No video

LG Linear compressor Refrigerator Alternative Replacements. Convert to 115v compressor Refrigerator

  Рет қаралды 15,866

Jorge Martinez

Jorge Martinez

Күн бұрын

Wiring sketch. If there is some questions maybe something You don’t understand drop a comment will be happy to guide you through. Try it. I’ve done hundredths of these and tested it out many before taking them out for sale. Lots of testing and proved to work very efficiently. Also make sure to do a system flush for better results on your Refrigeration work.

Пікірлер: 121
@abcappliancellc3122
@abcappliancellc3122 5 жыл бұрын
Awesome hack Jorge this will save my customers and me a lot of money and make these linear compressor refrigerators way more reliable thanks again
@JorgeMartinez-ql4ov
@JorgeMartinez-ql4ov 5 жыл бұрын
ABC APPLIANCELLC thanks. Will be uploading more videos.
@joseventura3394
@joseventura3394 5 жыл бұрын
Hey George, can you put a picture of the relay if you're not too much problem?
@peet8004
@peet8004 4 жыл бұрын
I finally got it working it seems the wiring on my LG refrigerator was different since it was a late 2019 model the board was completly different. Thanks for sharing this info!!
@gks6022
@gks6022 4 жыл бұрын
So in the schematic he's showing the line input tied to the inverter output...or is he disconnecting the inverter output and using the wires only? The board in his previous video matched mine, but his labels on this schematic don't. (just tryin' to make sure I don't smoke the circus, you know) I disconnected the cap & motor cables, then used the motor cables to tie to the line, and dropped the relay in the compressor compartment...
@peet8004
@peet8004 4 жыл бұрын
GKS yes you are only going to use the wires in my case they were black and blue. You are not going to use the inverter anymore.
@handymanpete
@handymanpete 5 ай бұрын
Good day, can you take a picture of the harness on PCB board, hard to see by the drawing, thanks
@77karimk
@77karimk Жыл бұрын
pretty strait forward , and makes sens , thank you
@serviciosintegradosalhogar7723
@serviciosintegradosalhogar7723 4 жыл бұрын
Excelente ayuda y explicación mi hermano, saludos desde Villahermosa, Tabasco, México. Thank you for your excellent contribution. I send a cordial greeting from Villahermosa Tabasco Mexico.
@matthewmcbryar2814
@matthewmcbryar2814 3 жыл бұрын
What I want to ask is can you just google for 240 vac 12v relay with 5 push on terminal spots. Or do you know the part number for that Ge relay on the motherboard
@commieslayer8218
@commieslayer8218 3 жыл бұрын
Did you come across issue after this conversion with inverter not sensing current draw effecting the function of the fridge? It happened on my friend's fridge so I am looking for solution which may be effecting some other fridges as well. Some may even use thermistors for the processor sense the cooling process working or not. Here is how I found out: While I was testing LG fridge compressor, I disconnected the connector on control board and saw nice voltage incremental rise confirming the board is OK. I tested for PSI while running it and proved no change in PSI confirming compressor failure - 3rd compressor each failed after 2 years. When I disconnected the connector and measured the voltage rise, after about minute or little more the led code blinked 3 times and the system just shut down. I believe that it is the amperage current sensing by microprocessors and when no draw from compressor is sensed, then it turns off. Perhaps some dummy load on the side from the inverter to the compressor which is not connected anymore would help to pretend current draw. This issue with no current draw from the inverter has to be addressed because even if I convert it to standard compressor, apparently it will shut down soon as it did because the inverter is not in use. I hooked up the failed compressor again and the board came to live so it needs some current been taken from the board, at least in my case.
@birdman3931ny
@birdman3931ny 2 жыл бұрын
Yes sir! Though Jorge here made a nice video… it is dated for the kenmore later models. I too am working on my own fridge just did the surgery… but like you said, I think it needs a load on the original compressor wires. Perhaps a resistor?
