Hi I think stator is constructed from hot rolled steel as cold rolled steel is anisotropic which is suitable more in Transformer
@manoharp68004 жыл бұрын
Sir at 18:32... How the armature reaction reactance decreases increasing of air gap length.. Sir could plz explain...
@randhircheema16424 жыл бұрын
Thank you for prompt reply to my previous doubt. Question: At 04:12, in the figure, even though the direction of current is 'dot' for all four conductors, but the flux direction shown by you is downward!. Would it not be towards the right hand side as per FLH rule? Regards.
@lokesh62294 жыл бұрын
sir, you explained in open type slot magnetizing current requirement is high and leakage reactance is less. but in synchronous generator magnetizing current is supplied by dc so that is already with constant magnitude. little confused sir!
@surugayatri20624 жыл бұрын
Practically wedges are placed on armature slots ..so that winding doesn't come out. Do wedge also offers same permeability to flux path sir??
@deepankarmajumder24044 жыл бұрын
Sir, For open type slots, the voltage drop is less because the leakage reactance(Xl) is less (as the leakage reactance is in series). But in Power System, we learnt, reactive power at receiving end(Qr) is inversely proportional to synchronous reactance (Xs). Now, if leakage reactance(Xl) is less, then synchronous reactance(Xs) is less, then Qr is high. We know, major cause of voltage drop is reactive power. So, as Qr is high, voltage drop will be high. So, the above two conclusions are contradictory
@satyaprakashjindal23114 жыл бұрын
Sir in open slot air gap is more than why leakage flux is less
@yugandharkalimireddy90194 жыл бұрын
I am very thankful to our best lectures Sir,can u please make a video on transistor astable multi vibrator circuit
@yugandharkalimireddy90194 жыл бұрын
@@lecturesinelectricaleng OK sir
@anniejones17785 жыл бұрын
How is it possible to have 3-phase motor with 4-pole winding.
@MATHEMATICSBYNITianHimanshu4 жыл бұрын
Thanks Sir😍😍
@mounikajamalapuram8113 жыл бұрын
Thank you sir
@learninteresting54515 жыл бұрын
Sir mention all point to cover each amd every topic its very useful for us.
@learninteresting54515 жыл бұрын
Sir I preparing for competitive exam for electrical engineering would u help me for the exams
@mounikajamalapuram8113 жыл бұрын
Useful flux kadha sir low ; leakage flux is high sir is this right or wrong ?? Sir
@sabavathrajkumar3234 жыл бұрын
Open slot more commonly used in stator synchronous machines why? Sir.