YearBArchArchite3 жыл бұрын
Sir ismai side face reinforcement calculate nhi kiya