@commieslayer8218
@commieslayer8218 2 жыл бұрын
@@birdman3931ny Did you already test it and won't keep running because of the aforementioned issue with the load? I assume that the load would have to be calibrated to what would be the maximum of the compressor's wattage at the peak. The compressors starts at lower RPM if I am correct and speeds up later on. AMPS can be recorded and hopefully the resistor would make it happen. Resistor with heat-sink secured to the chassis to dissipate the heat is a good option.
@birdman3931ny
@birdman3931ny 2 жыл бұрын
@@commieslayer8218 I have tried to use a variable potentiometer. I have the fridge here ready for any tests. Get your people together that you have spoken to, here on this video and let's get our brains on it . I'm already buying a new fridge.... But I will not throw this one out until we crack the code.. Yes... It runs on. No way to break the coil side. I tested 3vety single wire for a switching, on off 12v source. None to be found. 4 wire motors always hot. I think the relay on the board just be breaking the ground side. I also thing that to break the add on relay we are trying to put in, it might have to go to a relay that is already on the board. So when a stock, on the board relay gets energized... The one we are all trying to put install also gets energized.... And de-energized.
@birdman3931ny
@birdman3931ny 2 жыл бұрын
@@commieslayer8218 get a hold of me
@commieslayer8218
@commieslayer8218 2 жыл бұрын
@@birdman3931ny I got things going on here right now, will let you know when ready. Thanks, I want to know as well.
@myfriendhenry1
@myfriendhenry1 7 ай бұрын
This will not work as-is on newer LGs. The inverter board KNOWS when the load is LOW (in this case ZERO) and it also knows when it is HIGH (load=current draw in amps.) You could make this cleaner with an Arduino to current sense the PWM on the condenser motor and throw a relay, but you still have the inverter board throwing an error and shutting things down. I would just get an LG compressor with the latest upgrades and install that, I do warranty repairs on these about one every other day and they are all doing fine. As long as you get a clean install and update the board software you are fine. I charge $400 to do these all day long and usually the compressor is under the 10 year warranty,
@turbochardged
@turbochardged Жыл бұрын
@7:20 for safety run the Line to the relay not the Neutral wire. Always break the energized leg.
@REALPAINTERGUY
@REALPAINTERGUY 4 жыл бұрын
So this embraco EGZ 70HLP should work for lg French door linear compressor?? Mine just failed.. Please help and thank you for the great video!!!
@andiehamlet2020
@andiehamlet2020 3 жыл бұрын
so with the kenmore french style refrigerator how do you change from 220 to 110 to work conventional compressor? how do you get 12v to run the relay from the condenser fan motor that carry 4 wires? red, black, move and yellow
@birdman3931ny
@birdman3931ny 2 жыл бұрын
That’s the question… and how do you get it to tell the logic board that the inverter is drawing power? No schematic for the latter kenmore board that I can find.
@jeremiahgeneration8910
@jeremiahgeneration8910 2 жыл бұрын
Did you have any luck figuring this out? Im going to try a 5 pin relay and using 3 of the 4 condenser fan motor wires and the other 2 pins of the relay will be the common wires from the incoming neutral and the neutral from the wires going to the compressor
@joshcobb4100
@joshcobb4100 Жыл бұрын
@@jeremiahgeneration8910 did this work?
@jeremiahgeneration8910
@jeremiahgeneration8910 Жыл бұрын
@@joshcobb4100 This will 100% work if you have a condensing motor that has 3 wires. I have done it about 5 times successfully on those style motors, however I have had a fridge in my garage for almost a year that has 4 wires on the condensing motor and I have yet to figure out a way to wire that style up
@vincentpribish9276
@vincentpribish9276 4 жыл бұрын
Which Embraco compressor are you using as a replacement ? Looking to replace a 700 BTU/h linear.
@jacquesrobert159
@jacquesrobert159 4 жыл бұрын
Thank you Jorge where are located?
@irvincastrejon9407
@irvincastrejon9407 4 жыл бұрын
Can you make a video In detail on how to install the 115v compressor.
@irvincastrejon9407
@irvincastrejon9407 4 жыл бұрын
Where are you located at???
@Asianredneckoutdoors
@Asianredneckoutdoors 3 жыл бұрын
I found the relay he used and I might do one since there’s only 2 videos out there and they don’t show the physical video
@shanegosman2049
@shanegosman2049 Жыл бұрын
I tried this but for some reason my compressor comes on but won't stop running when fan shuts off. Can you help?
@joshcobb4100
@joshcobb4100 Жыл бұрын
Same here. Seems some of these condenser fans get a constant 12v. They have a separate PWR signal wire that signals the fan to turn on. Any way to work around this????
@kolincamacho8675
@kolincamacho8675 3 жыл бұрын
Hi, I have this problem with a LG fridge, this use a fan motor of 4 wires ( PWM), where conect 12 volts to turn on relay?.
@houptee
@houptee 5 жыл бұрын
Have you seen bad restrictions in the LG dual evap machines? I am trying to figure out why I have crazy high side pressure and low side is in a vacuum. I think it's the 3 way valve is clogged up or stuck in the pump down position. These machines do a pump down and close off the valve and store the refrigerant in the condenser.
@benjspiegel
@benjspiegel 4 жыл бұрын
Did you figure out this issue? I am having the same issue on mine (vacuum on low side and very high pressure on the high side). Also, the led on the board is blinking 7 times.
@murraymadness4674
@murraymadness4674 3 жыл бұрын
I have one that had the three-way valve clogged almost completely to the fridge evap.
@bluuedaniel
@bluuedaniel 3 жыл бұрын
Embraco is the best!!
@titoimp2000
@titoimp2000 4 жыл бұрын
Hola puedes hacer un video haciendo el cambio de un inverter a uno regular .you can make 1 video when you make one thanks
@joshcobb4100
@joshcobb4100 Жыл бұрын
Hey man, thanks for the video have loved your content. Question for you. Some of these fans get a constant 12v with a separate PWR wire that signals it to turn on. This causes my compressor to just run constantly. Any ideas on this??
@maxfrederick1244
@maxfrederick1244 Жыл бұрын
Will this work for an LG LSXS26366S/02? with Linear Compressor
@thedraftdept
@thedraftdept 4 жыл бұрын
Jorge? Covid get you?
@Asianredneckoutdoors
@Asianredneckoutdoors 3 жыл бұрын
So I’m a up coming tech and I can’t figure out what kind of relay you’re talking about. Help? The one with 4 wires??
@bluuedaniel
@bluuedaniel 3 жыл бұрын
You can get a smaller relay powered by 12 volts. I get them from a car salvage,...you’ll need the smaller ones. They come in little rectangular with small prongs, flat. The big 30:or 40 amps will not workwith the little wires powering them. ,,fan wiresmfrom the fridge! If you order one get 20 amp rating. You can get KZbin videos telling you the power in location , plus and minus, and the two other connecting prongs that get joined for 5 prong , or 4:prong. Or other number of prongs.
@alexkercado8713
@alexkercado8713 4 жыл бұрын
Do you any pic from the ge relay
@Asianredneckoutdoors
@Asianredneckoutdoors 3 жыл бұрын
SONG CHUAN Relay 832A-1C-S 12VDC 4 feet 30A That the info for it, only eBay sales if
@thedraftdept
@thedraftdept 3 жыл бұрын
Dudes! I left info for a viable relay from grainger . $10.95 and a lot easier to connect . It uses 1/4" spade connectors for 120vac device and 3/16" spade connectors from automotive store for 12vdc coil inputs. Super easy and can mount it with screws or it's small enough to tuck in next to pcb
@jamesguralski5156
@jamesguralski5156 3 жыл бұрын
@@thedraftdept so if I do this mod the Kenmore frig [lg]. This will work!? Do I still need to software update the board?
@thedraftdept
@thedraftdept 3 жыл бұрын
@@jamesguralski5156 sorry, I don't think so... I am a commercial refrigeration guy... This over-engineered residential junk drives me crazy. Everything is apparently computer controlled and very little use if logic and/or mechanical controls. It should work just fine.
@jamesguralski5156
@jamesguralski5156 3 жыл бұрын
@@thedraftdept true. The model electronics just fail all the time. The old stuff works and still does...
@michaelo061
@michaelo061 3 жыл бұрын
Is there a way to wire it to a 4-wire condensing fan? I have an LGLSXS2633S, and "C Fan", and "F Fan", has 4 wires. Thanks!
@peet8004
@peet8004 3 жыл бұрын
Im having the same issue did you ever figure this out?
@scratchdent20031773
@scratchdent20031773 2 жыл бұрын
@@peet8004 did anyone figure this out
@devoncrampton5223
@devoncrampton5223 2 жыл бұрын
@@scratchdent20031773 im in the same boat.
@jeremiahgeneration8910
@jeremiahgeneration8910 2 жыл бұрын
@@scratchdent20031773 I'm working on it now, I will post the results if Im able to figure it out. It would be nice if the guy that posted the video would respond to 1 or 2 or all 95 people asking questions but I will do my best today to figure this out.
@caseydaley11
@caseydaley11 Жыл бұрын
I'm pretty sure he died guys. I wonder if it was from to much refrigerant. Another video I saw from a different guy mentioned the late Jorge Martinez
@adanvaldovinos6255
@adanvaldovinos6255 4 жыл бұрын
Jorge you have part number?
@chrishill9518
@chrishill9518 3 жыл бұрын
I have a question about the 3 way valve
@phongvo8363
@phongvo8363 4 жыл бұрын
Does the Embraco 70HLP work good on LG 29 Cu.Ft French door fridge?
@kkc1577
@kkc1577 2 жыл бұрын
What do you normally charge to change linear to regular compressor?
@marwansaad1150
@marwansaad1150 2 жыл бұрын
Good job
@brendasmith5937
@brendasmith5937 2 жыл бұрын
Ok. So every damn refrigerator I have looked at has issues with the compressor and converter. It was explained to me that newer refrigerators in the US are set up for European electricity and the converter gets burned out from the conversion of the electricity to the compressor. Would it be possible to just dedicate a 220 line to my refrigerator to avoid problems? Wouldn’t I have to by-pass the converter mechanism to do that? Electrical work is NOT my strength in life. Apparently appliance repair people will not do this work. Any explanations would be helpful as I don’t have a really good understanding.
@jeremiahgeneration8910
@jeremiahgeneration8910 2 жыл бұрын
I wouldnt do that one, not worth it. These fridges are junk and you're better off getting rid of it and getting something else that is more reliable. For example, I have a LG fridge that was made in 2008 that doesn't do all this fancy conversion crap and it still works. Get a simple reliable model and use your current fridge for target practice
@qeesher
@qeesher 3 жыл бұрын
What kind of embraco compressor do you use?
@raymondlaster5245
@raymondlaster5245 4 жыл бұрын
This is some amazing stuff. I just took a linera compressor off my LG and installed a basic whirlpool compressor and ran a 3 in 1 start capacitor straight to the wall. It's working really well. What's your thoughts on that.
@REALPAINTERGUY
@REALPAINTERGUY 4 жыл бұрын
Could you give me a diagram how to wire the compressor? And what's the part # of thr whirlpool comp? Or should i stick with the Embraco? Thanks so much.. Very impressed on what you are doing...
@thedraftdept
@thedraftdept 3 жыл бұрын
Umm, what cycles the compressor on/off? If you ran leads on 3n1 straight to wall outlet, seems it would stay on and not shut off.. I probably misunderstood you, because I'm sure you don't stand there watching a thermometer and unplug unit when it's cold enough and vice-versa.... Do you?
@IDG4EVER
@IDG4EVER 3 жыл бұрын
How and when would the compressor turn off? I think it should shit off when the compressor isn’t needed.
@JCnordic2983
@JCnordic2983 3 жыл бұрын
@@thedraftdept wouldn't the 3rd wire be connected the the motherboard for switching
@thedraftdept
@thedraftdept 4 жыл бұрын
I'm going to do this. My LG model # lmxs30796s . Do you pull 12vdc condenser fan signal from con6 or con7? I see reference to c-fan on both although con6 says c-fan pwn.. also, if I am deciphering small print on pcb correctly, colors do not match. On con7, I see 2 violet wires and 2 white/red stripe... or is one of them darker red or maybe reddish orange? I would trace it with voltmeter, but f-fan is exactly next to c-fan and I'm sure once I plug in refrigerator that 12vdc will be active on both condenser and evaporators . Can you clarify? I do commercial refrigeration and never have to deal with a computer overlord controlling everything. There is a t-stat that switches condensing unit on/off and evap fans run continuously.. anyhow, if I have to pull 12vdc signal from condenser fan motor instead of board, which 2 colors there? I see solid red, yellow, black, and violet.. Confused up on board by duplicate violet & red/white on same con7 and they don't seem to jive with print.. A nice close up of your connections would be nice if boards are all generally the same. Mine has the 3 way splitter/solenoid on it.. I assume for customized middle drawer temp? Or freezer? Not sure, this is my first and last LG refrigerator. Thanks, sorry so verbose
@thedraftdept
@thedraftdept 4 жыл бұрын
Hope I dont seem like a moron, your video was straight forward. I'm sure my motherboard is different, because like I said earlier, there are duplicates of same colors on con7 (upper rightmost connector) and they don't seem to agree with printed guide above connector. Again, thanks. Btw, brand new and compressor went after 9 months. Absolute junk!
@xXSaxFanXx
@xXSaxFanXx 2 жыл бұрын
No es el cable violeta del fan es el color rosa y el blanco con línea roja
@jozo3049
@jozo3049 3 жыл бұрын
Hi Jorge, Compressor is not working on my Sears Kenmore Elite refrigerator, Model #: 795.75043.610 Compressor is made in South Korea by LG. What can be done and how? Cane we get in touch for some questions. Thank you in advance. Joseph
@jozo3049
@jozo3049 3 жыл бұрын
I'm located in Chattanooga TN.
@Jorgem1010
@Jorgem1010 4 жыл бұрын
I think it be a better idea to make a better video. I’ll do it
@Jorgem1010
@Jorgem1010 4 жыл бұрын
I have a new channel lost the email to this.
@thedraftdept
@thedraftdept 4 жыл бұрын
Address?
@alldatword119
@alldatword119 4 жыл бұрын
Please help.. how can I contact you.. I can not get this thing to work!! Lol helpl
@bluuedaniel
@bluuedaniel 3 жыл бұрын
This is a great video with very much detail! Think, and figure it out if you want to succeed! This dude is busy
@alldatword119
@alldatword119 3 жыл бұрын
Just seen this comment.. you don’t know if this man busy or not shit.. and you don’t know me either.. That shit ridiculous how people just love to comment on on shit when no one talking to them.. I really hope y’all don’t do that to people in public bra lawd ..
@bluuedaniel
@bluuedaniel 3 жыл бұрын
He has a job, and you have to figure things out, research on you tube how a relay works , electricity is simple. He can’t guide you at every step of your ignorance..
@alldatword119
@alldatword119 3 жыл бұрын
@@bluuedaniel I said this 11 months ago.. I been figured it out but it’s ok to ask.. I don’t do circuit boards by trade.. mind your business and stop speaking for another man unless you are his wife.. wtf is wrong with people .. You did not have to tell me one word but you couldn’t help your self.. It’s ok to ask any question you want.. when I comment on a video you record and upload feel free to tell me whatever you want and it’s totally understandable.. When it’s on someone else’s video I feel it’s best to just shut the fuck up and keep scrolling.. Shit not even that serious.. leave me alone shit.
@bluuedaniel
@bluuedaniel 3 жыл бұрын
@@alldatword119 go to hellashole
@yuriykaradobri1581
@yuriykaradobri1581 8 ай бұрын
Like
@iksdeath
@iksdeath 4 жыл бұрын
Hey brother what is the part number for relay you are using
@Asianredneckoutdoors
@Asianredneckoutdoors 3 жыл бұрын
SONG CHUAN Relay 832A-1C-S 12VDC 4 feet 30A
@thedraftdept
@thedraftdept 3 жыл бұрын
Use relay from grainger. I have posted a link in earlier comments
@thedraftdept
@thedraftdept 4 жыл бұрын
Jorge, please look at my previous posts.. I have checked probably 30 wires on the board and I can not locate which wire on my board gives the 12vdc signal only when the c-fan comes on. I have checked all listed under c-fan on con7 and even checked the wire on con6 that referenced the c-fan.. Also, new issue... I know that the refrigerator fan is not coming on and maybe others.. first clue was low side going hard into vacuum. Pulled cover in fridge cabinet and verufied.. put it into test mode and all fans do come on... what could cause that... this is a LMXS30796S that failed 9 months after I plugged it in.. LG should be ashamed to charge people over 5k for these pieces of junk. I do commercial refrigeration and residential is just frightening and ridiculously overly complicated.. such as 4 wires to run small 12vdc fan motors... energy savings I guess? PLEASE HELP A BROTHA 😖😫
@dondesnoo1771
@dondesnoo1771 4 жыл бұрын
Why not just connect at the cond fan motor at bottom .I would think a230 to 24v or 12 transformer could be hooked to the old comp .leads to drive a relay some say aphone charger works
@thedraftdept
@thedraftdept 3 жыл бұрын
Well, the problem is that the control board sends variable voltage signals to the compressor. Starts off with lower voltage and slower compressor speeds and increases voltage and compressor speed as demand increases... Sounds a bit like control board forces the compressor to mimic what a TEV (TXV) does. Also, most cell phone chargers I've seen put out 5 volts (not enough) and if you use an A/C transformer, it puts out twice as much voltage as needed and I believe it's AC voltage, not DC . I found a great relay at Grainger and listed part number on one of my other comments. George has never answered me back, so I walked away from fridge for a while. My board is weird and doesn't match what he used as an example or even wiring diagram on back of unit. Everything connected up sweet and it cooled well except refrigerator compartment fans won't run unless in test mode and I checked every wire listed in diagram that referenced condenser fan and could not find the pair that powered down when fans shut off. May tackle later when my business slows down a bit and check the 4 wires that go into fan motor itself. Don't really know why all the 12vdc fan motors in this unit need 4 frickin wires to operate... Seems unnecessarily complicated. Also need to figure out why the compartment fans don't work unless I put board into diagnostic mode.. This is exactly why I do commercial equipment and not residential. They are simple and reliable and all use readily available components and don't have snotty proprietary parts... Even worse than proprietary, every model pretty much use parts unique to that model with only some interchangeable parts.
@thedraftdept
@thedraftdept 3 жыл бұрын
@@dondesnoo1771 Also, I like to keep my work neat and not have random wires running here and there. All my wiring is inside behind panel. Good suggestion using leads directly feeding fan motor. Already thought about that and not much slack to pull harness out enough to patiently test the 16 combinations the 4 wires present unless you know which 2 actually have the 12vdc signal only when the fan runs... I have no clue why a simple 12vdc electric motor needs 4 wires to run... 1 might be sensor feed if variable speed? Pretty sure the variable speed fan motors I see on walk in cooler evaporators still only use 2.. I don't see that many. Heck, a/c air handlers use a bunch of wires, but I understand why... 1 speed for heat, another for fan only, and another for cooling mode. It's unnecessary for a condenser fan to change speeds unless it's an indoor condensing unit mounted outside with pressure control to shut fan off during winter until it builds enough head pressure to be efficient and then back on... Still, not variable... On/off..
@houptee
@houptee 3 жыл бұрын
This manual should be close to the same as your model. Look at page 23 is the wiring diagram and condenser fan is called C Fan at CON 11 and has 3 wires. One is a feedback signal for rpm to the mainboard to monitor if fan is working, do not use that wire for the relay. Then on page 37 it shows CON 11 is the connector on mainboard and you want to tap into wires 1 and 2 to trigger the 12 v relay. www.uncleharrywizard.com/nephewclub/wizardfrig/lg/lmx28994st-lg-refrigerator.pdf
@jeremiahgeneration8910
@jeremiahgeneration8910 2 жыл бұрын
@@thedraftdept Just curious if you were ever able to figure this one out? I have done this trick successfully to 8 or 9 of these refrigerators but I recently just encountered my first LG with 4 wires for the condenser fan motor. I agree that it is ridiculously over complicated, I think they do this crap on purpose so you have to use the original parts only or go buy another fancy looking piece of junk. It has to put out 12V though correct? Is it a matter of finding the color combination of 2 wires that generates the 12V? For example I have experimented quite a bit on other LG & Kenmore fridges and if you have a fridge with 3 wires to the condenser motor it doesn't matter which 2 wires you use to run to the relay. The dude that posted this video doesn't respond to any questions which is ironic if you are having a KZbin channel why would you post something and give anyone and everyone the middle finger when viewers watch and have questions.. seems counter productive to me but live and let live I suppose. Anyway I have one of these things in my garage that I havent been able to figure out with the 4 wire condenser fan motors and I was hoping you found a solution?
@joseluisgonzalezlopez9696
@joseluisgonzalezlopez9696 3 жыл бұрын
Excelente
@JCnordic2983
@JCnordic2983 3 жыл бұрын
Jorge, are you concerned with the testing phase with the 200 volts spike before it drops to 80, if you have the mother board power line out would burn up the compressor?
@iksdeath
@iksdeath 4 жыл бұрын
How is the defrost going to work if you turning off the compressor
@thedraftdept
@thedraftdept 4 жыл бұрын
Residential refrigeration does not use hot gas defrost and I've only seen that at 1 of my commercial accounts... Hot gas defrost basically works like a heat pump A/C by a reversing valve that forces the evap to become the condenser. Looks like residential refrigeration uses hot electic defrost elements to melt ice from coils on freezer and refrigerator.. Mmkay, compressor has nothing to do with defrost.
@JCnordic2983
@JCnordic2983 3 жыл бұрын
Yep it burned the circuit starting test circuit.
@qeesher
@qeesher 3 жыл бұрын
You disconnect wire going to compressor from the motherboard. You will get voltage from the power.
@hungle-hd3eg
@hungle-hd3eg 3 жыл бұрын
Where is your business location
@JCnordic2983
@JCnordic2983 3 жыл бұрын
No more motherboard
@samsonleung1708
@samsonleung1708 4 жыл бұрын
k
@gabrielcamargo1663
@gabrielcamargo1663 2 жыл бұрын
Lacrota
Why is There an Epidemic of Bad Refrigerators?
17:26
Steve Lehto
Рет қаралды 678 М.
How to replace LG liner compressor with regular aftermarket compressor.
22:15
PROTHERMAL REFRIGERATION & HVAC
Рет қаралды 1,7 М.
Мы сделали гигантские сухарики!  #большаяеда
00:44
The Giant sleep in the town 👹🛏️🏡
00:24
Construction Site
Рет қаралды 20 МЛН
КТО ЛЮБИТ ГРИБЫ?? #shorts
00:24
Паша Осадчий
Рет қаралды 1,4 МЛН
I Installed R600a Inverter Compressor In OLD Refrigerator!!
12:32
Forever Tech English
Рет қаралды 1 МЛН
Replacing LG Linear compressor with a regular compressor
9:15
The Appliance Technician
Рет қаралды 39 М.
#TECHTALK Check this before changing LG compressor
7:18
TMM Appliance Network
Рет қаралды 52 М.
Como adaptar compresor convencional en refrigerador LG Inverter,motor de cuatro cables
22:22
Repair LG and/or Samsung Bad Linear Compressor
14:00
Samuel Eiland
Рет қаралды 4,1 М.
Cutting open a failed LG refrigerator compressor
13:41
Joe's Garage
Рет қаралды 243 М.
LG Fridge not cold? SOLVED..Finally!! Stop wasting your money!
12:51
FourBoysGarage
Рет қаралды 96 М.
LG refrigerator replacement linear compressor with conventional
14:46
Best Pro Appliance Repair in Colorado
Рет қаралды 90 М.
Мы сделали гигантские сухарики!  #большаяеда